PrimaX IR. HART Specification

Similar documents
Model Ultima OPIR-5. Infrared Open Path Gas Detector HART Field Device Specification. Instruction Manual

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08

MODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

DELTA CONTROLS CORPORATION

Oldham OLCT 200 Revision 1

DELTA CONTROLS CORPORATION

Report Title : IR-Display HART Field Device Specification

Kurz Instruments, Inc. MFT B-Series

HART Field Device Specification PR 5437 Device Revision 2

Dissolved Oxygen (DO) Transmitter SMARTPro HART Command Specification

HART Field Device Specification: CiDRA SONARtrac

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve

HART 7.x Field Device Specification for STT700 SmartLine Temperature Transmitters Document Number: 34-TT Revision: 1.0 Release: June 2017

Siemens SITRANS LUT400 revision 1

HART Field Device Specification Fisher FIELDVUE DVC5000 Digital Valve Controllers

HART Field Device Specification Fisher FIELDVUE DVC6000 and DVC6200 HW1 Digital Valve Controllers

HART 7.x Field Device Specification for Honeywell SLG 700 SmartLine Level Transmitter 34-SL Rev 6.0 December 2017

HART Applications SEC-5000 Gas Detector

Mettler-Toledo Smart Communications Protocol Revison 1.0: June 9, 2004 Cond Ind 7100/2(X)H Command Specification Page: 1 of 16

Transmitter Cond 7100 e /2 (X)H

The Omega product you have just received is of the highest quality available, offering superior performance, reliability and value to the user.

HART Actuator Field Unit Technical Manual Modular Design Electric Valve Actuators

Model IR700. Infrared Point Detector for Carbon Dioxide Gas Applications. Modbus Programming Guide

User Guide SS4-A HART

Model IR4000M. Multi-Point Monitor Modbus programming guide

HART. Actuator Control. Redefining Flow Control

Communication Modules. Add-on modules HART. Operating Instructions 07/2010 SITRANS F

AW Flow Meters HART Summary for RT-Ex15

RS485 S-Protocol Communications Supplemental Manual for Brooks GF40/GF80 Series Mass Flow Controllers and Meters

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

HART Protocol User Manual Rev. 1.0 December, 2014

HART Actuator Field Unit Technical Manual. (IQ / IQT 3 rd generation, CVA, CMA DEV_REV2) Publication PUB _0615

Model B3HU. PC CONFIGURATOR Model: B3HUCFG. Users Manual

For 2-wire Universal Temperature Transmitter B6U. PC CONFIGURATOR Model: B6UCFG. Users Manual

Report Title : IRmax Public Modbus Interface

HART 7.x Field Device Specification for Honeywell ST 800 Smart Pressure Transmitters Document Number: 34-ST Revision: 1.

Device Management Protocols Protocoles de gestion des appareils Gerätezugangsprotokolle. The HART Protocol

USER INSTRUCTIONS. MX/QX HART Field Unit. Installation Operation Maintenance. Experience In Motion FCD LMENIM /16

HART INTERFACE FOR INTELLI+

MICRO MOTION, INC. HART - Smart Communications Protocol 2000 SERIES ANALOG MVD TRANSMITTER-SPECIFIC COMMAND SPECIFICATION REVISION 6.

Advanced Test Equipment Rentals ATEC (2832)

Write Primary Variable Range Values Data written using command 35 will update the 4mA and 20mA settings in the menu.

Model IR5500. Infrared Open-Path Detector for Hydrocarbon Gases Modbus programming guide

Electromagnetic Flowmeter FXT4000 (COPA-XT) HART-Protocol

PC CONFIGURATOR Model: 27HUCFG. Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

Introduction. For more information. HART Protocol 7.0 Valid for software levels from 05.00

General Monitors S5000 Modbus Specification. Order No.: MANS5000M/00. MSAsafety.com

Page 1 MRK-D-0011, V1.1 Aeroqual SM50 User Guide

XgardIQ. Intelligent Gas Detector and Transmitter. Modbus Field Device Specification

Electromagnetic Flowmeter ProcessMaster, HygienicMaster FEX300, FEX500

WirelessHART Toxic & Combustible Gas Detector P/N: TCD50H1A

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

FUJI HART EXPLORER INSTRUCTION MANUAL

Certificate of Compliance

KROHNE H250 SN /01-03 MC H250/RR/M9/K2/ESK-Z C K F CIV MD C2H50H D 0.93 kg/l V 2.5 mpa.s T 23.5 C P 0.

