General Specifications Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation 1.95W º to 6ºC (32º to 14ºF) -2º to ºC (-4º to 158ºF) 5 to 95% (non-condensing) No corrosive gases permitted IEC668-2-6 (Test Fc) IEC668-2-2 (Test Ea) 18VAC applied for 1 second > 1MΩ @ 5VDC Enclosure Type Open Equipment Agency Approvals UL58 File E139594, Canada & USA CE (EN61131-2*) Module Keying to Backplane Electronic Module Location Any I/O slot in a Productivity2 System Field Wiring Use ZIPLink Wiring System or removable terminal block (not included). See Wiring Options on page 5. See the EU Directive topic in the Productivity2 EU Directive Help File. Information can also be obtained at: www.productivity2.com Connector Type (not included) 18-Position Removable Terminal Block Weight 9g (3.2 oz) *Meets EMC and Safety requirements. See the D.O.C. for details. 1I.V 2I.V 3I.V 4I.V 5I.V 6I.V I.V 2 P2-8AD4DA-2 Analog Input/Output The P2-8AD4DA-2 Voltage Analog Input/Output Module provides eight channels of -1 VDC inputs and four channels of -1 VDC outputs for use with the Productivity2 System. General Specifications... 1 Input Specifications... 2 Output Specifications... 2 Wiring Diagram and Schematic... 3 Module Installation Procedure... 4 QR Code... 4 Hot Swap Information... 4 Wiring Options... 5 Module Configuration... 5 Linear Scaling... 6 Non-Linear Scaling... 6 OLED Panel Display Menus... Warning... 8 Removable Terminal Block Specifications........ 8 Sales 8-633-45 Terminal Block sold separately, (see wiring options on page 5). Warranty: Thirty-day money-back guarantee. Two-year limited replacement. (See www.productivity2.com for details). www.productivity2.com 1
Input Specifications Input Channels 8 inputs (1 common) Input Ranges - 5 VDC, - 1 VDC Signal Resolution 12-16 bit, depending on input resolution - 5V Input Resolution & Update Rate (See Note 1) Fine:.1 ms, 6μV, 16 bit Medium: 1.8 ms, 35μV, 14 bit Coarse: 444μs, 1.22 mv, 12 bit - 1V Input Resolution & Update Rate (See Note 1) Fine:.1 ms, 152μV, 16 bit Medium: 1.8 ms, 61μV, 14 bit Coarse: 444μs, 2.44 mv, 12 bit Data Range -65535 counts Maximum Continuous Overload ±1V, voltage input Input Impedance 1MΩ (±1%) voltage input Hardware Filter Characteristics Low pass 1st order, -3dB @ 8Hz Fine 56.8 ms All Channel Update Rate Medium: 14.24 ms (See Note 2) Coarse: 3.55 ms Conversion Method Successive approximation Accuracy vs. Temperature ±15ppm/ C maximum Maximum Inaccuracy.1% of range Linearity Error (end to end) ±.15% of range maximum Monotonic with no missing codes Input Stability and Repeatability ±.25% of range (after 1 minute warm-up) Full Scale Calibration Error (not including offset) ±.5% of range maximum Offset Calibration Error ±.5% of range maximum Maximum Crosstalk -96dB, 1LSB External DC Power Required 24VDC (-2% / +25%), 13mA Note 1: The Input Resolution of Fine returns 16 bit resolution. Medium and Coarse are 14 and 12 bit respectively. The 12 and 14 bit input values are scaled to -65535. Note 2: Valid when all channels are set for the same Input Resolution. Output Specifications Output Channels 4 (1 common) Module Signal Output Range Output Signal Resolution Resolution Value of LSB (least significant bit) Data Range Output Type Output Value in Fault Mode Load Impedance Maximum Capacitive Load Allowed Load Type Maximum Inaccuracy Maximum Full Scale Calibration Error (not including offset error) Maximum Offset Calibration Error