OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

Similar documents
Model Number: DZ300-12EU

REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES

Series: DZ100 Universal AC to 100W Power Bricks

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MODEL 805 USER MANUAL

Innovative Circuit Technology Ltd.

PS8 - II. Professional Power Sequencer. User s Manual

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

U-150 Integrated Amplifier User s guide

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

User's Guide. Model High Precision Quad Output DC Power Supply

1-36V, 0-3A DC Power Supply

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

iconverter 2-Module Power Chassis

User s Guide. 600A AC Clamp Meter. Model 38387

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

EPS Power Supply

EOS-6000 Series Optical A/B Switch User Manual DC Version

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Laboratory Switch Mode Power Supply Series. Instruction Manual

APT20. User Manual.

User Guide. Single-Link DVI Fiber Optic Extender DVI-7315

DC-AC Inverter Pure Sine Wave 120 Watt. Please read this manual before installing your Inverter. Manual PST

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

CVH Slot Media Converter Chassis Quick Installation Guide

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

USB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

IMS-9000 Intelligent Modem Switch USER S MANUAL. Document Part #: RDC-HDWIMS9K100

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

HRS-1S. Half Rack Analog Stereo Audio Speaker Monitor. User Guide. Part Number , Revision E

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

PS-20. Power Supply. User Manual Rev F

Dual Link DVI Extender

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

Flat. PIFN-C072B Flat 75W LED Driver. Features. Electrical Specifications. Input Specifications 1 / 8 18V - 23V / 2.00A - 3.

120 WATT FLEX ATX TYPE WITH ACTIVE PFC

Summit Virtual Chassis Design and Installation Guide

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

87421/22A Power Supply. Operating and Service Manual

PS2328 Integrated Power. System

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

User's Guide. Extech AM A AC Analog Clamp Meter

EFRP-x462 SERIES. Industrial Computer File Server System Raid Subsystem

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

DS-1H05 Ethernet-over-Coax Extender. User Manual

Flat. PITK-W025B Flat 23W LED Driver. Features. Specification Summary. Input Specifications 1 / V / 0.57A / 23W. Mechanical Outline

F280XD Fiber-Optic RS-232 Modem Technical Manual

CMSA-100 Manual. Cinema Media Server Automation

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

Innovative Circuit Technology Ltd.

Line Impedance Stabilization Network (LISN)

MODEL No. SW1X8 RS422 SWITCHER

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

1:4 3GSDI Splitter. User Manual EXT-3GSDI-144. Release A5

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

OWNER S MANUAL CD-2 V 1.3

DVI Detective. User Manual EXT-DVI-EDIDN. Release A3

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

POWER ISOLATION PRODUCTS BIT-5 BIT-15 BIT-20

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

PS 680 SIX CHANNEL POWER SUPPLY WITH AUX MATRIX USER MANUAL

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

DVI ELR Extender over one CAT5

Installation Instructions Model LFMWLT450, Class 1 Series AC-DC Power Supply

ZEPHYR Compact Haze Machine

HDMI to 3GSDI Converter

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

MC 11 EB-2 Power supply cabinet with external bus, AC version

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

High Power over Ethernet Midspans PD Port Model PD Port Model

Cantata m100 Amplifier

M82xxD Fiber Optic RS-232 MicroModem Technical Manual

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

PR3400 Series 1.4Mp USB Cameras Hardware Guide

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Applications Electronic Design/Development Battery Charging Launch Control Rackmount ATE Systems. DLM 600 Near Linear 600W DC Power Supply

User Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series

Voltage Current Front-mounting bracket

The PST-6. Owners Manual 1

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

Transcription:

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR065-48S / OPR065-48R Manual Revision F July 2009 Optimal Power Supplies LLC www.optimal-power.com i

PROPRIETARY DATA All data in this manual is proprietary and may not be disclosed, duplicated or used for procurement or manufacturing purposes, without prior written permission by OPTIMAL POWER SUPPLIES LLC LIABILITY DO NOT OPERATE OR SERVICE THE OPR065-48S & OPR065-48R MODELS WITHOUT READING THIS ENTIRE MANUAL FIRST Optimal Power Supplies LLC is not responsible for any kinds of damages sustained through the use of this or any other Optimal Power Supplies LLC products. It is entirely the customer s responsibility to take all the necessary precautionary measures when installing this unit. In the interest of improving internal design, operational function, and/or reliability, Optimal Power Supplies LLC reserves the right to make changes to the products described in this document without notice. WARRANTY Optimal Power warrants all of its products against defects in materials and workmanship for one year from date of delivery. We will repair, or replace parts which prove to be defective during the warranty period provided that: 1. A Return Maintenance Authorization (RMA) is obtained from OPTIMAL POWER at (251) 209-8088 or www.optimal-power.com. Please reference your RMA number on the outside of the box the item is shipped in. 2. Shipping charges are pre-paid by customer Optimal Power does not endorse any other warranty, expressed or implied, and is not liable for consequential damages. Products that are damaged, opened, or modified do not qualify for a warranty. The same procedures must be followed for repairs outside the warranty period. ii

