Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Similar documents
Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

PowerMust Office Uninterruptible Power System

POWERWALKER. Uninterruptible Power Supply. Line Interactive VI 1000/1400/2000. Thank you for purchasing PowerWalker UPS.

INSTALLATION AND USER MANUAL Green Point T

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Powerware 3105 UPS User s manual

Powerware 3105 UPS User s manual

OPERATING INSTRUCTIONS UPS

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Table of contents. 1. Introduction

U P S USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Uninterruptible Power System. Line Interactive (Network) UPS

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

Model: VA/230W UPS Backup System

EATON 5S 850/1200/1600

22-60VDC Grid Tie Microinverter User Manual

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Smart Grid Tie Microinverter User Manual

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Back-UPS RS 550 Installation & Operation

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Model HM-535 Power Supply Installation and Service Instructions

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

1. IMPORTANT SAFETY INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during install

Back-UPS RS APC Back-UPS RS 800VA 120V Black

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

Smart-UPS APC Smart-UPS 1500VA USB & Serial 120V

C300R 1-3 kva. Rack/Tower VA. Installation/Manual. Service and support T: +44 (0)

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

VS Series 120V 600VA 300W Line-Interactive Desktop UPS, Tower, 6 Outlets

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

Version /11/2015. User Manual. PowerLine AV HD Gigabit Passthrough Kit DHP-P601AV

Smart-UPS APC Smart-UPS 750VA USB & Serial 120V

Uninterruptible Power Supplies

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

User s Manual OLS1000ERT(XL)2U OLS1500ERT(XL)2U OLS2000ERT(XL)2U OLS3000ERT(XL)2U

Smart-UPS APC Smart-UPS 2200VA USB & Serial 120V

Installation and Operation Back-UPS Pro 900

User s Manual OL1000EXL OL1500EXL OL2000EXL OL3000EXL. CyberPower Systems Inc. K

Installation and Operation Back-UPS Pro 900

User s Manual. Professional Rack Mount LCD XL Series PR1000ELCDRTXL2U/PR1500ELCDRTXL2U/ PR2200ELCDRTXL2U K

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S USER S MANUAL

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

LEGA ENERGY ELECTRONIC RELAY VOLTAGE STABILIZER VA USER MANUAL

Preparing to Install the VG248

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

ELV12 Series. Instruction Manual

easyraid Q24P2-U4R4 Hardware Manual

850VA 480W Line-Interactive UPS with 6 C13 Outlets - AVR, 230V, C14 Inlet, LCD, USB, Tower

1000VA/1500VA/2000VA/3000VA

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Smart-UPS APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Model 7705 Control Module

USER MANUAL Line Interactive UPS

FLP-PS DC Power Supply Model. Portable Sound System Mixer Amp/ Pre Amp/ Power Amp

EA300. EA300 series 500 ~ 1500VA

User Manual Back-UPS BE650MC

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Installation and Operation Manual Back-UPS BR900G-RS

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Codian IP VCR IP VCR 2200 Series

The power behind competitiveness. Delta UPS - Amplon Family. N Series, Single Phase 1/ 2/ 3 kva. User Manual.

TVAC25100 TVAC25110 User manual

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V

Smart Grid Tie Microinverter User Manual

EOS-6000 Series Optical A/B Switch User Manual DC Version

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Installation and Operation Back-UPS Pro BR700G-TW

EPS Power Supply

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Sivy SA-4327S Hardware User Manual

PowerNet RM SERIES 1500VA & 2200VA Line-interactive UPS USER MANUAL

Network Camera. Quick Guide DC-B1203X. Powered by

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial

Octostrip ORDERCODE 42220

Line Interactive UPS

Multi-touch Touch-Screen. Installation Guide

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

High Power Electronic Gear Installation and operation Guide

1 Safety Information Product Overview Installation Network Functions Operation... 12

E8431 First Edition Model: T00CP

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

HX1 Bluetooth Stereo Headset

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

JanusRAID SA-6692J Hardware User Manual

CUS150M1 Instruction Manual

DT-307B Vacuum Tube Amplifier. Instruction Manual

LVN5200A-R2, rev. 1, Hardware Installation Guide

Pulsar EXtreme 2000/3000 VA

Transcription:

Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. While every precaution has been taken to ensure accuracy and completeness in this manual, Emerson Network Power assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power pursues a policy of continuous product development and reserves the right to change the equipment design without notice. Copyright 2005 by Emerson Network Power All rights reserved. The contents in this document are subject to change without notice Page 1 V2.8 Emerson Network Power

Table of Contents Contents Safety Instructions 1. Product Introduction 5 2. System Description 6 3. Installation 7-9 4. Software 10 5. Troubleshooting 11 6. Technical data 12 Page 2 V2.8 Emerson Network Power

