Network Operations Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Similar documents
Society of Cable Telecommunications Engineers

Network Operations Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Network Operations Subcommittee AMERICAN NATIONAL STANDARD

ENGINEERING COMMITTEE Data Standards Subcommittee AMERICAN NATIONAL STANDARD

ENGINEERING COMMITTEE Hybrid Management Sub-Layer Subcommittee AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD

ANSI/SCTE

ANSI/SCTE

ENGINEERING COMMITTEE Digital Video Subcommittee

ANSI/SCTE

AMERICAN NATIONAL STANDARD

Audio/Video Working Group. Nortel March 2006

Internet Engineering Task Force (IETF) B. Claise Cisco Systems, Inc. G. Muenz Technische Universitaet Muenchen April 2010

ENGINEERING COMMITTEE Digital Video Subcommittee SCTE Digital Program Insertion Advertising Systems Interfaces.

Network Working Group. Intended status: Standards Track. January 15, 2010

ENGINEERING COMMITTEE Digital Video Subcommittee SCTE Digital Program Insertion Advertising Systems Interfaces. Part 4

Feb :33 draft-glenn-id-sensor-alert-mib-01.txt Page 1

A. Kessler Cisco Systems December 2007

Network Working Group. Category: Standards Track June Protocol Independent Multicast (PIM) Bootstrap Router MIB

Cable Facility Classification Definitions and Requirements

Cisco Management Information Base

Network Working Group. Caymas Systems, Inc. R. Raghunarayan N. Pai Cisco Systems, Inc. C. Wang Bank One Corp March 2005

Network Working Group Request for Comments: 4131 Category: Standards Track Toshiba E. Cardona, Ed. CableLabs A. Katsnelson September 2005

Internet Engineering Task Force (IETF) Category: Standards Track. S. Sivakumar Cisco Systems T. Taylor PT Taylor Consulting October 2015

The Marway Chassis MIB. Status of this Memo. This document specifies a proprietary MIB module of Marway Power Solutions.

AMERICAN NATIONAL STANDARD

Internet Engineering Task Force (IETF) Request for Comments: ISSN: April 2014

Network Operations Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Network Working Group. Category: Standards Track Tohoku University K. Nagami INTEC NetCore Inc. S. Gundavelli Cisco Systems Inc.

Obsoletes: 4369 March 2011 Category: Standards Track ISSN: Definitions of Managed Objects for the Internet Fibre Channel Protocol (ifcp)

Request for Comments: 4672 Category: Informational M. Chiba Cisco Systems, Inc. September 2006

Network Working Group. Category: Standards Track Hewlett-Packard T. McSweeney IBM J. Muchow Qlogic Corp. May 2006

ANSI/SCTE

Intended status: Standards Track Expires: April 27, 2015 Q. Zhao Huawei Technology D. King Old Dog Consulting J. Hardwick Metaswitch October 24, 2014

Internet Engineering Task Force (IETF) Request for Comments: 5907 Category: Standards Track ISSN: B. Haberman, Ed.

Internet Engineering Task Force (IETF)

ETSI TS V1.1.1 ( ) Technical Specification

Network Working Group. Category: Standards Track. ArrowPoint Communications A. Sastry. Cisco Systems. September 1997

Internet Engineering Task Force (IETF) Category: Standards Track. S. Gundavelli Cisco R. Wakikawa Toyota ITC May 2012

Network Working Group Request for Comments: J. Lang Sonos, Inc. E. McGinnis Hammerhead Systems January 2006

Request for Comments: 5488 Category: Standards Track. Network Mobility (NEMO) Management Information Base

Network Working Group. Category: Standards Track Black Storm Networks R. Wheeler DoubleWide Software August 2002

Request for Comments: 2493 Category: Standards Track January 1999

Intended Status: Proposed Standard. Proxy Mobile IPv6 Management Information Base <draft-ietf-netlmm-pmipv6-mib-03.txt>

Internet Engineering Task Force (IETF) Y. Zhang, Ed. Fortinet, Inc. May 2010

NAFEM Data Protocol Standard

Author of previous version: B. Stewart November 2000

Category: Standards Track September MIB Textual Conventions for Uniform Resource Identifiers (URIs)

Network Working Group Request for Comments: 3559 Category: Standards Track June 2003

TCG. SNMP MIB for TPM-Based Attestation

Network Working Group. Category: Standards Track June 2007

Category: Standards Track. Arastra, Inc D. McWalter Data Connection Ltd B. Joshi Infosys Technologies Ltd A. Kessler. Cisco Systems.

