SS-76 MF GPRS Buffer

Similar documents
SS-68BB MINI BUFFER. User Manual

SS-68BB USB MINI BUFFER. User Manual

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20

SS-22 USER MANUAL. Revision 01 Original document 04 May 2006 Revision 02 Cosmetic changes 23 January 2008 CONTENTS

SS-77 utms. User Manual

Metacom SCADA Communications Systems. Metacom MC402 Remote Router. Installation Manual V2.0

SS-76 NG. User Manual

FIFOTRACK PARAMETER TOOL USER GUIDE V1.1

MRD-310 MRD G Cellular Modem / Router Web configuration reference guide. Web configuration reference guide

RM6000 GPRS Modem / Router

GEM-10 GPRS/Modbus Gateway User Manual. Rev /2012

SS-75 NG. User Manual

CF2SCSI Disk Bridge User Guide

USER MANUAL FOR GS100/GS1003G

ADVANCED VEHICLE TECHNOLOGIES, Inc. AV. AVT-718 KIE Support. Introduction. Hardware. Firmware. Inc.

KX GPRS M2M I-NET. User s Guide. Version: 1.0. Date: March 17, KORTEX PSI 3 Bd Albert Camus Tel:

ZENDA Manager User Guide. Applicable Model: ZD-VT1

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

APPLICATION NOTE. GSM Configuration Guide for D-500 D-700. Introduction

ECOV-110 User s Manual

MetOne Particle Counter

SERIAL TO ETHERNET CONVERTER E-P User Manual

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

User Manual V1.1 Date: WiFi RS-232 Adapter. Red LED: IP Address Blue LED: TX/RX 5V Out (Pin 9)

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05

GW1000 User s Guide. Revision 1.04 Mar 30, 2008

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

Industrial Cellular IP Modem TD210 Series User Guide

USR-LTE 7S4 User Manual

GM862-GPS-OT User Guide

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Technical Description

Canlan INSTALLATION MANUAL

AVT-718 SDM-AOS Support

SSE232-LE Serial Server- User s Manual

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

PX Serial - Quick Start Guide

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Integrotech sp. z o.o. Plac Zwycięstwa 2 bud. D lok Łódź, Poland

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

ETM350C & ETM450C User Manual

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

Communi-Cell Communicator Nokia Version

Industrial Serial Device Server

BV4542. I2C or Serial 16x2 with Keypad interface

USR-G781 User Manual. File Version: V Jinan USR IOT Technology Limited 1

TrackingTheWorld Global Asset Tracker (GAT)

Ethernet to RS-422/485 adapter user manual

PCard2SCSI Flash-Tape User Guide

CC888 EZcarsharing Control System & T-Box Communication Protocol-V3.5

Wi-Fi Card/Box. User s Manual

Modbus Remote Communication Protocol for REM 54_. Technical Description

R O U T E R М Т 0 1 V e r s i o n v А Т O M e v e r i t h i n g n e w e m e r g e s n o w

NE-4100 Series Serial Command Mode User s Guide

HDV100A3 Command Response Protocol

BV4531U. I2C or Serial 6 Way Relay

EL731 PROFIBUS INTERFACE

EWAVE Inc Gracefield Ln. Dallas, Texas (972)

Release 2.11 Standard AXE Primary Firmware is not intended for use on any 8521 Controller not licensed as a RTU.

Prizm Mux Monitor (PMon) User Manual. March 13, Rev. 2.1

GPRS-RS232 Communicator. user guide

Victron Global Remote Victron Ethernet Remote

FPU-16 A-B PROTOCOL/DATA LOGGER MANUAL

CR3000 Copy Reader. Installation Guide

WRTU54G-TM. Release Notes. Software Version (Maintenance Release 9) Wireless Router with Home Phone Adapter

DATA LOGGER GEOLOGGER G8 PLUS

Unique Micro Design. Advanced Thinking Products. Model 164 Quad Coupler User Manual

RediGate 400 Series Getting Started Guide

Digi TransPort Routers. User Guide

AP-ENBD User Manual V0.2

Quick Guide Flex Gateway G2

Installation and Configuration Quick Guide. R3000 Quad. Industrial Cellular VPN Router with 4 Ethernet Ports (4 Eth + 1 RS-232/1 RS USB Host)

CAN Switch Board. User Guide. Document No. 29I U Rev. 1E. Page 1 of 20

180 Series Keypad. Handbook. Revision 2.1

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

ADVANCED VEHICLE TECHNOLOGIES, Inc. AV. AVT-718 LIN Support. Introduction. Firmware. Hardware. Inc.

