Obtain top-quality tissue samples with ease and efficiency

Similar documents
TEMNO. Soft Tissue Biopsy Devices OBTAIN TOP-QUALITY TISSUE SAMPLES WITH EASE AND EFFICIENCY ORIGINAL TEMNO TEMNO EVOLUTION

BD Syringes & Needles

BD Syringes & Needles

Advancing Cancer Diagnostics Improving Lives. Leica RM2235. The Manual Rotary Microtome For Outstanding Durability, Precision, and Comfort

Video Assisted and Thoracoscopic Major Pulmonary Procedures

Advancing Cancer Diagnostics Improving Lives. Leica RM2255. Rotary Microtome for High-Performance Motorized and Manual Sectioning

Product Catalog. Disposable Endoscopic Medical Devices

RapidPort EZ Access Port Kit DIRECTIONS FOR USE (DFU)

LOGICATH Central Venous Catheter. From The Name You Trust

ENT. Suite 2, 242 Beecroft Road Epping, NSW 2121 ph: (02) , fax: (02) DISTRIBUTED BY: Endotherapeutics

HI VISION Ascendus. A First Class ultrasound platform with uncompromised image quality.

APLIO JUST GOT EVEN BETTER INTRODUCING THE INNOVATION 2016 UPGRADE

UGEO G60 Performance in style

Bard Biopsy Systems PRODUCT LIST

By your side. Anytime. Anywhere.

LOGIQ. V2 Ultrasound. Part of LOGIQ Vision Series. Imagination at work LOGIQ is a trademark of General Electric Company.

Equine, Bovine, Camels

INSTRUMENTS CATALOGUE

Low Profile 3.5 Pelvic System. The comprehensive solution for pelvic fracture fixation.

INSPIRED BY YOUR PATIENTS.

INTERVENTIONAL PRODUCTS. (866)

T34 is the new standard in ambulatory syringe pumps offering a comprehensive range of features designed to maximise safe, economic and simple

EXPERIENCE THE POWER OF LIGHT

THE NEW STANDARD IN RADIAL COMPRESSION Not just a product, an experience. PreludeSYNC. Radial Compression Devices

AIRWAY INTELLIGENCE. Airway Management Supplies Smart solutions to establish and maintain reliable patient airways

MISCELLANEOUS ENDOSCOPY

Copyright by Si. ilca S.p.A All Right. ts Reserved

Focus on your needs. Ultrasound system HS60 SAMSUNG MEDISON CO., LTD. CT-HS60 V1.0-OB-FT EN

HEMOSTASIS Solutions for Effective Hemostatic Therapy.

Discontinued Products

I I I I I I I I I I I I I I I I I I I I I I I I. Needles. Advantages of the Merit Advance Needle

SHERIDAN ENDOTRACHEAL TUBES

The Topi-CLICK Micro Difference. Select one of 3. applicators

SINGLE-USE AND INSTRUMENT CARE PRODUCTS

Highlights Edition, Quarter 3. Laparoscopy

Compactly SAMSUNG powerful ULTRASOUND H60

TABLE OF CONTENTS BASIC INSTRUMENTATION ENDOSCOPES INSTRUMENT STORAGE FORCEPS

Redefining ultrasound access. Introducing the Viera portable breast ultrasound

Copyright by Silc. ca S.p.A All Rights Reserved

Cannulated Screw System. Surgical Technique

C-LAS LASER INNOVATION MADE IN GERMANY. ARTICULATED ARM / WAVEGUIDE IDEAL FOR AESTHETIC AND ENT SURGERY TABLE-TOP SYSTEM COMPACT

Leica EG1150. Convenient and comfortable tissue embedding center

needles, canulas, lancets and other medical products. The company is accredited with CE mark in compliance with

XLS+ Pipettes. Trust Your Data Extraordinary Tools for Exceptional Results

ilook 25 Next Generation in Portable Ultrasound Delivering the Personal Imaging Tool

Editorial EDITORIAL. Our devices are manufactured in France. See our latest news on

Laparoscopy. The cost-effective route to modern surgery. RIWKL-11011_Single_Port_Broschuere_GB_rz.indd 2

BF-UC180F. Endoscopic Ultrasonography Setting a New Standard in Mediastinal Diagnostics.

