TU-2016 TURBIDITY METER

Similar documents
MOISTURE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. 3, Hagavish st. Israel Tel: , Fax:

USER GUIDE Turbidity Meter Model TB400

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

LIGHT METER OPERATION MANUAL. auto range 0 to 50,000 Lux, 3 ranges. Model : LX-113S

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

TORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

SOIL MOISTURE METER OPERATION MANUAL. Model : DSMM500. Your purchase of this

VANE ANEMOMETER HUMIDITY/TEMP.

VACUUM METER Model : VC-9200

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

Pen type, with separate electrode PH METER Model : PH-220 OPERATION MANUAL

MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

MOISTURE METER OPERATION MANUAL. all in one. Model : PMS-713

Laser, PHOTO TACHOMETER RS

UV LIGHT METER UVC-254

MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107

HOT WIRE ANEMOMETER. Model : 204HA

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

PRESSURE METER OPERATION MANUAL. Model : PS-9302

LIGHT METER. Model : LM-81LX. Digital Measurement Metrology, Inc Digital Measurement Metrology, Inc

LIGHT METER OPERATION MANUAL. Model : LM-81LX

VANE ANEMOMETER BAROMETER HUMIDITY/TEMP. Model : ABH-4225

AC/DC MAGNETIC METER

OPERATION MANUAL. ph/mv SD card real time data logger ph METER. Model : PH-230SD

DIGITAL ANEMOMETER Model : AM-4203

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

12 channels TEMPERATURE RECORDER Model : BTM-4208SD

DATALOGGER. SD card, real time OPERATION MANUAL. Model : DL-9602SD

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

Sound Level Meter SL-4035SD. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS General Specifications Electrical Specifications...3

OPERATION MANUAL. SD card real time Data Recorder SOLAR POWER METER. Model : SPM-1116SD

SD card real time data logger TDS ( Total dissolved solids ), Salt '20 us/200 us/2 ms/20 ms/200 ms CONDUCTIVITY METER.

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

VIBRATION METER Model : VB-8213

UVA LIGHT METER OPERATION MANUAL. Model : UVA-365SD. SD card real time datalogger + Type K/J thermometer

Model LM-81LX. Instruction Manual. Illuminometer. reedinstruments. www. com

600 g x 0.02 g DIGITAL BALANCE

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

MMD7003 USER S MANUAL. DIGITAL and LED PRECISION MOISTURE METER

Pocket type SOUND LEVEL METER Model : SL-4030

OPERATION MANUAL. SD card real time data logger DISSOLVED OXYGEN METER. Model : DO-5512SD

Datalogging Conductivity/ TDS Meter. Instruction Manual

SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER

OPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer

AL10Con. Conductivity Meter - Instruction Manual

4 in 1 Anemometer, Humidity Light Meter, Thermometer

VB Model. Instruction Manual. Vibration Meter. reedinstruments. www. com

OPERATION MANUAL. SD card real time datalogger HUMIDITY/TEMP. MONITOR. Model : MHT-381SD

Anemometer, Hygrometer Light Meter, Thermometer

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

Manual Digital Thermometer PCE-T 390

Light Meter with Bar Graph

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

Model LM-81LX. Instruction Manual. Light Meter. reedinstruments. REED Instruments

USER`S MANUAL Professional measuring instrument 4 in 1 ATE-9508

OPERATION MANUAL. SD card real time datalogger 3 Channels TEMPERATURE DATA RECORDER. Model : MTM-380SD. Your purchase of this 3

OPERATION MANUAL. SD card real time datalogger HEAT INDEX WBGT METER. Model : WBGT-2010SD

Therma-Stor LLC Model LM in-1 Pocket Thermo-Anemometer, Hygrometer, Thermometer & Illuminometer. Instruction Manual.

User Guide. Conductivity Meter. Model EC210

USER GUIDE. AC/DC Magnetic Meter. Model MF100

Manual ph Meter PCE-228

Torque Meter. Instruction Manual

9 in 1 Anemometer, Humidity/Temp. meter, Light meter Pt 1000 Temp. ( optional ) Sport/Weather meter ENVIRONMENT METER Model : SP-8001

DIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T

User's Guide. Cup Thermo-Anemometer. Model AN400

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

Heavy Duty Differential Pressure Manometer. Model User's Guide

INSTRUCTION MANUAL. Models: H100 Light Meter

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments

Torque Meter. Instruction Manual

SD card real time datalogger, RS232/USB Frequency weighting and Time weighting meet IEC class 2, Personal sound exposure meet IEC 61252

TA 888 Hot Wire Anemometer

Visible Light SD Card Datalogger

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

Manual Sound level indicator PCE-353

PH SD Card Datalogger. Instruction Manual

Mini Environmental Quality Meter

RH/Temperature SD Card Datalogger. Instruction Manual

User's Guide. Heavy Duty Differential Pressure Manometer. Model

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Digital UVC Light Meter

Wide Range Pressure Meter Instruction Manual

Transcription:

