SpaceBuild Specification Worksheet GLPHASE System The GLPHASE SpaceBuilder system is ideal for mediumsized spaces that require additional options such as expansion modules for more load types, touch screens, additional sensors, and shade and AV integration. SpaceBuilder allows you to specify all the necessary features and operations for an autonomous lighting control system specifi cally designed for the needs of your space. Start by selecting the load types and accessories and fi nish by defi ning how each interface should function to control lighting levels, vacancy sensing, daylight harvesting, shades, and AV. System Components Options GLPHASE Available in 6 zones to control both forward or reverse phase dimming loads. All GLPHASE systems can be expanded to easily add more zones of lighting. Keypads Up to keypads can be added to a GLPHASE space. Refer to page for standard sequence of operations to specify the button operations and standard engravings. Occupancy Sensors Up to dual technology occupancy sensors can be added to each GLPHASE space for both occupancy and vacancy sensing. Each sensor offers coverage for spaces up to,000 square feet. Daylight Sensors Up to daylight sensors can be added to each GLPHASE space for daylight harvesting control. Openloop and closedloop options are available. Touch Screens An optional 7 color touch screen can be added to each to provide the user with full scene control, dynamic load control, and schedule adjustments. AddaZone The system can be expanded to include additional loads for switching, 00v,, or switched plug loads. AV Integration The GLPHASE system can easily integrate with AV systems by adding a serial control module. If this option is selected, Crestron will also supply prepackaged code for the AV contractor to connect the systems. Shade Integration Integrate with Crestron and other shading solutions. Control for up to local shade motors can be included with each GLPHASE system. Networking Any Crestron SpaceBuilder system can be networked to provide centralized monitoring, management, and master control. This includes direct integration with BMS and reporting, alerts, global time clock management, maintenance and automation via Crestron Fusion. GLPHASE KP KP KP KP Date: Project: 06 Crestron Electronics, Inc. WS_09 06 Page of 6
Specification Worksheet GLPHASE System GLPHASE SpaceBuilder Load Schedule Zone # Zone Description Fixture Tag Circuit # Voltage Load Type Emergency / Life Safety Dim (Y/N) Fixture Watts Quantity Total Watts Example Downlights A H 0 VAC Universal Phase Dimmed N/A Yes 00 Universal Phase Dimmed Universal Phase Dimmed Universal Phase Dimmed Universal Phase Dimmed Universal Phase Dimmed 6 Universal Phase Dimmed 7 Universal Phase Dimmed 8 Universal Phase Dimmed Add a zone Note: If over 8 zones, provide additional load schedule information. 0 VAC 77 VAC Universal Phase Dimmed 00V Wire Dimmed N/A Partial Zone Complete Zone Yes No PACKAGE KEYPADS S GLPHASE KP KP KP KP... UNIVERSAL PHASE ZONES 8...8 UNIVERSAL PHASE ZONES... UNIVERSAL PHASE ZONES 6...6 UNIVERSAL PHASE ZONES BLANK...NO KEYPADS A...KEYPAD A B...KEYPAD B C...KEYPAD C D...KEYPAD D E...KEYPAD E F... KEYPAD F G...KEYPAD G H...KEYPAD H N...KEYPAD N X...CUSTOM KEYPAD SOO Contact Crestron to add more than keypads BLANK...NO S...... S... S... S BLANK...NO S OS...INTERIOR CEILING WOS...INTERIOR WALL EOS.............EXTERIOR HOS... HIGHBAY OCC TYPE DAYLIGHT S TOUCH