Digitrip 520MC with Maintenance Mode

Similar documents
Digitrip 1150 with Maintenance Mode

Instructions for Testing Magnum DS Trip Units Using PACB Test Kit Styles 87C0270G01-G03

Time delay undervoltage module

Series NRX drawout circuit breaker and cassette rejection interlocks

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN

COOPER POWER SERIES. Visible-Break switch accessory operation instructions. Padmounted switchgear MN285011EN

INSTRUCTIONS FOR THE IQ DC POWER SUPPLY INSTRUCTION LEAFLET IL E

INCOM communications adapter module

Power Xpert Meter 2000 Series

Cutler-Hammer. Westinghouse Transfer Switch Equipment. IQ Transfer

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

COOPER POWER SERIES. DC motor operator control installation and operation instructions. Padmounted Switchgear MN285018EN

Installer Guide. About SecureConnect. Contents. About this guide. Eaton SecureConnect. About the web portal

Eaton Innovative TechnologyT XT50/100 surge protective device

COOPER POWER SERIES. Ethernet communications module installation and operation instructions. Voltage Regulators MN225033EN

COOPER POWER SERIES. Fiber-optic/RS-232 communications module installation and operation instructions. Voltage Regulators MN225020EN

LP800 Loop Tester. Installation and Operation Manual

Instructions for installation, operation and maintenance of the Arc Quenching Device (AQD)

Single Phase Vacuum Capacitor Switch. UltraVacLT 15kV 95kV or 125kV BIL

for the SPV Installation and Operation Manual Instruction Manual IM E Contents

Intelligent Technologies

Conext CL-60 Inverter Firmware Upgrade Process

E-Series Troubleshooting Guide

Wall. No opening (Example: LA-030-W)

Wa r n i n g-wa r n i n g-wa r n i n g

Multi Unit Enclosed Meter

SATA II HDD Canister KISS DA 435 Quick Reference Guide

EDR-3000 Eaton Distribution Relay

O & M Manual for the Eaton ATC-100 Automatic Transfer Switch Controller

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

Instruction Manual IM E Table of Contents

EH E Effective February 2018 Foreseer 7. Foreseer Release Notes

FTC-200 X-ray Tube Controller Users Manual

Upgrading BankLink Books

Broadband Automatic Disconnect Switch. User Manual

ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply

Cutler-Hammer. Instructions for Installation, Operation and Maintenance of Cutler-Hammer IQ Analyzer Electrical Distribution System Monitor TD 17530A

COOPER POWER SERIES. Form 4C microprocessor-based recloser control standard and automation power supply kit installation and operation instructions

Instruction Manual: IM E

Shutter Assembly Guide Frame Accessory

MySonicWall Secure Upgrade Plus

CAUTION This device is sensitive to ElectroStatic Discharge (ESD). Therefore care should be taken during transport and handling.

I.B. 29C893C. Instructions for Installation, Operation and Maintenance of Breaker Interface Module II

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

EVB-USB2517 Evaluation Board User Manual (Revision A)

quick setup Plug the keyboard into your computer. For: Windows Linux Mac OS X 10.3 or earlier For: Mac OS X 10.4 or later

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

End User License Agreement

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

Programmable USB Port Power Controller with Charger Emulation

EMC2113. RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown PRODUCT FEATURES. General Description.

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

OPERATOR MANUAL for the Kodak X-Omatic IDENTIFICATION CAMERA MODELS 4, 4L, and 4SL

User s Guide. POWERVAR Single Phase Power Conditioners

Zonit μats TM Users Guide μats1-lv Version 1.2

LM5022 Isolated Flyback Converter

LAN9512 Evaluation Board User Manual

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

ADDENDUM TO IB17555D INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER DIGITRIP 3000 SERIES OF PROTECTIVE RELAYS

Install Motor Controller User Manual

Single Cell Battery Power Solution

OPERATION MANUAL BO BLASTER S OHMMETER

EVB-USB2250 User Manual Revision B

Indicator (Square) Ultra Bright LED Type

USB2507. Integrated USB 2.0 Compatible 7-Port Hub PRODUCT FEATURES. Data Brief

EVB-USB2640 Evaluation Board Revision A

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

Indicator (Square) Ultra Bright LED Type

Policies & Medical Disclaimer

NEMA Standards Publication AB Establishing Levels of Selective Coordination for Low Voltage Circuit Breakers

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

UM NVT2008PW and NVT2010PW demo boards. Document information

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

EVB-USB82640 Evaluation Board Revision A User Manual

AT60142H/HT. Rad-Hard 512Kx8 Very Low Power CMOS SRAM ERRATA-SHEET. Active Errata List. Errata History. Abbreviations. 1.