QEL - DEDESCO 5935 Ottawa Street Richmond, Ontario, Canada, K0A 2Z0.

LC-110/H. Reference Manual

Transducers & Transmitters HART USERS MANUAL. GP:50 New York LTD Long Road Grand Island, NY USA

HRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1

Polytron 2 XP Ex. Transmitter for Catalytic Combustion Sensors. Operating Manual

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

GE Fanuc IC695ALG708. Rx3i PacSystem

HART Density Gauge Datasheet

MVI56-HART ControlLogix Platform HART Multi-drop Master Communication Module

HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve

Model B6U / B6U-B PC CONFIGURATOR (model: B6UCON)

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

PLX51-HART-4I. 4-Channel HART Input Multidrop Field Device USER MANUAL

PROCESS ANALYSERS. SERVOTOUGH FluegasExact Gas Analyser. QuickStart Manual. Part Number: D Revision: 1 Language: UK English

ULTIMA MOS-5. Intelligent Sensor for Hydrogen Sulfide Gas Detection Modbus Specifications

Agenda. Charging the QRAE II

Calibrating HART Transmitters. HCF_LIT-054, Revision 1.1

Profibus DP/V1 Interface for Bayard-Alpert / Pirani Gauge and High Pressure / Pirani Gauge

Technical Bulletin, HT/HM HART Module

Advanced Test Equipment Rentals ATEC (2832)

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

MODEL 173 PROBE TYPE LEVEL TRANSMITTER With HART INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS DELTA CONTROLS CORPORATION

Using the MODBUS Protocol with Athena Series C (1ZC, 16C, 18C, and 25C) Controllers

AwiaTech WirelessHART TM Rapid Development Kit Manual

Installation and operation manual ReciFlow Gas

SOFTWARE FUNCTIONAL REQUIREMENTS SPECIFICATION. Athena DeviceNet Interface Module Revision /26/2001

HART 710. User s Manual Version HART-710 User Manual (Version 1.00, July/2010) PAGE: 1

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

Modbus Communications Board

Configuring the DX99 HART Node for HART Field Devices

HRM-0800 Instruction Manual

Part I - Installation Tools Needed Adjustable Wrench. TX200H HART Pressure Transmitter. Installation and Maintenance Instructions GENERAL IMTX200H-04

Contents General Data Data Exchange Mode Block Model

Instruction Manual OWRB 4040 AES1 OWRB 4040 AES2 OWRB 4040 AAS1 OWRB 4040 AAS2

last update December 1, 2010 reference smtirin06n page 1/21 SMARTEC INFRARED INTERFACE BOARD SMTIRIN06

Proline Prowirl 72, 73

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Micro Motion Heavy Fuel Viscosity Meters (HFVM) Viscomaster

Autrol STT30 Ver 1.0. User s Guide MPC-E012B. Series. STT30 Ver 1.0. User Guide. Duon System Co.,Ltd

Instruction and Operation Manual

Fox Thermal Instruments, Inc.

Transcription:

PrimaX IR HART Specification The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by MSA. Instruction Manual MSA reserves the right to change published specifications and designs without prior notice. Document No. 10125187 Revision 0

