UC-2000 Installation Manual Unicorn Computers Technology Limited

Similar documents
Quick Start Installation Guide

BioPointe Reader Installation Guide

Quick Start Installation Guide

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Suprex RS-485 SPX-7500 Wired Reader-Extender

PS-4100 POWER SUPPLY MANUAL

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

P522 Signal Processor

NS1 Connection Unit Guide

N-1000-II. Installation & Programming Manual. Version rev. 2.0

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

EL-ST100 KEYPAD CONTROLLER

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

DOLXFD1000B. Waterproof Access Control/Reader

IEI emerge MicroNode Install and Setup Guide. Contents

MR52 READER INTERFACE

TAC I/NETTM 1284, 1280, Security Control Unit

Installing the DX LCD Display

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

6222 Two Door Module Technical Operations Manual

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

PXL-250 Tiger Controller

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

SmartLock Controller INSTALLATION MANUAL

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

istar Pro Installation Guide

Digital Keypad Introduction

Quick Start Installation Guide

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

SPX-7400_SPX-7410_MAN_161028

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Two Door Controller GEN-045

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Installation Manual

EA500. Installation Instructions Transponder

Expandable Power Systems

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

Operation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller

SmartLock Pro INSTALLATION MANUAL

8000 Series: Installation Supplement R2-1-12

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

MicroTech Series-100 Application Specific Controller

INNOMETRIKS INC. Rhino Quick Start Guide

ENGINEERING SPECIFICATIONS SENSAPHONE 2000

T- P1000 HandSwipe guide. Table of Contents. Initial setting 3. Programming the HandSwipe 4. Service Menu (1) 5. Setup Menu (2) 6

2012 IDenticard Systems, Inc.

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

DESIGN GUIDE FOR INFINITY SYSTEMS

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

Stand-alone Proximity Access Control

Lab 5: Access Control Training Station

721EX Access Controller Installation

TruPortal Dual Door Interface Module Quick Reference

SINGLE READER EXPANSION MODULE

Single Door Standalone Access Control User Manual

Installation Instructions (KF-2000)

PRT-RDS2 Standard 2 Reader Expander

System Galaxy Hardware Manual

Access Terminal IF-800

High Level Lift Protocol Controller Model TS0868

MR50 READER INTERFACE

Waterproof. Keypad/Reader/Controller

Click Save to return to the main Setup screen.

PRO3200 Professional Modular Access Control Hardware

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

GT- IRDM-9603 Product description Rev. 2 17/06/2014

LPG STM 94442A User s Manual

AC-225x-B Series. Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual. Models:

GV-AS Controller. Installation Guide

Access Easy Control System. Reference Guide

VOICE and/or DATA CELLULAR SYSTEM

Installation & User Manual

PRO2200 Professional Modular Access Control Hardware

Supervised Input Module Installation Manual

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SEC-H-201 Security Controller

CM-110SK Standalone Keypad Installation Instructions

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN

4.7 Expansion Module MAC00-FS1/FS4

RC1170-RC232 USER MANUAL

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

WAC-IPMG200 IP Based Access Control System

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Installation & User Manual V2.08

1.0 Wiring and Layout Diagrams

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

REX F-0-9 Standalone or Access Controller

Cardax FT Controller 3000

Transcription:

UC2000 Installation Manual Copyright 2003. All rights reserved.

Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller Layout 5 UC100 Layout 6 Cable Connection for UC100 to Computer and to Modem 7 Direct Cable Connection for UC2000 to Computer and to Modem 7 20mA Loop Communication Wiring for Single Panel 8 20mA Loop Communication Wiring for more than one Panel 9 Card Reader Wiring 10 Door 1 Wiring (One Panel for Two Doors) 11 Door 2 Wiring (One Panel for Two Doors) 12 IN / OUT Reader for Single Door Wiring (One Panel for One Door) 13 Important Notice 14 1