SCREEN SHADE QUANTITY SHADE MOTOR TYPE BLANK...VACANCY OCC... BLANK...NO S...... S... S... S BLANK...NO S LOL. OPEN LOOP DAYLIGHT SEN. LCL. CLOSED LOOP DAYLIGHT SEN. BLANK...NO TOUCH SCREEN TS...7 TOUCH SCREEN TS+...7 TS W/ BLANK...NO SHADES... SHADE... SHADES... SHADES... SHADES BLANK...NO SHADES RS...RS/CONTACT RLY... 0V RELAY...CRESTRON QMT MOTOR AV INTERFACE COLOR NETWORKING ADD A ZONE PLUG LOAD BLANK...NO AV AVNC...NONCRESTRON (RS) AVC...CRESTRON (ETHERNET) BLANK... WHITE BLK....................... BLACK ALMD...ALMOND BLANK...STANDALONE SPACE NET... NETWORKED SPACE BLANK...NONE DIMFLV...00V DIM BLANK...NONE PL... PLUG LOAD ZONE PL... PLUG LOAD ZONES PL... PLUG LOAD ZONES Example: GLPHASE AKP DKP OS LOL TS+ AVC NET PL GLPHASE KP KP KP KP Date: Project: 06 Crestron Electronics, Inc. WS_09 06 Page of 6
Cresnet Power Pack INPUT: 0077 VAC, 0/60Hz MAXIMUM LOAD: 6A PER CIRCUIT UP DOWN NET NET Y Z G Y Z G SDC UP DOWN PWR NET SETUP HI LO NET ID RELAY TX RX COM CRESTRON NET Y Z G Y Z G S G IR IO PWR NET SETUP Specification Worksheet GLPHASE System GLPHASE SpaceBuilder Schematic Riser TO GLNET OR GLDIST TO FIXTURES CRESTRON 7" TOUCH SCREEN OVERCURRENT PROTECTION 0A (MAX) BY OTHERS (QTY. ) 0 VAC ONLY BRANCH CIRCUIT GLPHASE LOAD LOAD TYPE: UNIVERSAL PHASE DIM LOAD LOAD TYPE: UNIVERSAL PHASE DIM QUANTITY: DAYLIGHT S CONNECT TO INPUTS ON KEYPADS OR S. IF INSUFFICIENT INPUTS ARE PRESENT ON THE PROJECT, GLSSIM INTERFACES WILL BE ADDED. DAYLIGHT DAYLIGHT DAYLIGHT DAYLIGHT CBDP 8 BUTTONS STATION ID: CKP LOCATION: SEE PLANS DWG. #: CBDP CBDP 8 BUTTONS STATION ID: CKP LOCATION: SEE PLANS DWG. #: CBDP CBDP 8 BUTTONS STATION ID: CKP LOCATION: SEE PLANS DWG. #: CBDP CBDP 8 BUTTONS STATION ID: CKP LOCATION: SEE PLANS DWG. #: CBDP TO LOAD: ( MAX) W+GND 0A (MAX) (TYP. SWITCH LOAD) FEED: NORMAL VOLTAGE: 077V H N CABLE TYPES: (NOT ALL TYPES ARE USED ON ALL PROJECTS) GLPHASE KP KP KP KP Date: Quantity: DIM H N FEED: 0V/77AC W + GND 0A(MAX) LOAD 0VAC (WITH PHASE CONTROL) CRESNET 00V DALI PLUG LOAD CONTROL QUANTITY: ETHERNET FEED: 0VAC (CRESNET OR #8) (00ohm CAT or BELDEN 98) Project: Space Name: SDC STATION ID: SDC LOCATION: SEE PLANS DWG. #: SDC TO DEVICES SHADE/DRAPE/SCREEN # SHADE/DRAPE/SCREEN # 06 Crestron Electronics, Inc. WS_09 06 Page of 6 CRESTRON ALL LOWVOLTAGE CABLE RUNS ARE CRESNET UNLESS OTHERWISE NOTED. GND RS TO A/V SYSTEM IO STATION ID: AV LOCATION: SEE PLANS DWG. #: IO
6 7 8 0 ON OFF BUTTON 8 CBDP PART #: Button Functionality: DEVICE: ON Turn all lights on CBDP and enable daylight CAMEO harvesting If daylight sensor BUTTON KEYPAD is not present, lights will turn on BUTTON to 00% "MODIFIED" LAYOUT Button Functionality: OFF Button Functionality: DRAWING: DIM OF Toggle to dim load up and down BUTTON CBDP MODIFIED LAYOUT & ENGRAVING DESCRIPTION: REVISION: 007 DATE: /0/0 NOTES: UPDATE AVAILABLE S OTHER S NOT RENUMBERED GLPHASE SpaceBuilder Sequence of Operations 8 BUTTON KEYPAD TYPE A Office, Restroom, Storage/Utility Room, Corridor, Basic Classroom Button Functionality: ON Turn all lights on and 6 enable daylight harvesting ON If daylight sensor is not present, lights will turn on to 00% Button Functionality: OFF OFF 9 0 KEYPAD TYPE B KEYPAD TYPE C ON OFF DIM Date: Specification Worksheet GLPHASE System Office, Conference Room, Classroom, Library Button Functionality: 6 ON 7 Turn all lights on and enable daylight harvesting If daylight sensor is not present, lights will turn on to 00% Press and