CHAPTER TITLE PAGE 1 OPR Power Series Introduction... 1 1.1 Product Description 1 1.2 Main Features. 1 1.3 General OPR Power Series Specifications. 2 1.4 Typical Safety Rating. 2 2 OPR065-48S / OPR065-48R 3 2.1 OPR065-48S / OPR065-48R Description.. 3 2.2 Specifications... 3 3 Status Indicators and Back Panel Connections. 5 3.1 Back Panel DC Power Connector.. 5 3.2 Front Panel Status Indicators... 5 3.3 Remote Management DB-25 Connector Pin Out for OPR065-48S 5 3.4 Remote Management DB-25 Connector Pin Out for OPR065-48R 5 4 Alarm Systems... 6 4.1 Alarm Monitoring System.. 6 5 Installation and Maintenance... 7 5.1 Installation.. 7 5.2 Maintenance 7 5.3 Warnings... 8 5.4 Design Block Diagram..... 9 6 Images... 10 6.1 OPR065-48S (Single Power Supply)... 10 6.2 OPR065-48R (Redundant Power Supply)... 10 6.3 OPR065-48R (Front View)... 11 6.4 OPR065-48S (Front View)... 11 6.5 OPR065-48S (Rear View). 12 6.6 OPR065-48R (Rear View)... 12 6.7 DC Cable Image... 13 iii

Chapter 1 OPR Power Series - Introduction 1.1 Product Description OPR Power Series is a unique and a highly reliable power supply series. It can be configured as a single as well as a fully redundant power supply. OPR Power Series is designed for Universal AC to DC power supply applications. Because of this feature these power supplies can be used anywhere in the world. These power supplies are mainly used in the following applications: Computer Peripherals and Networking Applications Telecommunications and Fiber Optic Network Voice, Data and Analog Communications Universities and Educational Facilities Instrumentation and Electronics Utility and Power Industries Data Acquisition Medical Military OPR Power Series is a reliable, efficient and inexpensive solution for all kind of AC to DC power supply applications. 1.2 Main Features: Compact Rack Mount Size (1.75 H x 19 W x 12.12 D) Universal AC (Alternate Current) Input Filtered IEC AC Inlet Connectors Internal Power Bricks EMI FCC Class B Clearance Single and Multiple Output Highly Efficient Design 1U Low Profile Height NO Minimum Load Required Remote Management Low Voltage Power Supply Alarm Cost Effective and Reliable Power Supply Solution 1

1.3 General OPR Power Series Specifications: Input Voltage...Universal 90VAC to 264VAC Input Frequency...47Hz to 63Hz Operational Temperature. 0 C to 55 C Storage Temperature..-20 C to 85 C Cooling Cool Air Flow Overload Protection...Auto-Recovery Efficiency...80-90% Typical DC OK DB25 Interface and Status LEDs 1.4 Typical Safety Rating for Internal Power Modules: Designed in full compliance with... UL60950 CSA 22.2 No. 234 EN60950 EMI.....EN55022 Class B EMS EN61000-4-2,-3,-4,-5,-6,-8,-11 Harmonics.....EN61000-3-2 Class D Redundant Power Supply 2

Chapter 2 OPR065-48S / OPR065-48R 2.1 OPR065-48S / OPR065-48R Description: The Models OPR065-48S and OPR065-48R are 1U rack mountable power supplies designed to operate in single and redundant power configurations respectively. OPR065-48S has one built-in universal AC to 48V DC power supply, and OPR065-48R has two built-in universal AC to 48V DC power supplies with two IEC AC plugs for complete redundancy. OPR065-48S provides up to 65W of power, and OPR065-48R provides up to 130W of redundant power* to the system that each is attached. Each model has its own AC-INLET (one for OPR065-48S and two for OPR065-48R), ON/OFF switches, and power LEDs (one for OPR065-48S and two for OPR065-48R). Both models have two built-in alarm circuits with red LEDs for low DC power monitoring and for remote power management. In addition, models OPR065-48S and OPR065-48R have a DB25 interface for power supply alarm and remote Turn-OFF features. 2.2 Specifications: Electrical Output Voltage 48V DC Output Ripple Typical 200 mv Output Current 1.35A Typical Output Power 130W for OPR065-48R* 65W for OPR065-48S Input Voltage Universal 90VAC to 264VAC input (2 AC inlet plugs in OPR065-48R for complete redundancy) Input Frequency 47Hz to 63Hz Input Current 3 Amps max Current Tolerance 1% Remote Management Interface DB25 Logic Interface Note*: 130W is intended only for redundancy; it is not recommended to power a total load of 130W with the Model OPR065-48R Typical Safety Ratings for Internal Modules: Designed in full compliance with UL60950 CSA 22.2 No. 234 EN60950 EMI EN55022 Class B EMS EN61000-4-2,-3,-4,-5,-6,-8,-11 Harmonics EN61000-3-2 Class D 3

