Conitel ASYNC Adapter

Similar documents
SCADA Point-to-Point Multiplexer

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

Multi-Port Controller

SCADA Multidrop Multiplexer

SPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

Data Broadcast Switch

SRX Frame Relay TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...4 SECTION 3 - INSTALLATION...6

SRX Multidrop TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...4 SECTION 3 - INSTALLATION...6

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

SPL - DS TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

COPPER-T EXTENDER TABLE OF CONTENTS SECTION 1 - DESCRIPTION SECTION 2 - SPECIFICATIONS... SECTION 3 - INSTALLATION

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

BT-1 TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4 SECTION 4 - OPERATION...

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

DATA CONNECT ENTERPRISE

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

DATA CONNECT ENTERPRISE

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

MEC-COM-M154. User s Manual

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

ZM24x Quick-Connect Industrial Modem. User s Manual

DSU 5600 Data Service Unit USER MANUAL

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

F280XD Fiber-Optic RS-232 Modem Technical Manual

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000

B Polling Interface

Low Speed Modems for Dial and Leased Circuits 2400E (Standalone) 2400R (Rackmount)

T1K MODBUS Base Controller Specifications

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

An ISO-9001 Certified Company

XC300 VDSL Network Extender Owners Manual

USER MANUAL. MODEL 1082 and 1082/144 idsl Modem with V.35 or X.21 Interface. An ISO-9001 Certified Company

IMS-9000 Intelligent Modem Switch USER S MANUAL. Document Part #: RDC-HDWIMS9K100

ME758C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: DB25 RJ45 CONN. INTERFACE MODULE (REAR CARD)

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

ADAM Fiber Optic to RS-232/422/485 Converter

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Models: TD3000 Series. Table Displays. 2 by 20 character display USER MANUAL

USER MANUAL. MODEL 2500 Series. Models 2500, 2510, 2520 All-Rate CSU/DSU SALES OFFICE (301) TECHNICAL SUPPORT (301)

ME500A BLACK BOX SPECIFICATIONS: BOTTOM OF UNIT INTRODUCTION: CONFIGURATION: Async Sync Industrial Line Driver PWR TX RX RTS CD. DB25 Female Conn.

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

TABLE OF CONTENTS. Introduction Operation Notes Installation Front Panel Layout Front Panel Function Description...

MEC-COM-M114. User s Manual

Miniature Asynchronous 4-Wire High Speed Modems

USER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

M82xxD Fiber Optic RS-232 MicroModem Technical Manual

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

Models: LD9000 Series. Customer Displays. 2 by 20 character display USER MANUAL

Xtreme/104. PC/104 Serial Communications. User Manual

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA

F271XA Fiber-Optic Telephone Modem Technical Manual

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

NPort 6600 Series Quick Installation Guide

RS-422 Code-Operated Switches

ANC Series RS-422 Serial Communications Adapter

F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual

Enhanced Mini-Chansim Model VCS-232

Enclosure TS-530 User Manual

The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual

EtherSeries Modbus Gateway EMB-2 User s Guide

SeaLINK+16.VC User Manual Part Number 2167

4x4 DVI Dual Link Matrix

ET100/NRZ. Ethernet WAN Bridge. 10/100Base-TX Ethernet over NRZ

DGH A3000 Configuration Guide For use with DGH Modules

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Bluetooth TO Serial CONVERTER E-P132-B

OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

Interface Converter. Installation Manual IC485S IC485SGB IC485SEU. RS-232 to RS-485/422 Serial Interface Converter

RCS/6000. Hardware. Manual

4X1 Switcher For 1.3. Model # HDMI-SW-4X1 USER MANUAL.

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

Sender Receiver Sender

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

SeaLINK+4.SC User Manual Item Number 2423

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Notice! TC Communications, Inc Cartwright Road - Irvine, CA 92614

F2MC MB90385 series Evaluation Board Documentation. Revision Date Comment V New document

Enterprise Call Manager

SeaLINK+8/USB. Sealevel Systems, Inc P.O. Box 830 Liberty, SC USA. Phone: (864) FAX: (864)

ICP PANEL-TEC PEX3000 II

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

AB300-Series Automated Filter Wheels

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

Transcription:

