Pull Cord Time Delay Switch 3-wire version

Similar documents
Remote Time Delay Switch 3-wire version

Model HM-535 Power Supply Installation and Service Instructions

Weathersafe Vision. Installation & Operating Instructions

Product and functional description

MAINS DISTRIBUTION UNIT MDU14-CO

Quick Start Installation and User Manual

EMS Electrical Management System

Mini Recessed PIR. Model: PDFM360MINI. Installation & Operating Instructions

PS8 - II. Professional Power Sequencer. User s Manual

Product and functional description

18W Round LED Bulkhead Light with Microwave Sensor

Wiring Accessories for a Smarter Home

BOOSTMASTER ELECTRONIC BOOST TIMER

Single Channel Lighting Control Module

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Supplementary operating instructions for your air curtain system Controller TMC 500

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

S82S (3/7.5-W Models)

Digital Room Thermostat

EMS Electrical Management System

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

Slimline LED Floodlight

V E1B Snap-in I/O Module

V E2B Snap-in I/O Module

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

POCKET MULTIMETER Model No: MM18

Operating Instructions Differential Pressure Transducer PS27

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

B60 Domestic Voltage Optimisation Unit. Installation Manual

ProMinder Standard Heating System Installation Instructions

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

SCD96 DMX Output Interface. Installation guide

I/O module (Expansion module)

Ultra Slim Relays 24

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

TVAC25100 TVAC25110 User manual

Non-communicating room controllers

SOLARIMMERSION IV Advanced Installation Manual v1.9

Installation Instructions

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Operating instructions. Standstill monitor A / / 2011

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

AEXX-349 SERIES REMOTE DISPLAYS

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Model Number Structure

MAXIMA + Series ROTARY LEVEL CONTROL

PRODUCT SPECIFICATION. PC Board Relays. Series.

Documentation. GEM 3KW Power Module. Installation Manual. Revision 3 December 2104

1-channel shutter actuator 6A UP Installation Instructions

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Content. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 5

Installation Job Aid for VSP 4850GTS

Operating manual Solareg II BASIC

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Operating instructions. Speed monitor D / / 2014

User Manual - Energenie MiHome Double Wall Sockets (MIHO07, MIHO021, MIHO022, MIHO023)

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

MXA2080. Stereo Power Amplifier. Owner s Manual

Grundfos MAGNA, GENI Module

LED MODULES FOR MAINS VOLTAGE

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Electrical devices may only be mounted and connected by electrically skilled persons.

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

MAXIMA+ Series Rotary Level Indicator

Alpha Eclipse Pure Color 3600C Series

7 Day Digital Programmer 1 Channel Surface Mount

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

DCM Digital Control Modules

Conductive Level Controller

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

GUIDE TO MIU/7 1-10V CONVERTER INTERFACE UNIT

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

B60 Domestic Voltage Optimisation Unit. Installation Manual

2x 10W LED Slimline PIR Floodlight Twin Flood

ICS Entrance Management Sign Installation Guide. Version 1.0

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

V E1B Snap-in I/O Module

Non-communicating room controllers

SK CU4-PNT-C Part number:

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

Universal Keying Adapter 3+

Tempco Instruction Manual

2400W PIR Light Controller

B60 Domestic Voltage Optimisation Unit

CasétaTM PD-5WS-DV. SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number: Receiving Device

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

Relay actuators & Status indicating modules

7 Day Programmable Room Thermostat

Operating Instructions. DALI-Gateway

Progressive Industries, Inc. EMS Electrical Management System

LED Driver Linear / area fixed output

Transcription:

PCTDS3 energy saving controls Product Guide Pull Cord Time Delay Switch 3-wire version today, tomorrow and in the future Issue 3.0

Product Overview The PCTDS3 Pull Cord Time Delay Switch provides timed switching for lighting, heating, air conditioning and ventilation equipment. For locations suiting pull cord control, the unit offers easy activation of the connected load whilst saving energy by switching it off automatically when not required (after an adjustable period). At any time, the activation period may be extended with a further brief pull of the cord, or cancelled by holding momentarily. The unit is available with different time delay ranges (see Technical Specification). The unit is simple to install and fits a standard single-gang UK pattress or back box (28mm min. depth). Ideal applications include small booths or rooms, workshops, entrance halls, staircases, toilets, store cupboards, hired sports courts and rooms plus many more. Figure 1 PCTDS3 Figure 2 Typical wiring example and dimensions (in millimetres) 2 PCTDS3

