SONET Topologies and Upgrades

Similar documents
SONET Topologies and Upgrades

Add and Remove Nodes

Add and Remove Nodes

Add and Remove Nodes

Common Issues With Two Fiber Bidirectional Line Switched Rings

Card Protection. 4.1 Overview CHAPTER

Convert Network Configurations

Add and Remove Nodes

Create Circuits and VT Tunnels

Error Messages Troubleshooting

Best Practices When Configuring Circuits on the ONS 15454

Create Circuits. Before You Begin CHAPTER

System Applications Description

Manage Circuits. Before You Begin CHAPTER

CE Ethernet Operation

General Troubleshooting

SONET Bidirectional Line-Switched Ring Equipment Generic Criteria

Create Circuits and Low-Order Tunnels

Create Circuits and Low-Order Tunnels

General Troubleshooting

DWDM Topologies CHAPTER. This chapter explains Cisco ONS dense wavelength division multiplexing (DWDM) topologies.

CTC Information and Shortcuts

Upgrade, Add, and Remove Cards and Nodes

CTC Information and Shortcuts

Introduction Metro Area Optical Networks Components of a MAN Metro Service POP Core MAN Services Access Services Metro Optical Services Service POP

Configuring Resilient Packet Ring on the ML-Series Card

Protection Schemes and Network Topologies

Create Circuits and VT Tunnels

Circuits and Tunnels CHAPTER

Circuits and Tunnels CHAPTER

Optical Fiber Communications. Optical Networks- unit 5

CTC Information and Shortcuts

Upgrading Cisco ONS to Release 6.0

Upgrade, Add, and Remove Cards and Nodes

ECE442 Communications Lecture 4. Optical Networks

Create Circuits and Low-Order Tunnels

CTC Information and Shortcuts

Upgrading the Cisco ONS to Release 7.2

Ethernet Cards. 5.1 Card Overview CHAPTER

Card Protection. 7.1 Electrical Card Protection CHAPTER

Storage Access Networking Cards

Create Circuits. Before You Begin CHAPTER

Configuring Cisco Proprietary Resilient Packet Ring

Circuits and Tunnels Overview CHAPTER

Configuring Resilient Packet Ring

Fault management. Acnowledgements

For internal circulation of BSNL only

Error Messages. Error Messages Reference

Benefits of Metropolitan Mesh Optical Networks

Error Messages. Error Messages Reference

A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.

Turn Up a Node. Before You Begin CHAPTER

Error Messages CHAPTER

Synchronous Optical Networking Service (SONETS)

Circuits and Tunnels CHAPTER

Cisco Transport Controller Operation

Installing Cisco ONS SONET/SDH MRC-12 Cards

Manage Circuits. Before You Begin CHAPTER. This chapter explains how to manage Cisco ONS SDH electrical, optical and Ethernet circuits.

Transport is now key for extended SAN applications. Main factors required in SAN interconnect transport solutions are:

Fault management. Fault management. Acnowledgements. The impact of network failures. Pag. 1. Inspired by

CISCO WDM SERIES OF CWDM PASSIVE DEVICES

Unavailability Analysis of Long-Haul Networks

E-Series and G-Series Ethernet Cards

Network Topologies & Error Performance Monitoring in SDH Technology

Chapter 8 Switching Networks

Different network topologies

You must add the same user name and password to each node the user accesses.

Ethernet Features and Functions

Transmission Technology Ses SDH

Network Definition A network can be defined as two or more computers connected together in such a way that they can share resources.

Error Messages CHAPTER

Optical Communications and Networking 朱祖勍. Nov. 27, 2017

CONNECTICUT ACCESS SERVICE TARIFF. The Southern New England Original Page 22-1 Telephone Company d/b/a Frontier Communications of Connecticut

Generalized Multiprotocol Label Switching (GMPLS)

Types of Computer Networks and their Topologies Three important groups of computer networks: LAN, MAN, WAN

Upgrading the Cisco ONS CL to Release 7.0

2. The initialization vector (IV) is used in the framework of

SYSC 5801 Protection and Restoration

Bridging the Ring-Mesh Dichotomy with p-cycles:

Optical Cards. 4.1 OC-N Cards OC-N Card Overview CHAPTER

System Description NT7E65DJ What s inside... SONET Transmission Products S/DMS TransportNode OC-3/OC-12 NE TBM

