How OPC UA Software Enhances Big Data Integrity for IIoT SCADA Systems. Charles Chen Product Manager

Similar documents
Building a Future-Proof Data- Processing Solution with Intelligent IoT Gateways. Johnny T.L. Fang Product Manager

WHITE PAPER. How to Select a Cellular RTU for Water and Wastewater Applications. Charles Chen Product Manager Moxa Inc.

New Technology Automates Arduous Modbus Routing Setup in Gateways. Dr. Sean Chen Product Manager

Enabling Mobility in Network Monitoring. Yiwei Chen Moxa Product Manager

Using a RESTful API to Connect to Remote I/Os

Remote Monitoring and Alarm Solution

How Industrial PoE Switches Facilitate Reliable Outdoor IP Surveillance Networks. Jackey Hsueh Product Manager

Five Key Considerations When Implementing Secure Remote Access to Your IIoT Machines. Blanch Huang Product Manager

Extending Ethernet over 2-wire Copper Networks

WHITE PAPER. Expert Tips for Planning an Industrial Wireless Network. Mike Werning Field Application Engineer, Moxa Americas

New Locations and New Requirements for Onboard IP CCTV. Harry Hsiao Product Manager

Securing Network Devices with the IEC Standard What You Should Know. Vance Chen Product Manager

One Gateway That Can Do It All

How to Upload Device Data to a Remote Database Using the Log Upload Function

Deploy Your I/O Data to the Cloud

Moxa White Paper. Requirements for Ethernet Networks in Substation Automation. Certification and Hardware Requirements. Alvis Chen

How to Build an IoT Application with Moxa's ThingsPro and AWS IoT Service

An Oracle White Paper October The New Oracle Enterprise Manager Database Control 11g Release 2 Now Managing Oracle Clusterware

Adding Mobile Capability to an Enterprise Application With Oracle Database Lite. An Oracle White Paper June 2007

IT and Instrumentation for industry. Modular RTU Controller: IoPAC 8000 Series. Cellular RTU Controller: iologik W5300 Series

How to Choose an Outdoor IP Camera. Edward Lu Business Development Manager, Moxa Inc.

Chapter 2 State Estimation and Visualization

How to Build a Real-Time IIoT Application with Moxa's ThingsPro and Cirrus Link's Sparkplug

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

Repairing the Broken State of Data Protection

Combo Serial Device Servers Deliver Higher Overall Equipment Effectiveness for Shop Floors

Information Lifecycle Management for Business Data. An Oracle White Paper September 2005

3 Major Considerations to Bring Industrial IoT to Reality Péter Bóna, CEO, Com-Forth Kft. Budapest, 15th May 2018

The SCADA Connection: Moving Beyond Auto Dialers

Ethernet Convergence in Mobile Oil and Gas Applications. Mike Werning Field Application Engineer, Moxa Americas

STORAGE CONSOLIDATION AND THE SUN ZFS STORAGE APPLIANCE

SCADA Getting Smarter Gary Clouser April 1, 2013

Create Individual Membership. This step-by-step guide takes you through the process to create an Individual Membership.

Sensaphone SCADA 3000

Solving the challenge

Avoiding the Pitfalls of Embedded Application Programming

Improve Data Integration with Changed Data Capture. An Oracle Data Integrator Technical Brief Updated December 2006

Methods for Embedding Video Streams in SCADA Systems

Automation Services and Solutions

Challenges of Multivendor Systems in Implementation of IIoT-ready PLCs. ISA/Honeywell Webinar 10 November 2016

Improving SCADA Operations Using Wireless Instrumentation

Instant evolution in the age of digitization. Turn technology into your competitive advantage

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O

An Oracle White Paper June Exadata Hybrid Columnar Compression (EHCC)

The SCADA Connection: Moving Beyond Auto Dialers

Oracle Enterprise Performance Reporting Cloud. What s New in September 2016 Release (16.09)

Connecting Legacy Equipment to the Industrial Internet of Things White Paper

Real-Time Insights from the Source

WHY BUILDING SECURITY SYSTEMS NEED CONTINUOUS AVAILABILITY

Create Faculty Membership Account. This step-by-step guide takes you through the process to create a Faculty Membership Account.