Network Working Group. January 2008

Request for Comments: Accton Technology Corporation February Definitions of Managed Objects for Fibre Channel Over TCP/IP (FCIP)

SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Communication procedures

NICC ND 1635 V 1.1.1( )

ENGINEERING COMMITTEE Network Operations Subcommittee SCTE STANDARD SCTE

INTERNATIONAL STANDARD

Cisco Call Management Record Field

IP SLAs Overview. Finding Feature Information. Information About IP SLAs. IP SLAs Technology Overview

BGP/MPLS Layer 3 VPN Multicast Management Information Base

Definitions of Managed Objects for Mapping of Address and Port with Encapsulation (MAP-E)

DESCRIPTION "This revision is being published as part of the third update of the Packetcable Signaling MIBs enhancements for PacketCable 1.5.

Network Working Group Request for Comments: 4150 Category: Standards Track JHU/APL August 2005

SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Communication procedures

SOCIETY OF CABLE TELECOMMUNICATIONS ENGINEERS, INC.

Lecture 5: Foundation of Network Management

Internet Engineering Task Force (IETF) Category: Standards Track. K. Patel Cisco Systems M. Baer SPARTA May 2013

Request for Comments: Oversi O. Nicklass, Ed. RADVISION May Definitions of Textual Conventions for Pseudowire (PW) Management

Internet Engineering Task Force. Intended status: Standards Track. May 3, 2009

CHAPTER. Introduction

TA Document SMPTE Time Code and Sample Count Transmission Protocol Ver.1.0

Category: Standards Track December 1998

INTERNATIONAL STANDARD

Investigation of Algorithms for VoIP Signaling

Category: Standards Track Texas Instruments S. Channabasappa CableLabs February 2008

OPEN BASE STATION ARCHITECTURE INITIATIVE

ANSI/SCTE

Category: Standards Track July 2002

Discontinuous Transmission (DTX) of Speech in cdma2000 Systems

HP 830 Series PoE+ Unified Wired-WLAN Switch Switching Engine

Lecture 18: Network Management

The Marway Sensor MIB. Status of this Memo. This document specifies a proprietary MIB module of Marway Power Solutions.

Technical Committee. Loop Detection Version1.0. af-cs

AES standard for digital audio Digital input-output interfacing Transmission of ATM cells over Ethernet physical layer.

AMERICAN NATIONAL STANDARD

Old Dog Consulting February Generalized Multiprotocol Label Switching (GMPLS) Traffic Engineering Management Information Base

Why Next-Generation Voice Services Need Next-Generation KPIs

Troubleshooting VoWLAN using OmniPeek

Technical Specification MEF 27. Abstract Test Suite For. May 20 th, 2010

TA Document Transmission of Rec. ITU-R BO.1294 System B Transport 1.0

Internet Engineering Task Force (IETF) Category: Standards Track. J. Quittek. NEC Europe Ltd. October 2012

Avaya ExpertNet Lite Assessment Tool

Avaya Inc. K.C. Norseth L-3 Communications December 2002

TECHNICAL SPECIFICATION

OPEN BASE STATION ARCHITECTURE INITIATIVE

Internet Engineering Task Force (IETF) Request for Comments: 7330 Category: Standards Track. Cisco Systems August 2014

This is a preview - click here to buy the full publication

INTERNATIONAL STANDARD

ND1009:2002/05 PNO-ISC/SPEC/009

Transcription:

Network Operations Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 131 2017 HMS VoIP Test Management Information Base (MIB) Definition SCTE-HMS-VOIP-MIB

