Pressure Transmitter and Reader of the PT-RF Series Manual

Similar documents
Operating Instruction PPC-04 /2

Stauff Hydraulic Tester PPC 06/08 plus. Manual Version 1.0 Part number:

Operating Instructions Bedienungsanleitung Mode d emploi Gebruiksaanwijzing Istruzioni per l uso Instrucciónes para el manejo HPM110


Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines

Installation and Operating Manual. VPC Merkur No. 5744

Daily use. indicating that the loud speakers

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

testo 184 Data logger Instruction manual

testo 176 Data loggers

Manometer. (Over- /Under- And Difference Pressure) Operating Manual GDH

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

Operating instructions. Speed monitor D / / 2014

USER MANUAL OVO MINI SPEAKER

M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

INSTRUCTION MANUAL CAT ecount

testo 176 Datenlogger testo 176 Data loggers testo 176 Enregistreur de données Bedienungsanleitung Instruction manual Mode d'emploi

Get set, go! Getting to know your go! stick USB modem. The package of your ACN go! stick contains the following items:

ENGLISH. User manual

SolConeX extra-low voltage flange socket

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

TA400 OPERATING MANUAL DYNAMIC PRESSURE ANEMOMETER TRT-BA-TA400-TC-002-EN

B63/ NS MS. EtherNet/IP LINK

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Operating Instructions

Technaxx * User Manual Power Bank 6000mAh with FullHD Camera TX-92

Precision hand-held pressure indicator Model CPH6400

Druck DPI 620 advanced modular calibrator

Thank you for your purchase USER MANUAL

User manual BT7900. Register your product and get support at

FlashMax P4 Ortho Manual

Operating Instructions VEGAMET 381

Flash Max P W. Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating Instructions for Orderman Sol & Sol+

Manual Differential pressure meter PCE-910 / PCE-917

Tx Link. Quick Setup Guide. English. Connection module

Stanley TLM 130i.book Page 1 Tuesday, February 5, :00 PM

COMPACT LED DESK LAMP WITH LCD DISPLAY

Instruction Manual Extreme Temperature (XT) Data Logger

Operating instructions. Standstill monitor A / / 2011

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

TVAC25100 TVAC25110 User manual

Lenovo S60-a. Quick Start Guide. Read this guide carefully before using your smartphone.

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

testo 175 Data loggers Instruction manual

Kolectric Research. MC8022 Covermeter. Document number IM Iss 1 Copyright 2014 Tallix Ltd

STYLISH LED DESK LAMP WITH DIFFERENT LIGHT MODES

User Guide Microsoft Portable Power (DC-21)

Hygro-/Thermometer. Operating Manual GFTH 95

Operating Instructions for Digital Thermometers. Model: DTM

ZipCharge. User Guide. Ultra fast-charging portable power stick. Revision 1.04

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

N) manual. Eppendorf TrackIT. Operating manual 1.0

V-Switch 3 User Guide

Digital Night Vision Device Digital+ Series NV-440D3/NV-650D3/NV-760D3

Multi-touch Touch-Screen. Installation Guide

BLUETOOTH SPEAKER GSB 600 NFC

Product manual plug, sockets and coupler 16 A.- Z0251

IS35 Color Display. User Manual ENGLISH. simrad-yachting.com

BLUETOOTH SPEAKER GSB 2000

Ball Probe Moisture Meter With Bluetooth

LM-100 LM-120 Light Meters Users Manual

Network Camera. Quick Guide DC-B1203X. Powered by

SOLAR POWER METER TM-206. User s Manual HB1TM

Powergate³ User. Instruction manual and user s guide

BLUETOOTH SPEAKER BLUEBEAT GSB 110

Instruction Manual. T3110 T3110L T3110Ex

24V, Motorized Actuators

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

English. Instruction and operation manual S 505. Dew point meter (portable)

Installation Instruction. HART Add-On Module

High Performance Infrared Thermometer with High D:S Ratio, Adjustable Emissivity, and Built-in Laser Sighting

Digital Quick-Response Thermometer

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

User Manual Revised 1-July-2015

Please read and retain these instructions for future reference. Cradle, Charger, Instruction manual, 3.7V Lithium-ion battery included.