Conitel ASYNC Adapter TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS... SECTION - INSTALLATION...6 SECTION - CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...11 SECTION 6 - INTERFACE SIGNALS AND CABLING...16 SECTION - TROUBLESHOOTING...21 SECTION - WARRANTY...22 Data Comm for Business, Inc. PO Box 629 Champaign, IL 6126-629 July 16, 201 (21) 9-6600 Firmware Version: 1. www.dcbnet.com 0010

1. DESCRIPTION The DCB Conitel Async Adapter (CAA) converts 2 bit Conitel SCADA protocol to asynchronous data. The CAA converts each 2-bit protocol word into an ASCII, byte oriented protocol. The CAA allows migration of Conitel SCADA from the ever more expensive and hard to order analog phone lines to digital asynchronous data circuits, including DDS, radio links, or Ethernet/IP networks using the DCB EtherPath or EtherPoll. The Conitel Async Adapter can be used in conjunction with the DCB 202T modem for connection to RTU devices with built in modems. The transmit output of the 202T can be set to 16 dbm for connection to built in modems that are sensitive to high receive levels. The data port can be configured for speeds from 1200 to,600 bps. Network speeds may be as high as.6 Kbps asynchonous or 12 Kbps synchronous. The unit is configured using a network management port and an asynchronous terminal or PC with terminal emulation software. Configuration information is kept in non-volatile memory. Some features of the CAA include: Monitor functions allow network management port user to monitor transmit or receive of any data port. Many test features allow diagnostics of the system and communications link. Power supplies available for 120 VAC, and 20 VAC. DC power options available. Built-in 6 or 6Kbps DSU/CSU option available. Rack mount options available. 2

TXD RXD RTS CTS DCD TEST Conitel ASYNC Adapter DCB Network Network Switches DSU Telco Power Management Port Composite 1 CAA shown with optional built-in DSU/CSU

2. SPECIFICATIONS 2.1 Data Port Port Speeds Asynchronous only 1200, 200, 00, 9600, 19,200,,00, or,600 bps Port Rate Selection Selected through network management port control with an asynchronous terminal. Data Format 2 bit Conitel 2020 Interface CCITT V.2, RS-22D, implemented in RJ-, position connectors. (RS-61 standard physical pin-out used on RJ- connectors) Buffering 2K dynamically allocated Data Delay DCD to RX data delay [-20 ms] DCD holdover delay [2-20 ms] 2.2 Composite Port Full Duplex Speed Synchronous up to 12 Kbps Asynchronous from 200 to,600 bps Interface RS-22D, implemented in RJ-, position connector 2. Physical / Electrical 10¼" W x 9¾" D x 2½" H 120 VAC external power supply Optional DC and 20VAC power supplies available 0 watts,.2 amps

2. Environmental Operation: -0 to +0 C, 10 to 9% relative humidity Storage: -0 to + C, 10 to 9% relative humidity 2. Network Management Port Commands Show Port Configuration Show Network Status Change Port Configuration Change Data Delay Configure Network Show / Change ID Set NMP Password Activity Counters Zero Activity Counters Test Tools Monitor Port Tx Monitor Port Rx NMP Parity Ping Remote Unit Reset Unit Type Repeat Last Command Disconnect NMP 2.6 Other Specifications Front Panel Indicators Power Activity Line Error Modem Ready Front Panel Switches Reset 2. Optional Built-In DSU/CSU Specifications Compatible with Common Carrier digital signalling 6 or 6 Kbps wire digital line Can be used as high speed wire line driver in 6K mode

. INSTALLATION.1 Unpacking Remove the unit from the shipping container and examine it carefully for external damage. If shipping damage is apparent, notify the shipper immediately. The following accessories are included with the unit: external power supply manual warranty, maintenance contract and repair information Modem to Composite cable (black) for connecting the unit to an external modem or DSU/CSU Network Management Port cable (green) for connecting the network management port to an asynchronous terminal or PC for configuration If your unit has the optional built-in DSU/CSU, a cable is also included for connection to the phone line..2 Setup The composite port must be configured properly for the type of link used (Sync or Async). In addition, the data port must have the proper speed setting. This is done using the network management port CN and CP commands (see Section ).. Using Leased Line Modems In this section, a reference to modem includes modems, digital radios or DSU/CSUs for leased line installations. Connect the modems to the phone line and power ON the modems. Confirm the presence of carrier at each modem. If carrier is not detected at both ends, recheck the option settings. If carrier is still not present, check the cable from the telephone line to the modem. If everything is correct and still no carrier call the manufacturer of the modem or contact the telephone company for assistance. Connect the CAA composite port to the modem. A two foot RJ to DB- 2 male cable connects the composite port of the CAA (the RJ connector second from the left when viewed from the rear) to the data port of the modem (usually a DB-2 female connector). See Section 6 for cabling information. 6

