Product Specifications

Similar documents
Specifications FEATURES

Its 16-bit ADC makes ilog data loggers well suited for science and laboratory applications where precise and accurate measurements are critical.

SITE-LOG LFVB. Product Specifications

SITE-LOG LPTH-1. Product Specifications. recognizes it and handles the configuration, downloading, graph viewing and more OVERVIEW

User s Manual Microedge Instruments Inc North Bluff Road. White Rock, BC, Canada, V4B 0A7. Toll Free:

User s Manual Microedge Instruments Inc.

Vaisala Veriteq VL 2000 Temperature Humidity Loggers

USB-5100 Series Multi-Channel Data Loggers

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-5100 Series Multi-Channel Data Loggers

Stand-Alone, Low-Cost Data Loggers and Accessories. USB-500/600 Series Comparison Chart

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

CS200 DIGITAL MFC SOFTWARE 2.0

TITAN S8. Portable Data Acquisition Logger. Product User Guide

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

Specifications Minimum Typical Maximum Unit

TITAN S8. Transportable Data Acquisition Device. Product Brochure EN

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

DD-600. A member of the Data Dolphin Family of Data Logging Systems. Data Dolphin Installation and Usage Manual

Operation Manual for Multifunctional Data Logger. HUATO Electronic Co., LTD.

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

X-Log Expert Data Logger

Temperature/Rh Data logger. Users Manual. USB Datalogger IP 65 Water Proof

8 or 16 Channel Universal Input Touch Screen Data Logger

8 or 16 Channel Universal Input Touch Screen Data Logger

Report Logger Manual Quick Start: V

Andover ContinuumTM Infinet II

BESANTEK USB Data Logger Instructional Manual (BST-DL10, BST-DL13, BST-DL14)

Software for HOBO loggers

Web-enabled DAQ System

WHIRLYBIRD AUTOMATIC WEATHER STATION. Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore

Wide measurement range Temperature operating range is 10 to 65ºC (15 to 150ºF); RH range is 0 to 99% non-condensing.

Sefram SEFRAM DAS 20/DAS 40. Sefram

Q.brixx station 101. Base Unit with Test Controller. Most important features:

Humidity & Temperature Datalogger

Notes on installing and using the OM-USB-5201 and OM-USB-5203 data logging devices

High Voltage DC Meter

3-Axis G-Force Datalogger

Product User Guide. QuadTemp and OctTemp. QuadTemp 4-Channel Thermocouple Based Temperature Data Logger

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner

HIGH-VOLTAGE DC METER

Phone: Fax: For calls outside the US please call:

TALON Network Manager- 2 & 6 Express

USB to RS-422 / 485. US USB To Serial Operation Manual

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

BACnet. b3810 Series Local Controllers

AGATE TECHNOLOGY AT-2040

and/or b. an optional internal Iridium satellite modem.

TSM1 Infrared Data Logger

Temperature/Humidity Data Logger with 2 Universal External Inputs

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

SERIES E L I T - -J. Authorized distributor in Australia:

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

DataNet Solution. Wireless intelligent logging network. Sense it. Manage it. H E

3-Axis G-Force Datalogger

WiFi Temperature Transmitter V6

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

User Manual MPPTracker

Scannex rt.buffer Overview

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

A NEW DATA LOGGER Stand alone. Secure. Fast.

ENGINEERING SPECIFICATIONS SENSAPHONE 2000

BoxCar Pro 4.3 for Windows

TFS 2100 Traveling Wave Fault Location System

Data logger systems from ROTRONIC

ADC-20 and ADC-24 High resolution data logger

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

TPM Operation Manual

WiFi Counter/Temperature Transmitter

The new Expert Logger 400: Industry 4.0 ready!