Leverage the Oracle Data Integration Platform Inside Azure and Amazon Cloud

Cloud Operations for Oracle Cloud Machine ORACLE WHITE PAPER MARCH 2017

Fog Computing. ICTN6875: Emerging Technology. Billy Short 7/20/2016

SCADA Solutions Since 1981 DATA FLOW SYSTEMS

Introduction to RTU Controllers

Connecting the iologik 2000 to a SolarWinds NPM

ENHANCING INTELLIGENCE IN THE INTERNET OF THINGS The Business of Embedded Virtualization Alexander Damisch, Director, Industrial Vertical, Wind River

21 st Century Landfill Technology: Telemetry, Automation, and Alternative Power Sources

Choosing a Multiport Serial Board for Serial Communication

How to Use ThingsPro Gateway to Publish Processed Edge Data to the AWS IoT Cloud. 1 Background Requirements Overview...

iologik 2500 HSPA/GPRS/WLAN Series

IT Boosting Employee & Business Productivity with Innovative Technologies and Solutions Refresh Now

Maximum Availability Architecture. Oracle Best Practices For High Availability

Mobility Solutions HMI SCADA THE RIGHT INFORMATION TO THE RIGHT PERSON AT THE RIGHT PLACE AT THE RIGHT TIME SECURELY PRESENTED.

Mesh Networking Principles

Multichannel Connect for Salesforce CRM Integration Guide

Acquiring Operational and Non-Operational Data from Substation IEDs Smart Grid Tutorial

All Aboard the SCADA Mothership

NPort Operation Mode Guidance

Oracle Exadata Statement of Direction NOVEMBER 2017

Connect Different Protocols It s Quick, Easy, and Reliable

TetraNode Scalability and Performance. White paper

Mobility Solutions HMI SCADA THE RIGHT INFORMATION TO THE RIGHT PERSON AT THE RIGHT PLACE AT THE RIGHT TIME SECURELY PRESENTED.

Device Connectivity Is the Key to Optimal OEE in Industry 4.0. Rick Peng Product Manager

5 STEPS for Turning Data into Actionable Insights

How Emerson s I/O on Demand Is Changing the Automation Infrastructure

Intelligent Remote Terminal Unit (irtu) in the IoT Era

Paper. It s all about input, connectivity, decision making, and output instructions.

Acquiring Operational and Non-Operational Data From Substation IEDs. The Smart Grid. Operational Data. Non-Operational Data POWERING POTENTIA L

Optimizing Industrial Networks for HD IP Surveillance: An In-Depth Case Study

An Oracle White Paper June StorageTek In-Drive Reclaim Accelerator for the StorageTek T10000B Tape Drive and StorageTek Virtual Storage Manager

Distributed Hybrid MDM, aka Virtual MDM Optional Add-on, for WhamTech SmartData Fabric

Passive Wireless Needs at Yokogawa

Abstract. Introduction

DATRAN VI PRODUCT RELEASE NOTICE DATRAN VI RELEASE March 2011

WATERVISION INTEGRATED REMOTE IRRIGATION MANAGEMENT

Oracle Responsys Release. Release Content Document. August 2016

An Oracle White Paper October Oracle Social Cloud Platform Text Analytics

Oracle Enterprise Performance Reporting Cloud

APPLIED SATELLITE ENGINEERING-MACHINE-TO-MACHINE. This resource is brought to you by ASE M2M. Contact information.

Chapter 2. Literature Survey. 2.1 Remote access technologies

Oracle Grid Infrastructure 12c Release 2 Cluster Domains O R A C L E W H I T E P A P E R N O V E M B E R

SCADA.What s out there?