hold will raise all dimmable lighting Button Functionality: OFF Press and hold will lower all dimmable lighting 9 Office, Conference Room, Classroom, Library Volvo Drive Rockleigh NJ 0767 Tel: 88877876 Fax: 076760 www.crestron.com 0 7 8 8 BUTTON BUTTON CBDP PART #: BUTTON Volvo Drive Rockleigh NJ 0767 Tel: 88877876 Fax: 076760 www.crestron.com BUTTON BUTTON PLEASE USE THESE S AS A GUIDE TO FILL OUT THE MODIFIED KEYPAD LAYOUT & Project: ENGRAVING FORMS ON THE NEXT PAGE CBDP MODIFIED LAYOUT & ENGRAVING DESCRIPTION: REVISION: 007 DATE: /0/0 NOTES: UPDATE AVAILABLE S OTHER S NOT RENUMBERED CBDP KEYP MODIFIED K GLPHASE KP KP KP KP ON SCENE SCENE SCENE ALL OFF Button Functionality: ALL ON If daylight sensor is not present, lights will turn on to 00% Button Functionality: SCENE Recalls scene settings with feedback Button Functionality: SCENE Recalls scene settings with feedback Button 7 Functionality: PLEASE USE THESE S AS A GUIDE Dim lights TO down FILL OUT THE MODIFIED KEYP NOTE THAT SEVERAL S HAVE BEEN REMOVED FROM THIS SHEET, BUT NUMBERS ARE UNCHAINED TO MAINTAIN COMPATIBILI KEYPAD TYPE D Office, Conference Room, Classroom, Library Continued on page BUTTON BUTTON BUTTON 6 8 Button Functionality: ON DEVICE: ON CBDP CAMEO If daylight sensor is not present, lights will turn on to 00% KEYPAD D KEYPAD LAYOUT & "MODIFIED" LAYOUT Button Functionality: Dim lights up B ST N COMPATIBILITY WITH OLDER SHEETS. DRAWING: 6 7 Button Functionality: OFF OF Dim lights down Button Functionality: OFF KEYPAD TYPE F 6 8 Office, Conference Room, Cafeteria, Library, Multipurpose Room, Lobby, Ballroom Office, Conference Room, Classroom, Library Space Number(s): NOTE THAT SEVERAL S HAVE BEEN REMOVED FROM THIS SHEET, BUT NUMBERS ARE UNCHAINED TO MAINTAIN COMPATIBILITY WITH OLDER SHEETS. 06 Crestron Electronics, Inc. WS_09 06 Page of 6 BUTTON BUTTON BUTTON KEYPAD TYPE E ON SCENE SCENE SCENE OFF Button Functionality: SCENE Recalls scene settings with feedback Button Functionality: ON If daylight sensor is not present, lights will turn on to 00% Button Functionality: SCENE Recalls scene settings with feedback Button Functionality: SCENE Recalls scene settings with feedback Button Functionality: OFF Turn all lights off to 0% and disable daylight harvesting Button Functionality: SCENE Recalls scene settings with feedback Button Functionality: ALL OFF Turn all lights off to 0% and disable daylight harvesting Button 6 Functionality: Dim lights up ENGRAVING FORMS ON THE NEXT PAGE 6 BU STY BU STY 6 7 BU B ST BUT B ST
Specification Worksheet GLPHASE System GLPHASE SpaceBuilder Sequence of Operations, Continued KEYPAD TYPE G : Office, Conference Room, Classroom, Library, Applications where dimming and switching both exist and need separate control KEYPAD TYPE N : Office, Conference Room, Classroom, Library, Applications where shades control is needed DIMMING ON / OFF SWITCHING ON / OFF KEYPAD TYPE H ON SCENE SCENE ALL OFF SHADES Button Functionality: DIMMING ON/OFF Toggle dimmable zones on or off with feedback if any lights are on Toggle to turn daylight harvesting on or off If daylight sensor is not present, lights will turn on to 00% Button Functionality: Dim lights up Button Functionality: Dim lights down Button Functionality: SWITCHING ON/OFF Toggle dimmable zones on or off with feedback if any lights are on BUTTON : Office, Conference Room, Classroom, Library, Applications where shades control is needed BUTTON ON / OFF