NOTICE The Society of Cable Telecommunications Engineers (SCTE) / International Society of Broadband Experts (ISBE) Standards and Operational Practices (hereafter called documents ) are intended to serve the public interest by providing specifications, test methods and procedures that promote uniformity of product, interchangeability, best practices and ultimately the long-term reliability of broadband communications facilities. These documents shall not in any way preclude any member or non-member of SCTE ISBE from manufacturing or selling products not conforming to such documents, nor shall the existence of such standards preclude their voluntary use by those other than SCTE ISBE members. SCTE ISBE assumes no obligations or liability whatsoever to any party who may adopt the documents. Such adopting party assumes all risks associated with adoption of these documents, and accepts full responsibility for any damage and/or claims arising from the adoption of such documents. Attention is called to the possibility that implementation of this document may require the use of subject matter covered by patent rights. By publication of this document, no position is taken with respect to the existence or validity of any patent rights in connection therewith. SCTE ISBE shall not be responsible for identifying patents for which a license may be required or for conducting inquiries into the legal validity or scope of those patents that are brought to its attention. Patent holders who believe that they hold patents which are essential to the implementation of this document have been requested to provide information about those patents and any related licensing terms and conditions. Any such declarations made before or after publication of this document are available on the SCTE ISBE web site at http://www.scte.org. All Rights Reserved Society of Cable Telecommunications Engineers, Inc. 2017 140 Philips Road Exton, PA 19341 AMERICAN NATIONAL STANDARD SCTE ISBE 2

Contents 1. SCOPE 4 2. COPYRIGHT 4 3. NORMATIVE REFERENCES 4 4. INFORMATIVE REFERENCES 4 5. TERMS AND DEFINITION 4 6. REQUIREMENTS 5 AMERICAN NATIONAL STANDARD SCTE ISBE 3

1. Scope This document is identical to SCTE 131 2007 except for informative components which may have been updated such as the title page, NOTICE text, headers and footers. No normative changes have been made to this document. This document provides MIB definitions for VoIP testing between two endpoints. It allows an HMS/DOCSIS transponder or any other device that implements it to be used as a test point to validate VoIP service in the network and to report a common basic set of measurements. 2. Copyright The MIB definition found in this document may be incorporated directly in products without further permission from the copyright owner, SCTE. 3. Normative References 3.1. SCTE Standards ANSI/SCTE 37 2002 SCTE-HMS-ROOTS 3.2. Standards from other Organizations IETF RFC 3550 RTP: A Transport Protocol for Real-Time Applications ITU-T P.800 ITU-T G.107 The E-model, a computational model for use in transmission planning (12/03) 4. Informative References The following documents may provide valuable information to the reader but are not required when complying with this standard: ITU-T G.711 Pulse code modulation (PCM) of voice frequencies IETF RFC 2578 SNMPv2-SMI IETF RFC 2579 SNMPv2-TC IETF RFC 2580 SNMPv2-CONF IETF RFC 4133 ENTITY-MIB IETF RFC 4001 INET-ADDRESS-MIB IETF RFC 3411 SNMP-FRAMEWORK-MIB 5. Terms and Definition This document defines the following terms: Management Information Base (MIB) - the specification of information in a manner that allows standard access through a network management protocol. AMERICAN NATIONAL STANDARD SCTE ISBE 4

6. Requirements This section defines the mandatory syntax of the SCTE-HMS-VOIP-MIB. It follows the IETF Simple Network Management Protocol (SNMP) for defining the managed objects. The syntax is given below. AMERICAN NATIONAL STANDARD SCTE ISBE 5

SCTE-HMS-VOIP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, enterprises, Counter32, Unsigned32 FROM SNMPv2-SMI OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC SnmpAdminString FROM SNMP-FRAMEWORK-MIB InetAddress, InetAddressType, InetPortNumber FROM INET-ADDRESS-MIB voipident FROM SCTE-HMS-ROOTS; voipmodulemib MODULE-IDENTITY LAST-UPDATED "200701291300Z" ORGANIZATION "SCTE HMS Subcommittee" CONTACT-INFO "SCTE HMS Subcommittee, Chairman mail to: standards@scte.org " "This MIB module, contains the interface for the hms VoIP testing specification. It allows an HMS/DOCSIS transponder or any other device that implements it to be used as a test point to validate VoIP service in the network and to report a common basic set of measurements. Theory Of operation: The device controlled by this MIB is called an endpoint. Each AMERICAN NATIONAL STANDARD SCTE ISBE 6