Product User Guide. OctProcessV2 and QuadProcessV2. QuadProcessV2-3A 4-Channel Low Level DC Current

ULTRALOW POWER 24-BIT DUAL SEISMIC DATA RECORDER WITH INTERNAL SCU CONTROLLER Model DR4050-A-SCU/IF

LBVR1718. Description. Features channel paperless recorder

Wireless Data Logger System

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

User s Guide. OM-EL-WiFi-TH. Shop online at omega.com. OM-EL-WiFi-TP-PLUS. Probe Data Logging Sensor

Quattro Flow. Air Velocity Analyzers. Mobile Multipoint Evaluation CAMBRIDGE ACCUSENSE, INC.

TC Compact Series Unitary Equipment Controller

Decagon Devices, Inc. Version: February 29, :38:47

BESTCOMSPlus Software

DL6 Data Logger. Quick Start Guide Version 1.2. Delta-T Devices Ltd

MEDICAL, PHARMACEUTICAL & VETERINARY TEMPERATURE & HUMIDITY DATA LOGGERS

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

Dual Channel LVDT/RVDT Readout/Controller

RST INSTRUMENTS LTD.

ZLog Z6R Altitude Data Recording and Monitoring System

Features. IDS : Inclinometer Display System with RS232 Output

ACR89 Handheld Smart Card Reader Technical Specifications. Datenblatt / Specifications

MINI CLOCK TRAVEL PORTABLE FCC CE. SKU: MiniClockTravel USER MANUAL THANK YOU FOR PURCHASING THE MINI CLOCK TRAVEL

A-307. Mobile Data Terminal. Android OS Platform Datasheet

GS828-H. GPRS Data Logger

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

Synergy Controller Application Note 1 September 2014, Revision F Tidal Engineering Corporation 2014

USB Temperature and Humidity Data Logger Instruction Manual

8 CHANNEL ANALOG DATA LOGGER

CORD-XL Dual-Channel Electronic Chart Recorder User s Manual

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

SCADAPack Smart RTU

JT400 Multivariable Transmitter

Transcription:

407 15216 North Bluff Road White Rock, BC Canada V4B 0A7 Phone: 604.424.9092 Toll Free: 1.877.352.9158 Fax: 1.877.453.0658 Email: info@microedgeinstruments.com Web: www.microedgeinstruments.com Product Specifications OVERVIEW The is low cost, high accuracy, battery powered, stand-alone voltage data logger. The logger records up to 4 mega-byte of data and stores them in nonvolatile flash memory for later retrieval. Input voltage signal can be from sensors, transducers, transmitters or any other common voltage sources. Its on-board temperature channel provides environment monitoring and temperature compensation. Its aluminum enclosure makes it excellent in the harshest industrial environment. Plug & Play USB port and versatile custom equation simplify communications and engineering unit conversion. 16-bit ADC makes it well suited for science and laboratory applications where precise and accurate measurements are critical. Simply plug the logger to computer's USB port, and the software automatically recognizes it and handles the configuration, downloading, graph viewing and more... FEATURES High Data Resolution: The 16-bit analog-to-digital converter meets most high-resolution requirements. Large Memory Size: The 4-Mega-Byte Memory stores years of measurements. Free Upgrade of Software: Specifications Page 1 of 5

Both firmware and PC software are free for upgrade by couple of mouse clicks, keeping the logger and software always up-to-date with new features and bug fixes. Multiple Communication Ports: The ilog data loggers can be accessed via USB, Serial Port, MODEM, or Ethernet connections with auto baud rate of up to 115 kbps. Its on-board TTL serial port and USB interfaces meet most communication requirements. The ilog data logger notifies the alarm condition over alarm terminal strips or communication lines. (USB, Serial Port, MODEM) Excitation control turns on the power of external transmitter/transducer only when the logger is sampling. Alarm & Excitation Control USB Port TTL Serial Port 12-Year Battery Life: The internal lithium battery provides over 12 years of instantaneous logging operation when sampling at an interval of one minute. Fast Sampling Mode: The ilog data loggers can log data with the sampling interval as fast as 20 milliseconds, replacing data acquisition devices. Alarm and Excitation Output: Rugged Physical Design: The rugged aluminum enclosure makes the ilog data loggers perfect in the harshest industrial environment. Aluminum Case SITEVIEW SOFTWARE FEATURES SiteView is a Windows-based application which works with ilog Series data loggers for downloading, configuration, data analyzing and plotting. Its user-friendly graphic interface plus powerful functionalities fit both novice and advanced users. Besides basic data logger configuration, downloading, SiteView includes other powerful features like: Specifications Page 2 of 5