Specifications Power Requirements: The UC2000 Controller requires an 11.4Vac 12.6Vac 700mA minimum power supply. Sealed Lead Battery Requirements: The UC2000 Controller requires a 12Vdc 4 7 AH Sealed Lead Battery to provide up to 8 24 hours of full operational backup (depending on the load and the battery). Memory Backup: An internal rechargeable gold capacitor can retain the controller memory for up to 5 days upon loss of both primary and backup battery power. Output Power: Unregulated 12Vdc (10 to 16 volts) 200mA maximum for 12Vdc Card Readers. Regulated 5Vdc (4.75 to 5.25 volts) 100mA maximum for 5Vdc Card Readers. Fuses: 2 amp, 20 x 5mm, fast blow. Input Points: 5 nonsupervised input points (named I1, I2, I3, I4 and I12) are provided. I1 and I2 are for Magnetic Contacts (Door Status Sensors) of Door 1 and Door 2 respectively. I3 and I4 are for Exit Buttons of Door 1 and Door 2 respectively. I12 is wired to the enclosure tamper. Output Points: 2 DPDT relay outputs (named O1 and O2) rated at 24Vdc 1A are provided for door lock control of Door 1 and Door 2 respectively. Reader Interfaces: 2 Wiegand Card Reader Interfaces are provided for the Card Readers of Door 1 and Door 2. Operating Temperature: 35 F to110 F (2 C to 43 C). Operating Relative Humidity: 0 to 90% noncondensing. Dimensions: 33cm x 28cm x 7.6cm ( H x W x D) with lock and key. Enclosure tamper switch is provided. Weight: 6 pounds (2.7 kg) (Sealed Lead Battery is not included.). 2

Enclosure for the UC2000 Controller 12Vac SW1 SW2 3

Unicorn Access Control System Configuration Up to 600m between UC100 and UC2000 or between UC2000 and UC2000 Door Lock UC2000 Magnetic Contact Exit Button UCSOFT Up to 150m between UC100 UC2000 and Reader RS232 Wiegand Compatible Card Reader Up to 8 com ports can be used 20mA Loop (Up to 63 UC2000 Controllers per loop) UC2000 RS232 UC100 Modem Modem Other remote loop Modem UC2000 8bit Wiegand Keypad Reader UC2000 4

UC2000 Controller Layout Reader 2: Green LED (Brown) O14 Reader 2: Data 1 (White) Reader 2: Data 0 (Green) 5V Output (100mA max.) Common Unregulated 12V Output (200mA max.) Reader 1: Data 0 (Green) Reader 1: Data 1 (White) Reader 1: Green LED (Brown) O13 20mA Loop: T (Green) 20mA Loop: T (White) 20mA Loop: R (Black) 20mA Loop: R (Red) CN2 CN1 1 2 3 4 5 6 7 8 CN1 1 2 3 4 5 6 7 8 9 10 11 12 13 COM O1A NC O1A NO O1A NO O1B NC O1B COM O1B COM O2A NC O2A NO O2A NO O2B NC O2B COM O2B 1 1 1 2 3 4 5 6 7 8 SW1 ON 1 & 2: Baud Rate J5 Baud Rate 1 2 1200 OFF OFF 1 2 3 2400 OFF ON 4800 ON ON 12: 20mA Loop 9600 ON OFF 23: RS232 3 to 8: Panel Address Address 3 4 5 6 7 8 1 ON ON ON ON ON OFF 2 ON ON ON ON OFF ON 3 ON ON ON ON OFF OFF 63 OFF OFF OFF OFF OFF OFF SW2 CPU Reset CN2 1 2 3 4 J2 12: Normal 23: Clear all memory 3 2 1 12Vac 700mA AC 2 AC 1 12V 47AH Bettery Battery RS232: Pin5 Common RS232: Pin3 Tx RS232: Pin2 Rx I1 (Door 1 Magnetic contact) Common I2 (Door 2 Magnetic contact) I3 (Door 1 Exit Button) Common I4 (Door 2 Exit Button) I12 (Tamper Button) Common 12 11 10 9 8 7 6 5 4 3 2 1 K1 K2 5

UC100 Layout T (Black) T (Red) R (Green) R (White) 9Vac 300mA 1A To Modem (for Dialup Remote Site) To Computer (for Local Site) RS232: Pin5 Common RS232: Pin3 Tx RS232: Pin2 Rx RS232: Pin7 Common RS232: Pin3 Tx RS232: Pin2 Rx 6