endpoint sends or receives a test stream to/from another test endpoint. A measurement application is responsible for controlling both endpoints to setup compatible test streams and to gather results. An endpoint can implement a number simultaneous test streams (reported in voipmaxtestinstance). Each test stream is controlled by a separate entry in the voiptestcontroltable. This table contains a series of controls that enable the server to set VoIP tests The purpose of such a test is to simultate an RTP VoIP connection and estimate the equivalent call quality between two known points in the network. From the endpoint's perspective's, each test stream has three possible directions: transmission, reception or loopback. The direction is inferred from the voiptestcontrolsenderaddress & voiptestcontrolreceiveraddress MIBs. The endpoint will detect its address in one of the two MIB and set itself up accordingly. When none of the two MIB contains the endpoint's address, a mirror (loopback) mode is used." ::= { enterprises scteroot(5591) sctehmstree (1) voipident (12) voiptestgroup (1) 1} -- -- TEXTUAL CONVENTIONS used by this MIB -- Rfactor ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" "Call or transmission quality expressed as an R factor in the range 0 to 120. A value of 127 shall be interpreted as NULL or unsupported." AMERICAN NATIONAL STANDARD SCTE ISBE 7

REFERENCE "ITU-T G.107" SYNTAX Unsigned32 (0..120 127) ScaledMOSscore ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" "Call or transmission quality expressed as a MOS score scaled by 10. MOS is typically represented as a 1.0 to 5.0 score with a single decimal place and hence in this representation as 10 to 50. A value of 127 shall be interpreted as NULL or unsupported." REFERENCE "ITU-T P.800" SYNTAX Unsigned32 (10..50 127) -- -- voipident MIb Branch root -- voipmibobjects OBJECT IDENTIFIER ::= { voipmodulemib 1 } voipversion OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) "Displays the version of the specification running on this endpoint" ::= { voipmibobjects 1 } AMERICAN NATIONAL STANDARD SCTE ISBE 8

voipmaxtestinstance OBJECT-TYPE SYNTAX Unsigned32 "The number of concurrent tests supported by this endpoint." ::= { voipmibobjects 2 } -- -- Test Mibs -- voiptest OBJECT IDENTIFIER ::= { voipmibobjects 3 } -- -- Test Control table -- voiptestcontroltable OBJECT-TYPE SYNTAX SEQUENCE OF VoipTestControlEntry MAX-ACCESS not-accessible "Table of Test Controls Each entry is used to control a test instance. Tests parameters shall be inputed to the endpoint first, then the voiptestcontrol MIB must be set the setuptest value and Ready status verified before starting a test." ::= { voiptest 1 } voiptestcontrolentry OBJECT-TYPE AMERICAN NATIONAL STANDARD SCTE ISBE 9

SYNTAX VoipTestControlEntry MAX-ACCESS not-accessible "An entry in the Table of Test Control. There will be one entry per supported simultaneous tests." INDEX {voiptestcontrolindex} ::= { voiptestcontroltable 1 } VoipTestControlEntry ::= SEQUENCE { voiptestcontrolindex Unsigned32, voiptestcontrolidstring SnmpAdminString, voiptestcontrol INTEGER, voiptestsenderaddresstype InetAddressType, voiptestsenderaddress InetAddress, voiptestsenderudpport InetPortNumber, voiptestreceiveraddresstype InetAddressType, voiptestreceiveraddress InetAddress, voiptestreceiverudpport InetPortNumber, voiptestpacketinterval Unsigned32, voiptestnumofpackets Unsigned32, voiptestjitterbuffersize Unsigned32, voiptestcodectype OCTET STRING, voiptestroundtriptimeestimate Unsigned32 } voiptestcontrolindex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible "Index for this set of test controls. AMERICAN NATIONAL STANDARD SCTE ISBE 10