Multiple Communications Interfaces: USB, Serial Port, Ethernet Custom Equation Editor with C# language meet any complicated measurement requirements Multiple Data Views and Custom Formatting of Axis, Line, Annotation & Comments. Real-Time Chart View/Recording and User Calibration Export to CSV, TEXT, BMP, JPG, TIF, PNG, GIF file format. Specifications Page 3 of 5

SPECIFICATIONS Product Identification Product Name Model Inputs Connections ivdc-10 Pluggable terminal block voltage input, alarm and excitation control outputs. Channels One on-board thermistor temperature (-40 C ~ 70 C, -40 F ~ 158 F). One 10VDC voltage channel Resolution 0.0018% Accuracy Input Impedence Over-voltage protection Alarms Channel Alarms Alarm Outputs Alarm-On Delay: Alarm Indicator On-board Memory Capacity Data Retention Sampling & Logging Sampling Interval Logging Mode Logging Activation Communications Interface Baud Rate Battery Power Life Cycle Software Site View (Sold Separately) Internal thermistor channel: ± 0.2 C(0 C ~ 70 C, 32 F ~ 158 F) External thermistor channels: ± 0.05% @ 25 C >1 MOhms up to -3VDC ~ +40VDC Two editable alarm thresholds per channel. ALARM1 & A2/EXT terminal strips can be configured as alarm outputs. Alarm-On: MOSFET(N-Channel) switch on. Alarm-Off: MOSFET(N-Channel) switch off. Max Power: 200mA @ 24VDC. With purchase of SiteView software, the Site-Log can report alarm status to host PC via USB, Modem or Ethernet Device Server. Programmable 0-10 minutes delay with 1-minute increments. On-board LED lights in red when in alarm condition. 4 Mega bytes (2 Mega measurements). Over 20 years. 20 milliseconds to 12 hours user selectable. (external power supply required if interval less than one second) Stop recording or FIFO when memory is full. Programmable instant, start delay or field push-button activation. USB(USB cable included). AUX(RJ11) for direct TTL level communications. With purchase of Site USB DeviceServer, the Site-Log logger can be connected to Ethernet for remote access. Auto-detect baud rate from 2400 to 115200 bps on both USB and AUX ports. Built-in 3.6V Lithium Battery. 12 years based on 1 minute sampling interval Configuration, downloading, plotting, real-time view, custom calibration and custom equation. Specifications Page 4 of 5

Software Requirements Computer with 1.0 GHz or faster processor 256 MB Memory or higher 1.0 GB of available hard-drive space or higher Windows XP with SP2 or later, Vista, Window 7 At least one USB port or one COM port Physical Material Aluminum enclosure. Dimension 88 X 64.2 X 24 mm (3.46 X 2.53 X 0.95 inches) Weight 200g. Mounting Probe/Wall-mount holes for hanging/mounting. Others LED Indicator Tri-Color LED: (can be disabled for power saving) Normal Sampling: green when sampling Alarm: red when sampling Low Battery: amber when sampling. Excitation Control A2/EXT terminal strip can be configured as excitation control output for driving the power of connected devices. Warm-up delay Interval settings: 10 to 240 seconds with 10- second increments. Operating Environment -40 ~ +70 C (-40 F ~ 158 F), 0~95%RH non-condensing. Clock Accuracy ± 1 minute per month. Approvals CE, FCC LOGGING CAPACITY TABLE Sampling Interval Logging Capacity Sampling Interval Logging Capacity 1 minute 727 days 1 second 12 days 10 seconds 121 days 100 ms 28 hours ORDERING INFORMATION Model Description ivdc-10 Specifications Page 5 of 5