Connect the unit to power. Power and Modem Ready indicators on the front panel of the CAA must be ON indicating the on-line condition. (See Section ).. Optional Built-In 6 or 6 Kbps DSU/CSU The optional DSU/CSU is configured using DIP switches accessable from the rear of the unit. See Section for a description and location of these switches. The default settings should be correct for most applications. For line driver applications over customer owned wire (6K only), set one unit for Master Clock and the other unit to Slave Clock.. Cabling Cabling between the unit and the computer ports or terminal devices is a common source of installation problems. The CAA must have data from attached terminal devices or computer ports, as an input on Position 6 of the RJ connector. Data from the CAA to any attached equipment will be transmitted on position of the RJ connector. See paragraph 6.1 for position location on the RJ connector. See Section 6 to determine the correct cables for your computer and terminal devices.

.6 Resetting Factory Defaults The factory default settings for the CAA are as follows: Data Port: Rate 1200 bps DCD to RxD delay ms DCD holdover 12ms Composite Port: Modem type Rate ASYNC 9600 bps To reset the unit to factory defauls use the!r command from the network management port or perform the following steps using the front panel switches: 1. Depress and hold the SETUP switch while depressing the RESET switch. 2. Be sure to continue to hold the SETUP switch until the unit completes the reset and the lights return to normal.. All settings should be at the factory defaults. Use the SC (Show Configuration) command to check the port settings.

. CONTROLS AND INDICATORS.1 Switches TXD RXD RTS CTS DCD TEST DCB.1.1 Front Panel Switches (shown with built-in DSU) Setup Used in conjunction with Reset to recall factory default settings Loopback Disabled. Reset Performs a hardware reset of the unit..1.2 Optional Built-In DSU Switches The DSU switches are located at the rear of the unit. Switch functions are shown in the following table: Switch Down Up 1 6K 6K (optional) 2 Slave Clock Master Clock Must Be Down RTS Normal RTS Forced ON Normal Local Loop ON 6 Not Used NOTE RTS mode (sw ) is active in 6Kbps mode only. In 6Kbps mode, RTS is forced on. Network Network Switches DSU Telco Power Management Port Composite 1 9

For normal operation with a telephone company line, set the DSU for SLAVE clock timing (switch position 2 DOWN). For in-house line driver applications (6K only), set the host DSU for MASTER timing (switch position 2 UP). The remote unit should remain set for Slave clock..2 Indicators POWER ON when the CAA is connected to power. ACTIVITY OFF no data activity. ON data is being transmitted. LINE ERROR flashes when a network error is detected. MODEM READY ON Data Carrier Detect is present from the composite link device indicating an active composite link. OFF Data Carrier Detect is not present from the composite modem or DSU/CSU indicating a problem with the composite link. PORT 1 SETUP Disabled LOOPBACK Disabled. Optional DSU/CSU Indicators TxD Flashing Data is being sent over the link. RxD Flashing Data is being received from the link. RTS ON OFF Forced on or high from the multiplexer. No RTS from the multiplexer. CTS Follows RTS CTS signal to the multiplexer. DCD TEST ON OFF ON Flashing Normal condition. No carrier signal received from the far end. Unit is in loopback (DIP switch UP) Telephone line in loopback. 10

. NETWORK MANAGEMENT PORT.1 Introduction The Network Management port (NMP) is used to configure the unit for proper operation. This connection must be used to configure the CAA composite and data ports. The NMP can also be used to configure remote CAA parameters after a link is established between the host and remote sites..2 Connections and Setup Connection to the NMP is made either through a port on the rear of the unit..2.1 Dedicated Terminal or PC The NMP functions are also available through a port on the rear of the unit labeled Network Management Port. To connect a dedicated terminal to this port, use the green cable provided and the appropriate adapter for either a terminal or PC. Set the terminal device for 9600 bps, data bits, no parity, one stop bit and no flow control..2.2 Dedicated Modem For remote access to NMP functions, a dial-up modem may be connected to the Network Management Port. You must fix the DTE interface speed of the modem at 9600 bps, data bits, no parity and one stop bit. Refer to your modem manual for appropriate setup procedures. Use the appropriate cable from paragraph 6.. for connection. 11