USR-GPRS User Manual

Controller with internal Quad-band GSM/GPRS/3G modem MCL User manual Version 1.3

USER MANUAL Z-SG / Z-SG-L. Advanced Digital Strain gauge converter. Via Austria, PADOVA ITALY

ST-908 User Manual GPS Vehicle Tracker

USR-TCP User Manual

cctalk Product Manual for Ardac Elite

G-router GSM/GPRS to RS-232 and Ethernet Gateway Release Notes

Digi Connect WAN / ConnectPort WAN Cellular Setup of Surelink

GPS Personal Tracker User Manual V1.0 GT601

Addmaster Corporation

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

User Manual. cmt-svr Startup Guide

APPLICATION NOTE. Using the SUTRON RADAR LEVEL CONTROLLER (RLR ) with a MULTIMODEM GPRS (Wireless Modem MTCBA-G-F4)

MEMEX FANUC METER (512K) HSL5/MME MEMORY UPGRADE INSTALLATION AND USER MANUAL M100704A

Conettix Plug-in Communicator Interfaces B450

OnCell G3150A-LTE User s Manual

Proxicast IPSec VPN Client Example

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

Instructions Industrial 4G Router R700 - firmware version B Quick and easy setup of the Industrial 4G Router type R700

RTU8 Compact Telemetry Outstation IOTOOL32 PRO Software. Getting Started Guide

User s Manual. DL-Term. IM B9852UF-01E 4rd Edition

Eider Control INTRODUCTION EQUIPMENT ANATOMY OF AN EIDER CONTROL. Document number: 3349 Version: 03 Date: Jul 2016 USER GUIDE

AVT J1939 / J1708 Controller. Interface Control Document and Related Technical Information

BitPipe Cellular Dev- Kit

Transcription:

SS-76 MF GPRS Buffer User Manual

History of changes Revision 01 Original document 01 October 2006 Revision 02 Added section on Getting IMEI numbers etc. 13 October 2006 Revision 03 Correct name (SS-76) 14 November 2006 Revision 04 S/W update with new (IMEI and SCID) commands 26 November 2006 Revision 05 Draft for market release 18 January 2007 Revision 06 Cosmetic changes 20 March 2008 Revision 07 Add Alternate ETX character 23 February 2010 CONTENTS 1. INTRODUCTION... 3 2. FEATURES... 3 3. BASIC SETUP... 4 3.1 SIM CARD... 4 3.2 GPRS SETUP... 4 3.3 BUFFER SETUP... 4 4. GPRS MODULE COMMANDS... 5 5. BUFFER SETUP... 6 6. BUFFER COMMANDS... 6 7. CALL LOGGING & DIAGNOSTIC COMMANDS... 7 8. CONTACT DETAILS... 8 DOC. NO.: SS-76MF GPRS-14 (ISSUE 07) Page 2 of 8

1. INTRODUCTION The purpose of the SS-76 is to provide a buffer where the buffer collects data via its serial interface and sends the data out to a centralised site, using UDP Logger, via the GPRS network. 2. FEATURES Utilizes any currently available size Compact Flash memory Battery backup Remote setup Built in power supply LED indicators for - GPRS NET indicates that the unit is logged on to the GPRS network SVR indicates that contact has been established with the server TX indicates that data is being sent to the GSM module RX indicates that data is being received from the GSM module - BUFFER Heartbeat indicates that the unit is functional 50% - indicates when 50% of the buffer s memory capacity is reached 80% - indicates when 80% of the buffer s memory capacity is reached - PABX TX indicates that the buffer is transmitting data to the PABX RX indicates that the buffer is receiving data from the PABX - REMOTE DOWNLOAD TX indicates that the buffer is transmitting data to the GPRS module RX indicates that the buffer is receiving data from the GPRS module 1 - PWR indicates that there is power being supplied to the unit Diagnostics PING to test internet availability DNS lookup to find the logging server s IP address by using its DNS-name SNTP (Simple Network Time Protocol) support the unit date and time stamps the records using date and time information received from an internet time server. Push operation allows use of INTERNET APN Please Note the following: 1. The REMOTE DOWN LOAD TX & RX and GPRS TX & RX will frequently flash simultaneously 2. For a list of abbreviations please consult our website at www.sstelecoms.com 3. Please download the latest version of the UDP Logger from www.sstelecoms.com DOC. NO.: SS-76MF GPRS-14 (ISSUE 07) Page 3 of 8