Cable Connection for UC100 to Computer and to Modem A. Local Site ( Computer to UC100 ) 9Pin Female Socket ( connected to Computer COM Port ) Pin2 Rx Pin3 Tx Pin5 Common B. Dialup Remote Site ( UC100 to Modem ) 9Pin Female Socket ( connected to UC100 ) Pin2 Rx Pin3 Tx Pin5 Common 25Pin Male Socket ( connected to UC100 ) Pin2 Rx Pin3 Tx Pin7 Common 25Pin Male Socket ( connected to Modem ) Pin2 Rx Pin3 Tx Pin7 Common Direct Cable Connection for UC2000 to Computer and to Modem without UC100 C. Local Site ( Computer to UC2000 ) for Single Panel and Distance less than 50 feet only 9Pin Female Socket ( connected to Computer COM Port ) Pin2 Rx 9Pin Female Socket ( connected to UC2000 ) Pin2 Rx Pin3 Tx Pin5 Common Pin3 Tx Pin5 Common D. Dialup Remote Site ( UC2000 to Modem ) for Single Panel and Distance less than 50 feet only 9Pin Female Socket ( connected to UC2000 ) Pin2 Rx 25Pin Male Socket ( connected to Modem ) Pin2 Rx Cable Requirements: 3 conductors 1822 AWG Pin3 Tx Pin5 Common Max. Distance: 50 feet between UC100 and Computer or between UC100 and Modem 50 feet between UC2000 and Computer or between UC2000 and Modem without UC100 Pin3 Tx Tips: Check SW1 and J2 of each Panel Pin7 Common 1. Default baud Rate is 4800bps for Local Site (Pin 1 & 2 of SW1 is at ON ON position); change to 9600bps for dialup Remote Site (Pin 1 & 2 of SW1 is at ON OFF position respectively). 2. Push Reset Button SW2 after changed the baud Rate or the Address. 3. The J5 of Panels must be at 12 position for 20mA Loop Communication with UC100 or at 23 position for Direct Cable Connection without UC100. 7

20mA Loop Communication Wiring for Single Panel Data Flow Direction 1 13 T (Black) T (Red) R (Green) R (White) SW1 1 T (Black) T (Red) R (Green) R (White) 1 2 3 J5 8 SW2 Cable Requirements: Shielded Twisted pair 4 conductors (2 twisted pairs), one pair for transmission and the other for reception 1822 AWG Max. Distance: 2000 feet between UC100 and UC2000 Other Requirement: Single end grounding for every Cable Shield Tips: Check SW1 and J2 of each Panel 1. Default baud Rate is 4800bps for Local Site (Pin 1 & 2 of SW1 is at ON ON position); change to 9600bps for dialup Remote Site (Pin 1 & 2 of SW1 is at ON OFF position respectively). 2. Push Reset Button SW2 after changed the baud Rate or the Address. 3. The J5 of Panels must be at 12 position for 20mA Loop Communication. 8

20mA Loop Communication Wiring for more than one Panel Data Flow Direction 1 13 T (Black) T (Red) R (Green) R (White) SW1 1 T (Black) T (Red) R (Green) R (White) 1 2 3 J5 8 SW2 Cable Requirements: Shielded Twisted pair 4 conductors (2 twisted pairs), one pair for transmission and the other for reception 1822 AWG Max. Distance: 2000 feet between UC100 and UC2000 2000 feet between UC2000 and UC2000 Other Requirement: Single end grounding for every Cable Shield 1 T (Black) T (Red) R (Green) R (White) 13 SW1 1 1 2 3 J5 8 SW2 Tips: Check SW1 and J2 of each Panel 1. The baud Rate of Panels in the same loop must be the same (default is 4800bps for Local Site, Pin 1 & 2 of SW1 is at ON ON position; change to 9600bps for dialup Remote Site, Pin 1 & 2 of SW1 is at ON OFF position respectively). 2. The Address of Panels (Pin 3 to 8 of SW1) in the same loop must be different (from 1 to 63). 3. Push Reset Button SW2 after changed the baud Rate or the Address. 4. The J5 of Panels must be at 12 position for 20mA Loop Communication. 9

Card Reader Wiring Wiegand Card Reader Cable Requirements: Shielded 5 or 6 conductors 1822 AWG Max. Distance: 500 feet between Reader and UC2000 Other Requirement: Single end grounding for every Cable Shield 1 2 3 4 5 6 7 8 9 Reader 2: Green LED (Brown) Reader 2: Data 1 (White) Reader 2: Data 0 (Green) 5V Output (100mA max.) Common Unregulated 12V Output (200mA max.) Reader 1: Data 0 (Green) Reader 1: Data 1 (White) Reader 1: Green LED (Brown) SW2 Tips: 1. Check the required input voltage of the Card Reader if it is 5V or 12V before connecting to UC2000 Panel. 2. At least 8 16 inches distance between Card Readers to prevent the interference between each other. 3. The UC2000 Panel supports 26, 32, 34 or 36bit Wiegand Card Format. 4. The UC2000 Panel supports 8bit Wiegand Keypad Format plus 26, 32, 34 or 36bit Wiegand Card Format for the KeypadCard Reader to provide "Pin and Card" function. 10