. Using the Network Management port To activate the NMP, press the ENTER key. When you see AT YOUR COMMAND >>, the NMP is active and ready for your commands. Type H <Enter> to display the command set.. Commands..1 Help (H or?) COMMAND LOCAL REMOTE PARAGRAPH Show: Config SC RSC..2 Network SN.. Change: Port Config CP RCP.. Data Delay CD RCD.. Config Network CN..6 Set ID ID RID.. Set Password PW.. Activity Counters/Zero AC/Z RAC/RZ..9 Test Tools TT..1 Type TY RTY..10 Repeat Last Command *..11 Disconnect NMP BYE..12 This Help screen shows the choice of commands available. The commands allow you to display the selected options (Show network and configuration), configure the CAA (Configure ports and Set ID), and perform many different diagnostic functions such as send a test message, monitor data, perform loopbacks, show flow control state, show activity and other useful tests...2 Show (Port) Configuration The Show Config (SC) command shows the current port configuration settings for either the local or the remote (RSC) ports. Port numbers may be included with this command to limit the display range. If no port numbers are included, settings for all ports are shown. Use this command to verify proper port configuration... Show Network (Configuration) The Show Network (SN) command displays the current network (composite port) configuration (SYNC or ASYNC). 12

NOTE Several commands allow port numbers or port number ranges to be included on the command line. When port numbers are included, the syntax is as follows: (Command)1 Port 1 (Command)1,2, Ports 1, 2 & (Command)1 Ports 1, & (Command)2 Ports 2 thru.. Change Port Configuration The Change Port Config (CP / RCP) command sets the data port rate configuration. Follow the prompts on the screen to select the rate. The factory default setting is 1200 bps... Change Delay Timeout This command (CD) is used to change two timeout parameters, DCD to Rx data delay (-20ms) and DCD holdover delay(2-20ms). These delays may be adjusted to insure data block integrity...6 Configure Network The Configure Network command (CN) allows configuration of the composite port for asynchronous or synchronous operation and to enable or disable remote commands. Disabling remote commands will increase throughput but you will no longer be able to manage the far end CAA remotely... Set ID The Set ID (ID / RID) command allows you to set or change either the local or remote unit identifier. IDs can be a maximum of 1 characters in length. Pressing <Enter> with no entry will leave the ID unchanged. 1

.. Set Password Use the Set Password (PW) command to set a password for access to the network management port. The password may be up to 1 characters long and is case sensitive. To clear the password, type DELETE at the PW prompt or reset the unit to defaults as described in paragraph.6...9 Activity Counts / Zero The Activity Counts (AC / RAC) command shows transmit and receive data statistics for all ports. The data are presented in terms of blocks of information sent and received by the network and each data port. Error counts are also shown. A range of ports may be included with this command to reduce the number of ports shown. The Z and RZ commands are used to zero the counters so that current activity can be monitored...10 Type The Type (TY) command displays information about the local unit including firmware version, number of ports and CAA ID. The Remote Type (RTY) command is used to display similar information about the remote unit...11 Repeat Last Command To repeat the last command, simply press the * key. This is handy for repeating screens of constantly changing data...12 Disconnect NMP The BYE command toggles the CTS output from the Network Management port. This is used to disconnect equipment such as dialup modems or the DCB Access Switch. 1

..1 Test Tools The Test Tools (TT) menu summarizes the test and troubleshooting commands. These commands are listed separately to reduce the clutter in the main help list, but are always available from the command prompt. COMMAND LOCAL REMOTE PARAGRAPH Monitor Port Tx MT..1 Monitor Port Rx MR..1 NMP Parity P..1 Ping Remote Mux PING..16 Reset CAA RESET RRESET..1..1 Monitor Port TX or RX The Monitor Port TX (MT) command monitors data transmitted from the data port of the local unit to the data port of the remote unit. The Monitor Port RX (MR) command monitors data received by the data port of the local unit from the data port of the remote unit. When port monitor is active, two ESC characters are needed to end the test...1 NMP Parity The NMP Parity command (P) sets the parity for the network management port. The factory default is SPACE (,N,1)...16 Ping Remote Mux The PING command pings the remote CAA and displays the response time in milliseconds...1 Reset CAA The Reset CAA (RESET) command performs a local unit reset. To reset the remote unit use RRESET. 1