Accuracy vs. Temperature Max Crosstalk Linearity Error (End to End) Output Stability and Repeatability Output Ripple Output Setting Time All Channel Update Rate Maximum Continuous Overload Type of Output Protection Output Signal (power-up, -down) - 1 VDC, - 5 VDC 16-bit - 5V = 6μV/count - 1V = 152μV/count 1 LSB = 1 count - 65535 counts Voltage sourcing/sinking at 1mA maximum V 1.5 kω.1μf Grounded.1% of range ±.65% of range maximum ±.65% of range maximum ±25ppm/ C max full scale calibration change (±.25% of range/ C) -96dB, 1 LSB ±.15% of full scale Monotonic with no missing codes ±.15% after 1 minute warm-up typical.1% of full scale at 5/6 Hz 5μs max, 5μs min (full scale change) 5ms Outputs current limited to 15mA typical 15VDC peak output voltage V 2 www.productivity2.com Tech Support -844-42
Wiring Diagram Schematic Voltage Input Circuits 4-Wire Voltage Transmitter V+ INTERNAL MODULE CIRCUITRY AC or DC Transmitter Power Supply 4-Wire Transmitter 3-Wire Voltage Transmitter 3-Wire Transmitter -5 VDC Load -1 VDC Load + + - + 24 VDC User Supplied Power Voltage Output Circuits V+ V+ V+ INPUT CHANNELS OUTPUT CHANNELS V1+ V2+ V3+ V4+ V5+ V6+ V+ V8+ V1+ V2+ V3+ V4+ V 24V+ 1 2 3 4 5 6 8 9 1 11 12 13 14 15 16 1 18 CH1 ADC CH2 ADC CH3 ADC CH4 ADC CH5 ADC CH6 ADC CH ADC CH8 ADC CH1 DAC CH2 DAC CH3 DAC CH4 DAC ISOLATED ANALOG CIRCUIT POWER NOTE: This module includes input and output channels. Before connecting field wiring, verify that you are connecting to the appropriate terminals. ISOLATED ANALOG CIRCUIT MON Sales 8-633-45 www.productivity2.com 3
Module Installation QR Code WARNING: Do not apply field power until the following steps are completed. See hot-swapping procedure for exceptions. 2 rotate to seated position Step One: Align module catch with base slot and rotate module into connector. Step Two: Pull top locking tab toward module face. Click indicates lock is engaged. Locked 1 Align with slot Unlocked Use any QR Code reader application to display the module s product insert. Step Three: Attach field wiring using the removable terminal block or ZIPLink wiring system. WIRE STRIP LENGTH Caution: If possible, remove field power prior to proceeding. If not, then EXTREME care MUST be taken to prevent damage to the module, or even personal injury due to a short circuit from the live terminal block. Important Hot-Swap Information The Productivity2 System supports hot-swap! Individual modules can be taken offline, removed, and replaced while the rest of the system continues controlling your process. Before attempting to use the hotswap feature, be sure to read the hot-swap topic in the programming software s help file or our online documentation at AutomationDirect.com for details on how to plan your installation for use of this powerful feature. 4 www.productivity2.com Tech Support -844-42
Wiring Options ZIPLink Connection System 1 Cable + ZIPLink Module = Complete System ZIPLink pre-wired terminal block cables.5m (1.6FT) cable 1.m (3.3FT) cable 2.m (6.6FT) cable ZL-P2-CBL18 ZL-P2-CBL18-1 ZL-P2-CBL18-2 Module Configuration Using the Hardware Configuration tool in the Productivity Suite programming software, drag and drop the P2-8AD4DA-2 module into the base configuration. Select Automatic Module Verification or No Verification and Enable Hot Swap. Also specify Input Range and Input Resolution for inputs along with Output Range and Stop Mode Value for outputs. If desired, assign a User Tagname to each input and output point (channel) selected and to each Status Bit Item. ZIPLink Modules Feed through ZL-RTB2 Terminal Block with pigtail cable 2 1.m (3.3FT) cable 2.m (6.6FT) cable ZL-P2-CBL18-1P ZL-P2-CBL18-2P 3 Screw Terminal Block only P2-RTB (Quantity 1) 4 Spring Clamp Terminal Block only P2-RTB-1 (Quantity 1) Sales 8-633-45 www.productivity2.com 5