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

Applying branch circuit breakers and supplementary protectors in North America

AC4G-D User s Manual

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

For the LAN91C111 TQFP package, the Vdd and AVdd pins are located as follows: Pin #1, #11, #16, #33, #44, #62, #77, #98, #110, #120.

Logitech Alert 700i/750i System Requirements & Support Guide

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

Bluetooth USB User Guide. Revision A July 12, 2006 Part Number GC

Woolich Racing. USB ECU Interface User Guide

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT

Remote Refrigeration Control

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

INSTALLATION INSTRUCTIONS

Redirector User Guide

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

For use with QED controls panels ONLY

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

UM NVT2001GM and NVT2002DP demo boards. Document information

SonicWall Mobile Connect for Chrome OS

QPP Proprietary Profile Guide

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Transcription:

Digitrip 520MC with Maintenance Mode Effective May 2006 I.S 70C1454 Supplement to I.L. 70C1037 FIGURE 1. Digitrip 520MC with ARMs in Magnum Circuit Breaker Table of Contents 1.0 General... 2 2.0 Maintenance Mode Settings... 2 3.0 Arming Maintenance Mode... 2 4.0 Remote Indicator... 3 5.0 Choosing the Reduction Setting... 4 6.0 Tripping and Testing... 4 Wiring Diagram... 5 Manufacturer s Statement... 6 EATON CORPORATION Cutler-Hammer InformationSheets 70C1454H02 1

WARNING ONLY CERTIFIED AND COMPETENT PERSONNEL SHOULD ATTEMPT TO INSTALL OR MAINTAIN POTENTIALLY HAZARDOUS EQUIPMENT. DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENERGIZED. DEATH OR SEVERE PERSONAL INJURY CAN RESULT FROM CONTACT WITH ENERGIZED EQUIPMENT. ALWAYS VERIFY THAT NO VOLTAGE IS PRESENT BEFORE PROCEEDING. ALWAYS FOLLOW SAFETY PROCEDURES. EATON IS NOT LIABLE FOR THE MISAPPLICATION OR MISINSTALLATION OF ITS PRODUCTS. 1.0 General Per the above WARNING, it is highly recommended that maintenance be conducted on electrical equipment including circuit breakers with the system de-energized. For situations that arise where this is not possible, the Maintenance Mode function of the Digitrip 520MC family (cat 5ARMLSI, 5ARMLSIG, 5ARMLSIA) can reduce Arc Flash incident energy that is generated on a fault condition. This is accomplished by a analog trip circuit which, when armed, provides a fast acting response to the fault. The reduced arc condition will occur only in devices downstream of the trip unit in Maintenance Mode. This is separate from the normal system protection setting of Instantaneous. The Maintenance Mode is located in the upper, white portion of the unit. 2.0 Maintenance Mode Settings CAUTION OBSERVE ALL RECOMMENDATIONS, NOTES, CAU- TIONS, AND WARNINGS RELATING TO THE SAFETY OF PERSONNEL AND EQUIPMENT. OBSERVE AND COMPLY WITH ALL GENERAL AND LOCAL HEALTH AND SAFETY LAWS, CODES, AND PROCEDURES. The Maintenance Mode Settings (labeled R5, R4, R3, R2, R1) provide the Arc Flash Reduction setting. R5 is the Maximum reduction setting which correlates to the lowest pickup value. Nominal Trip current of Maintenance Mode Settings Setting R5 2.5x Rating Plug Amperes CAUTION Setting R4 Setting R3 Setting R2 Setting R1 4.0x Rating Plug Amperes 6.0x Rating Plug Amperes 8.0x Rating Plug Amperes 10x Rating Plug Amperes A FLASH HAZARD ANALYSIS SHOULD BE DONE TO DETERMINE PERSONAL PROTECTIVE EQUIPMENT REQUIREMENTS 3.0 Arming Maintenance Mode There are three ways to arm the Maintenance Mode Arc Flash Reduction setting. One method is locally via the two position switch in the Maintenance Mode section of the trip unit. Turning the switch to the ON position will arm the setting selected. A blue LED confirms that the function is on. 2 EATON CORPORATION Cutler-Hammer Information Sheets 70C1454H02