Achieving Optimal Returns from Wellhead Operations

Converged Power Solutions. Data center power reinvented

August Oracle - GoldenGate Statement of Direction

Telecom Italia Smart sustainable cities experiences

Oracle NoSQL Database For Time Series Data O R A C L E W H I T E P A P E R D E C E M B E R

POWER-ONE ITALY, 5 TH JUNE 2018 Cloud, Big Data & Cyber Security. Business, Opportunities and Risks

An Oracle White Paper September Oracle Utilities Meter Data Management Demonstrates Extreme Performance on Oracle Exadata/Exalogic

Transcription:

How OPC UA Software Enhances Big Data Integrity for IIoT SCADA Systems Charles Chen Product Manager

Big Data Integrity Is a Critical Factor in the Evolution from Traditional to IIoT SCADA Systems Over the past several years, SCADA systems have evolved from proprietary, monolithic systems to decentralized, cloud-computing systems. Modern SCADA systems are quickly adopting Industrial Internet of Things (IIoT) technologies, such as cloud services or pub/sub protocols, to collect more data from monitored systems. This move is essentially mandatory, due to the fact that the amount of data involved is expanding at an ever-increasing rate. In fact, the amount of data today s SCADA systems manage is thousands of times greater than traditional SCADA systems from a decade or two ago. IIoT technology provides faster computing speed, more data storage space, and advanced analysis capabilities, giving supervisors the ability to extract valuable business insights from big data, at a lower infrastructure cost and with less maintenance effort. SCADA system operation has changed from passively monitoring equipment status to proactively improving Overall Equipment Effectiveness (OEE) and control. Users are no longer satisfied with basic, printed, trend charttype reports, but instead demand immediate access to analysis results more often than not through a cell phone or tablet computer giving them the ability to make on-the-spot decisions from essentially any location on the planet. Traditional SCADA System IIoT SCADA System Purpose Remote monitoring and data acquisition Improving Overall Equipment Effectiveness (OEE)* and process-wide overview of seed data for long-cycle system management. Preventive maintenance Predictive analytics Control Supervisory control Optimized proactive control Reports Historical trend charts Analytics for new business models Alarms Immediate-action management within the OCC (Operation Control Center) Dispatch actions to anywhere through mobile devices *OEE identifies the percentage of resource-usage time that is truly productive. However, automated analysis can sometimes lead to surprising results, in which case systems engineers would be justified to question whether or not the big data, and the automated analysis, is accurate. Everyone has heard the old adage, garbage in, garbage out, but the reality is that ensuring the quality and integrity of big data is much easier said than done. Released on July 20, 2016 All rights reserved. Moxa is a leading manufacturer of industrial networking, computing, and automation solutions. With over 25 years of industry experience, Moxa has connected more than 40 million devices worldwide and has a distribution and service network that reaches customers in more than 70 countries. Moxa delivers lasting business value by empowering industry with reliable networks and sincere service for automation systems. Information about Moxa s solutions is available at www.moxa.com. How to contact Moxa Tel: 1-714-528-6777 Fax: 1-714-528-6778 1

Smart Data Acquisition Enhances Big Data Integrity The sheer quantity of data churned out by thousands and thousands of sensors can put a tremendous load on legacy data acquisition methods. For many years now updating data by polling, which is the norm for SCADA software, has been the industry standard for communication between the server and clients. In the IIoT era, legacy polling methods do not mix well with big data, particularly since by its very nature, polling results in the collection of tons of worthless data from thousands of sensors, leading to high data storage costs and time consuming data analyses. When your sensors spit out data at a frequency much smaller than the polling interval, such as is the case when monitoring a machine s ON/OFF status, updating by exception can reduce the amount of data storage and increase the efficiency of data analysis. With wireless technology quickly becoming the connection option of choice for IIoT applications, mainly due to its convenience and mobility, the stability of wireless communications is a critical issue. A cause for concern is the inevitable unexpected connection interruptions that plague any wireless network, and which could result in data loss and expensive shutdowns of important business processes. Most SCADA systems support saving data to a database in real time. However, data loss will occur when the network connecting the SCADA software with the remote I/O devices goes offline, or when the SCADA software crashes. A common solution to this problem is to back up data in local storage devices located near the remote I/O devices. However, extra programming effort is required to collect offline data logs from the local storage devices and parse it to a database, since most SCADA software does not provide this kind of solution. The critical drawbacks are: Third-party or in-house software engineers need to create additional software to handle data completeness. Developing this kind of software is costly and difficult to integrate and maintain. An operations engineer needs to define the start and end time of the data loss duration for each remote I/O device, and the engineer needs to manually trigger the data completeness process, increasing the chance of collecting duplicate data or neglecting the data-loss duration altogether. A solution that provides an automatic data completeness function can save users a lot of development and maintenance effort. 2