One set controls one instance of the test." ::= {voiptestcontrolentry 1} voiptestcontrolidstring OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) MAX-ACCESS read-write "This String can be used by the management entity as a unique test identifier string." ::= {voiptestcontrolentry 2} voiptestcontrol OBJECT-TYPE SYNTAX INTEGER { stoptest(1), setuptest(2), starttest(3) } MAX-ACCESS read-write "Used to control the test engine. Once the control parameter for the test are set, the management entity must set this to setuptest(2) & verify that the test control status returns ready before starting the test with starttest(2). This is necessary to reserve the resources required for the tests such as service flows, etc. The test will run a for maximum number of packets (voiptestnumofpackets), or it can be stopped at any time by setting this MIB to stoptest(1)." ::= {voiptestcontrolentry 3} AMERICAN NATIONAL STANDARD SCTE ISBE 11

voiptestsenderaddresstype OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-write "This is the address type of the sender endpoint for the test stream. To set this device as the transmitter for the test, set this MIB to its address." ::= {voiptestcontrolentry 4} voiptestsenderaddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write "This is the address of the sender endpoint for the test stream. To set this device as the transmitter for the test, set this MIB to its address." ::= {voiptestcontrolentry 5} voiptestsenderudpport OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-write " Port Number that the sender will use. In loopback mode this port number is used as the destination address by the loopbacking entity, it may also be used as the source port for the generating entity." ::= {voiptestcontrolentry 6} voiptestreceiveraddresstype OBJECT-TYPE AMERICAN NATIONAL STANDARD SCTE ISBE 12

SYNTAX InetAddressType MAX-ACCESS read-write "This is the address of the receiving endpoint for this test stream. To set this device as the receiver for the test, set this MIB to its IP address. If both voiptestreceiverip & voiptestsenderip do not match the endpoint's own address, it will start a loopback mode test." ::= {voiptestcontrolentry 7} voiptestreceiveraddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write "This is the address of the receiving endpoint for this test stream. To set this device as the receiver for the test, set this MIB to its IP address. If both voiptestreceiverip & voiptestsenderip do not match the endpoint's own address, it will start a loopback mode test." ::= {voiptestcontrolentry 8} voiptestreceiverudpport OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-write " UDP port number to be used by the receiving entity. In loopback mode, the receiver Port number is also used as both AMERICAN NATIONAL STANDARD SCTE ISBE 13

the reception and source port of the loopbacking entity." ::= {voiptestcontrolentry 9} voiptestpacketinterval OBJECT-TYPE SYNTAX Unsigned32 (10 20 30) UNITS "milliseconds" MAX-ACCESS read-write "Interval in milliseconds between each packets. This MIB MUST be set to a voip standard 10, 20, or 30 ms interval." DEFVAL {10} ::= {voiptestcontrolentry 10 } voiptestnumofpackets OBJECT-TYPE SYNTAX Unsigned32 (0..86400000) MAX-ACCESS read-write "Maximum duration of the test expressed in number of packets. A sender will stop the transmitting when it reaches this amount. A receiver can use this parameter to know how many packets to expect. The test can be stopped by the management entity before that number is reached." ::= {voiptestcontrolentry 11} voiptestjitterbuffersize OBJECT-TYPE SYNTAX Unsigned32 (0..500) AMERICAN NATIONAL STANDARD SCTE ISBE 14

MAX-ACCESS read-write "Jitter buffer size in millisecond to be implemented by the receiving endpoint. This will impact the total delay and the discarded packet count." DEFVAL {20} ::= {voiptestcontrolentry 12} voiptestcodectype OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-write "The Codec type to be used for the voip test. It is used by sender to set the appropriate value in the rtp header. The receiver can use this parameter in the computation of the R-Factor. Note that the list of supported codecs is device specific. The format used shall be ITU-T G.7xx or similar. Each endpoint must at least support the ITU-T G.711 codec." ::= {voiptestcontrolentry 13 } voiptestroundtriptimeestimate OBJECT-TYPE SYNTAX Unsigned32 (0..60000) UNITS "milliseconds" MAX-ACCESS read-write AMERICAN NATIONAL STANDARD SCTE ISBE 15

