Electromagnetic Compatibility Guidelines

Similar documents
Electromagnetic Compatibility Guidelines

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

24-Channel, ±24 V Precision PXI Source Measure Unit

12-Channel, ±24 V Precision PXI Source Measure Unit

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

To access NI 5622 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI PXIe Contents GETTING STARTED GUIDE. RF Preselector Module

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

NI PXI Contents GETTING STARTED GUIDE. 8 GHz RF Amplifier

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

NI PXIe-4080/4081/4082

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

NI PXI/PXIe/PCI Contents GETTING STARTED GUIDE. 14-Bit, 100 MS/s PXI Oscilloscope

PXI/PCI Contents GETTING STARTED GUIDE. 2 GS/s Oscilloscope

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

To access NI 5105 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

SH Cable Specifications

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

Electrical. SPECIFICATIONS SH Cable

Bracket and Mounting Dimensions

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

To access NI 5114 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

Thermal Kit for NI sbrio-9607/9627/9637

NI PXI-5650/5651/5652

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

CALIBRATION PROCEDURE CAL Contents. Software

INSTALLATION GUIDE AND SPECIFICATIONS PXIe-4844

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

NI R Series. Contents. Software CALIBRATION PROCEDURE

NI PXIe-6544/6545/6547/6548

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

Single-Channel Precision System Source Measure Unit (SMU)

Contents. Software CALIBRATION PROCEDURE NI TC-4353

This document includes instructions for installing and configuring your PXIe-8861 PXI Express controller module.

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

This document includes instructions for installing and configuring your PXIe-8821 PXI Express controller module.

USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4340 and TB Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

To access NI 5671 documentation, navigate to Start»All Programs»National Instruments» NI-RFSG»Documentation.

NI PXIe-6555/6556. Contents GETTING STARTED GUIDE. 200 MHz Digital Waveform Generator/Analyzer with PPMU

This document describes the features, functions, and operation of the NI PXIe-8383mc PXImc adapter module.

NI PXI Contents GETTING STARTED GUIDE

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

USER GUIDE I/O Accessory For the NI PCIe-8237R GigE Vision Interface Device

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

100 MHz, 250 MS/s, 14-Bit PXI Express Oscilloscope. This document explains how to install and start using the PXIe-5172.

USRP Contents. Verifying the System Requirements GETTING STARTED GUIDE. USRP Software Defined Radio Stand-Alone Device

Foundation Fieldbus Hardware and NI-FBUS Software

Electromagnetic Compatibility Guidelines

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

NI crio-9101/9102/9103/9104

Contents. Software Requirements CALIBRATION PROCEDURE NI TB-4353

Electromagnetic Compatibility Guidelines

RTM Contents. Definitions. Conditions SPECIFICATIONS. PCI Express Rear Transition Module for ATCA

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-4357

NI PXI-2567 Specifications

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4322 and TB Channel, Isolated Voltage/Current Analog Output Module

RTM Contents. Definitions. Conditions SPECIFICATIONS. High-Speed Serial Rear Transition Module for ATCA

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

6 GHz Reconfigurable RF Vector Signal Transceiver with 1 GHz Bandwidth

Electromagnetic Compatibility Guidelines

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4339 and TB-4339/B/C 8 Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module

Contents. CALIBRATION PROCEDURE NI PXIe-5624R 2 GS/s, 12-Bit IF Digitizer

NI SMB-2145/2146/2147/2148

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4357 and TB-4357

10 MHz to 6 GHz, x86 Processor, GPS-Disciplined OCXO, USRP Software Defined Radio Stand-Alone Device

NI CMS-9068 and NI MMS-9068

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

These specifications apply to the 1 m and 3 m TriaxM-TriaxM. it in a manner not described in this document.

