Air Conditioning Technical Data FBA-A > FBA35A2VEB > FBA50A2VEB > FBA60A2VEB > FBA71A2VEB > FBA100A2VEB > FBA125A2VEB > FBA140A2VEB

Similar documents
Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB

Air Conditioning Technical Data FHA-A > FHA35AVEB > FHA50AVEB > FHA60AVEB > FHA71AVEB > FHA100AVEB > FHA125AVEB > FHA140AVEB

Air Conditioning Technical Data FUA-A > FUA71AVEB > FUA100AVEB > FUA125AVEB

CTXA-AS/AT/AW, FTXA-AS/AT/AW

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C

Split. Air Conditioning Technical Data FTXM-M > FTXM20M2V1B > FTXM25M2V1B > FTXM35M2V1B > FTXM42M2V1B > FTXM50M2V1B > FTXM60M2V1B

Hello Madoka. The beauty of simplicity

Slim duct (AMTTTFNLDEH ) Indoor units

Allows detailed and easy monitoring and operation of VRV systems (maximum 2 x 64 groups / indoor units)

EEDEN technical data. air conditioning systems. Individual Control Systems

Hello Madoka. The beauty of simplicity

MULTI SPLIT 074 PRODUCT LINEUP & 3-4 ROOMS MULTI ROOMS MULTI 080 INDOOR UNITS FOR MULTI SPLIT SPECIFICATIONS 082 MULTI COMBINATION

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH***

Allows detailed and easy monitoring and operation of VRV systems (maximum 2 x 64 groups / indoor units)

DESIGN & TECHNICAL MANUAL

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

Ceiling Concealed Split System C Series

U-Match Series DC Inverter Service Manual PRODUCT

WIRED REMOTE CONTROLLER

NETWORK SOLUTIONS. The ideal solution for control and management of maximum 1,024 VRV indoor units

User-friendly interface

technical data air conditioning systems

VRF Technical Data Book

technical data air conditioning systems

technical data Systems Individual control systems

Daikin Airconditioning UK Ltd. Allows detailed and easy monitoring and operation of VRV Systems (maximum 2 x 64 groups / indoor units)

SINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A,

WIRED REMOTE CONTROLLER

DUCTED SPLIT SYSTEMS With Scroll compressors

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

VRF. Technical Data Book. DVM S Eco 8, 9 HP

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Liquid Cooling Package LCP Cooling Systems

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-...

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

R410A D2D_AU019E/

SINGLE Technical Data Book. SINGLE for Europe (R410A, HP)

GV-LPC MP 10x Zoom B/W Network Camera

Accessories Control systems

Net: PLN Gross: PLN

Liquid Cooling Package LCP Cooling Systems

Wireless Remote Controller Kit

Net: EUR Gross: EUR

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

Net: EUR Gross: EUR

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

Cooled incubators (ST), laboratory refrigerators

GV-LPC MP B/W Network Camera

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

GV-SD220-S (20x / 30x) Outdoor Full HD IP Speed Dome

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

VRF Control System. Judy Ouyang Technical Support Engineer

Net: EUR Gross: EUR

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

2. bizhub Remote Access Function Support List

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

GV-FE420 4MP H.264 Fisheye IP Camera

TOSHIBA AIR CONDITIONING

Network node WTT56.. A6V _en--_c Building Technologies

GV-SD220-S (20x / 30x) Outdoor Full HD IP Speed Dome

Filter Fan Unit LIGHT

SPLIT lineup preview

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Adjustable swirl diffuser PDZA TECHNICAL DATA

kyalfa V- VDD/VDD6 General Contents

GV-BX4700-E 4MP H.265 Super Low Lux WDR Pro IR Arctic Box IP Camera

GV-FE520 5MP H.264 Fisheye IP Camera

Blue e+ chillers with the principle

Performance Certification : From Energy Efficiency To Indoor Air Quality. By: Eric Foucherot

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Daikin HVAC Controls Guide Specification