Adopting OPC UA Software to Implement Smart Data Acquisition SCADA software and OPC servers have traditionally been based on a client-server polling model. About ten years ago, Moxa introduced its patented Active OPC concept, which is implemented by Moxa s iologik products. The iologik can poll local meters and sensors as frequently as it likes without putting any burden on the Ethernet network, and only sends readings to the OPC server (over the Ethernet network) when certain pre-configured conditions are met. Engineers can decide between updating data by polling and updating data by exception. Deciding which option to choose depends on two factors: (1) the frequency with which sensor readings change, and (2) the urgency with which you need to know that a reading has changed. The Moxa white paper How OPC UA Servers Facilitate Efficient SCADA Device Data Management explains the details of the concept. When used together, Moxa s iologik 2500 series, MX-AOPC UA Server, and MX-AOPC UA Logger form a turnkey solution that provides real-time data acquisition, data buffering in local storage devices, and automatic data completeness after network failures. MX-AOPC UA Logger imports data from MX-AOPC UA Server into a database in real time. When the network fails and then recovers, the logger automatically retrieves data logs, with timestamp matching the duration of the disconnection, from the data buffers of specific iologik 2500 devices, and then pushes the supplementary data into the database. Big data quality and integrity are fundamental requirements of a successful IIoT. As companies adopt more IIoT solutions and analysis methods, it is important to keep improving data acquisition methods as well. With Moxa s smart data acquisition methods, data acquisition becomes more efficient and accurate, and companies are better able to extract more valuable business insights from IIoT solutions. Case Study: Radio Station Equipment Monitoring Many leading wireless carriers throughout the world are looking for cost-effective and efficient ways to manage remote, unmanned sites. The traditional method of sending maintenance personnel on regular, onsite visits is both inconvenient and costly. The obvious solution is to make it possible for maintenance engineers to remotely monitor and manage the unmanned sites efficiently, and proactively maintain and control their systems to prevent system downtime. In addition, since interruptions in wireless transmission are inevitable, during the 3

disconnection period, data is saved to a local RTU. When the wireless network is back online, the data can be sent back to the central database automatically. One solution provider uses Moxa s iologik 2542-HSPA-T, MX-AOPC UA Server, and MX-AOPC UA Logger combined with their own SCADA software on a private cloud to provide a nationwide solution for radio station equipment monitoring. With this solution, engineers can monitor: radio equipment lighting on radio towers to ensure compliance with flight safety regulations the backup power system, including the battery, diesel oil level, and diesel generator cabinet intrusion detection indicators, equipment rooms, and areas that are off limits In one application, about 100 unmanned sites are being monitored. One iologik 2542-HSPA-T is installed at each site. Each iologik monitors 12 analog inputs and updates the data to MX- AOPC UA Server using a percentage change strategy. The iologik also monitors 8 digital inputs and updates data to the server by exception, resulting in a dramatic reduction in the amount of data that needs to be transmitted. In addition, the amount of storage space required at the central site is greatly reduced. Whenever the connection between the iologik 2542-HSPA-T and MX-AOPC UA Server gets disconnected, it saves the data in its local storage drive for backup purposes. Once the connection is back up and running, the MX-AOPC UA Logger automatically retrieves the data from the local storage drive and pushes the data to the central database. Moxa s iologik 2542-HSPA-T, MX-AOPC UA Server, and MX-AOPC UA Logger not only make it easy for the solution provider to transmit data to the database in real time, this combination of tools provides complete data by automatically pushing supplementary data, stored locally during disconnection periods, to the central database. The system not only enhances data integrity, it also provides SCADA engineers with prompt and accurate data analysis. 4

Disclaimer This document is provided for information purposes only, and the contents hereof are subject to change without notice. This document is not warranted to be error-free, nor subject to any other warranties or conditions, whether expressed orally or implied by law, including implied warranties and conditions of merchantability, or fitness for a particular purpose. We specifically disclaim any liability with respect to this document and no contractual obligations are formed either directly or indirectly by this document. 5