Service Considerations

Similar documents
PowerLogic ION7300 Series

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Bluetooth Shielding Instructions

Demo Kit Quick Start Guide

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

PS/IO Circuit Board Retrofit

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Installing the NEMA 4X Hatch

Chore-Tronics Mobile Server

Installing and Configuring Rialto Analytic Appliances

ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply

2U ATX12V 2.01 Power Supply

Model 2380 Rack-Mount Kit

5.25in Bay IDE Hard Drive Mobile Rack

Reliable ATX 12V 2.01 Power Supply

PCI Serial Card 2 Port RS-422/RS-485 PCI Serial Card with Terminal Block Connectors PCI2S422TB Instruction Manual Actual product may vary from photo

Instruction Guide. Two Port ISA Serial Card ISA2S550. The Professionals Source For Hard-to-Find Computer Parts

DATA DOUBLER. Apple Mac mini (2009)

MPP200 User s Manual

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Model 2380 Rack-Mount Kit

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

9500 and 9600 I/O Card Installation Instructions

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

To connect the AC adapter:

Dual-Bay Drive Enclosure for msata SSD Drives - USB 3.1 (10Gbps), USB-C - RAID

Wall. No opening (Example: LA-030-W)

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

Turbo Fiberglass Cone Fan and Grill Fan 36 Direct Drive. Installation & Operator s Instruction Manual

7191AD User Manual. June Daisy Data Displays, Inc Lewisberry Road, York Haven, PA Phone:

MPP1700 User s Manual

Application Guide. M 2174B Moloney Replacement Adapter Panel

USB 3.0 Spectra

S82S (3/7.5-W Models)

PowerLogic ION7550 RTU option

iq 16 Sync Charge Box

User s Guide. for Echo Express III-R Rackmount Thunderbolt -to-pcie Card Expansion Chassis

High-Performance Dual Fan 350-Watt ATX Power Supply. ATXPOW350DF Instruction Manual

iconverter 2-Module Power Chassis

1X2 HDMI Splitter with 3D Support

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

PowerLogic ION7550 / ION7650 Hardware Lockable Meter

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

3M Wrist Strap and Ground Monitor 773. User s Guide

Replacing the Gateway M275 Keyboard

1/2 Port High-Speed RS-232 PCI Serial Card 1/2 Port Low Profile High-Speed RS-232 PCI Serial Card PCI1S550 PCI1S550_LP PCI2S550 PCI2S550_LP

Four-port serial PCI card PCI4S550N. Instruction Manual. Actual product may vary from photo

ATX12V 2.2 Power Supply for HP & Compaq Systems

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions

Upgrading and Servicing Guide

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Application Guide. M-6200A Communications Hardware Kit Installation Instructions

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

OPT. Outdoor Payment Terminal. Service Guide OPW Fuel Management Systems Manual No. M Rev. 2

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Trayless SATA Drive Bay 5.25" Trayless SATA Hot Swap Drive Bay

DVI Extender over Fiber with EMI Shielding

CL-8. User Guide and Technical Information

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

AURA SSD FOR MAC PRO. Installation Guide

ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT.

Owner s Instruction Manual

User s Guide. for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

DVI Extender over Single CAT5 Mini SET

Gateway Profile 4 service guide

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Notices. Installation Considerations DANGER. Danger

Broadband Automatic Disconnect Switch. User Manual

SCSI PCI Card. 80 MBytes/sec Ultra2 SCSI PCI Controller Card PCISCSIU2W. Instruction Manual. Actual product may vary from photo

3.5 SATA/SAS Hard Drive Mobile Rack for 5.25 Bay - Trayless

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Installation Job Aid for Ethernet Routing Switch 5900 Series

DisplayPort to DVI Converter

PowerLogic ION7300 series Power and energy meter

VIP-812A DUAL NETWORKED STATION PORT

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

TRC-190 User s Manual

2 Port DVI Splitter. Model #: SPLIT-DVI

Instruction Guide. 4-Port IEEE 1394 FireWire Card With Digital Video Editing Kit PCI1394_4. The Professionals Source For Hard-to-Find Computer Parts

TRC-190 User s Manual

U.2 (SFF-8643) to M.2 PCI Express 3.0 x4 Host Adapter Card for 2.5 U.2 NVMe SSDs

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

PSA200 User s Manual

3M Constant Monitors WSMONITOR1, WSMONITOR 2, WSMONITOR3

Shop Fox Fence Kit Installation Instructions:

Dell XPS 14z Owner s Manual

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

AOM-S3108M-H8. User's Guide. Revision 1.0

Card Enrollment Station. User Manual UD05870B

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

Installing and Upgrading Memory and Virtual Private Network Modules

AC4G-D User s Manual

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

SMART SWITCH. User s Manual. This product is to be used with the MySmartBlinds automation kit.