Table of Contents TABLE OF CONTENTS...II 1.0 INTRODUCTION...1 1.1 Scope...1 1.2 Purpose...1 1.3 References...1 2.0 DEVICE IDENTIFICATION...1 3.0 PRODUCT OVERVIEW...2 3.1 Getting Started...2 4.0 PRODUCT INTERFACES...2 4.1 Host Interface...2 4.2 Local Interfaces, Jumpers, and Switches...2 5.0 DEVICE VARIABLES...2 6.0 DYNAMIC VARIABLES...3 6.1 Primary Variable = percent lower explosive limit (% LEL)...3 6.2 Secondary, Tertiary, and Quaternary Variables: Not Applicable...3 7.0 STATUS INFORMATION...4 8.0 UNIVERSAL COMMANDS...5 9.0 COMMON PRACTICE COMMANDS...5 9.1 Supported Commands...5 9.2 Burst Mode...5 9.3 Catch Device Variable...5 10.0 DEVICE SPECIFIC COMMANDS...6 10.1 Command #135: Read Gas Curve...6 10.2 Command #141: Read Cal Signal Setting...6 10.3 Command #145: Read Loop Signal Levels...7 10.4 Command #150: Write User Gas Name...7 10.5 Command #177: Set Span Value...8 10.6 Command #178: Set Gas Curve...9 10.7 Command #181: Calibration Signal Enable...10 10.8 Command #182: Start Calibration...11 10.9 Command #183: Calibration Abort...12 10.10 Command #189: Write Loop Signal Levels...13 ii

11.0 TABLES...14 11.1 PrimaX IR-HART Device Specific Commands Summary...14 12.0 PERFORMANCE...15 12.1 Sampling Rates...15 12.2 Power-up...15 12.3 Device Reset...15 12.4 Self-Test...15 12.5 Command Response Delay...15 12.6 Busy and Delayed-Response...15 12.7 Long Messages...15 12.8 Non-Volatile Memory...15 12.9 Operating Modes...16 12.10 Write Protection...16 ANNEX A. CAPABILITY CHECKLIST...16 ANNEX B. DEFAULT CONFIGURATION...17 ANNEX C. DEVICE DESCRIPTOR LANGUAGE MENU...18 iii

1.0 Introduction 1.1 Scope The PrimaX IR Gas Detector complies with HART Protocol Revision 7.0. This document specifies all of the device specific features and documents HART Protocol implementation details. The functionality of this Field Device is described sufficiently to allow its proper application in a process and its complete support in HART capable Host Applications. 1.2 Purpose This specification is designed to complement the PrimaX IR Gas Detector Instruction Manual by providing a complete description of this field device from a HART Communications perspective. This specification is designed to be a technical reference for HART capable host application developers, system integrators, and knowledgeable end users. 1.3 References DOCUMENT NAME HART Communications Protocol Specifications PrimaX IR Gas Detector Instruction Manual DOCUMENT RELATIONSHIP This is used to insure compliance with the HART Communication Protocol. This is the MSA PrimaX IR Gas Detector Product Instruction Manual. 2.0 Device Identification The following is the Field Device Identification Data for the instrument. Manufacturer s Name HART ID Code HART Protocol Revision Number of Device Variables Physical Layers Supported Physical Device Category Mine Safety Appliances, Inc. (MSA) 224 (E0 Hex) 7.0 0 1 FSK Model Number Device Type Code: Device Revision: PrimaX IR Detector 246 (F6 Hex) 1 1

3.0 Product Overview The PrimaX IR Gas Detector is an intelligent sensor for the detection of various gases and vapors. The microprocessor-based electronics processes information at the sensor site, within an explosion-proof housing. The PrimaX IR Gas Detector accurately measures the desired gas and reports the measurement as percent lower explosive limit (% LEL). 3.1 Getting Started In order to enable HART communication with the PrimaX IR Gas Detector, users may employ several means including HART handheld communicators or PC-based systems. Once the detector is installed (see PrimaX IR Instruction Manual) and connected to either a PC host application or a handheld terminal, the master will commonly begin communication to the PrimaX IR Detector by using the HART Command #0 and address 0. If the field device is programmed with address 0 (factory default is 0), the field device will then respond with the unique identifier information associated with Hart command 0. NOTE: The handheld device allows for the retrieval of diagnostic information and input of device settings as needed and should not be used as a permanent part of a safety system. 4.0 Product Interfaces 4.1 Host Interface The HART interface uses the 4 20 ma current loop. Refer to the installation manual for connection details. 4.1.1 Analog Output: PrimaX IR Mode The primary variable is proportional to the percent lower explosive limit (% LEL). 4.0 ma output current corresponds to 0 % LEL; 20.0 ma output current corresponds to 100 % LEL or 100% of full scale. 4.2 Local Interfaces, Jumpers, and Switches 4.2.1 Local Controls and Displays Refer to the Installation Manual for connection details. 4.2.2 Internal Jumpers and Switches Refer to the Installation Manual for connection details. 5.0 Device Variables 2

