Installing the License in an ESG Signal Generator

Similar documents
Organize Mail into Folders

How to use EquationEditor_Examples.txt with the Equation Editor function on the ENA Network Analyzer

Gauss/Tesla Meters. Application Note January 2013 Data Logging using HyperTerminal and SCPI Commands on the 8000 Series

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies

Floating License Server

Agilent MassHunter Workstation Software for Triple Quad LC/MS

Windows 2000 Safe Mode

8100 Mobile Device Test System. LTE RF Performance User Manual

License Conversion Procedure

Agilent PSA Spectrum Analyzer Firmware Upgrade Procedure

Tips & Tricks. LinkOne Information Required When Changing Computers LinkOne WinView (Version 5)

BUILD DEFINITION EXTENSION

Agilent OpenLAB Chromatography Data System (CDS)

Along the top of the Inbox is a toolbar with icons for commonly used functions within .

Orifice Flow Meter

Procedure to set up an HPIB 82350B card on an M57. M58 or C20x PC. Table 1: Parts required. Part Number Description Qty

How to Install, Configure and Use sftp (Windows Version)

Managing the System Event Log

Microsoft Office Outlook 2007: Intermediate Course 01 Customizing Outlook

v5: How to restore Exchange databases

1.4 MConfig PC software can be optionally used to upload/download configuration settings to the VRU Pro using RS-485 communication.

How to Journal to the Cloud Archiving Service from Microsoft Exchange Server 2007 and 2010

N7624B Signal Studio for LTE Technical Overview

Keysight Software

If this is the first time you have run SSMS, I recommend setting up the startup options so that the environment is set up the way you want it.

DNN Guidelines. User Manual for Admin Updating Content on Website. Version /07/2014

Using File Cabinet In OwlNet

VISA, SICL, VISA COM,

How to backup and restore a database in Microsoft SQL Server 2005 Step by step guide.

TREX Set-Up Guide: Creating a TREX Executable File for Windows

Installation Instructions for JMP Genomics 7.1

Managing the System Event Log

PROJECT MENTOR / MICROSOFT PROJECT INTEGRATION

How to Configure Impersonation for OneDrive for Business Data Sources

Installation Guide Worksoft Certify

To complete this project, you will need the following folder:

System Event Log. For example, sel-ucs-a-ch01-serv01-qci

Qlikview and TFS integration

Join Queries in Cognos Analytics Reporting

Migrating Eclipse.net from SQL Server 2005 to SQL Server 2008

Keysight N108xA-Series IEEE Ethernet KR/CR Compliance and Debug Application

Configure SharePoint Server 2010 as a single server with the Unitrends appliance. farm with the Unitrends appliance

Creating a Dashboard Prompt

8960 Fading with the PXB

Migrate from Microsoft Dynamics CRM Online to Microsoft Dynamics CRM (on-premises) Applies to: Microsoft Dynamics CRM Online 2015 Update 1

3 Administrative Tasks

Colligo Manager. White Labeling

Versions. Overview. OU Campus Versions Page 1 of 6

Managing the Startup Folder in Windows 8

THOR Router Management System. Quick Start Guide. Version 3.5

IntuiLink for Basic (Agilent E3600 series) DC Power Supplies

Cloud Attached Storage

CodeWarrior Development Studio for Freescale 68HC12/HCS12/HCS12X/XGATE Microcontrollers Quick Start SYSTEM REQUIREMENTS Hardware Operating System 200

Hands-On Lab. Authoring and Running Automated GUI Tests using Microsoft Test Manager 2012 and froglogic Squish. Lab version: 1.0.5

INSTALLATION OF PRO/ENGINEER WILDFIRE TRYOUT EDITION THE SAMPLE INSTALLATION INSTRUCTIONS TO FOLLOW ARE ONLY A GUIDE.

User Guide For Version 4.0

ipm Global CHAPTER 1 INSTALLATION CH 1 - p 1

INSTRUMENTS, INC. Model SOF8_1940

Exercise 1: Assigning Responsibilities to Delegates (This was called Proxy in GroupWise)

Dealing with Event Viewer

Office 365. Exporting and Importing Safe and Blocked Senders List

Agilent 89600B VSA. Software Installation Guide

Schools Cash Office. Instructions for SCO live migration to version 2.4

This document provides additional information for the installation and use of the Keithley I/O Layer.

The instructions were written for Windows 7. They have run without problems for Windows 8.

Restoring data from a backup

Advance Technologies; Automate the World.

RECOMMENDED PROCEDURE

Keysight Software. Installation Guide

SYSTOC to PureOHS Employer Portal Install and Upgrade Instructions

1. Navigate to in a browser.

Essentials Wizard Help - Configure Office 365

Before you begin, you need to make sure that IIS is installed on the runtime server.