Transcription:

Danger This symbol indicates the presence of dangerous voltage within and outside the product enclosure that may constitute a risk of electric shock, serious injury or death to persons if proper precautions are not followed. Caution This symbol alerts the user to the presence of hazards that may cause minor or moderate injury to persons, damage to property or damage to the device itself, if proper precautions are not followed. Note This symbol directs the user s attention to important installation, operating and maintenance instructions. Service Considerations Servicing the ION 7700 meter should only be performed by qualified, competent personnel that have appropriate training and experience with high voltage and current devices. The meter must be serviced in accordance with all Local and National Electrical Codes. DANGER Failure to observe the following instructions may result in severe injury or death. During normal operation of the ION 7700 meter, hazardous voltages are present on its terminal strips, and throughout the connected potential transformer (PT), current transformer (CT), digital (status) input, control power and external I/O circuits. PT and CT secondary circuits are capable of generating lethal voltages and currents with their primary circuit energized. Follow standard safety precautions while performing any installation or service work (i.e. removing PT fuses, shorting CT secondaries, etc). The terminal strips on the meter base should not be user-accessible after installation. Do not use digital output devices for primary protection functions. These include applications where the devices perform energy limiting functions or provide protection of people from injury. Do not use the ION 7700 in situations where failure of the devices can cause injury or death, or cause sufficient energy to be released that can start a fire. The meter can be used for secondary protection functions. Do not HIPOT/Dielectric test the digital (status) inputs, digital outputs, or communications terminals. Refer to the label on the ION 7700 meter for the maximum voltage level the device can withstand. CAUTION Observe the following instructions, or permanent damage to the meter may occur. The ION 7700 meter offers a range of hardware options that affect input ratings. The ION 7700 meter s serial number label lists all equipped options. Applying current levels incompatible with the current inputs will permanently damage the meter. The ION 7700 meter s chassis ground must be properly connected to the switchgear earth ground for the noise and surge protection circuitry to function correctly. Failure to do so will void the warranty. Terminal screw torque: Barrier-type (current, voltage, and relay terminal screws: 1.35 Nm (1.00 ft-lbf) max. Captured-wire type (digital inputs/outputs, communications, power supply: 0.90 Nm (0.66 ft.lbf) max. FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 3

The Ringer Equivalence Number (REN) for the ION 7700 optional internal modem is 0.6. Connection to the ION 7700 internal modem should be made via an FCC Part 68 compliant telephone cord (not supplied). The ION 7700 cannot be used on a public coin phone service or party line services. Network Compatibility Notice for the Internal Modem The internal modem in meters equipped with this option is compatible with the telephone systems of most countries in the world, with the exception of Australia and New Zealand. Use in some countries may require modification of the internal modem s initialization strings. If problems using the modem on your phone system occur, please contact Power Measurement Technical Support Standards Compliance International The 7700 ION is operable under Pollution Degree II Measuring inputs comply with Installation Category III Power Supply inputs comply with Installation Category II All inputs pass ANSI/IEEE C37.90-1989 surge withstand and fast transient tests UL UL listed UL 3111-1 CSA CAN/CSA-C22.2 No.142-M1987 and CAN/SCSA-C22.2 No.1010.1-95 LVD Registered under CB Scheme to EN61010-1:1995 EMC EN50081-2:1994 and EN50082-2:1995 FCC Part 15 of FCC Rules for a Class A Digital Device Limitation of Liability Power Measurement Ltd. ( Power Measurement ) reserves the right to make changes in the device or its specifications identified in this document without notice. Power Measurement advises customers to obtain the latest version of the device specifications before placing orders to verify that the information being relied upon by the customer is current. Regardless of whether any remedy set forth herein fails of its essential purpose, except to the extent the following limitation is prohibited by applicable law, Power Measurement shall not, in any event or under any legal claim or theory (whether based on contract, indemnity, warranty, tort (including negligence and strict liability) or otherwise), be liable to the original purchaser or any other person or entity for special, indirect, incidental, punitive, liquidated, special or consequential damages whatsoever with respect to any purchased product, including, without limitation, business interruption, loss of use, profit or revenue, even if Power Measurement has been advised of the possibility of such damages. To the extent that a limitation or exclusion of consequential damages are prohibited by applicable law, then Power Measurement s liability shall be limited to twice the amount of the relevant purchased product. Not to limit the foregoing, a) Power Measurement shall not be liable for any claim (other than a claim solely for the breach of one of the above Warranties that is made in accordance with the above described procedures) made by the original purchaser, its employees, agents, or contractors for any loss, damage, or expense incurred due to, caused by, or related to any purchased product; and b) the above Warranties are the original purchaser's exclusive remedy and Power Measurement hereby expressly disclaims all other warranties, express or implied, including, without limitation, warranties of non-infringement and the implied warranties of merchantability and fitness for a particular purpose. These limited Warranties shall not apply to any product that has been subject to alteration, accident, misuse, abuse, neglect or failure to exactly follow Power Measurement's instructions for operation and maintenance. Any technical assistance provided by Power Measurement's personnel or representatives in system design shall be deemed to be a proposal and not a recommendation. The responsibility for determining the feasibility of such proposals rests with the original purchaser and should be tested by the original purchaser. It is the original purchaser s responsibility to determine the suitability of any product and associated documentation for its purposes. The original purchaser acknowledges that 100% "up" time is not realizable because of possible hardware or software defects. The original purchaser recognizes that such defects and failures may cause inaccuracies or malfunctions. Only the terms expressed in these limited Warranties shall apply and no distributor, corporation or other entity, individual or employee of Power Measurement or any other entity is authorized to amend, modify or extend the Warranties in any way. The information contained in this document is believed to be accurate at the time of publication, however, Power Measurement assumes no responsibility for any errors which may appear here and reserves the right to make changes without notice. Power Measurement, ION, ION Enterprise, MeterM@il, WebMeter and smart energy everywhere are either registered trademarks or trademarks of Power Measurement. All other trademarks are property of their respective owners. Covered by one or more of the following patents: U.S. Patent No's 6751562, 6745138, 6737855, 6694270, 6671654, 6671635, 6687627, 6615147, 6611922, 6611773, 6563697, 6493644, 6397155, 6186842, 6185508, 6000034, 5995911, 5828576, 5736847, 5650936, D459259, D458863, D443541, D439535, D435471, D432934, D429655, D429533, D427533. 4