3. BASIC SETUP 3.1 SIM CARD Some SIM cards require initialising for proper operation. To initialise the SIM card follow these steps: Place SIM card in cellular phone Enter PIN (if required) Request and accept MMS and Data settings Reply to SMS messages from Network if Network requests a reply. Accept more settings if required Make a missed call to a regular cellular phone. Remove PIN request if no security on SIM is required.(if the pin code is required use SIMPIN command to configure the GPRS MODULE. Put SIM card in the slot provided on the SS-76 Open the UDP Logger 3.2 GPRS SETUP Set the buffer name Make sure it is unique and 8 characters long. Duplicated or incorrect length buffer IDs will cause operational and logging problems Set the Host either to an IP address or an internet name. Ensure the Port and CmdPort are both 1122 If a private APN is used then set the Username and password Check that the Time Server is set Set the interval to 90 Set the baud rate (using the LBAUD command) to 57600 baud SAVE the settings RESET the GPRS module (using RESET command) 3.3 BUFFER SETUP Type in SS75SETUP Use the normal SS-75 commands for setting the SS-75 parameters such as baud rate, etc. Type QUIT to exit or wait for timeout DOC. NO.: SS-76MF GPRS-14 (ISSUE 07) Page 4 of 8

4. GPRS MODULE COMMANDS (Used when connected directly to the Serial Port at 19200 baud) RESET Closes the GPRS session and restarts the GPRS module VER Displays the Version Number SCID Outputs the SIM card ID IMEI Outputs the IMEI number of the module DIAG <n> Turns on (1) or off (0) diagnostic output. BUFID <BuffName> An 8 character field (it will be padded with _ after the entered characters if less than 8 characters are entered) This is the IP address or the FQDN (fully qualified domain name) of the HOST <address> logging server. If it is an FQDN a DNS lookup will determine the IP address PORT <pppp> This is the IP port number that the GPRS module will address (use) at the host. The default port number is 1122 This is the Access Point Name used by the particular network or it can be APN <apn> a private APN. Normally Vodacom & MTN use internet and Virgin uses vdata. USER <username> If a private APN is used then a username may be required (A maximum of 32 characters can be used) PASW <password> If a private APN is used then a password may be required (A maximum of 32 characters can be used) TIMESVR <address> Enter the IP address or FQDN of a suitable time server. The default is time-a.nist.gov CMDPORT <pppp> The port from which remote commands are accepted. Set to 1122 The time in seconds between polling the server when no data transfer is INTERVAL <nnn> taking place. Recommended setting is between 60 & 120, to allow NATTED addresses to remain in place LBAUD <baudrate> This is the buffer baud rate. For this unit it should be set to 57600 baud SS75 <n> Enables (1) or Disables (0) buffer mode operation. In order to log data this should not be disabled SS75TIME<n> Enables (1) or Disables (0) the setting of the buffer time once a successful Time Server query has been made. DISP Displays the current settings on the unit SAVE Saves the settings to non-volatile memory LOAD Restores the last complete and saved set of settings from non-volatile memory TARGET SETUP Is used to effect local, direct connection setup of the buffer component of this unit. This mode will timeout after 120 seconds of inactivity. QUIT Exits from buffer setup mode immediately. SIMPIN <nnnnnn> Pin code. Enter the PIN if the SIM card is set to request the PIN No. DOC. NO.: SS-76MF GPRS-14 (ISSUE 07) Page 5 of 8

