Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Similar documents
Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

UV Power Flood. User Manual. Order code: EQLED029

Blitzer Strobe. User Manual. Order code: EQLED366

Crossfire. User Manual. Order code: EQLED061

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Performer 18 RGBWA MKII

Microbar COB System. User Manual. Order code: EQLED137

Slimline CW & WW Series

UV Spectra Batten 12 x 5W UV LEDs

CDP 405 Digital Dimmer Pack

Vector Beam White. User Manual. Order code: LEDJ265

RGB Power Batten. User Manual. Order code: EQLED032

Fusion Saber. User Manual. Order code: EQLED070

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Gobo Projector XP 80W

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

ZF LED Zoom Fresnel. User Manual

PF LED Profile. User Manual

CS2 DMX Distribution Splitter

IMPACT Order code: EQLED79

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

DMX LED Starcloth Systems

MICRON DJ Booth Tri-colour Starcloth

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

Microbar Multi System

w w w. p r o l i g h t. c o. u k STAGE PAR 64

Order code: EQLED60 USER MANUAL

LIGHT BRICK - 12 X 3W TRI-COLOUR

MICRON DJ Booth System with Overhead Kit & CW Starcloth

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Saturn Spot. User Manual. Order code: EQLED023

EasiLED 4 DMX Controller

Vortex. User Manual. Order code: EQLED073

Hypnos. User Manual. Order code: EQLED372

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

Colour Burst Order code: LEDJ01 USER MANUAL

order code: EQLED40 user manual

Endura 1Q120 RGBW COB Exterior Fixture

Intense 9P10 RGBWA LED Slim Par

Intense 9HEX10 LED Slim Par

Order code: EQLED53 User manual

Professional DMX Stage Backdrop

Flexoled FTP3HP RGB LED DMX Driver

FTP1 Single Channel LED DMX Driver

Slimline 12Q5 Series

Fresco 24 RGBW. Exterior Fixture User Manual. Order code: LEDJ267

50W/100W LED Alu. User Manual. Code: ELUM041-50W - (5600K) Code: ELUM041A - 100W (5600K) Code: ELUM041C - 50W - (3200K) Code: ELUM041D - 100W (3200K)

Starlit Dance Floor. User Manual

User Instructions. American DJ

TRANSCENSION Show Control

order code: EQLA04 user manual

CPA 40 Two Channel Amplifier

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

Heavy Duty DMX Mirror Ball Rotator with Safety Eye

SP-1500 DMX MK II Strobe

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

LED PAR56 Order Code: P56-151

Octostrip ORDERCODE 42220

Party Dimmer IEC ORDERCODE 50324

Cobra Dimmer Master DMX Controller User Manual

BGS 20T 100V/8Ω Background Music Loudspeakers

LED W RGBA User Manual

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

Multidim ORDERCODE 50391

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

LED DANCING FLOOR User Manual

Power LED Beam 56 Narrow

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

User Instructions. American DJ Charter Street Los Angeles Ca

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

LED Par 64 Short DMX ORDERCODE 42431

Light Brick ORDERCODE 50370

TourPro RGBAW Stagebar USER MANUAL

FLEX BEAM V8. User Manual Please read the instruction carefully before use

COLOR PAR 56 COLOR PAR 64. User Manual Please read the instructions carefully before use. Широкий ассортимент оборудования ACME на

MATRIX LED LED User Manual Please read the instructions carefully before use

User Instructions. Elation Professional 4295 Charter Street Los Angeles CA

CP 64 BD15 CP 64 PD15

1 Channel Strobe Controller ORDERCODE 40226

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

xbrick Full-Colour 16 3W LED floodlight user manual

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

DM-X Channel DMX Controller. Item ref: UK User Manual. Version 2.0

N-E Color Par 64 USER MANUAL

PAR56 10MM UV LED PAR. user manual

LED Dancefloor ORDERCODE 42300

LED Pixel Rail Drive 640 controller. user manual

D-Pack 6 Classic ORDERCODE 50315

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

Check that the unit has not been damaged during transport

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

StagePar COB TRI 4 CKU

imove 50SR LED-MS50A User Guide Professional Entertainment Technology

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

Transcription:

Party Par User Manual Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make sure that there is no damage caused during transportation. Should there be any damage, consult your dealer and do not use the equipment. To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual. Please note that damages caused by user modifications to this equipment are not subject to warranty. CAUTION! KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS CAUTION! TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!! IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment. Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution! Never remove warning or informative labels from the unit. Do not open the equipment and do not modify the unit. Do not connect this equipment to a dimmer pack. Do not switch the equipment on and off in short intervals, as this will reduce the system s life. Only use the equipment indoors. Do not expose to flammable sources, liquids or gases. Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable. Make sure that the available voltage is between 100~240V, 50/60Hz. Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically. If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again. If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature. If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service. Only use fuses of same type and rating. Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. WARRANTY: One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. www.prolight.co.uk Party Par User Manual 2