Electrical Requirements Before attempting to install the unit, ensure that the intended load and wiring arrangement comply with the following requirements. Figure 2 shows a typical wiring example. 3-wire (live/neutral + volt-free switch) connection: The unit requires a permanent live/neutral connection, and as such is not suitable for replacing an existing light switch with no neutral conductor at the switch location. A volt-free relay output is provided, which can be used to switch a load on the same mains supply (by connecting across from L to LIVE IN, making LIVE OUT a switched live), or to provide a contact closure to a separate load or control signal. There is no minimum load requirement. Also available: PCTDS2 (2-wire version) Suitable for inline connection with the load to be switched (no neutral required), such as to replace a standard light switch. A minimum load of 20W (per switch unit) applies; a load capacitor is required for smaller loads. Maximum load: The maximum load rating is 16A (4000W), however for high inrush loads (such as most types of lighting), a lower limit applies: see Technical Specification. Installation All electrical installation and maintenance must be carried out by a competent person. If in doubt, consult a qualified electrician. Any new wiring must be carried out by qualified personnel in accordance with the current edition of the IET Wiring Regulations (BS7671). Ensure the electrical supply is isolated before making any connections or adjustments. 1. Prepare a single-gang pattress or back box as necessary. 2. Rotate the Timeout thumbwheel (referring to the accompanying label) to set the period of time for which the load should remain switched on after the pull cord is operated. 3. Connect the wiring as shown in Figure 2 (or in any suitably appropriate form). Supply connections (L, N): Use appropriate mains cable to power the unit. If the load is also powered via this wiring, ensure the current rating is adequate. Otherwise (i.e. if the output is independently powered), low-current cable may be used. Load connections (LIVE IN, LIVE OUT): Use cable rated for the load current and voltage. Slave switch connections (V+, R+, R-) if required: Low-current cable may be used but must be rated for mains voltages. See Using Multiple Switches for wiring details and slave switch options. 4. Fix the unit into position with the two screws and caps supplied. Additional Guidelines The screw caps may be removed at a later date with the aid of an adhesive putty such as Blu-Tack. 3

Operation The diagram below illustrates the sequence of operation for the unit. Sequence of Operation Key 4 PCTDS3

Using Multiple Switches To allow the connected load to be controlled from more than one location, multiple switches may be connected, either in parallel, or using lower cost slave switches connected to a single master switch. The following wiring examples are intended only as recommendations. Proper wiring practice must be observed with relevance to the particular installation. Example 1: Parallel Wiring Figure 3 illustrates a typical wiring arrangement using two PCTDS3 units; Figure 4 represents the same configuration as applied to a typical ceiling rose lighting circuit. This method can typically reuse pre-existing wiring from a 2-way switching installation where 3-core cable has been run between the switch locations. Each unit operates its own timing cycle, but the load is shared. When either unit (or both) is activated by its respective pull cord, the load will switch on. Once both units have timed out, the load will switch off. Note that when pulling and holding the cord to cancel the timeout, the load will remain powered if the other unit is still in the ON state. For full control from any switch location, see Example 2. Figure 3 Typical wiring schematic for two units Figure 4 Typical ceiling rose plan 5

Example 2: Master with Slave Units The remote interface feature offers the option of lower cost 2-way or multi-way switching by connecting up to five slave switches to a single PCTDS3 master unit. Unlike parallel wiring (Example 1), this method retains full control from any switch location, and does not increase the minimum load requirement. The master unit controls the timing cycle and switches the load, and any of the slave switches will function identically to that on the master unit. Each slave switch may be either a PCTDS-S slave unit (which provides an identical pull cord) or an ordinary normally-open mechanical switch (such as a pushbutton or retractive rocker). Referring to the steps under Installation, connect as follows. PCTDS-S and other switches: Use 2-core mains-rated cable to connect to the R+ and R- terminals only (polarity does not matter); do not use the V+ terminal. Figure 5 illustrates a typical wiring example using two PCTDS-S slave units; Figure 6 represents the same configuration as applied to a typical ceiling rose lighting circuit. The slave switch connections are referenced to the mains supply of the unit, and are therefore not safe to touch when the unit is powered. All switches and cables must be rated for mains voltages. Figure 5 Typical wiring schematic using two PCTDS-S slave units Figure 6 Typical ceiling rose plan using two PCTDS-S slave units 6 PCTDS3

Fault Finding Ensure the electrical supply to the unit is isolated before making any adjustments. Load will not switch on a) Unit is not powered Ensure the unit is correctly connected to an active mains supply. b) Load is not connected correctly Ensure the load is connected appropriately. The relay output is volt-free so must be connected suitably to a supply in order to power a load. Check that the load works on its own by bypassing the time delay switch. Load switches on, but does not switch off Ensure the set period has elapsed since the pull cord was last operated. Technical Specification Power supply Output switch type Output switch rating Maximum lighting load Time delay selection Mounting hardware Operating temperature Guarantee Weight Dimensions 220V - 240V AC 50Hz (live/neutral) Volt-free SPST (normally open) relay 16A, 250V AC (resistive) Incandescent: 12A (3000W) Fluorescent: 10A (2500W) Compact Fluorescent: 10A (2500W) 3 seconds to 30 minutes or 6 seconds to 60 minutes or 12 seconds to 120 minutes 28mm (min.) single-gang UK pattress box -10 C to +40 C 5 Years 98g 86mm x 86mm x 47mm 7

Technical Support For further help or information on this and other products in the MS Electronics range visit www. or call 0333 666 1176. Alternatively, email techsupport@ Additional copies of this product guide can be downloaded from our website. Product Warranty MS Electronics guarantees all their products against manufacturing defects for 5 years from the purchase date. If your product is found to be faulty, MS Electronics will, at their discretion, repair or replace the product free of charge. Note Any modification or damage to the product including damage due to abuse or incorrect wiring may invalidate the guarantee. energy saving controls e: info@ t: 0333 666 1176 f: 0333 666 1436 Follow us on twitter: @mselec MS Electronics reserves the right to change this specification without prior notice.