Contents Before You Begin........................................ 6 Removing and Replacing the Meter Lid (Xpress Card).............. 7 Replacing the Comm Card.................................. 8 Using the RM Key........................................ 9 Installing the Terminal Strip Cover........................... 11 Installing the ION 7700 Adapter Plate........................ 12 Replacing the MGT Keypad................................ 13 5

Before You Begin DANGER During normal operation of the meter, hazardous voltages are present which can cause severe injury or death. These voltages are present on the terminal strips of the device and throughout the connected potential transformer (PT), current transformer (CT), status input, relay, and control power circuits. Only qualified, properly trained personnel should perform installation and servicing. Before performing any service on the meter: Familiarize yourself with the steps in this guide. Read the safety precautions on the Service Considerations page. Complete the following steps before attempting any retrofits. 1. Turn off ALL power to the meter. 2. Open all PT fuses (or direct voltage input fuses). 3. Close all CT shorting blocks. 4. Ensure that all cables still connected to the meter are NOT live. CAUTION The components inside the meter are extremely sensitive to electrostatic discharge. To prevent damage to the unit, wear an anti-static wrist strap at all times when working inside the unit. Failure to use proper equipment during servicing will void the ION 7700 meter s warranty. Recommended Tools Phillips screwdriver Flat-head screwdriver Adjustable wrench or socket wrench set Wire cutter Anti-static wrist strap or similar protection 6

Removing and Replacing the Meter Lid (Xpress Card) Removing the meter lid/xpress Card 1. Using #2 Phillips screwdriver, remove the four screws from the ION 7700 meter lid. If equipped with an Xpress Card, it is mounted onto the meter lid. 2. Lift the cover straight up to unplug the Xpress card from the main board inside the meter. Replacing the meter lid/xpress Card 1. Line up the Xpress Card edges with the grooves in the meter chassis. Slide down until the edges catches the slot in the main board. Press firmly to plug the card in. 2. Secure the lid onto the chassis using the four screws. 7

Replacing the Comm Card These instructions apply to the standard communications card (with or without the internal modem). 1. Remove the meter lid/xpress Card. The comm card (standard or modem) is located beside the power supply unit. 2. Grasp the comm card and pull straight up to remove it. 3. Ensuring proper orientation, slide the replacement comm card into its slot and press down to plug it in. 4. Replace the meter lid/xpress Card. 8

