Precision humidity/temperature sensing/control

Similar documents
Precision humidity/temperature control/sensing

A C C U R A C Y B Y D E S I G N

Precision temperature control/sensing

CDD ModBus Carbon Dioxide Detector

Installation Guide. Section 1 - Room... pg 03. Section 2 - Duct... pg 23. I-CDD3_Modbus Installation. Modbus Gas Transmitters I-CDD3 Series

CDD4 Series Room CO2 Transmitter Installation Instructions

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

CDD Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter

Carbon Monoxide Transmitter

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

Measure & Control Temperature & CO2 levels with analog & digital I/O

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

BACnet. b3810 Series Local Controllers

Carbon Monoxide Sensor - ModBus

FX06 Field Controller

H7625A, H7635A Humidity/Temperature Sensors

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

FX Input/Output (I/O) Modules XM07 and XM14

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

Allure EC-Smart-Comfort Series

TPE 1464 Series Pressure Transducer

AIR QUALITY/ GAS DETECTION

SE7600E Series Application Guide

Allure EC-Smart-Comfort Series

MOD-RI Room Interface Modules with Modbus

Humidity transmitter for critical climate applications

HLS34 Modbus FCU/VAV Controllers installation instructions

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

clarity 3 Programmable Controller

Andover ContinuumTM Infinet II

Multi-Point Gas Detection and Control System

DTM Distributed Transmitter Monitor

Zone Pressure Touch (ZPT) Sensor - Standard Range

LLR-MOD Modbus Light Level and Occupancy Sensor

Multi-Point Gas Detection and Control System

RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units

FXVMA Variable Air Volume (VAV) Box Controller

Zone Pressure Touch Sensor - Standard Range

BA/BS4S Temperature Sensor Installation & Operating Instructions

RTD-NET Installation Instructions

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

THERMOSTATS & CONTROLLERS

Millennium Simplicity Elite Parameter Points and Quirks

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

InBin-P Pressure switches from 5 Pa Pa

Field selectable application type and room module series, via dip-switches on controller

Andover ContinuumTM. b3850 Series Terminal Controllers

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Family of Water Cut Analyzers

SE7600E Series Application Guide

BACnet Product Overview

Carbon Monoxide (CO) Gas Detection and Control System

CAEL-DP Series Dew Point Transmitter for Industrial Control

SDC-20G/32G Graphics Series Distributed Controller Reference Manual

Differential Liquid/Gas Pressure Transmitter

RTD-W Installation Instructions

Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Product Manual SZ2144

Product Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

RS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

MANUAL INSTALLATION. Multi-Variable Monitor. MVM Series. Issue Date: 02/07/ Price Industries Limited. All rights reserved.

Multi-Point Gas Detection and Control System

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

TC-9102 Terminal Controller

HARDWARE GUIDE. VAV Zone Controller C1000 Series. Specifications and Operational Guide

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

FUME HOOD CONTROLLER (FHC)

Product Manual SZ2141

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

RXTP ROOM TEMPERATURE

DP DP2500 DP0250

CTR21, CTR22, CTR23, and CTR24 Wall Modules

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Andover ContinuumTM Infinet II

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

CDR Room CO 2 and Temperature Sensor with Modbus

RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter

TOXALERT MODEL AIR 2000

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

The industrial humidity transmitter

Fast Route to Reliable Energy Savings ZIP Economizer

Tstat8. Bacnet Thermostat

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Transcription:

HUMIDITY/TEMPERATURE SENSOR BACnet or Modbus Communication NT Series Precision humidity/temperature sensing/control FEATURES: BACnet or Modbus communication Temperature and RH monitoring Room, Duct or Outside LCD display (Room only) Several optional features available Peace of mind through reliable humidity/temperature monitoring GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM

DESCRIPTION (ROOM): The NTRC Series Room Network Sensor features embedded BACnet and Modbus communication and is available in several configurations for the most efficient monitoring and control solution. The basic unit accurately measures room temperature. Optional features include RH measurement, up/down setpoint control, local override function, control relay output, fan speed switch and a digital input. The device connects to an RS-485 MS/TP network to offer a single-point solution for control of indoor air comfort. Features include a back-lit LCD and user menu for easy configuration, field-proven sensors and user input controls to add optional local setpoint and override functions at the same network point. SPECIFICATIONS (ROOM): General Specifications: Power Supply...20-28 Vac/dc (non-isolated half-wave rectified) Consumption...35 ma max @ 24 Vdc Protection Circuitry...Reverse voltage and over voltage protected Operation Conditions...0-50 C (32-122 F), 0-95% RH, non-condensing Wiring Connections...Screw terminal block (14 to 22 AWG) External Dimensions...84 W x 119 H x 29 D mm (3.3 x 4.7 x 1.15 ) Enclosure...White ABS, IP30 (NEMA 1) Communications Interface: Hardware...2-wire RS-485 Software...Native BACnet or Modbus MS/TP protocol, menu selectable Baud Rate...Locally set from 300 to 76800 Network Address Range...Locally set to 0-127 for BACnet or 1-255 for Modbus (Factory default is 3) (63 devices max on one daisy chain) LCD Display: Resolution...0.5 or 1 C/F (selectable), 1% RH Size...38.1 W x 16.5 H mm (1.5 x 0.65 ), 3 digit Backlight...Auto-dimming, enable/disable via jumper Displayed Values... Temperature Only, RH Only or Alternating Temperature/RH (RH requires optional RH Signal) Temperature: Sensing Element...10K thermistor, ±0.2 C (±0.4 F) Range...0-35 C (32-95 F) Optional RH Signal: Sensing Element...Thermoset polymer based capacitive Accuracy...± 2% RH Range...0-100% RH, non-condensing Resolution...1% RH Hysteresis...± 3% RH Response Time...15 seconds typical Stability...± 1.2% RH typical @ 50% RH in 5 years Optional Override Switch: User Interface...Front panel push-button available via BACnet or ModBus Override Status...Via BACnet or ModBus. OCC segment lights on LCD Optional Setpoint Control: User Interface...Front panel, up/down push-buttons available via BACnet or Modbus Setpoint Mode...Temperature ( C/ F) or RH, menu selectable (Factory default is Temperature & C) Adjustable Setpoint Range...10-30 C, 50-86 F or 10-80% RH, menu selectable (Factory default is 18 to 24 C) Minimum Span... 4 C/F or 10% RH Temperature Setpoint Resolution... 0.5 or 1, menu selectable (Factory default is 1 ) Optional Fanspeed Switch: User Interface...Side panel, 5 position switch available via BACnet or Modbus Indication... Off, Auto, Low, Mid, High switch position Optional Relay Output: Contact Ratings...Form A contact (N.O.), 2 Amps @ 140 Vac, 2 Amps @ 30 Vdc Relay Activation...Via BACnet or Modbus Optional Digital Input: Input Type...Dry-contact only (relay contact), short to COMMON to activate

PRODUCT ORDERING INFORMATION (ROOM): MODEL Description NTRC Network Room Sensor N L LCD Display Concealed Viewable T RH Configurations Temperature Only Temperature & Humidity Setpoint Adjustment - No Setpoint Adjustment (Leave blank) P Setpoint Adjustment Momentary Override - No Override (Leave blank) S Override Switch Fan Speed Switch - No Fan Speed Switch (Leave blank) F 5 Position Fan Speed Switch Relay Output - No Relay (Leave blank) R Relay Digital Input - No Digital Input (Leave blank) D Digital Input NTRC L RH P S - - Greystone Energy Systems Inc. reserves the right to make design modifications without prior notice. PCB/WIRING INFORMATION Terminal POWER COMMON D INPUT B + A - SHIELD RELAY Function From +20-28 Vac/dc of controller or power supply To GND or COMMON of controller To dry contact output of device To + of communications bus To - of communications bus To communications bus shield To digital input of controller Some models do not have all features