Optical Channel Circuits and Virtual Patchcords Reference

(1) OC-3/OC-3c provides channels operating at the terminating bit rate of Mbps;

Digital Cross-Connect System (DCS) Aggregation and Grooming Solutions

CTC Information and Shortcuts

Project-Based Learning of Telecommunication Networking. Abstract

CTC Information and Shortcuts

SHARED MESH RESTORATION IN OPTICAL NETWORKS

Alcatel-Lucent 1675 LambdaUnite MultiService Switch

Alcatel 1696 Metro Span. Metropolitan DWDM System

Overview of the ML-Series Card

Ethernet Cards. 5.1 Ethernet Card Overview CHAPTER

Unless otherwise specified, ONS refers to both ANSI and ETSI shelf assemblies.

Introduction to Networks

Introduction to Networks Network Types. BTEC Nat IT Computer Networks

Guide to Networking Essentials Fifth Edition. Chapter 2 Network Design Essentials

MODERN RECOVERY MECHANISMS FOR DATA TRANSPORT NETWORKS

TARIFF DISTRIBUTION. DATE: June 15, Metro Ethernet and SMARTRing -- new interconnection capability

CHAPTER I INTRODUCTION. In Communication Networks, Survivability is an important factor

PART 8 - Special Access Services - West - NV 1st Revised Page 1 SECTION 21 - Optical Carrier Network (OCN) PTP

Transcription:

8 CHAPTER Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This chapter explains Cisco ONS 15600 SONET topologies and upgrades. To provision topologies, refer to the Cisco ONS 15600 Procedure Guide. Chapter topics include: 8.1 Overview, page 8-1 8.2 Point-to-Point and Linear ADM Configurations, page 8-2 8.3 Bidirectional Line Switched Rings, page 8-2 8.4 Path-Protected Mesh Networks, page 8-11 8.5 In-Service Topology Upgrades, page 8-13 8.1 Overview The ONS 15600 usually operates as a hub node in networks that include s, ONS 15327s, and ONS 15310-CLs. Single nodes are installed at geographic locations where several ONS SONET topologies converge. A single ONS 15600 node might be a part of several ONS SONET rings/networks. To avoid errors during network configuration, Cisco recommends that you draw the complete ONS SONET network topology on paper (or electronically) before you begin the physical implementation. A sketch ensures that you have adequate slots, cards, and fibers to complete the topology. 8-1

8.2 Point-to-Point and Linear ADM Configurations Chapter 8 8.2 Point-to-Point and Linear ADM Configurations You can configure ONS 15600s as a line of add/drop multiplexers (ADMs) by configuring one OC-N port as the working path and a second port as the protect path. Unlike rings, point-to-point (two node configurations) and linear (three node configurations) ADMs require that the OC-N ports at each node are in 1+1 protection to ensure that a break to the working path automatically routes traffic to the protect path. Figure 8-1 shows two ONS 15600 nodes in a point-to-point ADM configuration. Working traffic flows from Slot 1/ at to Slot 1/ at. You create the protect path by creating a 1+1 configuration with Slot 1/ and Slot 2/ at Nodes 1 and 2. Figure 8-1 Point-to-Point ADM Configuration Slot 1/ to Slot 1/ Slot 2/ to Slot 2/ 98292 Working Path Protect Path 8.3 Bidirectional Line Switched Rings The ONS 15600 can support up to 32 bidirectional line switched rings (BLSRs). Eight four-fiber BLSR rings can be supported if all ports are OC-192. Because the working and protect bandwidths must be equal, you can create only OC-48 or OC-192 BLSRs. For information about BLSR protection channels, see the 7.7 Protection Channel Access Circuits section on page 7-15. Note For best performance, BLSRs should have one LAN connection for every ten nodes in the BLSR. 8.3.1 Two-Fiber BLSRs In two-fiber BLSRs, each fiber is divided into working and protect bandwidths. For example, in an OC-48 BLSR, STSs 1 to 24 carry the working traffic, and STSs 25 to 48 are reserved for protection (Figure 8-2). Working traffic (STSs 1 to 24) travels in one direction on one fiber and in the opposite direction on the second fiber. Cisco Transport Controller (CTC) circuit routing routines calculate the shortest path for circuits based on many factors, including user requirements, traffic patterns, and distance. For example, in Figure 8-2, circuits going from Node 0 to will typically travel on Fiber 1, unless that fiber is full, in which case circuits will be routed to Fiber 2 through and. Traffic from Node 0 to (or to ) can be routed on either fiber, depending on circuit provisioning requirements and traffic loads. 8-2