INSTRUCTION MANUAL FOR TU-2016 TURBIDITY METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.VER.02-11.10

TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 3. FRONT PANEL DESCRIPTION...3 3-1 Cover of Testing bottle...3 3-2 Container of Testing bottle...3 3-3 Display...3 3-4 Hold Button ( Esc Button )...3 3-5 TEST/CAL Button...3 3-6 Power Button... 3 3-7 ZERO Button... 3 3-8 REC Button ( MAX, MIN Button )...3 3-9 Testing bottle with 0 NTU standard solution... 3 3-10 Testing bottle with 100 NTU standard solution...3 3-11 Empty testing bottle 1...3 3-12 Empty testing bottle 2...3 3-13 Battery Compartment/Cover... 3 3-14 Clean Cloth...3 3-15 Clean Solution ( Distill Water )...3 4. MEASURING PROCEDURE...4 4-1 Measurement Consideration... 4 4-2 Measurement... 5 4-3 Zero...6 4-4 Data Hold...6 4-5 Data Record ( Max., Min. reading )... 6 5. CALIBRATION PROCEDURE... 7 6. BATTERY REPLACEMENT...11

1. FEATURES * Designed to meet ISO 7027. * NTU ( Nephelometric TURBIDITY Unit ) measuring unit. * Wide and auto measurement range : 0 to 1,000 NTU. * High resolution : 0.01 NTU/1 NTU. * The unique optics structure, enables the instrument to read low value of TURBIDITY to the high level up to 1,000 NTU. * Four operation buttons and two calibration points, easy operation and giarantee the spec. accuracy. * Jumbo LCD, easy readout. * Microprocessor circuit assures maximum possible accuracy, provides special functions and features. * Battery operated for field and on-site testing convenience. * Data hold function for freezing the desired value on display. * Records Maximum and Minimum readings with Recall. * Heavy duty & compact housing with hard carrying case, designed for easy carry out & operation. * Auto shut off is available to save battery life. * Application : Test municipal water, food and beverage water, or other aqueous solution where fluid clarity is important. 2. SPECIFICATIONS Circuit Display Range Custom one-chip of microprocessor LSI circuit. LCD size : 41 mm x 34 mm. 0.00 to 50.00 NTU, 50 to 1,000 NTU * NTU : Nephelometric Turbidity Unit * Auto range 1

Accuracy ± 5 % F.S. or ± 0.5 NTU, which ever is greater. Light source LED, 850 nm. Detector Photo diode Standard Meet ISO 7027. Response time Less than 10 seconds. Sample volume 10 ml. needed Data hold Freeze the display reading. Memory recall Maximum & Minimum value. Display Approx. 1 second. sampling time Power off Auto shut off saves battery life or manual off by push button. Calibration 0 NTU, 100 NTU. points Operating 0 to 50. temperature Less than 85% R.H. and humidity Power supply DC 1.5 V battery ( UM4, AAA ) x 6 PCs, or equivalent. Power current Stand by Approx. DC 3.5 ma. Testing Approx. DC 36 ma. Weight 320 g/0.70 LB. @ Battery is included. Dimension 155 x 76 x 62 mm ( 6.1 x 3.0 x 2.4 inch) Accessories Instruction manaual 1 PC. Included Testing bottle with 0 NTU standard solution...1 PC. Testing bottle with 100 NTU standard solution...1 PC. Empty testing bottle...2 PCs Clean cloth... 1 PC. Clean solution ( Distill water )...1 bottle Hard carrying case, CA-08... 1 PC. Optional Accessories * Testing bottle with 100 NTU standard solution, TU-100NTU * Empty testing bottle, 0601 2

3. FRONT PANEL DESCRIPTION 3-1 Cover of Testing bottle 3-2 Container of Testing bottle 3-3 Display 3-4 Hold Button ( Esc Button ) 3-5 TEST/CAL Button 3-6 Power Button 3-7 ZERO Button 3-8 REC Button ( MAX, MIN Button ) 3-9 Testing bottle with 0 NTU standard solution 3-10 Testing bottle with 100 NTU standard solution 3-11 Empty testing bottle 1 3-12 Empty testing bottle 2 3-13 Battery Compartment/Cover 3-14 Clean Cloth 3-15 Clean Solution ( Distill Water ) 3

4. MEASURING PROCEDURE 4-1 Measurement Consideration White mark on the up position of " Testing Bottle " White mark on the edge of the " Container " Fig. 2 1)There is a " White mark " on the edge of the " Container " ( 3-2, Fig. 1 ) and also on the up position of " Testing Bottle " ( 3-9, 3-10, 3-11, 3-12, Fig. 1 ), refer Fig. 2. 2)When make the measurement ( or calibration ), it should keep the " Container white mark " face to face together with the " Testing bottle white mark " 4