DESCRIPTION (DUCT/OUTSIDE): The NT Series RH/Temperature Network Sensors use a highly accurate and reliable thermoset polymer based capacitance humidity sensor and curve-matched NTC thermistor temperature sensor together with embedded BACnet or Modbus communication to provide the most efficient monitoring and control solution. The NT Series sensors connect to an RS-485 MS/TP network to offer a single-point solution for control of air comfort. The NT Series sensors are available in both duct and outside mounting configurations. SPECIFICATIONS (DUCT/OUTSIDE): General Specifications: Power Supply...BACnet : 24 Vac/dc ± 10% (non-isolated half-wave rectified) Modbus: 15-30 Vac/dc (non-isolated half-wave rectified) Consumption...BACnet : 25 ma max @ 24Vdc Modbus: 10 ma max @ 24 Vdc Protection Circuitry...Reverse voltage and over voltage protected Operation Conditions...-40-50 C (-40-122 F), 0-95% RH, non-condensing Wiring Connections...Screw terminal block (14 to 22 AWG) Enclosure...Duct: Grey ABS, UL94-5VB - IP61 (NEMA 2) Outside: Gray ABS, UL94-5VB - IP65 (NEMA 4X) Enclosure Dimensions...Duct: 114 W x 84 H x 53 D mm (4.5 x 3.3 x 2.1 ) Outside: 145 W x 100 H x 64 D mm (5.7 x 3.95 x 2.5 ) Probe...Duct: 230 mm (9 ) long x 12.7 mm (0.5 ) diameter Stainless steel with porous filter Outside: 20 mm (0.8 ) long x 28 mm (1.1 ) diameter PVC hub with mesh filter Relative Humidty: Sensing Element...Thermoset polymer based capacitive Accuracy...± 2% RH Range...0-100% RH Resolution...0.1% RH Hysteresis...± 1.5% RH Response Time...15 seconds typical Stability...± 1.2% RH typical @ 50% RH in 5 years Temperature: Sensing Element...20KΩ NTC thermistor Accuracy...±0.2 C (±0.4 F) curve matched Range...-40-50 C (-40-122 F) Resolution...0.1 C/ F BACnet Communications Interface: Hardware...2-wire RS-485 Software...Native BACnet MS/TP protocol Baud Rate...9600, 19200, 38400 or 76800 - Auto-detect Network Address Range...Locally set to 0-127 Modbus Communications Interface: Hardware...2-wire RS-485 Software...Native Modbus MS/TP protocol (RTU) Baud Rate...4800, 9600, 19200, 38400 or 76800 - Auto-detect Network Address Range...Locally set to 1-255 Parity...None Stop Bits...1 CRC...A001 (CRC-16 reverse)

PRODUCT ORDERING INFORMATION: MODEL Description NT Network Sensor DA OA Type Duct Outside BAC MOD Communications Output BACnet Modbus NT DA BAC Greystone Energy Systems Inc. reserves the right to make design modifications without prior notice. PCB/WIRING INFORMATION (DUCT/OUTSIDE) BACnet Modbus PWR PWR COM COM SHLD B+ Terminal Function SHLD B+ A- EOL BUS ADDRESS 1 2 4 8 16 32 64 0001342 PWR COM SHLD B + A - 24 Vac/dc of controller or power supply To GND or COMMON of controller To communications bus shield To + of communications bus To - of communications bus A- EOL BUS ADDRESS 1 2 4 8 16 32 64 128 0001338 BACnet COMMUNICATION BACnet is a data communication protocol for building automation and control networks. The sensor communicates on a standard 2-wire RS-485 MS/TP network designed to run at speeds from 9600 to 76800 baud over twisted pair wiring. BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test products for compliance with ASHRAE standards. Compliance of BACnet listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet International (BI). BTL is a registered trademark of BI. MODBUS COMMUNICATION Modbus is a network protocol for industrial manufacturing environments. The sensor communicates on a standard Modbus network using the RTU (Remote Terminal Unit) transmission mode. The hardware interface is RS-485.

DIMENSIONS 84 mm 3.3 29 mm 1.15 58 mm 2.3 119 mm 4.7 82.6 mm 3.25 114 mm 4.5 53 mm 2.1 2X Ø 0.850 304 Series S/S Probe 84 mm 3.3 60 micron HDPE filter 12.70 mm 0.50 Mounting Holes (X2) Ø 0.200 228.60 mm 9 114 mm 4.5 114 mm 4.5 100 mm 3.95 Ø 0.850 28 mm 1.1 ENERGY SYSTEMS INC Greystone Energy Systems Inc. 150 English Drive, Moncton, New Brunswick, Canada E1E 4G7 (506) 853-3057 Fax: (506) 853-6014 North America: 1-800-561-5611 e-mail: mail@greystoneenergy.com web site: www.greystoneenergy.com Mounting Holes (X4) Ø 0.200 20 mm 0.8 Greystone Energy Systems Inc. is one of North America s largest ISO registered manufacturers of HVAC/R sensors and transmitters for Building Automation Management Systems. We have conscientiously established a worldwide reputation as an industry leader by maintaining leadingedge design technology, prompt technical support, and a commitment to on-time deliveries. We take pride in our Quality Management System which is ISO 9001 certified, assuring our customers of consistent product reliability. GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM PRINTED IN CANADA Copyright Greystone Energy Systems Inc. All Rights Reserved PB-NT-02-02 04/17