MEDIGENIC.

McCULLOCH. Micro-Discectomy Instruments The premium neurospine retractor system / / / / / / / / / /

Why use OUR IDEAL D3 NEEDLES?

Ordering Information. Low Profile 3.5 mm Pelvic System. The comprehensive solution for pelvic fracture fixation.

Safil Strong, Safe and Soft

DUODENOSCOPE ED-580XT

Beyond Performance and Value

ADVANCED BENDING SOLUTION WITH 3D CONTROL

SUTURE NEEDLES EYE TYPES NEEDLE SHAPES POINT TYPES

Mindray. Hand-carried Diagnostic Ultrasound System. Expanding the Envelope of Performance and Flexibility

Superior Imaging on the Go

digital reading micropipettes

ENT /2017-E. Headlight KS70. Highest quality medical illumination

Beyond Performance and Value

Contents. Illumination...GHI-110. Bipolar Forceps...GHI-210. Bipolar Electrodes...GHI-215. Scalpels...GHI-220. Scissors...

Compact Color and Doppler without Compromise. General Imaging

step into the future Ultrasound Diagnostic Imaging System

GamCath Catheters For Hemodialysis. Product Catalogue

Invivo Breast Coils: Best in Class Solid History of Coil Innovation

GE Healthcare. Vivid 7 Dimension 08 Cardiovascular ultrasound system

Superior Imaging on the Go

MEDICAL CONNECTIVITY SOLUTIONS THE THE RELIABLE EXPERT

How Do You Increase. Comfort. While. Improving. Patient. Outcomes? Balloon & Non-Balloon Buttons

SPINAL INSTRUMENTS EXTRAORDINARY QUALITY AND PERFORMANCE FOR LIFE

Family of Diagnostic and Therapeutic Catheters

V

Syringe Infusion Solutions

BD Alaris System User Manual Addendum

Leica FL800. Integrated Vascular Fluorescence. Living up to Life

Homework Assignment /645 Fall Instructions and Score Sheet (hand in with answers)

ALL-IN-ONE TMJ Arthroscope

Zebrascope user manual

Because Frozen Sections are Vitally Important

Speed. Copyright by Silca S.p.A All Rights Reserved. the products quality.

Ports Designed to Change. Your Point of View

PUREVUE VISUALIZATION SYSTEM. Differentiation That Matters, So You Can Visualize Success

Leica EM KMR3. Balanced-break Glass Knife Maker

Leading the New Standards

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

Stellaris PC System: Premium Performance Precise Control Integrated Versatile Intuitive

Fibular Distal Plate. Angularly stable screws The distal fibular plate is fixed using Ø 3.5 mm and Ø 3.5/2.7 mm angularly stable screws.

Your Olympus partner. EXXXXXX X /04 Reinhardt. Postbox , D Hamburg

MINOP InVent. Offering more for patients through less invasive techniques. Aesculap Neurosurgery

Ratec Shuttering System from Experienced Professionals Inserts & Insert Magnets

Complimentary Reference Material

Video Assisted Heart Valve Surgery

Time for a change: OPMI pico for ENT

14. Chromatography Syringes/Microlitre Syringes

Sapphire pipettes. Your Power for Liquid Handling.

MAMMOMAT 1000 / 3000 Nova. Accessories. Accessories (optional) Compression plate with low edge 18 cm x 24 cm #

A c c e s s o r i e s. r s & t o P Y R A. s C o n n e c T H E I V. s e d N e e d l e l e s. C l o. bionector Product Range

The Vision To Advance Your Quality Of Care

Transcription:

Obtain top-quality tissue samples with ease and efficiency BD soft tissue biopsy s Achieve Pink Achieve Evolution Adjustable coaxial (ACT)