Environmental Overload Protection Auto-recovery Functional Temperature 0 to 70 C Storage Temperature -20 to 85 C Over voltage Type Latch off Efficiency 80-90% Typical Physical Dimensions 1U (1.75 H x 19 W x 12.12 D) Weight Approx. 13.25 lb = 6.01 kg = 212 oz Single Power Supply 4

3.1 Back Panel DC Power Connector Chapter 3 Status Indicators and Back Panel Connections WARNING: Observe polarity when making connection to the rear of Model OPR065-48S / Model OPR065-48R + Indicates 48 Volt DC Indicates Ground Line 3.2 Front Panel Status Indicators LED Description (When Lit) Labeled Indicators Solid Green Power Supply 1 Activated Power 1 Solid Red Power Supply Failure PS 1 Alarm Solid Green Power Supply 2 Activated Power 2 Solid Red Power Supply Failure PS 2 Alarm 3.3 Remote Management DB25 Pin-Out for OPR065-48S Pin Numbers Description I/O Direction Logic High = 1 Logic Low = 0 Pin # 2 Remote Turn ON/OFF Input Power OFF 1 Power ON Pin # 3 Power Supply Alarm +RS485Output Alarm NO-Alarm Pin # 16 Power Supply Alarm RS485 Output NO-Alarm Alarm Pin # 1 Frame Ground Output NA NA Pin # 7 Signal Ground 2 Output NA NA 3.4 Remote Management DB25 Pin-Out for OPR065-48R Pin Numbers Description I/O Direction Logic High = 1 Logic Low = 0 Pin # 3 Power Supply 1Alarm +RS485 Output Alarm NO-Alarm Pin # 16 Power Supply 1Alarm RS485 Output NO-Alarm Alarm Pin # 9 Power Supply 2Alarm RS485 Output NO-Alarm Alarm Pin # 17 Power Supply 2Alarm +RS485 Output Alarm NO-Alarm Pin # 1 Frame Ground Output NA NA Pin # 7 Signal Ground 2 Output NA NA Note 1: In order to turn OFF the power supply remotely, a voltage level of 5V@80mA current should be applied between pin 2 and pin 7. Note 2: For proper remote management interface functionality. It is important to connect the signal ground properly and securely. 5

Chapter 4 4.1 Alarm Monitoring System Alarm Systems The models OPR065-48S and OPR065-48R have the ability to monitor output DC voltage, and trigger an alarm when the output DC voltage starts to decrease below the threshold limit. The threshold limit of the system is 40V. OPR065-48S Alarm Indications If for some reason the voltages in power supply Model OPR065-48S drop below the threshold limit (due to overload, for example) the DB25 interface pin 16 will go logic LOW, and pin 3 will have logic HIGH indicating power supply failure. DB25 Pin Out Normal Condition Power Supply Failure Pin 16 (Power Supply Alarm) Pin 3 (Power Supply Alarm) Logic High = 1 Logic Low = 0 Logic Low = 0 Logic High = 1 OPR065-48R Alarm Indications If for some reason the voltages of power supply 1 in the Model OPR065-48R drop below the threshold limit (due to overload, for example) the DB25 interface pins 3 will go logic HIGH, and pin 16 will have logic LOW indicating power supply 1 failure. DB25 Pin Out Normal Condition Power Supply Failure Pin 3 (Power Supply 1 Alarm) Pin 16 (Power Supply 1 Alarm) Logic Low = 0 Logic High = 1 Logic High = 1 Logic Low = 0 Furthermore, if the voltages of power supply 2 drop below the threshold limit. The interface pin 17 will go logic HIGH, and pin 9 will have logic LOW indicating power supply 2 failure. DB25 Pin Out Normal Condition Power Supply Failure Pin 17 (Power Supply 2 Alarm) Pin 9 (Power Supply 2 Alarm) Logic Low = 0 Logic High = 1 Logic High = 1 Logic Low = 0 6

