The BPEU Series of AC/DC Converters is available with multiple outputs and output power from 1300 W up to 3000 W. All models incorporate active Power Factor Correction (PFC). Other standard features include current and voltage monitoring, overvoltage, overtemperature as well as short circuit protection. These power supplies were designed to power radio-frequency power amplifier (RFPA) applications in the Broadcasting industry. Output Power 3000 W Active PFC High Efficiency Input Voltage: Single-Phase 220/240 VAC Main Output: 30-50 V/40 A Auxiliary Output: 24 V/3.5 A Current and Voltage Monitoring Remote Enable North America +1- Asia-Pacific +86.755.29885888 Bel Power Solutions 152 North 3rd Street, Suite 805 San Jose, CA 95112 USA Europe, Middle East +353 61 225 977
Voltage Current Frequency Efficiency Power Factor Inrush Current 185 264 VAC Single Phase 20A @ full load @ 185 VAC Single Phase 44-63 Hz 92% @ full load @ 230 VAC > 0.97 @ full load @ 230 VAC 30 Apk @ 230 VAC OUTPUT VOLTAGE (VDC) Inom (A) Ipk (A) TOLERANCE (%) RIPPLE (%) POWER (W) V1 +30 to 50 * 29 @ 50V ** 33 @ 45V ** 2 < 3 1650 V2 +30 to 50 * 29 @ 50V ** 33 @ 45V ** 5 5 1650 V3*** +24 3.5 4 5 5 84 * V1 V2 adjustable by single multi turns trimmer set on board or by remote 0 to 5 Vexternal signal (see procedure below). ** Imax total V1 V2 = 58 A @ 5 0V / 60 A @ 45 V. *** Internal OR diode in series on positive pole. Over Load Short Circuit Over Voltage (V1, V2) Over temperature General: Constant Current Hiccup mode (auto recovery) Set point = 58 V ± 5%, latching Non-latching with hysteresis AC side thermal fuses (T) V1, V2 current monitor IM (IMTOT) Linear analog signal 100 mv 1 A (IMTOT: 0 65 A = 0 4 V) Output V1, V2 voltage monitor VM Linear analog signal 100 mv 1 V Over Temperature Alarm Open collector, max. sink 4 ma; Alarm = Low (on = 70 C; reset = 60 C tolerance ± 5%) Over Temperature Protection Open collector, max. sink 4 ma; Alarm = Low (on = 80 C; reset = 70 C tolerance ± 5%) Power Fail main under voltage Open collector, max. sink 4 ma; Alarm = Low (set point Vin < 180 VAC) Remote Enable output V1, V2 Connected to COM = Power On, floating = Off (sink 5 mamps min.) Remote Enable output V3 Connected to COM = Power On, floating = Off (sink 5 mamps min.) Operating Temperature: Storage Temperature: 10 to +45 C (see Thermal Protection) 20 to +85 C
Safety: EMC / EMI CE Mark EN60950-1 EN55022 Conducted Noise ( Industrial level ) EN61000 4 4 Fast Transients EN61000 4 5 Surges (± 2 kv common ± 1 kv differential) EN61000 4 11 Voltage Dips EN61000 3 2 Harmonics Current Input Output Signals /Controls N 3 Fast on male connectors (6.35 x 0.8 mm), L, N, PE V1, V2: 4 pole screw type terminal block (2 pole for Positive and 2 pole for Negative) V3: N 2 Fast on male connectors (6.35 x 0.8 mm) Male FLAT type 10 pole dual in line connector Figure 1 Connections
CURRENT MONITORS Place jumper JP1 cap shorting pins 1 2 to read Current Monitor Total via pin 6 and Current Monitor Vout2 via pin 3 Place jumper JP1 cap shorting pins 2 3 to read Current Monitor Vout1 via pin 6 and Current Monitor Vout2 via pin 3 MAIN OUTPUT VOLTAGE TRIM (V1) Place jumper JP2 cap shorting pins 1 2 to adjust Vout manually by on board trimmer "+48Vadj" Place jumper JP2 cap shorting pins 2 3 to reduce linearly Vout by external 0 5 VDC source as below: 0 V Vout = 50 V 5 V Vout = 30 V
Figure 2 - Mechanical Drawing All dimensions are nominal and expressed in millimeters. Tolerance 0.5 mm max. NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.