USB Definitions. Conditions. Analog Input SPECIFICATIONS. 8 AI (10 ks/s), 4 DIO USB Multifunction I/O Device

Getting Started with the NI 8234

Transcription:

GETTING STATED GUIDE NI PXIe-4463 DSA Analog Output This document explains how to install, configure, and set up the NI PXIe-4463 Dynamic Signal Acquisition (DSA) analog output module. Driver support for the NI PXIe-4463 was first available in NI-DAQmx 14.5. For the list of devices supported by a specific release, refer to the NI-DAQmx eadme, available on the version-specific download page or installation media. To download the latest version of NI-DAQmx, visit ni.com/info and enter the Info Code daqmx. The NI PXIe-4463 is available with BNC connectors or Mini-XL connectors. Contents Electromagnetic Compatibility Guidelines... 1 Unpack the Kit... 2 Prepare the Environment... 2 Verify the Kit Contents... 3 Other Equipment... 3 Install the Software... 3 Install the Hardware... 4 Configure the Hardware in MAX... 5 Connect the NI PXIe-4463 Output... 6 NI PXIe-4463 Output Connections... 7 NI PXIe-4463 Front Panel LEDs... 8 Environmental Management... 9 Worldwide Support and Services... 9 Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio

and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Caution To ensure the specified EMC performance, the length of all I/O cables must be no longer than 3 m (10 ft). Unpack the Kit The NI PXIe-4463 module ships in an antistatic package to prevent electrostatic discharge from damaging module components. To prevent such damage when handling the module, ground yourself using a grounding strap or by holding a grounded object, and complete the following steps: 1. Touch the antistatic package to a metal part of the grounded object before removing the module from package. 2. emove the module from the package and inspect the module for loose components or any other sign of damage. Caution Never touch the exposed pins of connectors. 3. Unpack any other items and documentation from the kit. Notify NI if the module appears damaged in any way. Do not install a damaged module into your system. Store the module in the antistatic package when not in use. Prepare the Environment Ensure that the environment in which you are using the NI PXIe-4463 meets the following specifications. Operating ambient temperature...0 C to 55 C (IEC 60068-2-1, IEC 60068-2-2) Operating relative humidity...10% to 90%, noncondensing (IEC 60068-2-56) Altitude...2,000 m (800 mbar) (at 25 C ambient temperature) Pollution Degree...2 Indoor use only. 2 ni.com NI PXIe-4463 Analog Output Getting Started Guide

Caution Clean the hardware with a soft, nonmetallic brush. Make sure that the hardware is completely dry and free from contaminants before returning it to service. Note efer to the NI PXIe-4463 Specifications at ni.com/manuals for complete specifications. Verify the Kit Contents The following items are necessary to set up and use the NI PXIe-4463: NI PXIe-4463 analog output module NI-DAQmx installation media NI PXIe-4463 Getting Started Guide Note You can download any needed documents from ni.com/manuals. Other Equipment The following additional items, not included in the module kit, are necessary to operate the NI PXIe-4463: PXI Express chassis with controller, or MXI-Express (card or built-in) (optional) NI LabVIEW Note For a list of LabVIEW versions supported by a specific version of NI-DAQmx, refer to the NI-DAQmx eadme, available on the version-specific download page at ni.com/downloads or on the installation media. Install the Software Software support for the NI PXIe-4463 is provided by NI-DAQmx. The DAQ Getting Started Guide, which you can download at ni.com/manuals, describes how to install NI-DAQmx software, how to install and configure your NI-DAQmx supported hardware, and how to confirm that your device is operating properly. For detailed NI software version support, refer to the NI-DAQmx eadme. You must install the software before using the hardware. 1. Optional: If you are developing an NI-DAQmx application, install an ADE, such as LabVIEW or LabWindows /CVI. 2. Install the latest service packs for your operating system. 3. Install a compatible version of NI-DAQmx. To download the NI-DAQmx driver, visit ni.com/info and enter the Info Code daqmx. 4. Follow the instructions in the installation prompts. NI PXIe-4463 Analog Output Getting Started Guide National Instruments 3