Linear Scaling Non-Linear Scaling The Scale (Linear) function can be used to: Convert analog field input signals from the range which is native to the analog input module to an application specific range. Convert an application specific range to a range which is native to the analog output module. Make other linear conversions in ranges appropriate to the application. The Scale (Non-Linear) function can be used for Non-Linear applications. Level Transmitter Tank Level Level Transmitter 65535 22 125 Tank Level Select the Input and Output tags appropriate for the application. Convert raw input signals to engineering units for use in the program, or convert engineering units to output signals for control purposes max 1 2 3 4 5 6 6.5.5 1 1.55 2.25 3 4.55 6.5 Select the minimum and maximum values of the raw input signal. These values will relate to the minimum and maximum scaled values. 6 5 4 3 2 1 1 2 3 4 5 6 min min max 6 www.productivity2.com Tech Support -844-42
OLED Panel Display Power On Hold SEL button down to cycle through primary screens. Release button to select screen. PASSED SELF TEST Appears initially SETUP INFO STATUS INFO UNITS DECIMAL COUNTS UNITS HEX COUNTS UNITS VOLTS These screens will then auto cycle P2-8AD4DA-2 Fw. Rev. 1. This screen will auto cycle with status information End of Status Menu List Momentarily Press SEL button to toggle through secondary displays 1I 2I 3I 4I 1I H 2I H 3I H 4I H 1I.V 2I.V 3I.V 4I.V In: -5/1V Out: -5/1V Error Messages An existing error will be inserted into the cycling Status Info screen MISSING EXTERNAL 24VDC SELFTEST FAIL REPLACE MODULE 5I 6I I 5I H 6I H I H 5I.V 6I.V I.V Channels Enabled: End of Status Menu List MISSING CONFIG DATA 1I 2I 3I 4I 5I 6I I 1I H 2I H 3I H 4I H 5I H 6I H I H 1I.V 2I.V 3I.V 4I.V 5I.V 6I.V I.V Fault Messages Appear in place of data during a fault condition. 1I OVER 2I UNDER 3I 4I Input signal is OVER the maximum detectable by the module. Input signal = (Voltage) 1O 2O 3O 4O 1O H 2O H 3O H 4O H Note: SPARE denotes deselected channel 1O.V 2O.V 3O.V 4O.V Sales 8-633-45 www.productivity2.com
WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call Technical Support at -844-42. This publication is based on information that was available at the time it was printed. At AutomationDirect.com we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. Removable Terminal Block Specifications Part Number P2-RTB P2-RTB-1 Number of positions 18 Screw Terminals 18 Spring Clamp Terminals 3-16 AWG (.51-1.31 mm²) 28-16 AWG (.81-1.31 mm²) Wire Range Solid / Stranded Conductor Solid / Stranded Conductor 3/64 in. (1.2 mm) Insulation Maximum 3/64 in (1.2 mm) Insulation Maximum 1/4 in (6 - mm) Strip Length 19/64 in ( - 8 mm) Strip Length Conductors USE COPPER CONDUCTORS, 5ºC or equivalent. Screw Driver Width 1/8 in (3.8 mm) Maximum Screw Size M2 N/A Screw Torque 2.5 lb in (.28 N m) N/A Document Name Edition/Revision Date P2-8AD4DA-2-DS 1st Ed. 3/9/215 Copyright 215, AutomationDirect.com Incorporated/All Rights Reserved Worldwide 8 www.productivity2.com Tech Support -844-42