6. INTERFACE SIGNALS AND CABLING 6.1 Connector Location and Pin Reference Network Network Power Management Port Composite Switches DSU Telco 1 1 2 6 CAA Rear Panel and RJ- Jacks RJ- Plug Positions 16

6.2 Port Interface 6.2.1 Composite Port (RJ-) Pin Signal In/Out 1 Receive Clock IN 2 Transmit Clock IN Data Carrier Detect IN Signal Ground Transmit Data OUT 6 Receive Data IN Request to Send OUT Clear to Send IN 6.2.2 Data Port (Conitel In, RJ-) Pin Signal In/Out 1 Data Set Ready OUT 2 Data Carrier Detect OUT Busy IN Signal Ground Receive Data OUT 6 Transmit Data IN Clear to Send OUT Request to Send IN 6.2. Network Management Port (RJ-) Pin Signal In/Out 1 Not Used 2 Not Used Data Carrier Detect IN Signal Ground Transmit Data OUT 6 Receive Data IN Request to Send OUT Clear to Send IN 6.2. Optional Built-In DSU Interface (RJ-S) Pin Signal In/Out 1 Transmit Data OUT 2 Transmit Data OUT Receive Data IN Receive Data IN 1

6. Cables 6..1 Composite Port to Modem A two foot composite to modem cable is included with each unit. The configuration is as follows: CAA RJ- 1 2 6 Modem DB-2P 1 1 2 20 6..2 Data Port to Host Computer Configured as DTE CAA RJ- 1 2 6 Computer DB-2 6 20 2 (or other flow control output pin) (or other flow control input pin) (or 20 if is flow control) 1

6..2 Data Port to Host Computer, continued Configured as DCE CAA RJ- Computer DB-2 1 2 6 20 2 (or if 20 is flow control) (or other flow control output pin) (or other flow control input pin) To a PC CAA Computer RJ- DB-2S DE-9S 1 2 6 6 or 6 or 1 or or or 2 2 or or 20 or 19

6.. Network Management Port To a TERMINAL NMP RJ- 6 Terminal DB-2P 20 2 6 To a PC using terminal emulation NMP Computer RJ- DE-9S DB-2S 6 or 20 or 2 or or 2 or 6 or 6 1 or or To a dial-up MODEM for remote access NMP RJ- 6 Modem DB-2P 2 20 20

. TROUBLESHOOTING.1 General Approach When troubleshooting problems, a rational plan can save you many hours of frustration. The following is a brief outline of standard troubleshooting procedures. 1. Gather the facts to determine the exact nature of the problem. 2. Draw a picture of the system showing the equipment at both the host and remote ends and the phone lines or in-house wiring. Use this as a reference to note your observations, test steps and test results. A picture keeps you focused and often saves duplicate effort.. Record the front panel indications before changing anything. This is an important part of fact gathering. If you change anything, change only one thing at a time.. Use the built-in test functions, and record your results..2 Installation Troubleshooting, Modems or DSUs First, set up the Modems or DSUs without connecting the units. If DSUs are used they should be set to constant carrier, also called forced Request To Send, or constant RTS. Carrier Detect should be ON at both locations.. Assistance If you need assistance troubleshooting your system, contact DCB customer support at (21) 9-6600 between :00 am and :00 pm central time Monday through Friday. 21

. WARRANTY DCB products are warranted to be free of defects in materials and workmanship for two years. Data Comm for Business will repair or replace any equipment proven to be defective within the warranty period. All warranty work is F.O.B. Dewey, IL. This warranty is exclusive of abuse, misuse, accidental damage, acts of God or consequential damages, etc. DCB liability shall not exceed the original purchase price. All equipment returned for repair must be accompanied by a Returned Material Authorization (RMA) number. To receive an RMA number, call (21) 9-6600 between the hours of AM and PM central time. Equipment must be shipped prepaid to DCB and will be returned at DCB's expense. Ship returned items to: Data Comm for Business 299 County Road 1000E Dewey, IL 610 ATTN: RMA# Data Comm for Business, Inc. PO Box 629 Champaign, IL 6126-629 Tel (21) 9-6600 Fax (21) 9-11 Email support@dcbnet.com 22