5. BUFFER SETUP 5.1 Setting the links The links need to be changed from the default positions if: - The LAN Buffer is used with the Philips IS 1000 or Siemens Opera PABX systems - Wanting to bypass the opto-couplers and connecting directly to the PABX input - A Positive feed is required to the PABX Unscrew the top four screws and remove the lid to change the Links inside the unit. Position of Links Link Description 1 2 3 A B A B A B LK2 LK1 LK3 Common Ground: Pin 5 of PABX connector, connected to buffer B ground Ground isolated: Pin 5 of PABX connector is isolated (factory) A Voltage Feed: Feed positive voltage on Pin 2 of PABX connector B Normal operation (factory) A Direct input from PABX B (Requires LK 1 in pos B) Opto-Isolated input from PABX (factory) A (Recommend LK 1 in pos A) 6. BUFFER COMMANDS Note: The default settings are suitable for most applications Setup commands - <cr>after the instruction Command Description Sets the baud rate to the rate represented by the first 2 characters 'nn'. SETBAUD <nn> e.g. use 12 for 1200bd. Note: the full baud rate can be used, (SETBAUD 9600<cr>) SETHELLO <bufnam> Sets the buffer name to <bufnam> - MUST be a 6 char name YP <n> Sets the date insertion position 1=start of record, 0=end of record. SD <n> Enables date insertion. 1=enabled, 0=disabled. YY <n> Enables year insertion. 1=enabled, 0=disabled. YC <n> Enables century insertion. 1=enabled, 0=disabled. BEEP <n> Enables BEEPING. 1=enabled, 0=disabled SAD <n> Enables autodump mode. 1=enabled, 0=disabled SAT <n> Sets the delay before dumping to nn * 50 millisec. ST <nn> Sets delay between sets of data being sent Sets OnEmpty delay to nn* 50 millisec or the NonAckedResendDelay. RT <nn> Sets the number of retries for a UnAcked packet. If there is no communication between the buffer and GPRS module the SPR <nn> buffer forces a reset of the GPRS module as a health check. Sets the reset time for the GPRS module in minutes. n =00 to disable DOC. NO.: SS-76MF GPRS-14 (ISSUE 07) Page 6 of 8

UC <n> LF <n> TIME YYMMDDhhmmss S7 <n> ETX <hh> SS-76 MF GPRS USER MANUAL Converts lowercase to uppercase. 1=enabled, 0=disabled Stores multiple line feeds. 1=enabled, 0=disabled Sets the time. 7 Bit operation if n = 1. Note: use for 7 bit only operation, do not use for 7 bit with parity. Alternate end of line character. 7. CALL LOGGING & DIAGNOSTIC COMMANDS Command Description S or SEND Sends one record per command. HELLO Response is: <02h><SixCharId><SixCharId><cr><lf> VER Will output the revision number of the buffer firmware unit. SYS Diagnostic command. Do NOT use in logging program to get buffer status DUMP Empties buffer quickly. Do not use for collecting records. CLEAR Clears the buffer without sending it to the logging software TIME Response is: TIME YYMMDDHHhhmmss<cr><lf> DISP Displays some buffer setup info. /B Displays approximate buffer capacity in records e.g. 4K<cr><lf> for a 128k buffer. /C Outputs the number of calls in the buffer DPRC Displays the number of resets and clears the reset counter for the Network Interface. Sends nn records using following format: DataBlock<cr><lf> < r <record 1><cr><lf> SEND <nn> '' '' <record nn><cr><lf> TotalRecords nn<kr><lf> (nn may be less than the number requested, depending on how many records were available for sending.) To display buffer capacity and used memory. Response is: MstatccSSSSSSccUUUUUU<cr><lf> MM Where: cc is used internally and has no useful meaning. SSSSSS is the hex value of the memory installed. UUUUUU is the amount of memory used. e.g. Mstat0002000000000101 means that buffer has 128k ram fitted and there are 257 bytes of data in the buffer DOC. NO.: SS-76MF GPRS-14 (ISSUE 07) Page 7 of 8

8. CONTACT DETAILS Office: 23 Botha Avenue Lyttelton Manor Pretoria, Gauteng South Africa Tel: +27 12 664 4644 Fax: +27 86 614 5625 E-mail: info@sstelecoms.com Postal address: Postnet Suite 48 Private Bag x 1015 Lyttelton, 0140 Pretoria, Gauteng South Africa Sales Support: South Africa E-mail: sales@sstelecoms.com United Kingdom E-mail: uksales@sstelecoms.com Technical Support: E-mail: support@sstelecoms.com DOC. NO.: SS-76MF GPRS-14 (ISSUE 07) Page 8 of 8