Using the RM Key The Revenue Meter Programming Key (RMKey) is a device which plugs into the ION 7700 revenue meter and disables its security systems in order to facilitate programming. This key is typically used by utility meter shop personnel who want to program a revenue meter in-house. The RMKey can be used on revenue class ION 7700 meters (-RM, -RMANSI or -RMICAN). The RMKey consists of a 3" x 5" circuit board with a polarized connector (to prevent improper mating). The connector protrudes from the component side. Inserting the RMKey 1. Remove the meter lid. 2. The RMKey plugs into the same socket as the Auxiliary Analog Input Card. If your ION 7700 meter is equipped with an Analog Input Card, carefully remove it first, and set it aside on a static-protected surface. 3. Hold the RMKey by its sides, with the component side facing toward the side closest to the MGT (DB9) connector. Slide the edge of the card along the slot inside the chassis and lower the card toward the VAUX slot. 4. Line up the connector with the socket and plug the RMKey firmly into place. 5. Replace the meter lid/xpress Card. CAUTION Failure to plug the Xpress Card back into the meter will result in loss of configuration data 6. Power up the ION 7700 meter and proceed with programming/ configuration. Note that you cannot delete "locked" modules, even when the RMKey is inserted. 9

Removing the RMKey 1. Remove or disable any power source connected to the meter. 2. Unplug and remove the RMKey to re-enable all meter security systems. 3. If the meter is equipped with the Aux Card, applicable, plug it back into the meter. 4. Replace the meter lid/xpress Card. 5. Install the lead/wire seals through the sealing tabs. 10

Installing the Terminal Strip Cover The terminal strip cover provides an insulation barrier for the wiring terminals. Complete the wiring to the ION 7700 meter s terminal strip, then: 1. Place the terminal strip cover over the terminal strip, arranging the wires so they rest in the slots of the terminal strip cover. Use the mounting screws to secure the terminal strip cover to the meter s first and third vent holes. 2. If a tamperproof seal is required, use the optional sealing can assembly. Secure the sealing can (C) to the terminal cover (A) and meter chassiss using the mounting screw (B). Insert the ball bearing (D), then feed the sealing wire (E) through the hole to secure the ball bearing, and seal the wire ends. Assembled sealing kit 11

Installing the ION 7700 Adapter Plate The ION 7700 adapter plate allows the ION 7700 meter base or MGT to be mounted onto an existing ACM 3000 series mounting hole. Step 1: Remove the existing 3000 series meter Step 2: Resize the panel cut-out Cut away the two areas identified in the following diagram. 49 mm [1.94 ] 186 mm [7.32 ] Cut away 49 mm [1.94 ] Existing cut-out for 3000 series meter. 135 mm [5.30 ] Cut away Panel 31 mm [1.24 ] Step 3: Attach the adapter plate to the meter Use the four nuts to attach the MGT to the Adapter Plate. Place the MGT and attached Adapter Plate into the mounting hole. Use the four hex nuts and lock washers to secure the plate and meter to the panel. If you want to attach your 7700 ION behind the MGT, screw the four aluminum spacers to the four studs provided, then mount the 7700 ION on the spacers. 12

Replacing the MGT Keypad 1. Use a #1 Phillips screwdriver to remove the six screws from the back of the MGT. 2. Remove the display and backlight cables. 13

3. Use a #2 Phillips screwdriver to remove the four MGT circuit board screws. 4. Lift up the MGT circuit board. 5. Unplug the keypad connector. 14

6. Use a small flat screwdriver to pry the corner of the keypad loose. 7. Peel the keypad off the faceplate. 8. The supplied adaptor is required to connect the new keypad connector to the old style header on the MGT circuit board. 15

9. Peel adhesive backing from underneath the keypad connector. This prevents the keypad from lifting up along the edge at this location. 10. Peel the remaining adhesive backing from the keypad. Be careful not to contaminate the adhesive or the LCD window with your fingers. Holding the keypad connector down with one hand, the adhesive backing can be peeled away without touching the back of the keypad. 11. Feed the new keypad connector through the slot in the faceplate. 16

12. Align the bottom corners of the keypad and attach to the faceplate. 13. Align the top corners of the keypad. Apply pressure over the entire surface of the keypad to firmly attach it to the faceplate. 14. Attach the adapter to the keypad connector, as shown, with the white connector facing you. Insert the keypad tail completely inside the adapter connector. 17

15. Lock the connector in place. Pull gently to make sure it is locked firmly; the adapter should not slip. 16. Attach the keypad adapter to the MGT circuit board as shown and make sure the connector is completely seated. 17. Reposition MGT circuit board onto the four standoffs. 18

18. Reattach the backlight connector; this connector is keyed and can be plugged in only the correct way. 19. Reattach display connector; be careful to line up the header properly. 20. Replace the four screws to fasten the MGT circuit board to the faceplate. Replace the back cover, and fasten the six screws. Your MGT is now ready 19

For further assistance please contact us at: Worldwide Headquarters 2195 Keating Cross Road Saanichton, BC Canada V8M 2A5 Tel: 1-250-652-7101 Fax: 1-250-652-0411 Email: support@pwrm.com www.pwrm.com 2004 Power Measurement Printed in Canada MRP: 70050-0199-00 Revision Date: Oct 4, 2004