ZONE ZONE ZONE ZONE 6 7 BUTTON Button Functionality: ALL ON / OFF Toggle all lights on and off Button Functionality: ZONE Zone on, press and hold for off Button Functionality: ZONE Zone on, press and hold for off Button Functionality: ZONE Zone on, press and hold for off Button Functionality: ZONE Zone on, press and hold for off BUTTON Button 6 Functionality: Dim last touched zone up Button 7 Functionality: Dim last touched zone down Button Functionality: ALL ON ENGRAVING FORMS ON THE NEXT PAGE NOTE THAT If daylight SEVERAL sensor S is not present, HAVE lights BEEN will REMOVED turn on to 00% FROM THIS SHEET, BUT KEYPAD TYPE NUMBERS X All applications ARE UNCHAINED needing a custom keypad TO MAINTAIN button configuration COMPATIBILITY and functionality WITH OLDER SHEETS. Button Functionality: SCENE Recalls scene settings with feedback Custom Keypad SOO Button Functionality: SCENE Recalls scene 6 settings 7 with feedback Button Functionality: ALL OFF BUTTON PLEASE USE THESE S AS A GUIDE TO FILL OUT THE MODIFIED KEYPAD LAYOUT & Button Functionality: SHADES Activates up and down arrows to control shades. After seconds of inactivity, up and down arrows revert back to dimming lights up and down. Button 6 Functionality: Dim lights up (shades up when SHADES button is active) Button 7 Functionality: Dim lights down (shades down when SHADES button is active) CBDP KEYPAD ENGRAVING SHEET MODIFIED KEYPAD LAYOUTS 6 8 9 BUT 6 BUT STYL 6 Note 7 By selecting keypad types, the SpaceBuilder system will be programmed, packaged, and shipped from the factory as an operable turnkey lighting control solution. Additional onsite support may be required for scene or sensor calibration. BUTT GLPHASE KP KP KP KP Date: Project: 06 Crestron Electronics, Inc. WS_09 06 Page of 6 BUTTON BUTTON BUTTON BUTTON BUTTON BUTTON BUTT
Specification Worksheet GLPHASE System GLPHASE Specifications LOAD RATINGS Dimmer Channels DINDIMU: Maximum Per Channel Amps @ 0 to 0 Volts AC, 0/60 Hz 600 Watts @ 0 Volts AC 0 Watts @ 0 Volts AC 00 Watts @ 0 Volts AC Load Types Forward Phase (leading edge) or Reverse Phase (trailing edge) Electronic Low Voltage, Incandescent, Neon/Cold Cathode, Magnetic Low Voltage, Dimmable Wire Fluorescent, and NonDim Lighting ENCLOSURE Surface mount metal box enclosure, suitable for mounting in plenum airspace Width.7 in (66 mm) Depth.8 in ( mm) ELECTRICAL REGULATORY CERTIFICATIONS Relays tested and certified for Electronic Ballasts according to UL08, Section (Endurance Test) and Section 6C (Electronic Ballasts) IEC60669, Section 9.0 (Contact mechanisms incorporated in electronic switches, intended for fluorescent lamp circuits or other capacitive loads) CEC Title 0 Compliant channels of forward or reverse phase dimming Auto load detection 0 to 0 Volt 0/60 Hz operation ENVIRONMENTAL Temperature to 0 F (0 to 0 C) Humidity 0% to 90% RH (noncondensing) DIMENSIONS Height. in (97 mm) Products in this system can include: DINDIMU: Channel Universal Dimmer GLSODTC: Dual Technology Ceiling Mount Occupancy Sensor GLSLOL: Open Loop Daylight Sensor TSW70: 7 Touch Screen CBD: Keypad For technical specifications on all other products in this system, please visit www.crestronlighting.com For more information or to access digital specification forms for all Crestron SpaceBuilder systems, visit www.crestronspacebuilder.com or call 8676 GLPHASE KP KP KP KP Date: Project: 06 Crestron Electronics, Inc. WS_09 06 Page 6 of 6