Manual Light Meter PCE -174

Instruction Manual RS-1660

WA4204-G2/G3 and WA4304-G2/G3

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

SLIMLINE DASH CAM Audio & Video Recorder

6 Rainbow Mobile Phones with Docking Station USER GUIDE.

User s Manual Power Supply IM E. 5th Edition

RS Stock No Instruction Manual RS Input Data Logging Thermometer

GB/UK. Operating manual. Data logger EBI USB

N) manual. Eppendorf TrackIT. Operating manual 1.0

Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

SR200 GPS SPORTS WATCH. Keeping you one step ahead. User manual

BIOFOB 1S Remote Fingerprint Access Control. English. User Operation Manual

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300. Retain these instructions for future reference

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Operating Instructions

Operating instructions Memory plug E /02 11/2011

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

External level devices for conductive point level switch

Transcription:

Local Solutions For Individual Customers Worldwide Pressure Transmitter and Reader of the PT-RF Series Manual

Contents 1 Safety instructions... 3 1.1 Intended use... 3 1.2 Specialist personnel... 3 1.3 Accuracy of technical documentation... 3 1.4 High-pressure applications... 4 1.5 Service/repairs... 5 1.6 Information about disposal... 5 2 Scope of Supply... 7 3 Reading device Reader-PT-RF... 8 4 Pressure transmitter PT-RF... 9 4.1 Installing the pressure transmitters... 9 5 Carrying out a measurement... 10 5.1 Preparing a measurement... 10 5.2 Individual measurement... 12 5.3 Continuous measurement... 13 6 Functions... 15 6.1 Storage battery... 15 6.2 Energy saving function... 15 6.3 Status indicator (LED)... 16 6.4 Measurement process... 17 7 Software... 18 7.1 Installation... 18 7.2 The Interface... 19 7.3 Connecting a reader... 20 7.4 The measurement list... 20 7.5 Function-Buttons... 22 7.6 Set-Buttons... 23 7.7 Filter Options... 24 8 Maintenance/cleaning/repairs... 25 8.1 Repairs and Service... 25 9 Technical Data... 26 9.1 Pressure transmitter... 26 9.2 Reading device... 27 Operating instructions PT-RF V1.2 page 2 of 27

1 Safety instructions 1.1 Intended use This portable reading device is intended for measuring, storing and monitoring measuring values, e.g. for service and maintenance work as well as in the field of machine optimisation. The device is only intended for use with a pressure transmitter and accessories from the STAUFF PT-RF accessories range. Any other use is not permitted. This can lead to accidents or destruction of the device and will result in immediate expiration of any warranty and guarantee claims towards the manufacturer. Warning Using the selected product outside the specifications or disregarding the operating and warning information can result in serious malfunctions that may cause injuries and property damage. The device must not be operated in explosive atmosphere! 1.2 Specialist personnel These operating instructions are intended for trained specialist personnel who are familiar with the current regulations and standards for the area of application. 1.3 Accuracy of technical documentation These operating instructions were created with the greatest care. We accept no liability for accuracy and completeness of the data, images and drawings. Subject to change. Operating instructions PT-RF V1.2 page 3 of 27

1.4 High-pressure applications The overload pressure should not be exceeded when selecting the pressure transmitters. The pressure transmitter can be damaged if the overload pressure is exceeded (depending on length/frequency and height of the pressure spike). In case of air inclusions, the diesel effect can create pressure spikes which far exceed the overload pressure. The nominal pressure of the pressure transmitter should therefore be greater than the nominal pressure in the system to be measured. Operating instructions PT-RF V1.2 page 4 of 27

1.5 Service/repairs Please contact your sales office for repair of the reading devices. 1.6 Information about disposal Recycling in line with WEEE Buying our product means that you have the opportunity to return the device to the sales office after the end of its life cycle. The WEEE (EU Directive 2002/96/EC) governs the return and recycling of old electrical appliances. In the B2B (business to business) field, as of 13 August 2005 manufacturers of electrical appliances are obliged to take back and recycle any electrical appliances sold after this date free of charge. Electrical appliances must therefore not be introduced into the normal waste streams. Electrical appliances have to be recycled and disposed of separately. All appliances which are affected by this guidelines are marked with this logo. What can we do for you? We therefore want to offer you a cost-neutral option for returning your old appliance to us. We will then recycle and dispose of your appliance in line with current legislation. What do you need to do? When your appliance has reached the end of its lifetime, simply send it to your sales office using a courier service (in the box). We will then take on any recycling and disposal measures. This means you have no costs and no troubles. Any questions? Please contact the sales office if you have any further questions. Operating instructions PT-RF V1.2 page 5 of 27