Product overview & technical specifications Party Par Featuring 177 x 5mm RGB LEDs the Equinox Party Par outputs spots of colour that produce stunning shows for performances of all sizes. The units operate in several modes, including, DMX, and stand alone. 177 x 5mm LEDs (R: 60, G: 61, B: 56) Beam angle: 30 DMX channels: 6 Auto, sound active, RGB and master/slave modes 0-100% dimming Captive power connection 3-pin XLR in/out socket Fan cooled Supplied with hanging bracket Specifications Power consumption Power supply Dimensions Weight Order code Party Par 20W 120~240V, 50/60Hz 195 x 205 x 240mm 1.1kg EQLED015 - Black housing EQLED015B - Polished housing 01 PUSH 205mm 195mm 240mm 02 04 05 DMX OUT 01 - Captive power connection 02 - DMX out 03 - DMX in 04 - Status indicator 05 - Dipswitches 06 - Sound sensitivity adjustment knob STATUS INDICATOR www.prolight.co.uk 100~240V, 50/60Hz DMX IN In the box: 1 x fixture, 1 x power cable, hanging bracket & 1 x user manual 03 06 www.prolight.co.uk Party Par User Manual 3

Operating instructions DMX channel selection: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show. In this mode you will be able to control each individual trait of the fixture and each fixture independently. To access the DMX channel mode plug in the fixture via the XLR connections to a DMX controller. Set your desired DMX address following the set-up specifications that come with your DMX controller. 6 channel mode: Channel Value Function 1 0-255 Red (0: low brightness, 255: high brightness) 2 0-255 Green (0: low brightness, 255: high brightness) 3 0-255 Blue (0: low brightness, 255: high brightness) 4 0-7 Blackout 8-255 Colour macro 5 0-15 Blackout 16-255 Strobe 0-31 Blackout 32-63 Dimming (32: dim, 63: bright) 64-95 Dimming (64: bright, 96: dim) 6 96-127 Dimming (96: dim, 112: bright, 127: dim) 128-159 Colour mixing 160-191 3 Colour change 192-223 7 Colour change 224-255 Sound active (sensitivity adjustment knob) Channel 1, 2, and 3 will not work when channel 4 is being used. When the units are daisy chained together in DMX mode, channel 1, 2 and 3 must be OFF for units to sync together when using channel 4. When the value of channel 6 is between 32 and 127, you must be using either channel 1, 2 or 3, or all three combined. When using channel 6, channel 5 will control the speed of the colour changing. www.prolight.co.uk Party Par User Manual 4

Operating instructions Sound active mode: To access this mode plug the fixture in and put dipswitch #10 in the ON position. The fixture will now react to sound. To exit this mode put the dipswitch in the OFF position. Auto mode: To access this mode plug the fixture in and put dipswitch #9 and 10 in the ON position. The fixture will now chase through the colours. To adjust the speed put the dipswitches #1 to 7 in the ON position (1 being the slowest, 7 being the fastest). To exit this mode put the dipswitches in the OFF position. RGB mode: To access this mode plug the fixture in and put dipswitch #8, 9 and 10 in the ON position. Dipswitch #1 placed in the ON position will project red at 25% intensity, whilst dipswitch #2 will project at 50% intensity. Combining both dipswitches #1 and 2 will project red at 100% intensity. Dipswitch #3 placed in the ON position will project green at 25% intensity, whilst dipswitch #4 will project at 50% intensity. Combining both dipswitches #3 and 4 will project green at 100% intensity. Dipswitch #5 placed in the ON position will project blue at 25% intensity, whilst dipswitch #7 will project at 50% intensity. Combining both dipswitches #5 and 6 will project blue at 100% intensity. To exit this mode put the dipswitches in the OFF position. Master/slave mode: For master/slave operation, set the first fixture (master) into sound, auto or RGB mode. Now set the remaining fixtures into slave mode by setting dipswitch 1 to the ON position and all other dipswitches to the OFF position. To exit this mode put the dipswitches in the OFF position. www.prolight.co.uk Party Par User Manual 5

DMX setup Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture requires a start address from 1-511. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107. DMX 512: DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures (most controllers only have a data out terminal). DMX linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain. DATA cable (DMX cable) requirements (for DMX operation): This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output, see image below. Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers. Please quote: CABL10 2m CABL11 5m CABL12 10m Note: DMX cable must be daisy chained and cannot be split. www.prolight.co.uk Party Par User Manual 6

DMX setup Notice: Be sure to follow the diagrams below when making your own cables. Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour. Special note: Line termination: When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour. Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89) Termination reduces signal transmission problems and interference. It is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture. 5-pin XLR DMX connectors: Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion. 5-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C 3-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) 3-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) 5-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C www.prolight.co.uk Party Par User Manual 7

WEEE notice Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. www.prolight.co.uk Party Par User Manual 8