INSTALLATION MANUAL. Remote controller BRC315D7

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Net: EUR Gross: EUR

GV-FE4301 4MP H.264 WDR Fisheye IP Camera

PORTABLE VIDEO BORESCOPE. User Manual

SERVICE Manual DUCT TYPE AIR CONDITIONER. (Cool) OUTDOOR UNIT INDOOR UNIT TYPE UDH4400G DH44ZAX IDH4400A DH44ZA1(A2) ADH4400G DH44ZA1(A2)

I-Net. An intelligent approach to air conditioning management

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

ECL Comfort 296 controller and Remote Control Unit ECA 30 / 31

Reliability and extended operation

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

Room controller STRA-17

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

8 Parts and diagrams. Chapter contents. Ordering parts and supplies. Accessories. Covers. Internal components. Tray 2 pickup assembly

GV-FE520 5MP H.264 Fisheye IP Camera

Semi Flush-mount Room Temperature Controllers with LCD

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

Transcription:

Air Conditioning Technical Data FBA-A > FBAA2VEB > FBAA2VEB > FBAA2VEB > FBA71A2VEB > FBA0A2VEB > FBA1A2VEB > FBA1A2VEB

Indoor Unit FBA-A TABLE OF CONTENTS FBA-A 1 Features............................................................. 2 2 Specifications....................................................... 3 Technical Specifications............................................. 3 Electrical Specifications.............................................. 4 3 Options............................................................... 5 4 Dimensional drawings............................................. 6 5 Centre of gravity.................................................... 9 6 Piping diagrams................................................... 7 Wiring diagrams................................................... 11 Wiring Diagrams - Single Phase.................................... 11 8 Sound data......................................................... 12 Sound Pressure Spectrum.......................................... 12 9 Fan characteristics................................................ 16 Installation.......................................................... 18 Installation Method.................................................. 18 Split - Sky Air FBA-A 1

Indoor Unit FBA-A 1 Features e ytc k i S nd Ue - l ra toae oic- dlan nbpo CFSSlimmest I yet most powerful medium static pressure unit on the market 1 Slimmest unit in class, only 2mm (0mm built-in height) and therefore narrow ceiling voids are no longer a challenge Discretely concealed in the ceiling: only the suction and discharge grilles are visible Low operation sound level down to dba Medium external static pressure up to 1Pa facilitates using flexible ducts of varying lengths Multi zoning kit allows multiple individually-controlled climate zones to be served by one indoor unit Unified indoor unit can be combined with R-32 and R-4A outdoor units, symplifying stock Reduced energy consumption thanks to specially developed DC fan motor Optional fresh air intake Flexible installation: air suction direction can be altered from rear to bottom suction and choice between free use or connection to optional suction grilles Standard built-in drain pump with 6mm lift increases flexibility and installation speed Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-4A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge Possibility to change ESP via wired remote control allows optimisation of the supply air volume Infrastructure cooling Air filter Multi zoning Inverter Home leave operation Weekly timer Infrared remote Wired remote control control Multi model application 2 Split - Sky Air FBA-A Fan only Auto coolingheating changeover Centralised control Auto-restart Whisper quiet Fan speed steps Self diagnosis Drain pump kit Dry programme Twin/triple/ double twin application