BD offers a wide range of reliable soft tissue biopsy s for precise samples every time. Our proven brands, such as Achieve, and Tru-Cut, offer a complete selection with advanced features to obtain top-quality tissue samples with ease and efficiency. All of our devices are available in a wide range of gauge sizes and lengths to meet your procedural requirements. Achieve Evolution These BD devices can be used for soft tissue biopsy procedures, such as: Breast Kidney Liver Lung Prostate Thyroid The s in this catalog are not intended for use in bone. ACT Automated Achieve...1 Pink Achieve...1 Semiautomated Evolution...3 Adjustable coaxial (ACT)...4...5 Coaxial s Universal coaxial s...6 Fine aspiration (FNA) Chiba FNA...7 Franseen FNA...7 Manual Jamshidi Menghini...8 Tru-Cut...8

Achieve The lightweight, automated Achieve device offers spring-loaded action for fast, accurate penetration and the precise control and quality sampling capability you need. The Pink Achieve device is available in 14 and 12 G sizes for optimal control in breast biopsies. One-handed design for convenient manipulation of an ultrasound transducer Echogenic markings on the cannula and stylet to support precise ultrasound positioning Optional coaxial for multiple sampling 20 mm sample notch Achieve biopsy s only Needle size A206 x 6 cm A209 x 9 cm A2011 x 11 cm A2015 x 15 cm A2020 x 20 cm A186 x 6 cm A189 x 9 cm A1811 x 11 cm A1815 x 15 cm Achieve coaxial biopsy systems CA2011 x 11 cm 19 G x 6 cm CA2015 x 15 cm 19 G x 10 cm CA2020 x 20 cm 19 G x 15 cm CA1811 x 11 cm 17 G x 6 cm CA1815 x 15 cm 17 G x 10 cm A1820 x 20 cm CA1820 x 20 cm 17 G x 15 cm A1825 x 25 cm A166 16 G x 6 cm CA1611 16 G x 11 cm 15 G x 6 cm The Achieve offers three firing modes for procedural flexibility 16 G A169 A1611 A1615 A1620 16 G x 9 cm 16 G x 11 cm 16 G x 15 cm 16 G x 20 cm 16 G CA1615 16 G x 15 cm 15 G x 10 cm CA1620 16 G x 20 cm 15 G x 15 cm 1. Automatic mode Automatic mode releases the cannula and stylet in rapid sequence, and captures a tissue sample with one push of a button. Pre-biopsy (fully charged) Sample captured (Press button A.) A146 x 6 cm A149 x 9 cm A1411 x 11 cm A1415 x 15 cm A1420 x 20 cm CA1411 x 11 cm 13.5 G x 6 cm CA1415 x 15 cm 13.5 G x 10 cm CA1420 x 20 cm 13.5 G x 15 cm 2. Delay mode Delay mode allows the clinician to verify the position of the sample notch in the target area before activating the cutting cannula. 3. Zero-throw mode Zero-throw mode offers precision with no forward throw of the, reducing the threat of damage to deeper tissue. Pre-biopsy (fully charged) Needle position confirmation within lesion (Press button D.) Sample captured (Press button A.) Pink Achieve biopsy s only Needle size BA129 12 G x 9 cm 12 G BA1211 12 G x 11 cm BA1215 12 G x 15 cm BA149 x 9 cm BA1411 x 11 cm Pink Achieve coaxial biopsy systems 12 G BCA1211 12 G x 11 cm 10 G x 6 cm BCA1215 12 G x 15 cm 10 G x 10 cm BCA1411 x 11 cm 13.5 G x 6 cm Manual placement through lesion (uncharged) Cannula retracts exposing sample notch (charged once) Sample captured (Press button A.) 1 2