Chapter 5 Installation and Maintenance 5.1 Installation OPR065-48S and OPR065-48R may be installed in a fixed, semi-fixed and mobile environments that meet the environmental characteristics specified in Chapter 2. These models are designed to be mounted in a standard 19 equipment rack utilizing the mounting holes provided on the front of each unit. It is recommended that at least 1 rack unit (1U = 1.75 ) gap be provided above or below the OPR power supply unit for proper air flow. Once these power supplies are mounted in the rack, they should be connected to the system (that only requires 48VDC power) with the DC output connector located at the rear of the OPR unit. WARNING: Observe polarity when making connection to the rear of model OPR065-48S / OPR065-48R Next, ensure that the front panel power switch(es) are in "OFF" position. Connect the AC power cord to the unit by plugging the free end of the power cord into a standard three prong AC outlet. Ensure that the AC power plug(s) located at the rear end of the power supply are connected to a clean and well-grounded Universal AC source. OPR065-48S Setup Once all the wires are connected properly as described in the above installation paragraph: (1) Turn "ON" the front panel switch. (2) The "Power" LEDs, should light up. Now the system is ready to operate to its required purpose. OPR065-48R Setup Once all the wires are connected properly as described in the above installation paragraph: (1) Turn "ON" the front panel switch for Power supply 1 The "Power 1" green LED, and "PS 2 Alarm" red LED should light up. Indicating Power supply 1 is "ON" and Power supply 2 is "OFF" (2) Turn "ON" the front panel switch for Power supply 2 This should clear the "PS 2 Alarm" red LED and cause the "Power 2" green LED to illuminate. Now the system is ready to operate to its required purpose. 7

Monitoring AC Input and DC Output OPR Series models have switches that monitor AC current input and DC current output. Whenever the "Power" switches are "ON" the LEDs embedded in the switch should light up. These indicate good AC input. Similarly the "Power 1" (or "Power1" and "Power2" in redundant models) LEDs should turn green, indicating good DC output. Alarm Conditions for Redundant Power Supply Power 1 Failure AC plug disconnected to Power 1 Front panel Switch to Power 1 is in OFF position Power 2 Failure AC Plug disconnected to Power 2 Front panel Switch to Power 2 is in OFF position 5.2 Maintenance The Models OPR065-48S and OPR065-48R should be treated with the sufficient care. Do not use abrasives or solvents, as they may mar surfaces Do not subject the unit to excessive temperature extremes Do not subject the unit to excessive moisture or spilled liquids Do not subject the unit to sudden or severe shocks Never operate the Model OPR065-48S / OPR065-48R with any of the covers removed 5.3 Warnings To reduce the risk of fire, electric shock or product damage, DO NOT expose the OPR065-48S / OPR065-48R unit(s) to direct heat, rain, moisture, dripping or splashing. DO NOT place any object filled with any kinds of liquids on the unit(s). To prevent damage to LEDs and switches, DO NOT place the front panel of the unit face down, and/or DO NOT press against the front panel. Optimal Power is not responsible for any kinds of damages sustained through the use of this product. 8

5.4 Design Block Diagram DC OUPUT DC OUPUT OPR065-48S OPR065-48R Power Module 1 Power Module 1 Power Module 2 AC INPUT AC INPUT AC INPUT 9

Chapter 6 Images 6.1 OPR065-48S (Single Power Supply) 6.2 OPR065-48R (Redundant Power Supply) 10

6.3 OPR065-48R (Front View) Power 1 PS 1 Alarm Power 2 PS 2 Alarm 19 6.4 OPR065-48S (Front View) Power 1 PS 1 Alarm 19 11

6.5 OPR065-48S (Rear View) Three Cooling Fans DB-25 Interface Remote Management Pin 1 = Frame Ground Pin 2 = Remote ON/OFF Pin 3 = +RS485 Power Alarm Pin 7 = Signal Ground Pin 16 = RS485 Power Alarm Ground +48V AC Input Volt Power Supply 6.6 OPR065-48R (Rear View) Three Cooling Fans DB-25 Interface Ground +48V Remote Management Pin 1 = Frame Ground Pin 3 = +RS485 (Power 1 Alarm) Pin 16 = RS485 (Power 1 Alarm) Pin 17 = +RS485 (Power 2 Alarm) Pin 9 = RS485 (Power 2 Alarm) Pin 7 = Signal Ground AC Input Volt Power Supply 2 AC Input Volt Power Supply 1 12

6.7 DC Cable Image 16 AWG Wire Required Black = Negative Lead = 0V Red = Positive Lead = 48V Important Note* For proper current flow make sure to connect all the specified power terminals * WARNING: Observe polarity when making connection to the rear of Model OPR065-48S / Model OPR065-48R + Indicates 48 Volt DC Indicates Ground Line 13