Chapter 8 8.3.1 Two-Fiber BLSRs Figure 8-2 Four-Node, Two-Fiber BLSR STSs 1-24 (working) STSs 25-48 (protect) Node 0 STSs 1-24 (working) STSs 25-48 (protect) OC-48 Ring = Fiber 1 = Fiber 2 96671 The SONET K1, K2, and K3 bytes carry the information that governs BLSR protection switches. Each BLSR node monitors the K bytes to determine when to switch the SONET signal to an alternate physical path. The K bytes communicate failure conditions and actions taken between nodes in the ring. If a break occurs on one fiber, working traffic targeted for a node beyond the break switches to the protect bandwidth on the second fiber. The traffic travels in a reverse direction on the protect bandwidth until it reaches its destination node. At that point, traffic is switched back to the working bandwidth. Figure 8-3 shows a traffic pattern sample on a four-node, two-fiber BLSR. 8-3

8.3.1 Two-Fiber BLSRs Chapter 8 Figure 8-3 Four-Node, Two-Fiber BLSR Traffic Pattern Sample Node 0 OC-48 Ring Traffic flow Fiber 1 Fiber 2 96672 Figure 8-4 shows how traffic is rerouted following a line break between Node 0 and. All circuits originating on Node 0 that carried traffic to on Fiber 2 are switched to the protect bandwidth of Fiber 1. For example, a circuit carrying traffic on STS-1 on Fiber 2 is switched to STS-25 on Fiber 1. A circuit carried on STS-2 on Fiber 2 is switched to STS-26 on Fiber 1. Fiber 1 carries the circuit to (the original routing destination). switches the circuit back to STS-1 on Fiber 2 where it is routed to on STS-1. Circuits originating on that normally carry traffic to Node 0 on Fiber 1 switch to the protect bandwidth of Fiber 2 at. For example, a circuit carrying traffic on STS-2 on Fiber 1 switches to STS-26 on Fiber 2. Fiber 2 carries the circuit to Node 0 where the circuit switches back to STS-2 on Fiber 1 and is then dropped to its destination. 8-4

Chapter 8 8.3.2 Four-Fiber BLSRs Figure 8-4 Four-Node, Two-Fiber BLSR Traffic Pattern Following Line Break Node 0 OC-48 Ring Traffic flow Fiber 1 Fiber 2 96673 8.3.2 Four-Fiber BLSRs Four-fiber BLSRs double the bandwidth of two-fiber BLSRs. Because they allow span switching as well as ring switching, four-fiber BLSRs increase the reliability and flexibility of traffic protection. Two fibers are allocated for working traffic and two fibers for protection, as shown in Figure 8-5. To implement a four-fiber BLSR, you can install either two or four OC-48 or OC-192 cards at each BLSR node. 8-5

8.3.2 Four-Fiber BLSRs Chapter 8 Figure 8-5 Four-Node, Four-Fiber BLSR Node 0 Span 4 Span 1 Span 5 Span 8 OC-48 Ring Span 6 Span 7 Span 3 Span 2 = Working fibers = Protect fibers 131781 Four-fiber BLSRs provide span and ring switching: Span switching (Figure 8-6 on page 8-7) occurs when a working span fails. Traffic switches to the protect fibers between the nodes (Node 0 and in the example in Figure 8-6) and then returns to the working fibers. Multiple span switches can occur at the same time. 8-6

Chapter 8 8.3.2 Four-Fiber BLSRs Figure 8-6 Four-Fiber BLSR Span Switch Node 0 Span 4 Span 1 Span 5 Span 8 OC-48 Ring Span 6 Span 7 Span 3 Span 2 = Working fibers = Protect fibers 131783 Ring switching (Figure 8-7) occurs when a span switch cannot recover traffic, such as when both the working and protect fibers fail on the same span. In a ring switch, traffic is routed to the protect fibers throughout the full ring. 8-7