Evolution Evolution s offer many of the same features that made our original biopsy a leading seller, while setting the standard for procedural flexibility and performance. They are available with or without a coaxial. The four-bevel tip is significantly sharp for quick, easy penetration. The compact, lightweight design allows one-handed operation and can help reduce tissue shear. Two notch sizes 10 or 20 mm provide controlled, precise sampling for a variety of procedural situations. A short tip minimizes the risk of perforating surrounding organs and vessels. Tactile-enhanced plunger for ergonomic control Ergonomically-contoured body and soft, pliable finger grips provide increased comfort. ACT The ACT combines the quality and reliability of the brand with innovative technology. The device lets you manipulate the sample notch size from 9 to 19 mm for precise control with small lesions and peace of mind in vascular areas. It includes a coaxial. Compact, lightweight design passes through CT gantry with ease. One-handed operation allows convenient manipulation of the ultrasound transducer. Ability to reposition stylet prior to sample capture for greater confidence. Tissue settles in notch before firing for a larger core. Tactile-enhanced plunger for ergonomic control Smooth charging and advancement of stylet Evolution size with TT2011 x 11 cm CTT2011 19 G x 6 cm TT206 x 6 cm TT2015 x 15 cm CTT2015 19 G x 10 cm The spacer allows for precise placement while using the 10 mm option with coaxial. Centimeter depth marks ACT 22 G ACT2211 22 G x 11 cm x 6 cm ACT2215 22 G x 15 cm x 10 cm The adjustable coaxial bolt and corresponding measurement indicator allow accurate notch size and throw confirmation. TT2020 x 20 cm CTT2020 19 G x 15 cm TT1811 x 11 cm CTT1811 17 G x 6 cm TT186 x 6 cm TT1815 x 15 cm CTT1815 17 G x 10 cm TT1820 x 20 cm CTT1820 17 G x 15 cm 16 G TT1611 16 G x 11 cm CTT1611 15 G x 6 cm TT166 16 G x 6 cm TT1615 16 G x 15 cm CTT1615 15 G x 10 cm TT1620 16 G x 20 cm CTT1620 15 G x 15 cm The four-sided bevel results in a super-sharp tip for quick, easy insertion with less trauma to organs and surrounding tissue. Echogenic marks on the stylet and cannula provide visibility under ultrasound. ACT2011 x 11 cm 19 G x 6 cm ACT2015 x 15 cm 19 G x 10 cm ACT2020 x 20 cm 19 G x 15 cm ACT1811 x 11 cm 17 G x 6 cm ACT1815 x 15 cm 17 G x 10 cm Centimeter depth marks Echogenic marks on the stylet and cannula provide visibility under ultrasound. TT1411 x 11 cm CTT1411 13.5 G x 6 cm TT146 x 6 cm TT1415 x 15 cm CTT1415 13.5 G x 10 cm TT1420 x 20 cm CTT1420 13.5 G x 15 cm The four-sided bevel tip tracks straighter compared to standard bevel designs, eliminating unwanted distal drift or deflection. ACT1820 x 20 cm 17 G x 15 cm ACT1415 x 15 cm 13.5 G x 10 cm Coaxial Sharp bevel tip 3 4