Door 1 Wiring (One Panel for Two Doors) Cable Requirements: Shielded Twisted pair 2 conductors 1822 AWG Max. Distance: 500 feet between Door Lock and UC2000 500 feet between Exit Button and UC2000 500 feet between Magnetic Contact and UC2000 Power Source for Door Lock 12Vdc or 24Vdc Magnetic Contact ( Door Status Sensor ) 1N4007 Door Lock Other Requirement: Single end grounding for every Cable Sheld Entry Reader Exit Button 1 2 4 5 3 1 Tips: 1. A diode 1N4007 MUST be installed across every electrical switching device (Door Lock) run through a relay contact on the UC2000 Panel. The diode protects the UC2000 Panel from the power generated by the collapsing magnetic field of the electrical load device. 2. DON'T power door locks with the 12V output of the UC2000 Panel or with the same power supply used for the UC2000 Panel. 11

Door 2 Wiring (One Panel for Two Doors) Cable Requirements: Shielded Twisted pair 2 conductors 1822 AWG Max. Distance: 500 feet between Door Lock and UC2000 500 feet between Exit Button and UC2000 500 feet between Magnetic Contact and UC2000 Power Source for Door Lock 12Vdc or 24Vdc Magnetic Contact ( Door Status Sensor ) 1N4007 Door Lock Other Requirement: Single end grounding for every Cable Shield Entry Reader Exit Button 2 3 5 6 9 7 Tips: 1. A diode 1N4007 MUST be installed across every electrical switching device (Door Lock) run through a relay contact on the UC2000 Panel. The diode protects the UC2000 Panel from the power generated by the collapsing magnetic field of the electrical load device. 2. DON'T power door locks with the 12V output of the UC2000 Panel or with the same power supply used for the UC2000 Panel. 12

IN / OUT Reader for Single Door Wiring (One Panel for One Door) Cable Requirements: Shielded Twisted pair 2 conductors 1822 AWG Max. Distance: 500 feet between Door Lock and UC2000 500 feet between Exit Button and UC2000 500 feet between Magnetic Contact and UC2000 Power Source for Door Lock 12Vdc or 24Vdc Magnetic Contact ( Door Status Sensor ) 1N4007 Door Lock Other Requirement: Single end grounding for every Cable Shield Entry Reader Exit Reader Exit Button (Optional) 1 2 4 5 3 1 Tips: 1. A diode 1N4007 MUST be installed across every electrical switching device (Door Lock) run through a relay contact on the UC2000 Panel. The diode protects the UC2000 Panel from the power generated by the collapsing magnetic field of the electrical load device. 2. DON'T power door locks with the 12V output of the UC2000 Panel or with the same power supply used for the UC2000 Panel. 13

Important Notice 1. A diode 1N4007 MUST be installed across every electrical switching device (Door Lock) run through a relay contact on the UC2000 Panel (Fig. 1). The diode protects the UC2000 Panel from the power generated by the collapsing magnetic field of the electrical load device. 2. Use a separate 12Vac power supply (DON'T use 12Vdc power supply) or transformer to power the UC2000 panel. 3. DON'T power door Locks with the 12V output of the UC2000 Panel or with the same power supply used for the UC 2000 Panel. COM NC NO COM NC NO 1N4007 1N4007 Door Lock Door Lock Power Source for Door Lock 12Vdc or 24Vdc Fig. 1 Correct 1N4007 Installation COM NC NO COM NC NO 1N4007 Door Lock Door Lock Fig. 2 Wrong 1N4007 Installation Power Source for Door Lock 12Vdc or 24Vdc The 1N4007 DOES NOT provide any protection function ABSOLUTELY for this installation. COM NC NO COM NC NO Door Lock Door Lock Fig. 3 Wrong 1N4007 Installation Power Source for Door Lock 12Vdc or 24Vdc 1N4007 The 1N4007 DOES NOT provide any protection function ABSOLUTELY for this installation. 14