2 Specifications Indoor Unit FBA-A 2-1 Technical Specifications FBAA FBAA FBAA FBA71A FBA0A FBA1A FBA1A Power input - Hz Cooling Nom. kw - 0.23 Heating Nom. kw - 0.23 Casing Colour Not painted (galvanised) Material Galvanised steel plate Dimensions Unit Height/Width/ mm 2/0/0 2/1,000/0 2/1,0/0 Depth Packed unit Height/Width/ mm 8/0/295 8/1,0/295 8/1,0/295 Depth Weight Unit kg 28.0.0 46.0 Packed unit kg.5 38.0 49.0 Heat exchanger Fin Type Cross fin coil (Multi slit fins with hydrophilic treatment and Ø5Hi-XA tubes) Air filter Type Resin net Fan Model QD16A1CM/QD16A1DM Type Sirocco fan Quantity 1 2 3 Air flow rate Cooling High m³/min.0 18.0 29.0 34.0 Mediu m³/min 12.5 (1).0 (1) 26.0 (1) 29.0 (1) m Low m³/min.5 12.5 23.0 23.5 Heating High m³/min.0 18.0 29.0 34.0 Mediu m³/min 12.5 (1).0 (1) 26.0 (1) 29.0 (1) m Low m³/min.5 12.5 23.0 23.5 External static High Pa 1 pressure Nom. Pa Fan motor Quantity 1 Model Brushless DC motor Speed Steps 3 Output Rated W 1 2 0 Sound power level Cooling dba 56 58 62 Heating dba - Sound pressure level Cooling High/Medium/ Low Heating High/Medium/ Low Standard Accessories : Operation manual; Quantity : 1; Standard Accessories : Installation manual; Quantity : 1; Standard Accessories : Drain hose; Quantity : 1; Standard Accessories : Metal clamp for drain hose; Quantity : 1; Standard Accessories : Washer for hanger bracket; Quantity : 8; Standard Accessories : Screws; Quantity : ; Standard Accessories : Insulation for fitting; Quantity : 2; Standard Accessories : Sealing pads; Quantity : 5; Standard Accessories : Clamps; Quantity : 4; dba.0/32.0 (1)/29.0.0/28.0 (1)/.0 34.0/32.0 (1)/.0 dba 37.0/34.0/29.0 31.0/28.0/.0 36.0/33.0/.0 Control systems Infrared remote control BRC4C / BRC4C66 Wired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7 Refrigerant Type R-32 / R-4A Piping connections Sound absorbing insulation Butyl Rubber Liquid Type/OD mm Flare connection/6, Flare connection/9,52 Gas Type/OD mm Flare Flare connection/12. Flare connection/. connection/ 9.52 Drain VP (I.D. /O.D. 26) Heat insulation Foamed polystyrene / Foamed polyethylene Drain-up height mm 6 37.0/.0 (1)/32.0 38.0/.0/32.0 3 2 Split - Sky Air FBA-A 3

2 Specifications Indoor Unit FBA-A 2-2 Electrical Specifications FBAA FBAA FBAA FBA71A FBA0A FBA1A FBA1A Power supply Phase 1~ Frequency Hz / Voltage V 2-2/2 2 Notes (1) See separate drawing for electrical data The sound power level is an absolute value indicating the power which a sound source generates. 4 Split - Sky Air FBA-A