"The round trip time (in milliseconds) is used by the receiving endpoint in the computation of the CQE R-Factor. It must be estimated by the management entity and supplied to the endpoint via the use of this MIB for the RCQE result to be accurate. Note that the one way delay used by the endpoint in its computation will be RoundTripTime / 2. Writing a value of zero to this MIB will cause the round-trip delay to be NULL and the resulting R-Factor will be Listening Quality Equivalent (LQE)" ::= {voiptestcontrolentry 14} -- -- Test Result table -- voiptestresulttable OBJECT-TYPE SYNTAX SEQUENCE OF VoipTestResultEntry MAX-ACCESS not-accessible "Table of Test Results Each entry is used to display the results a test instance." ::= { voiptest 2 } voiptestresultentry OBJECT-TYPE SYNTAX VoipTestResultEntry AMERICAN NATIONAL STANDARD SCTE ISBE 16

MAX-ACCESS not-accessible "An entry in the Table of Test Control. There will be one entry per supported simultaneous tests." INDEX {voiptestresultindex} ::= { voiptestresulttable 1 } VoipTestResultEntry ::= SEQUENCE { voiptestresultindex Unsigned32, voiptestresultidstring SnmpAdminString, voipteststatus INTEGER, voipteststatusstring SnmpAdminString, voiptestduration Unsigned32, voipteststarttime DateAndTime, voipteststoptime DateAndTime, voiptestprocessedpacketcount Counter32, voiptestlosspacketcount Counter32, voiptestdiscardedpacketcount Counter32, voiptestminjitterlevel Counter32, voiptestmaxjitterlevel Counter32, voiptestavgjitterlevel Counter32, voiptestrfactor Rfactor, voiptestmos ScaledMOSscore } voiptestresultindex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible AMERICAN NATIONAL STANDARD SCTE ISBE 17

"Index for this set of test controls. One set controls one instance of the test." ::= {voiptestresultentry 1} voiptestresultidstring OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) "This String is copied over from the associated control table entry identifier string." ::= {voiptestresultentry 2} voipteststatus OBJECT-TYPE SYNTAX INTEGER { na(0), running(1), completed(2), resourceunavailable(3), invalidparameter(4), ready(5), other(6) } "This MIB indicates the test status. A value of N/A(0) is returned before the test is run. A value of Running (1) is returned while the test is in progress. A value of Completed (2) is returned when the test is stopped by AMERICAN NATIONAL STANDARD SCTE ISBE 18

the TestControl MIB or by the end-point when the voiptestnumofpackets is reached. A value of ResourceUnavailable (3) is returned when the end-point is not able to start the test due to internal or network limitations. A value of InvalidParameters(4) is returned if the test parameters cannot be accepted by the end-point. A value of Ready(5) is reported if the SetUpTest command succeeded. A value of other(6) is a device specific error code. When other(6) is reported, a custom error message is reported in the voipteststatusstring." ::= {voiptestresultentry 3} voipteststatusstring OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) "This field is used by the device to further explain the Status of the test. and its content is device specific. " ::= {voiptestresultentry 4} voiptestduration OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" AMERICAN NATIONAL STANDARD SCTE ISBE 19

"Total Duration of the test in milliseconds. " ::= { voiptestresultentry 5 } voipteststarttime OBJECT-TYPE SYNTAX DateAndTime "System time at the beginning of the test. " ::= { voiptestresultentry 6 } voipteststoptime OBJECT-TYPE SYNTAX DateAndTime "System time at the end of the test. The value of this MIB is valid only if the voipteststatus is complete(2) " ::= { voiptestresultentry 7 } voiptestprocessedpacketcount OBJECT-TYPE SYNTAX Counter32 "Total number of packets that have been processed by the AMERICAN NATIONAL STANDARD SCTE ISBE 20