The original device is easy to use, offering simplicity, reliability and precision you can count on. It features a 20 mm sample notch and a lightweight, compact design. Available with or without a coaxial. Tactile-enhanced plunger for ergonomic control Universal coaxial s Our thin-wall s provide a clear path that makes it easier to perform multiple biopsies at one site. Use them with any Achieve or core and with fine aspiration (FNA) s. Smooth charging and advancement of stylet Original with Coaxial s ending* T226 22 G x 6 cm T229 22 G x 9 cm 22 G T2215 22 G x 15 cm CT2215 x 10 cm Coaxial connector hub PP2010 x 10 cm 22 G x 15 cm 2215 PP2015 x 15 cm 22 G x 20 cm 2220 CT2220 x 15 cm T2011 x 11cm CT2011 19 G x 6 cm T206 x 6 cm T209 x 9 cm T2015 x 15cm CT2015 19 G x 10 cm T2020 x 20 cm CT2020 19 G x 15 cm T1811 x 11 cm CT1811 17 G x 6 cm T186 x 6 cm T189 x 9 cm T1815 x 15 cm CT1815 17 G x 10 cm T1820 x 20 cm CT1820 17 G x 15 cm Centimeter depth marks 19 G 17 G PP206 x 6 cm 22 G x 11 cm 2211 PP196 19 G x 6 cm x 11 cm 2011 PP1910 19 G x 10 cm x 15 cm 2015 PP1915 19 G x 15 cm x 20 cm 2020 PP176 17 G x 6 cm x 11 cm 1811 PP1710 17 G x 10 cm x 15 cm 1815 PP1715 17 G x 15 cm x 20 cm 1820 Coaxial s feature: The positive-locking skin stop controls forward migration. The trocar-point stylet penetrates tissue with ease for a smooth, straight insertion. The blunt-ended cannula allows multiple sampling from one percutaneous puncture with minimal damage to surrounding tissue. The centimeter markings and echogenic tip facilitate ultrasound-guided procedures. A clear luer lock hub provides visibility. 16 G T1611 16 G x 11 cm CT1611 15 G x 6 cm T166 16 G x 6 cm T169 16 G x 9 cm T1615 16 G x 15 cm CT1615 15 G x 10 cm Additional echogenic marks on the stylet and cannula provide visibility under ultrasound. 15 G PP156 15 G x 6 cm 16 G x 11 cm 1611 PP1510A 15 G x 10 cm 16 G x 15 cm 1615 PP1515A 15 G x 15 cm 16 G x 20 cm 1620 The is just one gauge size larger than its compatible core tissue biopsy (except a 22 G uses a, and a uses a 13.5 G ). T1620 16 G x 20 cm CT1620 15 G x 15 cm T1411 x 11 cm CT1411 13.5 G x 6 cm T146 x 6 cm T149 x 9 cm T1415 x 15 cm CT1415 13.5 G x 10 cm T1420 x 20 cm CT1420 13.5 G x 15 cm Sharp bevel tip For single use only. Ten devices per case. PP1356 13.5 G x 6 cm x 11 cm 1411 PP13510 13.5 G x 10 cm x 15 cm 1415 * Order biopsy with ending as specified. For example, PP1910 fits Achieve A2015, standard T2015 and Chiba FNA CHI2015. A 10 G coaxial is only available with the 12 G Pink Achieve and is not sold separately. Features include a wing grip, a trocar stylet, a bevel cannula, centimeter depth marks and a luer lock hub. 5 6

FNA s Designed for aspiration of soft tissue masses, FNA s are available with a Chiba or Franseen tip for optimum versatility. FNA s are also available in sets with the universal coaxial. The coaxial facilitates multiple sampling and is compatible with standard s for histology backup. Coaxial sets include two aspiration s (either Chiba or Franseen) and one universal coaxial. Coaxial sets with Chiba Needle 22 G CCH2210 22 G x 10 cm x 5 cm CCH2215 22 G x 15 cm x 10 cm CCH2220 22 G x 20 cm x 15 cm CCH2015 x 15 cm 19 G x 10 cm CCH2020 x 20 cm 19 G x 15 cm Coaxial sets with Franseen CFR2210 22 G x 10 cm x 5 cm Chiba Franseen Jamshidi Menghini The Jamshidi Menghini soft tissue biopsy for histological and cytological biopsy samples is designed to achieve maximum results for your liver biopsies. The product consists of a 10mL syringe attached to the biopsy. Available in a wide range of sizes. Jamshidi Menghini biopsy s only 17 G 16 G 15 G For single use only. SN7017X SN1017X SN7016X SN1016X SN7015X SN1015X 17 G x 70 mm 17 G x 100 mm 16 G x 70 mm 16 G x 100 mm 15 G x 70 mm 15 G x 100 mm 22 G CFR2215 22 G x 15 cm x 10 cm CFR2220 22 G x 20 cm x 15 cm CFR2015 x 15 cm 19 G x 10 cm CFR2020 x 20 cm 19 G x 15 cm Chiba s only Franseen s only Needle Size Size CHI226 22 G x 6 cm CHI229 22 G x 9 cm 22 G CHI2210 22 G x 10 cm FRA2210 22 G x 10 cm CHI2215 22 G x 15 cm FRA2215 22 G x 15 cm CHI2220 22 G x 20 cm FRA2220 22 G x 20 cm CHI205 x 5 cm CHI2010 x 10 cm FRA2010 x 10 cm CHI2015 x 15 cm FRA2015 x 15 cm CHI2020 x 20 cm FRA2020 x 20 cm CHI1815 x 15 cm FRA1815 x 15 cm CHI1820 x 20 cm FRA1820 x 20 cm For single use only. Ten devices per case. Features include: Chiba bevel tip to obtain an aspirate for cytology Franseen crown-point tip for samples in fibrous lesions Centimeter depth markings that aid in accurate placement Clear luer lock hub for good visibility during aspirate procedures Positive-locking skin stop for controlling forward migration Echogenic tip to enhance ultrasound visualization Tru-Cut biopsy s The Tru-Cut biopsy is designed for manual capture of high-quality tissue samples with minimal trauma to the patient. Features include: 20 mm specimen notch Scalpel-sharp, surgical-steel cutting edge that retrieves cleanly cut, high-quality specimens Removable stylet for multiple sampling capability Thin-wall to yield larger core Centimeter depth markings to assist in placement 2N2711X 2N2712X 2N2713X 2N2700X 2N2702X 2N2704X For single use only. Size x 7.6 cm x 11.4 cm x 15.2 cm x 7.6 cm x 11.4 cm x 15.2 cm 7 8