Indoor Unit FBA-A 3 Options 3-1 Options FBA-A SA 3 Discharge Description Option kit FBAA FBAA FBAA FBA71A FBA0A FBA1A FBA1A Air discharge adaptor for round ducts KDAPA56A KDAPA71A KDAPA1A X X X 3 SA Operation control Description Option kit FBAA FBAA FBAA FBA71A FBA0A FBA1A FBA1A Wired remote control Central remote control Unified ON/OFF controller Intelligent touch controller Schedule timer Adaptor for wiring (interlock for fresh air intake fan) Wiring adaptor for electrical appendices Wiring adaptor for electrical appendices Optional PCB for external electric heaters, humidifiers and/or hour meters Wireless remote control H/P Wireless remote control C/O Simplified remote control for hotel use Remote control for hotel use Remote sensor Electrical box with earth terminal Installation box for adaptor PCB Digital input adaptor itouch Manager BRC1D528 BRC1E53A7 X(*7) X(*7) X(*7) BRC1E53B7 X(*8) X(*8) X(*8) BRC1E53C7 X(*9,) X(*9,) X(*9,) DCS2CA51 DCS1BA51 DCS1C51 DST1BA51 KRP1B54 KRP4A52 X(*4) X(*4) X(*4) KRP4A51 X(*2,4) X(*2,4) X(*2,4) EKRP1B2A X(*1,2) X(*1,2) X(*1,2) BRC4C BRC4C66 BRC2E52C7 X(*6,) X(*6,) X(*6,) BRC3E52C7 X(*6,) X(*6,) X(*6,) KRCS01-4B KJB411A KRP1BA1 KRP1B1 BRP7A51 X(*3,5) X(*3,5) X(*3,5) DCM1A51 (*1) (*2) (*3) (*4) (*5) (*6) (*7) (*8) (*9) (*) Electric heaters and humidifiers are field-supplied. Do not install them inside the equipment (refer to installation manual EKRP1B2A ). When installing electric heaters, an optional PCB for external electric heaters (EKRP1B2) is required for each indoor unit. These options require mounting plate KRP4A96. Maximally 2 optional PCBs can be mounted. This option needs to be installed together with installation box KRP1B1/KRP1BA1. Only possible in combination with remote control BRC2/3E52C7, BRC1E53A/B/C7. Included languages are: Language pack 1: English, German, French, Dutch, Spanish, Italian, and Portuguese. With PC cable EKPCCAB3 in combination with the Updater PC software, you can additionally change the language to: Language pack 2: English, Bulgarian, Croatian, Czech, Hungarian, Romanian, and Slovenian. Language pack 3: English, Greek, Polish, Russian, Serbian, Slovak, and Turkish. Included languages are: English, German, French, Italian, Spanish, Portuguese, and Dutch. Included languages are: English, Czech, Croatian, Hungarian, Slovenian, Romanian, and Bulgarian. Included languages are: English, Russian, Greek, Turkish, Polish, Albanian, and Slovak. Language pack 3 of controller BRCE1E53C7 is different from that of controller BRC2/3E52C7. 3D6133 Split - Sky Air FBA-A 5

Indoor Unit FBA-A 4 Dimensional drawings 4-1 Dimensional Drawings 4 6 Split - Sky Air FBA-A

Indoor Unit FBA-A 4 Dimensional drawings 4-1 Dimensional Drawings 3 4 Split - Sky Air FBA-A 7

Indoor Unit FBA-A 4 Dimensional drawings 4-1 Dimensional Drawings 4 8 Split - Sky Air FBA-A

5 Centre of gravity 5-1 Centre of Gravity Indoor Unit FBA-A 3 5 Split - Sky Air FBA-A 9

6 Piping diagrams 6-1 Piping Diagrams Indoor Unit FBA-A 6 Split - Sky Air FBA-A

Indoor Unit FBA-A 7 Wiring diagrams 7-1 Wiring Diagrams - Single Phase 3 7 Split - Sky Air FBA-A 11

Indoor Unit FBA-A 8 Sound data 8-1 Sound Pressure Spectrum FBAA 8 NR5 NR NR NR Cooling mode NR NR NR NR NR NR NR NR NR NR NR NR 63 1 2 0 00 00 00 00 dba Heating mode NR NR NR NR NR NR NR NR NR NR NR NR NR5 NR NR NR 63 1 2 0 00 00 00 00 dba Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 32 29 dba 37 34 29 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard Unit 2. Background noise already taken into account. Discharge Suction 3. Operating noise varies depending on operation and ambient conditions. 4. The operation noise measuring method is in accordance with JISC9612. Middle 5. Measuring location: anechoic chamber 3D1166 FBAA NR5 NR NR NR Cooling mode NR NR NR NR NR NR NR NR NR NR NR NR 63 1 2 0 00 00 00 00 dba Heating mode NR NR NR NR NR NR NR NR NR NR NR NR NR5 NR NR NR 63 1 2 0 00 00 00 00 dba Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 32 29 dba 37 34 29 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard Unit 2. Background noise already taken into account. Discharge Suction 3. Operating noise varies depending on operation and ambient conditions. 4. The operation noise measuring method is in accordance with JISC9612. Middle 5. Measuring location: anechoic chamber 3D1167 12 Split - Sky Air FBA-A