Technical Bulletin DS2

Waters Empower Software A1100 System Configuration Instructions for Ethernet Control

R&S TSMA Release Notes Firmware Version

Setting the Management IP Address

PC and Windows Installation 32 and 64 bit Operating Systems

Exclaimer Mail Archiver

Agilent L4411A 6 ½ Digit Multimeter

HP BladeSystem Management Pack (v 1.x) for Microsoft System Center User Guide

Network installation guide. Version 3 27 th September 2016

LDAP Configuration Guide

User Manual. Open platform E Line. Part Number: Version: 1. Date:

Field PC 2 Windows OS Update Guide

Colligo Briefcase. White Labeling

Table of Contents. Knowledge Center -

ACTi IP Utility. Ver

Getting Started with IVI-COM Drivers for the Lambda Genesys Power Supply

RSA NetWitness Logs. Microsoft Network Access Protection. Event Source Log Configuration Guide. Last Modified: Thursday, May 18, 2017

A Tutorial for ECE 175

Field Calibration Software

Installation Note ESG Vector Signal Generator E4438C Add Option 005 (Internal Hard Drive) Kit Part Number E

Agilent 1260 Infinity Purification Solution

DATASTREAM CHART STUDIO GETTING STARTED

1 Connecting the indicator and launching Data Link

New Features in Firmware V2.02 (Compared to V2.01) New Features in Firmware V2.01 (Compared to V2.00)

Table of Contents. Installation Preface... 1 Prerequisites... 1 Installation Procedure... 1

Users' Guide, LabSoft - Local and Network Installation

Software Registration Instructions

Transcription:

Installing the License in an ESG Signal Generator Before installing the license file, save a backup copy in a safe place. To enable your ESG signal generator to play waveforms generated by the Signal Studio software, you must install a license file in the signal generator. Agilent sends you the license file by email when you redeem your license. To install the license file in your signal generator, follow the instructions below. Using Agilent License Manager The Agilent License Manager software requires a LAN connection between the PC on which it is installed and the ESG signal generator. If your equipment cannot be connected through a LAN, install the license using a GPIB connection and SCPI commands as described on page 4. 1. If you do not have Agilent License Manager installed on your PC, you can download it at no charge from the following website: http://www.agilent.com/find/licensemanager. 2. Establish a LAN connection between the PC running the Agilent License Manager software and the ESG signal generator as described in Equipment Setup and Connection in the Signal Studio online documentation. 3. Copy the license file to your PC. The license file has a.lic extension, and is attached to the email message you received when you redeemed your license (see Getting a License in the Signal Studio online documentation). In this example, the license file E4438C-US70000174.lic is placed in a folder named E4438C. 1

4. Obtain the hostname or IP address of your signal generator. Press Utility > GPIB/RS-232 LAN > LAN Setup on the signal generator front panel. The hostname and IP address are displayed as shown below. 5. On your PC, start the Agilent License Manager software. Click Start > All Programs > Agilent License Manager > Agilent License Manager. 2

6. In the Agilent Licence Manager main window, click File > Connect... to open the Connect to Device dialog box. 7. In the Device Address field, enter either the hostname or the IP address of the signal generator obtained in Step 4. 8. Click OK. The instrument address and its installed licenses appear in the tree view (left pane). The right pane displays additional information for each license. 3

9. Click File > Install License(s)... to open the Install License File(s) dialog box. 10. Use the Install License File(s) dialog box to navigate to the location where you placed the license file (*.lic) in Step 3. 11. Select the desired license file and click Open. 12. Wait for a message to appear, informing you that the license has been successfully installed in the signal generator. Refer to the Agilent License Manager online help for more information about using the software. 4

Using GPIB and SCPI Commands If you are unable to establish a LAN connection between your PC and your ESG signal generator, you can manually install the license using a GPIB or RS-232 connection and the Agilent Connection Expert software (or another command line tool). This method can be used for permanent and time-based licenses only. To install or move a transportable license, you must use the Agilent License Manager software on a PC connected to your ESG through a LAN as described in the previous section. 1. Copy the license file to your PC. The license file is attached to the email message you received when you redeemed your license (see Getting a License in the Signal Studio online documentation). 2. On your PC, start the Agilent Connection Expert software. Click Start > All Programs > Agilent IO Libraries Suite > Agilent Connection Expert. If you do not have Agilent IO Libraries Suite installed on your PC, you can download it from the following website: http://www.agilent.com/find/iolib. If you are not using Agilent Connection Expert, start your command line tool and proceed to step 6. 3. In the Instrument IO on this PC tree view, select the E4438C ESG signal generator connected via GPIB. 5

4. If the Task Guide view is not displayed, select View > Task Guide. 5. In the Tasks for This Instrument column, click Send Commands to this Instrument to open the Agilent Interactive IO window. 6. Open the license file you copied to your PC in Step 1 using Microsoft Notepad, or a similar text editor that creates plain, ASCII text files. Do not use a word processor such as Microsoft Word. 7. Using the text editor, select and copy the license file text. 6

8. Type the following SCPI command into the Command: field in the Agilent Interactive IO window, pasting the license file text you copied in Step 7 at the <license_line> location in the command. :SYST:LIC:INST <license_line> 9. Click the Send Command button to send the command, or the Send & Read button to send the command and read the response in the Instrument Session History displayed at the bottom of the window. 7