Safety Instructions Safety Instructions As dangerous voltages are present within the, only an Emerson technician or an Emerson-authorized technician is permitted to open it. Failure to observe this could result in electric shock risk and invalidation of any implied warranty Transport Please transport the system only in the original packaging (to protect against shock and impact). Set-up Condensation may occur if the system is moved directly from a cold to a warm environment. The system must be absolutely dry before being installed. Please allow an acclimatization time of at least two hours. Do not install the system near water or in damp environments. Do not install the system where it would be exposed to direct sunlight or near heat source. Do not block off ventilation openings in the system s housing. Installation This manual contains information concerning the installation and operation of the Emerson Network Power Liebert PSA iton Uninterruptible Power System () All relevant parts of the manual should be read prior to commencing the installation. Do not connect appliances or equipment (e.g. laser printer) to the output socket, which would overload the system. Place cables in such a way that no one can step on or trip over them. Do not connect domestic appliances such as hair dryers to output sockets. Connect the system only to an earthed shockproof socket outlet. Connection to any type of receptacle other than two pole, three wire grounded receptacle may result in shock hazard The building wiring socket outlet (shockproof socket outlet) must be easily accessible and close to the system. Please use only VDE-tested, CE-marked mains cable (e.g. the mains cable of your computer) to connect the system to the building wiring socket outlet (shockproof socket outlet). Please use only VDE-tested, CE-marked power cables to connect the loads to the system. The must be serviced by an authorized representative of Emerson Network Power. Failure to do so could result in personnel safety risk, equipment malfunction and invalidation of warranty. The Liebert PSA iton has been designed for Commercial/Industrial use only, and is not recommended for use in life support applications. In the event of Emergency press 'OFF' button and disconnect the power cord from AC Power supply to properly disable the Do not plug input to its own output. Do not attach power-strip or surge suppressor to the Page 3 V2.8 Emerson Network Power

Safety Instructions Operation Do not disconnect the mains cable on the system or the building wiring socket outlet (shockproof socket outlet) during operations since this would cancel the protective earthing of the system and of all connected loads. The system features its own, internal current source (batteries). The output sockets or output terminals block may be electrically lived even if the system is not connected to the building wiring socket outlet. In order to fully disconnect the system, first press the Standby switch then disconnect the mains lead. Ensure that no fluids or other foreign objects can enter the system. Maintenance, servicing and faults The system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel. Caution - risk of electric shock. Even after the unit is disconnected from the mains power supply (building wiring socket outlet), components inside the system are still connected to the battery and are still electrically live and dangerous. Before carrying out any kind of servicing and/or maintenance, disconnect the batteries and verify that no current is present and no hazardous voltage exist in the terminals of high capability capacitor such as BUS-capacitors. Only persons who are familiar with batteries and with the required precautionary measures may replace batteries and supervise operations. Unauthorised persons must be kept well away from the batteries. Caution - risk of electric shock. The battery circuit is not isolated from the input voltage. Hazardous voltages may occur between the battery terminals and the ground. Before touching, please verify that no voltage is present! Batteries may cause electric shock and have a high short-circuit current. Please take the precautionary measures specified below and any other measures necessary when working with batteries: - remove wristwatches, rings and other metal objects - use only tools with insulated grips and handles Do not short circuit battery terminals When changing batteries, install the same number and same type of batteries. Do not attempt to dispose of batteries by burning them. This could cause battery explosion. Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It may be toxic. Please replace the fuse only by a fuse of the same type and of the same amperage in order to avoid fire hazards. Do not dismantle the system Page 4 V2.8 Emerson Network Power

Product Introduction 2. Product Introduction This is specially designed for Personal Computer with multi-functions. Its light weight, compact design perfect fits to the limited working environment. The line of is equipped with boost and buck AVR to stabilize input voltage range. It is also built-in with DC start function. This function enables the to be started up without AC power supplied. Although it's a small, it's equipped with Smart RS-232 Communication Port to offer users more benefits. The download software helps users monitor inside status. The main features of the are listed below: Microprocessor control guarantees high reliability. Equipped with Boost and Buck AVR to stabilize the input voltage. DC Start Function. Built-in RS-232 Communication Port. Free Software bundled. (Please check Monitoring Software for detail information). Green Power Function for energy saving. Auto restart while AC recovers. Compact size, Light weight. Provides Modem and Phone line Surge Protection. Provide AC Overload Protection Page 5 V2.8 Emerson Network Power

System Description 3. System Description Front panel 1. Power Switch LED AC Mode: Green LED on Battery Mode: Green LED flashing Back Panel 1. Output receptacles 2. AC Input 3. Modem / Phone line Surge Protection 4. Communication Port 4 3 1 2 iton 600 iton 1000 4 3 1 2 5 iton 600 (India Version) Page 6 V2.8 Emerson Network Power