Indoor Unit FBA-A 8 Sound data 8-1 Sound Pressure Spectrum FBAA 3 NR5 NR NR NR Cooling mode NR NR NR NR NR NR NR NR NR NR NR NR 63 1 2 0 00 00 00 00 dba Heating mode NR NR NR NR NR NR NR NR NR NR NR NR NR5 NR NR NR 63 1 2 0 00 00 00 00 dba 8 Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 28 dba 31 28 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard Unit 2. Background noise already taken into account. Discharge Suction 3. Operating noise varies depending on operation and ambient conditions. 4. The operation noise measuring method is in accordance with JISC9612. Middle 5. Measuring location: anechoic chamber 3D1168 FBA71A NR5 NR NR NR Cooling mode NR NR NR NR NR NR NR NR NR NR NR NR 63 1 2 0 00 00 00 00 dba Heating mode NR NR NR NR NR NR NR NR NR NR NR NR NR5 NR NR NR 63 1 2 0 00 00 00 00 dba Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 28 dba 31 28 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard Unit 2. Background noise already taken into account. Discharge Suction 3. Operating noise varies depending on operation and ambient conditions. 4. The operation noise measuring method is in accordance with JISC9612. Middle 5. Measuring location: anechoic chamber 3D1169 Split - Sky Air FBA-A 13

Indoor Unit FBA-A 8 Sound data 8-1 Sound Pressure Spectrum FBA0A 8 NR5 NR NR NR Cooling mode NR NR NR NR NR NR NR NR NR NR NR NR 63 1 2 0 00 00 00 00 dba Heating mode NR NR NR NR NR NR NR NR NR NR NR NR NR5 NR NR NR 63 1 2 0 00 00 00 00 dba Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 34 32 dba 36 33 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard Unit 2. Background noise already taken into account. Discharge Suction 3. Operating noise varies depending on operation and ambient conditions. 4. The operation noise measuring method is in accordance with JISC9612. Middle 5. Measuring location: anechoic chamber 3D11 FBA1A NR5 NR NR NR Cooling mode NR NR NR NR NR NR NR NR NR NR NR NR 63 1 2 0 00 00 00 00 dba Heating mode NR NR NR NR NR NR NR NR NR NR NR NR NR5 NR NR NR 63 1 2 0 00 00 00 00 dba Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 37 32 dba 38 32 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard Unit 2. Background noise already taken into account. Discharge Suction 3. Operating noise varies depending on operation and ambient conditions. 4. The operation noise measuring method is in accordance with JISC9612. Middle 5. Measuring location: anechoic chamber 3D1171 14 Split - Sky Air FBA-A

Indoor Unit FBA-A 8 Sound data 8-1 Sound Pressure Spectrum FBA1A 3 NR5 NR NR NR Cooling mode NR NR NR NR NR NR NR NR NR NR NR NR 63 1 2 0 00 00 00 00 dba Heating mode NR NR NR NR NR NR NR NR NR NR NR NR NR5 NR NR NR 63 1 2 0 00 00 00 00 dba 8 Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 37 32 dba 38 32 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard Unit 2. Background noise already taken into account. Discharge Suction 3. Operating noise varies depending on operation and ambient conditions. 4. The operation noise measuring method is in accordance with JISC9612. Middle 5. Measuring location: anechoic chamber 3D1172 Split - Sky Air FBA-A

Indoor Unit FBA-A 9 Fan characteristics 9-1 Fan Characteristics 9 16 Split - Sky Air FBA-A

Indoor Unit FBA-A 9 Fan characteristics 9-1 Fan Characteristics 3 9 Split - Sky Air FBA-A 17

Installation - 1 Installation Method Indoor Unit FBA-A 18 Split - Sky Air FBA-A

Daikin Europe N.V. Naamloze Vennootschap - Zandvoordestraat 0, B- Oostende - Belgium - www.daikin.eu - BE 0412 1 336 - RPR Oostende EEDEN17 05/17 Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Air handling units (AHU), Fan coil units (FCU) and variable refrigerant flow systems (VRF) Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.