8.3.3 BLSR Bandwidth Chapter 8 Figure 8-7 Four-Fiber BLSR Ring Switch Node 0 Span 4 Span 1 Span 5 Span 8 OC-48 Ring Span 6 Span 7 Span 3 Span 2 = Working fibers = Protect fibers 131784 8.3.3 BLSR Bandwidth BLSR nodes can terminate traffic coming from either side of the ring. Therefore, BLSRs are suited for distributed node-to-node traffic applications such as interoffice networks and access networks. BLSRs allow bandwidth to be reused around the ring and can carry more traffic than a network with traffic flowing through one central hub. BLSRs can also carry more traffic than a path protection operating at the same OC-N rate. Table 8-1 shows the bidirectional bandwidth capacities of two-fiber BLSRs. The capacity is the OC-N rate divided by two, multiplied by the number of nodes in the ring minus the number of pass-through STS-1 circuits. Table 8-1 Two-Fiber BLSR Capacity OC Rate Working Bandwidth Protection Bandwidth Ring Capacity OC-48 STS 1-24 STS 25-48 24 x N 1 PT 2 OC-192 STS 1-96 STS 97-192 96 x N PT 1. N equals the number of ONS 15600 nodes configured as BLSR nodes. 2. PT equals the number of STS-1 circuits passed through ONS 15600 nodes in the ring (capacity can vary depending on the traffic pattern). Table 8-2 shows the bidirectional bandwidth capacities of four-fiber BLSRs. 8-8

Chapter 8 8.3.4 BLSR Fiber Connections Table 8-2 Four-Fiber BLSR Capacity OC Rate Working Bandwidth Protection Bandwidth Ring Capacity OC-48 STS 1-48 (Fiber 1) STS 1-48 (Fiber 2) 48 x N 1 PT 2 OC-192 STS 1-192 (Fiber 1) STS 1-192 (Fiber 2) 192 x N PT 1. N equals the number of ONS 15600 nodes configured as BLSR nodes. 2. PT equals the number of STS-1 circuits passed through ONS 15600 nodes in the ring (capacity can vary depending on the traffic pattern). Figure 8-8 shows an example of BLSR bandwidth reuse. The same STS carries three different traffic sets simultaneously on different spans around the ring: one set from to, another set from to, and another set from to. Figure 8-8 BLSR Bandwidth Reuse Node 0 STS 1 STS 1 STS 1 STS 1 = traffic = traffic = traffic 96662 8.3.4 BLSR Fiber Connections Plan your fiber connections and use the same plan for all BLSR nodes. For example, make the east port the farthest slot to the right and the west port the farthest slot to the left. Plug fiber connected to an east port at one node into the west port on an adjacent node. Figure 8-9 shows fiber connections for a two-fiber BLSR with trunk (span) ports in Slot 4 (west) and (east). Refer to the Cisco ONS 15600 Procedure Guide for fiber connection procedures. 8-9

8.3.4 BLSR Fiber Connections Chapter 8 Note Always plug the transmit () connector of an OC-N port at one node into the receive () connector of an OC-N port at the adjacent node. Cards display an SF LED when and connections are mismatched. Figure 8-9 Connecting Fiber to a Four-Node, Two-Fiber BLSR Slot 4 Port 3 Slot 4 Port 3 Slot 4 Port 3 Slot 4 Port 3 96663 Node 4 For four-fiber BLSRs, use the same east-west connection pattern for the working and protect fibers. Do not mix working and protect port connections. The BLSR does not function if working and protect ports are interconnected. Figure 8-10 shows fiber connections for a four-fiber BLSR. Slot 2/Port 7 (west) and /1 (east) carry the working traffic. Slot 3/ (west) and Slot 13/ (east) carry the protect traffic. 8-10

Chapter 8 8.4 Path-Protected Mesh Networks Figure 8-10 Connecting Fiber to a Four-Node, Four-Fiber BLSR Slot 2 Slot 3 Port 7 1 Slot 13 Slot 2 Port 7 Slot 3 1 Slot 13 Slot 2 Slot 3 Port 7 1 Slot 13 Slot 2 Port 7 Slot 3 1 Slot 13 Node 4 Working fibers Protect fibers 131782 8.4 Path-Protected Mesh Networks In addition to single BLSRs, path protectionconfigurations, and ADMs, you can extend ONS 15600 traffic protection by creating path-protected mesh networks (PPMNs). PPMNs include multiple ONS 15600 SONET topologies and extend the protection provided by a single path protection to the meshed architecture of several interconnecting rings. In a PPMN, circuits travel diverse paths through a network of single or multiple meshed rings. When you create circuits, CTC automatically routes circuits across the PPMN, or you can manually route them. You can also choose levels of circuit protection. For example, if you choose full protection, CTC creates an alternate route for the circuit in addition to the main route. The second route follows a unique path through the network between the source and destination and sets up a second set of cross-connections. For example, in Figure 8-11, a circuit is created from to Node 9. CTC determines that the shortest route between the two nodes passes through Node 8 and Node 7, shown by the dotted line, and automatically creates cross-connections at Nodes 3, 8, 7, and 9 to provide the primary circuit path. 8-11