3)Insert the " Testing bottle " to the bottom of " Container " ( 3-2, Fig. 1 ) completely. 4)Before the measurement, it should envelop in the " Cover " ( 3-1, Fig. 1 ) completely. Remark : Before the measurement, it should keep the outside of Testing Bottle under the dry condition and without existing any dust. 4-2 Measurement 1)Fill the measurement liquid into the " Testing bottle " ( 3-11, 3-12, Fig. 1 ). Attention : Model 0601 It should fill the 10 ml measurement liquid capacity until its level up to the " level marker " of the " Testing bottle " 2)Insert the " Testing bottle " to the bottom of " Container " ( 3-2, Fig. 1 ) completely. 3)Before the measurement, it should envelop in the " Cover " ( 3-1, Fig. 1 ) completely. 4)Power ON the meter by pressing the " Power Button " ( 3-6, Fig. 1 ) once. 5)Press " TEST Button " ( 3-5, Fig. 1 ) once, the display will show the text " test " ( TEST )", following the " test " will flash approx. 10 seconds, then the TURBIDITY value will present on the display along with the " ntu " unit. 5

Remark : * Under power OFF, if press the TEST Button " ( 3-5, Fig. 1 ) will power ON and going on to make the test automatically. * After the testing, within ten minutes approx., the meter will auto power OFF automatically. Wash ( Reinse ) the Testing bottle * After the testing, it should wash ( reinse ) the Testing Bottle by the Clean Solution ( Distill Water ) " ( 3-17, Fig. 1 ). 4-3 Zero When measure the " 0 NTU " liquid, if the display not show the zero value, it can deduct ( offset ) those " not zero value " with default, the zero procedures are : Press the " ZERO Button " ( 3-7, Fig, 1 ) continuously until the display show zero value then release the finger from the button 4-4 Data Hold During the measurement, press the " Hold Button " ( 3-4, Fig. 1 ) once will hold the measured value & the LCD will display a " HOLD " symbol. * Press the " Hold Button " once again will release the data hold function. 4-5 Data Record ( Max., Min. reading ) * The data record function records the maximum and minimum readings. Press the " REC Button " ( 3-8, Fig. 1 ) once to start the Data Record function and there will be a " REC. " symbol on the display. 6

* With the " REC. " symbol on the display : a)press the " REC Button " ( 3-8, Fig. 1 ) once, the " REC. MAX. " symbol along with the maximum value will appear on the display. If intend to delete the maximum value, just press the " Hold Button " ( 3-4, Fig. 1 ) once, then the display will show the " REC. " symbol only & execute the memory function continuously. b)press the " REC Button " ( 3-8, Fig. 1 ) again, the " REC. MIN. " symbol along with the minimum value will appear on the display. If intend to delete the minimum value, just press the " Hold Button " ( 3-4, Fig. 1 ) once, then the display will show the " REC. " symbol only & execute the memory function continuously. 5. CALIBRATION PROCEDURE 1)The meter can be calibrated under two kinds standard solution : 0 NTU standard solution 100 NTU standard solution 2)The meter ship along with a. Testing bottle with 0 NTU standard solution x 1 PC b. Testing bottle with 100 NTU standard solution x 1 PC as the standard accessories. 3)The complete calibration should be executed by following two solution : 0 NTU standard solution 100 NTU standard solution 7

4) Shaking the calibration bottle Before execute the calibration, it should shake the Standard solution ( TU-0NTU, TU-100NTU ) at least 5 seconds to keep the calibration solution under the uniform condition. 5) 0 NTU calibration * Insert the " 0 NTU standard solution into the " Container " ( 3-2, Fig. 1) and envelope in the " Cover " ( 3-1, Fig. 1 ) completely, other procedures please refer to above section 4-1, 4-2. * Press " CAL Button " ( 3-5, Fig. 1 ) continuously until the Display show the text " CAL " then release the button. CAL ntu 8

* During the display show text " CAL ", press the " CAL Button " ( 3-5, Fig. 1 ), the display will show CAL 0.00 ntu Now the meter is ready for the " 0 NTU " calibration * Press " CAL Button " ( 3-5, Fig. 1 ) once, the Display will show following text with flashing ( approx. 10 seconds ). CAL 0.0 ntu flashing Then the Display will show : CAL 100 ntu Now the meter is finished the " 0 NTU " calibration procedures and ready for " 100 NTU " calibration procedures. 9

6) 100 NTU calibration Refer to page 8, when finish the " 0 NTU " calibration procedures and the Display show CAL 100 ntu The meter is ready for " 100 NTU " calibration. * Insert the " 100 NTU standard solution into the " Container " ( 3-2, Fig. 1) and envelope in the " Cover " ( 3-1, Fig. 1 ) completely. Press " CAL Button " ( 3-5, Fig. 1 ) once, the Display will show following text with flashing ( approx. 10 seconds ). CAL 100 ntu flashing Then the LCD display will return to normal measurement screen, now the meter is finished the calibration procedures ( 0 NTU, 100 NTU calibration ) completely and ready for the measurement. 10

6. BATTERY REPLACEMENT 1)When the left corner of LCD display show " ", it is necessary to replace the battery. However, in-spec. measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. 2)Loss the " Battery Cover Screws " and slide the " Battery Cover " ( 3-13, Fig. 1 ) away from the instrument and remove the battery. 3)Replace with DC 1.5 V battery ( UM4, AAA, Alkaline/heavy duty ) x 6 PCs, and reinstate the cover. 4)Make sure the battery cover is secured after changing the battery. ` 11 0804-TU2016