endpoint. In transmission this indicates the number of packets sent In reception this is the sum of the good packets and the discarded packets." ::= { voiptestresultentry 8 } voiptestlosspacketcount OBJECT-TYPE SYNTAX Counter32 "Number of packets lost in the network before their arrival to this endpoint. The value reported by this MIB is valid only in the receiving endpoint. The sending endpoint shall report zero. " ::= { voiptestresultentry 9 } voiptestdiscardedpacketcount OBJECT-TYPE SYNTAX Counter32 "Number of packets discarded by this device because they arrived too late or too early to be played out by the codec. The value reported by this MIB is valid only in the receiving endpoint. " ::= { voiptestresultentry 10 } AMERICAN NATIONAL STANDARD SCTE ISBE 21

voiptestminjitterlevel OBJECT-TYPE SYNTAX Counter32 "Mimimum of the Jitter level computed as per rfc3550. The value reported by this MIB is valid only in the receiving endpoint. " ::= { voiptestresultentry 11 } voiptestmaxjitterlevel OBJECT-TYPE SYNTAX Counter32 "Maximum of the Jitter level computed as per rfc3550. The value reported by this MIB is valid only in the receiving endpoint. " ::= { voiptestresultentry 12 } voiptestavgjitterlevel OBJECT-TYPE SYNTAX Counter32 "Average of the Jitter level computed as per rfc3550. AMERICAN NATIONAL STANDARD SCTE ISBE 22

The value reported by this MIB is valid only in the receiving endpoint. " ::= { voiptestresultentry 13 } voiptestrfactor OBJECT-TYPE SYNTAX Rfactor "Computed R-Factor - Conversationnal Quality Equivalent as per ITU G.107 The value reported by this MIB is valid only in the receiving endpoint. " ::= { voiptestresultentry 14 } voiptestmos OBJECT-TYPE SYNTAX ScaledMOSscore "Computed MOS - Conversationnal Quality Equivalent as per ITU G.107 The value reported by this MIB is valid only in the receiving endpoint. " AMERICAN NATIONAL STANDARD SCTE ISBE 23

::= { voiptestresultentry 15 } -- -- hmsvoip Conformance / Compliance statements -- voipmibconformance OBJECT IDENTIFIER ::= { voipmodulemib 2 } voipmibcompliances OBJECT IDENTIFIER ::= { voipmibconformance 1 } voipmibgroups OBJECT IDENTIFIER ::= { voipmibconformance 2 } -- Compliance statements voipcompliances MODULE-COMPLIANCE STATUS current MODULE "The minimum compliance statement for VOIP Testing." MANDATORY-GROUPS { voipmibobjectsgroup, voiptestcontrolgroup, voiptestresultgroup } ::= { voipmibcompliances 1 } -- this module voipmibobjectsgroup OBJECT-GROUP OBJECTS { voipversion, voipmaxtestinstance } "voipmibobjectsgroup defines mandatory objects of the voipmibobjects mib." ::= { voipmibgroups 1 } voiptestcontrolgroup OBJECT-GROUP AMERICAN NATIONAL STANDARD SCTE ISBE 24

OBJECTS { voiptestcontrolidstring, voiptestcontrol, voiptestsenderaddresstype, voiptestsenderaddress, voiptestsenderudpport, voiptestreceiveraddresstype, voiptestreceiveraddress, voiptestreceiverudpport, voiptestpacketinterval, voiptestnumofpackets, voiptestjitterbuffersize, voiptestcodectype, voiptestroundtriptimeestimate } STATUS current "voiptestcontrolgroup defines mandatory objects of the voiptestcontroltable." ::= { voipmibgroups 2 } voiptestresultgroup OBJECT-GROUP OBJECTS { voiptestresultidstring, voipteststatus, voipteststatusstring, voiptestduration, voipteststarttime, voipteststoptime, voiptestprocessedpacketcount, voiptestlosspacketcount, voiptestdiscardedpacketcount, voiptestminjitterlevel, voiptestmaxjitterlevel, AMERICAN NATIONAL STANDARD SCTE ISBE 25

voiptestavgjitterlevel, voiptestrfactor, voiptestmos } STATUS current "voiptestcontrolgroup defines mandatory objects of the voiptestresulttable." ::= { voipmibgroups 3 } END AMERICAN NATIONAL STANDARD SCTE ISBE 26