Note Windows users may see access and security messages during installation. Accept the prompts to complete the installation. For troubleshooting information, refer to the Worldwide Support and Services section. 5. When installation completes, select estart in the dialog box that asks if you want to restart, shut down, or restart later. 6. Optional: Download the NI Dynamic Signal Analyzer (DSA) and NI Dynamic Signal Generator (DSG) soft front panels (SFP) to aid with signal generation and spectral measurements. For more information about the SFPs, visit ni.com/info and enter the Info Code exqpwb. Install the Hardware Note To maintain forced air cooling in the PXIe system, refer to the Maintain Forced-Air Cooling document. 1. Plug in your chassis before installing the NI PXIe-4463 module. The power cord grounds the chassis and protects it from electrical damage while you install the module. 2. Make sure the chassis is powered off. Caution To protect yourself, the chassis, and the module from electrical hazards, leave the chassis powered off until you finish installing the module. 3. Touch a metal part on the chassis to discharge any accumulated static electricity. 4. emove the protective plastic covers from the two front panel mounting screws on the module. 5. emove the filler panels covering the selected slots. 6. Make sure the NI PXIe-4463 injector/ejector handle is in its downward position as shown in Figure 1. Caution When installing the module, make sure both edges are positioned inside the guides and that the module components do not come into contact with adjacent modules. 7. Align the NI PXIe-4463 with the card guides on the top and bottom of the selected slots. 8. Hold the injector/ejector handle down as you slowly slide the module into the chassis until the handle catches on the injector/ejector rail, as shown in Figure 1. 4 ni.com NI PXIe-4463 Analog Output Getting Started Guide

Figure 1. Sliding the NI PXIe-4463 into the Chassis 1 2 3 1 Chassis 2 Hardware Module (Mini-XL model shown) 3 Injector/Ejector Handle in Down (Unlatched) Position 9. aise the injector/ejector handle to latch the module into the chassis. The front panel of the NI PXIe-4463 should be even with the front panel of the chassis. 10. Tighten the top and bottom module mounting screws, shown in Figure 2, to 0.31 N m (2.7 lb in.) on the top and bottom of the module front panel to secure the NI PXIe-4463 to the chassis. Note Tightening the top and bottom mounting screws increases mechanical stability and also serves to electrically connect the front panel to the chassis, which can improve the signal quality and electromagnetic performance. 11. Power on the chassis. Configure the Hardware in MAX Use Measurement & Automation Explorer (MAX) to configure your National Instruments hardware. MAX informs other programs about which devices reside in the system and how they are configured. MAX is automatically installed with NI-DAQmx. 1. Launch MAX. 2. In the Configuration pane, expand Devices and Interfaces to see a list of installed devices. Installed devices appear under the name of their associated chassis. 3. Expand your Chassis tree item. Note vary. MAX lists all devices installed in the chassis. Your default device names may 4. ecord the device identifier MAX uses to identify the hardware. Use this identifier when programming the NI PXIe-4463. NI PXIe-4463 Analog Output Getting Started Guide National Instruments 5

Connect the NI PXIe-4463 Output Figure 2 shows the front panel connections of the NI PXIe-4463 with BNC connectors and the NI PXIe-4463 with Mini-XL connectors. Note efer to the NI PXIe-4463 Specifications for information about the operating output range and overvoltage protection. Figure 2. NI PXIe-4463 BNC and Mini-XL Connector Front Panel 1 1 2 NI PXIe-4463 DSA Analog Output ACCESS AO 0 AO 1 2 NI PXIe-4463 DSA Analog Output ACCESS AO 0 AO 1 3 PFI 0 3 PFI 0 4 PFI 1 4 PFI 1 AO 0 AO 0 5 5 4 6 6 4 AO 1 AO 1 7 7 1 Top Module Mounting Screw 2 LEDs 3 PFI 4 Chassis Ground 5 AO+ 6 AO- 7 Bottom Module Mounting Screw 6 ni.com NI PXIe-4463 Analog Output Getting Started Guide