FIGURE 2. Digitrip 520MC with ARMs For the other two methods of arming the Maintenance Mode function, this switch must be in the position labeled 0/1.With this setting, a remote switch wired through the breaker secondary contacts can remotely arm the Maintenace Mode setting. A high quality, gold plated or palladium contact is required in this application.the blue LED will verify that the function is armed. (See wiring diagram on page five.) A third method to arm the maintenance setting is via a communication device. A Palm Pilot along with an IR Mint device can be employed to arm the setting. By initiating the ENABLE setting, the Maintenance Mode selection in the control screen of the Palm, Maintenance Mode is set. There is a confirmation screen that verifies the arming. A BIM (Breaker Interface Module) is another communcation method to arm the setting. When Maintenance Setting is enabled via device communications, this setting must be disabled by device communications. 4.0 Remote Indicator The Magnum circuit breaker will be wired with secondary contacts A9 and A12. Circuit breakers built after September 2005 have a normally open contact available for customer use. This contact can be used to indicate remotely that the Maintenance setting is armed. Refer to diagram on page three for a wiring of this remote (blue light) indicator. EATON CORPORATION Cutler-Hammer InformationSheets 70C1454H02 3

5.0 Choosing the Reduction Setting The Arc Flash Maintenance Switch is an eight position rotary switch that has five unique settings. Setting R5 is repeated four times. From the factory, the Magnum circuit breaker is shipped with the Digitrip unit set to the R5 setting and with its arming switch set to the 0/1 position. The 0/1 position means that it is locally OFF, but can be remotely turned ON. The blue LED, if illuminated, provides indication that the Maintenance Mode setting is armed per one of the three methods described in section 3.0. In general, the selection of one of the Reduction Settings (R5 through R1) should be determined and selected by a person who is experienced in power system analysis. This setting choice normally does not change unless there are future system modifications that could increase or decrease fault levels at the circuit breaker location. 6.0 Tripping and Testing The Maintenance Mode function will provide fast tripping even when the regular Instantaneous is set to OFF. The Instantaneous LED position is also used to indicate a trip initiated by the Maintenance Mode setting. The LCD display, if powered, will indicate this with four dashes. The Maintenance setting, external wiring (if any) and tripping functionality should be periodically verified by primary or secondary injection current testing. 4 EATON CORPORATION Cutler-Hammer Information Sheets 70C1454H02

EATON CORPORATION Cutler-Hammer InformationSheets 70C1454H02 5

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information recommendations, descriptions and safety notations in this document are based on Eaton s experience and judgment and may not cover all contingencies. If further information is required an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton Electrical Inc. selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON ELECTRICAL INC. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. IN NO EVENT WILL EATON ELECTRICAL INC. BE RESPONSIBLE TO THE PURCHASER OR USER IN CONTRACT, IN TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY OR OTHERWISE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGE OR LOSS WHATSOEVER, INCLUDING BUT NOT LIMITED TO DAMAGE TO OR LOSS OF USE OF EQUIPMENT, PLANT OR POWER SYSTEM, LOSS OF PROFITS OR REVENUES, OR CLAIMS AGAINST THE PURCHASER OR USER BY ITS CUSTOMERS RESULTING FROM THE USE OF THE PRODUCTS OR INFORMATION, RECOMMENDATIONS AND DESCRIPTIONS CONTAINED HEREIN. Cutler-Hammer is a federally registered trademark of Eaton Corporation. Digitrip is a trademark of Eaton Corporation. Eaton Electrical, Inc. 1000 Cherrington Parkway Moon Township, PA 15108-4312 United States Tel.: 1-800-525-2000 www.eatonelectrical.com 2006 Eaton Corporation All Rights Reserved Printed in USA Publication No. I.S.70C1454H02 May 2006 6 EATON CORPORATION Cutler-Hammer Information Sheets 70C1454H02