Information about battery disposal In the EU, the disposal of batteries is subject to the Battery Directive 2006/66/EU, in Germany to the Battery Act (BattG) dated 25 June 2009 and internationally to the respective national legislation. Batteries must never be placed in household waste. Operating instructions PT-RF V1.2 page 6 of 27

2 Scope of Supply - reading device Reader-PT-RF - power supply unit 230/110 V 1.2 A - USB 2.0 cable - software on CD - Quick Guide Operating instructions PT-RF V1.2 page 7 of 27

3 Reading device Reader-PT-RF antenna display measuring key/function key on/off button micro USB connection Status display (LED) Operating instructions PT-RF V1.2 page 8 of 27

4 Pressure transmitter PT-RF Process connection G1/4 (B04) Process connection 1/4NPT (N04) 4.1 Installing the pressure transmitters The pressure transmitter has a G1/4 or 1/4NPT process connection, depending on the version. The pressure transmitter has to be installed in line with these connections. Connection using STAUFF Test SDA adaptors can be fitted for direct connection with test couplings. It should be ensured that there is sufficient space above the plastic cap to allow reading out the values with the Reader-PT-RF reading device. The ambient temperature must not exceed + 85 C / + 185 F. Operating instructions PT-RF V1.2 page 9 of 27

5 Carrying out a measurement 5.1 Preparing a measurement Start the reading device before carrying out a measurement. To do this, press the key. The reading device will start with the start screen which displays the charging state and the available free memory. charging status charging state memory used date time Set time and date before using the reading device. This cannot be carried out on the actual reading device but has to be done through a connection to a PC. The PT-RF-SOFT software allows setting the time and deleting the memory there. It can also be set whether pressure values should be displayed in bar and C or in psi and F. Operating instructions PT-RF V1.2 page 10 of 27

Now hold the antenna in front of the pressure transmitter as shown in the read-out image below. To record a measuring value, the antenna has to remain within the measuring area during the measuring process. PC connection function box illuminated display reading device antenna cap housing SW24 measuring range distance: max. 1.5 cm within the measuring range indicated pressure transmitter (directly mounted) system side Operating instructions PT-RF V1.2 page 11 of 27

5.2 Individual measurement Now carry out a measurement by pressing the key once briefly. The measured value will appear on the display within 0.5 s as shown below. Display after successful individual measurement Serial number Measured value range Type of measurement Current pressure value Sequential number/id Current temperature value The measured value is stored in the memory of the reading device together with temperature, ID, serial number and pressure zones. (Conversion bar <-> psi / C <-> F is done by the software) If no connection to the pressure transmitter was established, an error message will appear on the screen. Ensure that the reading device is within the reception area and then try again. Operating instructions PT-RF V1.2 page 12 of 27

5.3 Continuous measurement To carry out a continuous measurement, hold the reading device in front of the pressure transmitter as for an individual measurement. Press and hold the key to carry out a continuous measurement. Display during continuous measurement Serial number Measurement range end value Type of measurement Current pressure value Number of measured values Sequential number/id Current temperature value During the measurement, the continuous measurement symbol will appear in the upper right corner and the number of measurements will be shown below the pressure value. Measurement results are stored in the memory with a resolution between 250 ms and 400 ms. The resolution depends on the orientation of the antenna towards the pressure transmitter and on the ambient conditions of the measurement. Operating instructions PT-RF V1.2 page 13 of 27

Connected or No Signal will be displayed above the measured pressure value. If No Signal or No Reading Error Log is displayed, immediately get closer to the measuring point again to continue the measurement. If no valid measuring value is received for 6 seconds, the continuous measurement will be stopped and an error message will be displayed on the screen. The measurement data up until the error message are stored in the memory. Display after successful continuous measurement Serial number Measured value range Type of measurement Last pressure value Avg. pressure value Number of measured Sequential number/id Avg. temperature value Avg. MINI/MAX pressure values Releasing the key ends the measurement and displays the result on a screen. Last measured value, mean value, MIN/MAX pressure value and mean temperature are shown on the display. (Conversion bar <-> psi / C <-> F is done by the software) All individual measurements and the measuring summary are stored in the internal memory. Operating instructions PT-RF V1.2 page 14 of 27