Soft tissue s quick reference Gauge Length (cm) prefix Sample notch (mm) Throw (mm) Coaxial Echogenic markings Tip shape Stylet Cannula Stylet Cannula 22 20 19 18 17 16 15 14 12 5 6 9 10 11 15 20 25 Achieve A 20 25 Compatible Yes Yes Bevel Bevel Achieve Automated Achieve CA 20 25 Included Yes Yes Bevel Bevel Pink Achieve BA 20 25 Compatible Yes Yes Bevel Bevel Automated Achieve Pink Achieve Pink Achieve BCA 20 25 Included Yes Yes Bevel Bevel Pink Achieve Evolution TT 10 or 20 12 or 21 Compatible Yes Yes Four-sided bevel Bevel Evolution Semiautomated Evolution CTT 10 or 20 12 or 21 Included Yes Yes Four-sided bevel ACT device ACT 9 19 14 24 Included Yes Yes Bevel Bevel T 20 22 Compatible Yes Yes Bevel Bevel Bevel Semiautomated Evolution ACT device coaxial CT 20 22 Included Yes Yes Bevel Bevel coaxial Universal coaxial PP N/A N/A N/A No Yes Trocar Blunt Universal coaxial 13.5 Not all lengths are available for every gauge size. Please check the individual ordering information charts in this brochure for details before ordering. 9 10

Soft tissue s quick reference Gauge Length (cm) prefix Sample notch (mm) Throw (mm) Coaxial Echogenic markings Tip shape Stylet Cannula Stylet Cannula 22 20 19 18 17 16 15 14 12 5 6 9 10 11 15 20 25 Chiba FNA CHI N/A N/A Compatible No Yes Bevel Bevel Chiba FNA FNA s Chiba coaxial set CCH N/A N/A Included No Yes Bevel Bevel Franseen FNA FRA N/A N/A Compatible No Yes Trocar Crown FNA s Chiba coaxial set Franseen FNA Franseen coaxial set CFR N/A N/A Included No Yes Trocar Crown Franseen coaxial set Manual Jamshidi Menghini SN N/A N/A No N/A No N/A Bevel Tru-Cut 2N2 20 23 No No No Bevel Bevel Manual Jamshidi Menghini Tru-Cut 70 mm 7.6 cm 100 mm 11.4 cm 15.2 cm Not all lengths are available for every gauge size. Please check the individual ordering information charts in this brochure for details before ordering. 11 12

To place an order or for more information, please contact your interventional specialties sales representative or visit bd.com/softtissue Refer to the complete instructions for use accompanying the devices, or follow the instructions on the product labeling. Medical devices class sterile IIa, according to Medical devices Council Directive 93/42/EEC, CE marked by TÜV SÜD Product Service GmbH (0123). CareFusion 75 North Fairway Drive Vernon Hills, IL 60061 USA CareFusion France 309 S.A.S. 8 bis rue de la Renaissance 44110 Châteaubriant France European headquarters: BD, Terre-Bonne-Park - A4 Route de Crassier 17 1262 Eysins, Switzerland Tel: +41(0) 21 556 30 00 bd.com Filter Straw is a trademark of B. Braun Medical Inc. 2017 BD. BD, formally known as CareFusion and the BD Logo and all other trademarks are property of Becton, Dickinson and Company. CF03163, issue 1 Mar 2017 (IS4426 (0916/1000))