8.4 Path-Protected Mesh Networks Chapter 8 Figure 8-11 Path-Protected Mesh Network Source Node Node 5 Node 4 0 Node 8 Node 6 Node 7 1 Protect traffic Node 9 Working traffic Destination Node = Primary path = Secondary path 78706 If full protection is selected, CTC creates a second unique route between Nodes 3 and 9 that passes through Nodes 2, 1, and 11. Cross-connections are automatically created at Nodes, 3, 2, 1, 11, and 9, shown by the dashed line. If a failure occurs on the primary path, traffic switches to the second circuit path. In this example, Node 9 switches from the fiber from Node 7 to the fiber from 1 and service resumes. The switch occurs within 50 ms. PPMN also allows spans of different SONET line rates to be mixed together in virtual rings. Figure 8-12 shows Nodes 1, 2, 3, and 4 in an OC-192 ring. 8-12

Chapter 8 8.5 In-Service Topology Upgrades Figure 8-12 PPMN Virtual Ring Node 5 Node 4 Node 8 OC-12 OC-48 OC-12 32137 Node 6 Node 7 8.5 In-Service Topology Upgrades Topology upgrades can be performed in-service to convert a live network to a different topology. An in-service topology upgrade is potentially service-affecting, and generally allows a traffic hit of 50 ms or less. Traffic might not be protected during the upgrade. The following in-service topology upgrades are supported: Point-to-point or linear ADM to two-fiber BLSR Two-fiber BLSR to four-fiber BLSR Node addition or removal from an existing topology You can perform in-service topology upgrades irrespective of the service state of the involved cross-connects or circuits, however all circuits must have a DISCOVERED status. ONS 15600 circuit types supported for in-service topology upgrades are: Synchronous transport signal (STS) Unidirectional and bidirectional Automatically routed and manually routed CTC-created and TL1-created Ethernet (unstitched) Multiple source and destination (both sources should be on one node and both drops on one node) You cannot upgrade stitched Ethernet circuits during topology conversions. For in-service topology upgrade procedures, refer to the Convert Network Configurations chapter in the Cisco ONS 15600 Procedure Guide. For procedures to add or remove a node, refer to the Add and Remove Nodes chapter of the Cisco ONS 15600 Procedure Guide. 8-13

8.5.1 Point-to-Point or Linear ADM to Two-Fiber BLSR Chapter 8 Note A database restore on all nodes in a topology returns converted circuits to their original topology. Note Open-ended path protection and DRI configurations do not support in-service topology upgrades. 8.5.1 Point-to-Point or Linear ADM to Two-Fiber BLSR A 1+1 point-to-point or linear ADM to two-fiber BLSR conversion is manual. You must remove the protect fibers from all nodes in the linear ADM and route them from the end node to the protect port on the other end node. In addition, you must delete the circuit paths that are located in the bandwidth that will become the protection portion of the two-fiber BLSR (for example, circuits in STS 25 or higher on an OC-48 BLSR) and recreate them in the appropriate bandwidth. Finally, you must provision the nodes as BLSR nodes. 8.5.2 Two-Fiber BLSR to Four-Fiber BLSR CTC provides a wizard to convert two-fiber OC-48 or OC-192 BLSRs to four-fiber BLSRs. To convert the BLSR, you must install two OC-48 or OC-192 ports at each two-fiber BLSR node, then log into CTC and convert each node from two-fiber to four-fiber. The fibers that were divided into working and protect bandwidths for the two-fiber BLSR are now fully allocated for working BLSR traffic. 8.5.3 Add or Remove a Node from a Topology You can add or remove a node from a linear ADM, BLSR, or path protection configuration. Adding or removing nodes from BLSRs is potentially service affecting, however adding and removing nodes from an existing 1+1 linear ADM or path protection configuration does not disrupt traffic. CTC provides a wizard for adding a node to a point-to-point or 1+1 linear ADM. This wizard is used when adding a node between two other nodes. 8-14