6 Functions 6.1 Storage battery The charging state of the power supply is indicated on the start screen. A fully charged battery will be represented by a filled symbol. This state will allow approx. 6 hours of measuring or 1.800 measurement data sets. If the battery is nearly empty, all segments of the symbol will disappear and a warning message will be displayed. In this case the reading device has to be charged. To do this, connect the USB charger set supplied to the device. If you continue to use the reading device despite the warning, the device will automatically turn off and give out another warning message. The device has to be charged immediately to prevent damage to the storage battery. 6.2 Energy saving function To preserve the charging state of the battery, the energy saving function automatically turns off the reading device after 30 seconds of no interaction. If the reading device is supplied via USB, it will not be turned off automatically and the device will remain active. Operating instructions PT-RF V1.2 page 15 of 27

6.3 Status indicator (LED) The status indicator (LED) is located next to the USB port on the reading device and has different functions. If the reading device is connected to the charger or a PC via a USB cable, the LED lights up red to indicate charging of the lithium ion battery. If it lights up green, the storage battery is fully charged and the device can be disconnected from the PC or charger. In addition to this charging indicator, the LED signals successful or failed measurements as sometimes a direct view of the display is not possible. If the LED flashes green after a measurement, the measurement was successful. If it flashes red, an error has occurred. Operating instructions PT-RF V1.2 page 16 of 27

6.4 Measurement process A measurement process generally takes 250 ms. This requires the reading device to be at the optimum distance to the pressure transmitter. If the position is less than ideal this can result in a longer loading time or transmission time of the reading device. This can then take up to 400 ms. The following graph shows an approximation of the measurement protocol. Loading and initialising pressure transmitter Transfer and processing of measurement data Measurement Zone 250 ms - 400 ms Operating instructions PT-RF V1.2 page 17 of 27

7 Software The software stored on the original STAUFF data medium allows the transfer of measurement values from the reading device to the PC. It allows easy display and processing of the measurement values as well as data export to Microsoft Excel. 7.1 Installation To install the PT-RF-Soft software, insert the data medium into your drive or download from www.stauff.com Run the installation file and follow the instructions. The installation process will install the software and the corresponding USB drivers. Please connect the Reader to the PC before starting the installation. This ensures that the drivers are installed correctly. Operating instructions PT-RF V1.2 page 18 of 27

7.2 The Interface If the installation was successful, the software can be started from the Start menu on the PC. After starting the user interface appears as shown below. On the left side of the interface, the different functions of the software can be run on different buttons (download measurement data, storing, exporting, settings...). On the right side you will find the list of data that has been downloaded or opened. Above this list, the filters can be found. Operating instructions PT-RF V1.2 page 19 of 27

Below the list of measurements you find the measurement graph, which always shows the actual displayed measurements in the list. 7.3 Connecting a reader To connect a reader to the software simply use the supplied USB cable and connect the reader to the PC. After a couple of seconds the Status field in the upper left corner will change from red to green and you are ready to use the Download function. During the first connection it is possible that finding the reader can take a half a minute. 7.4 The measurement list This list displays all measurements that have been downloaded or opened. The following information is stored with each measurement. Serial number: Date: Time: ID: Serial number or custom naming of transmitter Date of measurement Time of measurement Measurement ID which is assigned and shown during taking the measurement. Operating instructions PT-RF V1.2 page 20 of 27

Type of measurement: This shows the type of measurement that has been used. If the measurement was a single measurement it is shown Single. If the measurement was a continuous measurement it is shown Continuous and the result of measurement type is shown as Result continuous. Seq. No.: Pressure Act.*: Pressure min.*: Pressure max.*: Temp*: Initial S/N: In the case of a continuous measurement, this number is used as an indicator of the number of measurement. During a single measurement, this value remains at 1. Pressure value (only for single or continuous) (When a continuous type of measurement is taken, the Result Cont. will show the average of all continuous readings) Minimal pressure value when doing a continuous measurement. Maximal pressure value when doing a continuous measurement Temperature value. The serial number is displayed here again. If you assigned a name to a sensor, the serial number can be recalled from here. *The units will be shown in separate columns Operating instructions PT-RF V1.2 page 21 of 27