There are no device variables exposed to the user. 6.0 Dynamic Variables There is only one Dynamic Variable exposed to the user. 6.1 Primary Variable = percent lower explosive limit (% LEL) The primary variable is proportional to the percent lower explosive limit (% LEL). 4.0 ma output current corresponds to 0 % LEL; 20.0 ma output current corresponds to 100 % LEL or 100% of full scale. 6.2 Secondary, Tertiary, and Quaternary Variables: Not Applicable There are none defined for the PrimaX IR product. 3

7.0 Status Information Various device status bits, which are returned via Universal Command #48, are shown below. The remainder of the bytes (bytes 3-24) transmitted in the response are all zero (not implemented). Byte Bit Description Class 0 1 0 Circuit Fault Fault 4,7 1 Lamp Fault Fault 4,7 2 Optics Heater Failure Error 4 3 Sensor Underrange Fault 4,7 4 Not Used N/A 4 5 Full Obscuration Error 4 6 Cal Cap Attached Timeout Fault Fault 4,7 7 Not Used N/A 4 0 Zero Calibration in Progress Status 4 1 Span Calibration in Progress Status 4 2 Zero Calibration Success Status Status 4 3 Span Calibration Success Status Status 4 4 Not Used N/A 4 5 Not Used N/A 4 6 Calibration Aborted N/A 4 7 Cal Cap Attached Status 4 2 0 Cal Signal Enabled Status 4 1 Cleaning Mode Detected Error 4 2 Leg Heater On Status 4 3 Lamp 1 Status (1=On; 0=Off) Status 4 4 Lamp 2 Status (1=On; 0=Off) Status 4 5 Not Used N/A 4 6 Not Used N/A 4 7 Not Used N/A 4 Device Status Bits Set These bits may be set at power up to indicate instrument status. They may also be set by a 4

change detected during continuous background diagnostic testing. 8.0 Universal Commands Command 3 returns the current loop variable and the primary variable for a total of 9 bytes returned. 9.0 Common Practice Commands The following common practice commands are implemented. 9.1 Supported Commands The following common-practice commands shown below are implemented: Command Number 40 Enter/exit fixed current mode 42 Perform device software reset Meaning 43 Set primary variable zero HART Zero Cmd 45 Trim loop current zero 46 Trim loop current gain 59 Write number of response preambles 80 Read device variable trim points read span value 82 Write device variable trim point HART Span Cmd 9.2 Burst Mode The PrimaX IR Detector does not support Burst Mode. 9.3 Catch Device Variable This PrimaX IR Detector does not support Catch Device Variable. 5

10.0 Device Specific Commands The Device Specific commands are used strictly for the unique features of the PrimaX IR Detector and at the discretion of MSA. They are described here in Section 10.0 and are summarized in Section 11, Table 1. 10.1 Command #135: Read Gas Curve This command reads the Gas Curve selected on the PrimaX IR Detector The User Gas Name is also returned. Request Data Bytes None N/A N/A Response Data Bytes 0 Unsigned Gas Curve Number (see Gas Curve Table 11.2) 1-32 ASCII User Gas Name, Null-terminated ASCII string Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 1-15 Undefined 16 Error Access Restricted 17-127 Undefined 10.2 Command #141: Read Cal Signal Setting This command returns the PrimaX IR Cal Signal status. This is a single byte containing a 0 if disabled or 1 if enabled. If enabled, the output during calibration will be set to the programmed Cal Signal Level (default 3.0 ma). If disabled, the output will track the gas concentration. Request Data Bytes None N/A N/A Response Data Bytes 0 Enum Sensor Cal Signal Status (0=disabled, 1=enabled) 6

Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 1-15 Undefined 16 Error Access Restricted 17-127 Undefined 10.3 Command #145: Read Loop Signal Levels This command returns the PrimaX IR loop signaling levels as well as the minimum and maximum range for these levels. Request Data Bytes None N/A N/A Response Data Bytes 0-3 Float Fault level (ma) 4-7 Float Obscured, Dirty Optics level (ma) 8-11 Float Startup, Sensor Calibration level (ma) 12-15 Float Cleaning, Maintenance level (ma) 16-19 Float Minimum Signal Level (ma) 20-23 Float Maximum Signal Level (ma) Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 1-15 Undefined 16 Error Access Restricted 17-127 Undefined 10.4 Command #150: Write User Gas Name This command writes the PrimaX IR User Gas Name field. When the gas curve is changed (Command 182) the PrimaX IR Detector will change this field to the default gas name for that particular curve. The user may change this field to better identify the gas being measured. 7

Request Data Bytes 0-31 ASCII Null-terminated ASCII string Response Data Bytes 0-31 ASCII Null-terminated ASCII string Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 1-15 Undefined 16 Error Access Restricted 17-127 Undefined 10.5 Command #177: Set Span Value This command writes the PrimaX IR Span Value. The Span Value is used when performing a calibration. When a Span calibration is performed, the device automatically sets the steady reading obtained to this Span Value. Request Data Bytes 0-3 Float Span Value (%LEL) Response Data Bytes 0-3 Float Span Value (%LEL) 8

Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 1-2 Undefined 3 Error Parameter too large 4 Error Parameter too small 5 Error Too few data bytes 6 Undefined 7 Error In write-protect mode 8-15 Undefined 16 Error Access Restricted 17-31 Undefined 32 Error Busy 33-127 Undefined 10.6 Command #178: Set Gas Curve This command writes the PrimaX IR Gas Curve. Valid values are 1-15. The Gas Curve and User Gas Name are returned as confirmation. Request Data Bytes 0 Unsigned Gas Curve Number Response Data Bytes 0 Unsigned Gas Curve Number 1-31 ASCII User Gas Name, Null-terminated ASCII string 9

Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 1-2 Undefined 3 Error Parameter too large 4 Error Parameter too small 5 Error Too few data bytes 6 Undefined 7 Error In write-protect mode 8-15 Undefined 16 Error Access Restricted 17-31 Undefined 32 Error Busy 33-127 Undefined 10.7 Command #181: Calibration Signal Enable This command enables/disables the calibration signal on the PrimaX IR Detector. Refer to command #141. Request Data Bytes 0 Unsigned Cal Signal, 1=enable, 0=disable Response Data Bytes 0 Unsigned Cal Signal, 1=enable, 0=disable 10

Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 1-2 Undefined 3 Error Parameter too large 4 Error Parameter too small 5 Error Too few data bytes 6 Undefined 7 Error In write-protect mode 8-15 Undefined 16 Error Access Restricted 17-31 Undefined 32 Error Busy 33-127 Undefined 10.8 Command #182: Start Calibration This command writes a calibration mode number to the PrimaX IR. The mode number initiates a calibration sequence in the device. Request Data Bytes 0 Unsigned Calibration Mode Number, 0=Zero, 2=Zero & Span Response Data Bytes 0 Unsigned Calibration Mode Number 11

Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 1-2 Undefined 3 Error Parameter too large 4 Error Parameter too small 5 Error Too few data bytes 6 Undefined 7 Error In write-protect mode 8-15 Undefined 16 Error Access Restricted 17-31 Undefined 32 Error Busy 33-127 Undefined 10.9 Command #183: Calibration Abort This command writes a calibration Abort command to the PrimaX IR Detector. The calibration abort command instructs the device to suspend the calibration sequence initiated by the calibration mode command. Valid number for this command is 1. Request Data Bytes 0 Unsigned Calibration Abort Command Number (= 1) Response Data Bytes 0 Unsigned Calibration Abort Command Number (= 1) 12

Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 1-2 Undefined 3 Error Parameter too large 4 Error Parameter too small 5 Error Too few data bytes 6 Undefined 7 Error In write-protect mode 8-15 Undefined 16 Error Access Restricted 17-31 Undefined 32 Error Busy 33-127 Undefined 10.10 Command #189: Write Loop Signal Levels This command writes the PrimaX IR user-programmable loop signaling levels. All values are specified in ma (2.00, 3.00 etc.) and displayed with 2 decimal points. The valid range of values is 2.00 to 3.50 ma. Request Data Bytes 0-3 Float Fault level (ma) 4-7 Float Obscured, Dirty Optics level (ma) 8-11 Float Startup, Sensor Calibration level (ma) 12-15 Float Cleaning, Maintenance level (ma) Response Data Bytes 0-3 Float Fault level (ma) 4-7 Float Obscured, Dirty Optics level (ma) 8-11 Float Startup, Sensor Calibration level (ma) 12-15 Float Cleaning, Maintenance level (ma) 13

Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 1-2 Undefined 3 Error Parameter too large 4 Error Parameter too small 5 Error Too few data bytes 6 Undefined 7 Error In write-protect mode 8-15 Undefined 16 Error Access Restricted 17-31 Undefined 32 Error Busy 33-127 Undefined 11.0 Tables 11.1 PrimaX IR-HART Device Specific Commands Summary The following table is a summary of the PrimaX IR Detector Device Specific Commands. Command Number Byte Number Meaning 135 Read Gas Curve 141 Read Cal Signal Setting 145 Read Loop Signal Levels 150 Write User Gas Name 177 Set Span Value 178 Set Gas Curve 181 Calibration Signal Enable 182 Start Calibration 183 Calibration Abort 189 Write Loop Signal Levels Table 1: Device Specific Commands 14

12.0 Performance 12.1 Sampling Rates The PrimaX IR Detector samples the sensor in 1 second intervals. 12.2 Power-up On power up, the PrimaX IR Detector executes a start-up procedure, which requires approximately 10 seconds. During this time, the analog output is set to the value specified by the Calibration Loop Level (default 3.0 ma). After the start-up is completed, the unit updates based on the primary variable. 12.3 Device Reset The PrimaX IR Detector can be reset by command 42. 12.4 Self-Test The PrimaX IR Detector performs continuous diagnostics. Should any of the tests fail, the unit reports a fault condition. 12.5 Command Response Delay The PrimaX IR Detector has the following Command Response Times: Response Type Minimum Typical Maximum Response Time 20 ms 50 ms 100 ms 12.6 Busy and Delayed-Response The PrimaX IR Detector does not use delayed-response times. 12.7 Long Messages The largest data field used by the PrimaX IR Detector is in response to Command 135 (Read Gas Curve): 35 bytes including the two status bytes. 12.8 Non-Volatile Memory The PrimaX IR Detector uses EEPROM to hold the device s configuration parameters. New data is written to this memory immediately on execution of a write command. 15

12.9 Operating Modes The PrimaX IR Detector reports percent of lower explosive limit detected while in RUN mode. Various other modes are used to support the calibration of the instrument. 12.10 Write Protection The PrimaX IR Detector does not support any write protection mode. Annex A. Capability Checklist Manufacturer, model, and revision MSA PrimaX IR Detector Device type IR Gas Detector HART revision 7.0 Device Description available Yes Number and type of sensors 1 IR Sensor Number and type of actuators 0 Number and type of host side signals 1: 4 20 ma analog Number of Device Variables 0 Number of Dynamic Variables 1 Mapable Dynamic Variables No Number of common-practice commands 8 Number of device-specific commands 10 Bits of additional device status 16 Alternative operating modes No Burst mode No Write-protection Mfg Only 16

Annex B. Default Configuration Parameter Default value Lower Range Value 0 % LEL Upper Range Value 100 % LEL PV Units % Lower Explosive limit (LEL) Sensor type IR Number of wires 3 Damping time constant N/A Fault-indication jumper N/A Write-protect jumper N/A Number of response preambles 5 17

Annex C. Device Descriptor Language Menu 18

MINE SAFETY APPLIANCES COMPANY CRANBERRY TOWNSHIP, PENNSYLVANIA, USA 16066 1-800 MSA-INST www.msanet.com 19