NI PXIe-4463 Output Connections Figure 3 shows the NI PXIe-4463 analog output block diagram. Depending on the connector type, connect the signals as shown on the inset. Figure 3. NI PXIe-4463 Analog Output Block Diagram Low-Pass Filter Attenuator Differential Amplifier Output Enable elay 18.6 1.4 DAC Gain = 0 db Gain = 17 db Gain = 37 db 18.6 Output Configuration elay 1.4 BNC Connector Mini-XL Connector 4.96 k 4.96 k 50 1 3 2 Output Configuration elay Differential OFF Pseudodifferential ON The NI PXIe-4463 output stage is a differential amplifier. The output stage can be configured to pseudodifferential mode in software, where the -AOn terminal is internally connected to chassis ground through a 50 Ω resistor. This connection introduces a gain difference in the output stage of -31.8 mdb, for which the software corrects automatically. efer to the NI-DAQmx Help for more information about terminal configuration. The NI PXIe-4463 output stage can also be configured to pseudodifferential mode by making an external connection between or -AOn to chassis ground. This connection introduces a gain change in the output stage of -34.8 mdb, for which the software does not correct. For most applications, configuring the NI PXIe-4463 output stage in differential mode will yield the best performance. For improved common-mode noise rejection, it is highly recommended to make a connection between the chassis ground of the NI PXIe-4463 and the input device ground. This connection is critical when the input device is isolated; if this connection is not available, it may be better to configure the NI PXIe-4463 output stage in pseudodifferential mode. Figures 4 and 5 show the recommended output connections for both connector types. Figure 4. NI PXIe-4463 Mini-XL ecommended Output Connection NI PXIe-4463 Front Panel Floating Load Ground-eferenced Balanced Load Ground-eferenced Unbalanced Load Mini-XL Grounded Shielding Enclosure NI PXIe-4463 Analog Output Getting Started Guide National Instruments 7

Figure 5. NI PXIe-4463 BNC ecommended Output Connection NI PXIe-4463 Front Panel Floating Load Ground-eferenced Balanced Load Ground-eferenced Unbalanced Load BNC + Ground Connection for Improved Common Mode Noise ejection Grounded Shielding Enclosure NI PXIe-4463 Front Panel LEDs LEDs on the front panel of the NI PXIe-4463 provide information about basic hardware status and status of the analog output channels. Table 1 describes the function of the front panel LEDs. Table 1. NI PXIe-4463 Front Panel LED Indicators LED ACCESS Indications Indicates the basic hardware status of the analog output module. OFF The module is not yet functional, or has detected a problem with a PXI power rail. AMBE The module is being accessed. GEEN The module is ready to be programmed. AO0, AO1 Indicates the status of the AO0 or AO1 analog output channel. AMBE/GEEN (alternating) The reference clock source is changing to onboard or PXIeClk100. AMBE (solid) The channel is waiting for a trigger to start generating. GEEN (solid) The channel is actively generating a signal. ED (solid) An error has been detected on the channel or board. Possible errors include the following: The board is overheated The power supply is not at the proper voltage A clocking error occurred (PLL fell out of lock or PXIeClk100 was not present when using the external timebase) An external overvoltage or overcurrent was detected * An overload was detected * A streaming underflow was detected on the channel Internal hardware failed (either due to software or hardware failure) * An external overvoltage, overcurrent, or overload error can be read through DAQmx property nodes. 8 ni.com NI PXIe-4463 Analog Output Getting Started Guide

Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste and Electronic Equipment, visit ni.com/environment/ weee. ohs National Instruments (ohs) National Instruments ohs ni.com/ environment/rohs_china (For information about China ohs compliance, go to ni.com/environment/rohs_china.) Worldwide Support and Services The National Instruments website is your complete resource for technical support. At ni.com/ support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your National Instruments product. Product registration facilitates technical support and ensures that you receive important information updates from NI. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. NI PXIe-4463 Analog Output Getting Started Guide National Instruments 9

efer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. efer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPESS O IMPLIED WAANTIES AS TO THE ACCUACY OF THE INFOMATION CONTAINED HEEIN AND SHALL NOT BE LIABLE FO ANY EOS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FA 52.227-14, DFA 252.227-7014, and DFA 252.227-7015. 2015 National Instruments. All rights reserved. 376375A-01 Mar15