7.5 Function-Buttons Download measurements By pressing this button, all measurement contained in the reader will be downloaded and displayed in the data list. All measurements remain on the Reader. They remain there until the memory is full or the erase memory function was used. Save all By pressing this button, all measurement are stored. This file is stored in your computer as a.pt-rfs file format and can be opened with the PT-RF SOFT. Save selected By pressing this button, all measurements that are shown on the list are stored and saved as a.pt-rfs file format. Export as csv By pressing this button, all measurements that are shown on the list are saved as a csv file. You can open this file with excel or any spreadsheet program for further processing. When you open the measurement data in Excel, it may happen that due to Excel Auto-formatting the measurement time is not displayed correctly. To correct this you need to set the "cell format to category "custom" and use the type "hh: mm: ss,000". Operating instructions PT-RF V1.2 page 22 of 27

Open measurements By pressing this button, data files with the file name.pt-rfs can be opened into the list again. Import measurements With this function you can import attach old.pt-rfs data lists which can be added to below the data currently being displayed. This data can then be compared and saved. 7.6 Set-Buttons BAR <-> PSI The reader can receive data in either Bar pr PSI. This setting can be changed using this function. If a reader is set to PSI, the temperature is always stored in F. If reader is set to bar, temperature will be in C. The successful setting is confirmed with a feedback. Set Time This function set the current time of the PC to the reader. Erase Memory By using this function, the memory of the reader is emptied. Restoring it again is not possible. Operating instructions PT-RF V1.2 page 23 of 27

Sensor Naming When using this button a sub menu will open. In this menu it is possible to attach a name to a serial number. This function enables the naming of a transmitter unique to a system of piece or equipment. After clicking Add and Apply in this menu the current list will be updated with the name used. Time Format 12h By clicking the 12h option in the settings menu the time format of the results are changed from 24h mode to 12h mode. This also changes the date format to US format. Above the measuring table you find the information box, which informs you about the setting. 7.7 Filter Options Above the measurement data list are three filter options can be found, Serial No of sensor, Time from and Time until. Here the data can be filtered by the sensor serial number or the time of the measurement. "Reset Filter" will reset all filters. Operating instructions PT-RF V1.2 page 24 of 27

8 Maintenance/cleaning/repairs Caution Caution Switch off the reading device before cleaning and disconnect it from the power supply. Caution Caution Aggressive cleaning agents such as solvents, petrol or similar hydrocarbons must not be used. These substances could damage the housing or the display. If the housing is dirty, wipe it with a soft, slightly damp cloth. Use a mild household cleaner for stronger contaminations. 8.1 Repairs and Service Please contact your sales office for assistance. Operating instructions PT-RF V1.2 page 25 of 27

9 Technical Data 9.1 Pressure transmitter Materials housing: stainless steel 1.4305 seal (B04): FPM (Viton ) cap: polyamide (glass fibre-reinforced) dimensions: 59 x 26 mm / 2.31 x 1.02 in weight: 80 g /.18 lbs Temperature range media temp.: -30 C... +135 C / -22 F... +275 F ambient temp.: -30 C... +85 C / -22 F... +185 F storage temp.: -50 C +100 C / -58 F +212 F Response time typ. 250 ms; max. 400 ms Long-term stability: acc. to IEC EN 60770-1 max. ± 0.25 % FS* /a Vibration load: in line with IEC 60068-2-6 (20 g) Impact load: in line with IEC 60068-2-27 (30 g) 11 ms Temperature max. ± 0.2 % FS* /10K (test condition 25 C; 45 % v. F.) behaviour Protection rating IP69: Dust-tight and protected against high pressure and steam jet cleaning. Operating instructions PT-RF V1.2 page 26 of 27

9.2 Reading device Materials ABS plastic housing dimensions: 76 x 35 x 240 mm / 3.0 x 1.38 x 9.45 in weight: 220 g /.49 lbs Measurement/display pressure: in bar and PSI temperature: in C and F display: graphic, LED backlit visible area: 55 x 46 mm / 2.17 x 1.81 in resolution: 128 x 64 Pixel Storage battery: lithium ion (3.7 V DC / 900 mah) Operating time approx. 6 h (approx. 1800 individual measurements) Temperature range: ambient temp.: -20 C... +70 C / -4 F... +158 F storage temp.: -25 C... +60 C / -13 F... +140 F Sampling rate typ. 250 ms; max. 400 ms Interface Micro-USB EMC compatibility: EN 61326-1:2013 EN 300330 Protection rating protection rating IP65: Dust-tight and protected against water jets Operating instructions PT-RF V1.2 page 27 of 27