Installation 4. Installation Installing the is as easy as following the steps shown. Be aware that the power Switch must be kept in the ON position, otherwise, the will be disabled and your equipment will not be protected during a power failure. 4.1 Inspection Remove the from its package and inspect it for damage that may have occurred during shipping. If any damage is discovered, re-pack the unit and return it to the place of purchase. 4.2 Placement Install the unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your in an environment where the ambient temperature or humidity is high. Also, place the unit away from the monitor at least 20cm to avoid interference. 4.3 Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the to charge fully by leaving it plugged in for at least 8 hours. iton 600 iton 1000 iton 600 (India Version) Page 7 V2.8 Emerson Network Power

Installation 4.4 Computer Connection Connect one computer-related device into each of the power receptacles supplied on the back of the. COMPUTER COMPUTER COMPUTER iton 600 iton 1000 iton 600 (India Version) 4.5 Modem / Phone line Connection Plug incoming internet line into the In socket at the back of the. Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the. Plug the other end of the modem input socket as shown below. MODEM MODEM MODEM iton 600 iton 1000 iton 600 (India Version) 4.6 Serial cable Connection To allow for unattended system shutdown for your operating system, connect the serial cable as per diagram below. COMPUTER COMPUTER COMPUTER iton 600 iton 1000 iton 600 (India Version) Page 8 V2.8 Emerson Network Power

Installation 4.7 Turn On / Off To turn on the, just simply press power switch. Please do so gently to extend the life of the power switch 4.8 DC Start Function DC Start Function allows the to start up when AC utility power is not available and the battery is fully charged. Just simply press the power switch to turn on the. 4.9 Green Power Function All these Series are equipped with Green Power Function*. If no load connects to the, it will automatically shut down in 45 seconds for energy saving while power failure. The will restart while AC recovers * This feature is only applicable with iton 600 Page 9 V2.8 Emerson Network Power

Software 5. Software Free Monitoring Software The monitoring software, provides user-friendly interface to monitor and control your. This unique software provides safe auto shutdown for multi-computer systems during a power failure. With this software, users can monitor and control any on the same LAN no matter how far from the s. Features: Saves files before shutdown occurs Scheduled system shutdown Graphic display of status Warning notification via E-mail User-friendly interface Multi-language versions Installation procedure: 1. Insert the CD into CD ROM. 2. Connect the software cable 3. Follow the on-screen instructions to install the software. When your computer restarts, the software will appear as a green plug icon located in the system tray, near the clock Page 10 V2.8 Emerson Network Power

Trouble Shooting 6. Trouble Shooting If any abnormal situations occur that are not listed above, please call the authorized Emerson Network Power service engineers immediately. Page 11 V2.8 Emerson Network Power

6. Technical Data Liebert PSA iton PS600-TN PS1000-TN 600VA 1000VA CAPACITY V/AW 600VA/360W 1000VA/600W INPUT Voltage Range 140-300 VAC 160-300 V Frequency 45-65 Hz (Auto Sensing) 45-65 Hz (Auto Sensing) Voltage Range 230V 230V Voltage Regulation (Batt Mode) +/-10% +/-5% Frequency 50Hz or 60Hz 50Hz or 60Hz OUTPUT Frequency Regulation (Batt Mode) +/-1Hz +/- 1 Hz Output Waveform Stepped Waveform Stepped Waveform Overload 110% for 5 minutes as 'Mains' 110% for 5 minutes as 'Mains' mode mode Battery Type & Number 12V/7AH - 1Pc 12V/7AH - 2 Pcs BATTERY Backup time (*As per the loads) 15-22* mins 30 min typical* (with 1 PC) Recharge Time 8 hours to 90% after complete 8 hours to 90% after complete discharge discharge TRANSFER TIME Typical 4-8 ms 4-8 ms AC Mode Green Lights up Green Lights Up The 1st green lighting up, the 2nd to 5th green lighting up indicates load capacity INDICATOR Backup Mode Green Flashes Green Flashes The 1st green flashing, the 2nd to 5th green gradually lighting indicates batteries capability Fault Red Lighting up Backup Mode Sounds every 10 seconds Sounds every 10 seconds Low Battery Sounds every second Sounds every second AUDIBLE ALARM Overload Sounds every 0.5 seconds Sounds every 0.5 seconds Battery Replacement Sounds every 2 seconds Sounds every 2 seconds Fault Continuously Sounding Continuously Sounding PROTECTION Full Protection Discharge, overcharge and Discharge, overcharge and overload protection overload protection Dimension (m,m) PHYSICAL DxWxH 330 x 100 x 140 369x141x181 Net Weight 6 kg 13.5 kg 0-40 C 0-90% relative humidity 0-40 C 0-90% relative humidity Operating Environment ENVIRONMENT (non condensing) (non condensing) Noise Level Less than 40 db Less than 40 db INTERFACE RS 232 Support Windows Support Windows 95/98/NT/2000/XP and Linux 95/98/NT/2000/XP and Linux *For additional information on backup please contact your local Emerson Network Power representative Page 12 V2.8 Emerson Network Power