MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

Similar documents
MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: 40DN. Digital Panel Meters 40 Series

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: 43AL1. Digital Panel Meters 43 Series

MODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: GR8-EM. Communication Adaptor GR8 Series

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 43DV2. Digital Panel Meters 43 Series

MODEL: WL40EW2F. Wireless I/O WL40F Series

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MODEL: CND. Multiplex Transmission System

SensoTrans DMS A 20220

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS

MODEL: M8BS-16. [3] OPTIONS blank: none /Q: With options (specify the specification)

MODEL: W2XR SEN TRONIC AG. Mini-MW Series

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Preset counters, electromechanical

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

Compact Inductive Proximity Sensor

Signal Doublers. VariTrans A 20300

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

MINI MCR-SL-UI-REL(-SP)

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Zelio Control-modular measurement and control relays 1

For Super-mini Signal Conditioners with Display M1E-UNIT USERS MANUAL

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

CJ1W-PTS/PDC/PH41U/AD04U

DINALOG A 144 x 36 A1400 Light-Strip Indicator

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Solving your relay requirements since 1922

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

E4PA. Ultrasonic Displacement Sensor. Ordering Information

Model Number Structure

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

Switching Power Supply

PI-EX-ME-2NAM/COC-24VDC

MINI MCR-SL-UI-2I(-SP)(-NC)

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Process displays For current and voltage

Displays Transducers. Displays and transducers

Safety Relay Unit (I/O Unit Type)

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Zelio Control - modular measurement and control relays 1 Speed control relays RM35 S

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Compact high capacity, (25A max) Slim heat sink combined type added

MIC-2 MKII, Multi-instrument DATA SHEET

Model Number Structure

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

PHOENIX CONTACT - 12/2007

Inductive Proximity Sensor

PI-EX-ME-2NAM/COC-120VAC

Solid State Remote Power Controller E /627

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

MODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8

Model Number Structure

Thread length (overall length) material

NTSC TOA's Digital Video Recorder series combine high reliability with all the advantages of scalable expansion flexibility.

Temperature Switches

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

ECT Signal Isolator/Converter

Compact high capacity, (25A max) Slim heat sink combined type added

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

2 Channel Super-mini Signal Conditioners with Display M1E Series POTENTIOMETER TRANSMITTER (2 channels, PC programmable) Functions & Features Potentiometer s zero/span points can be captured by onsite calibrations 2 channels Adjustments with the front button OEL display with good visibility Linearization available for each channel (111 points) Typical Applications Tank levels Positions: Compensating non-linear signal from the linking mechanism of a position detector 36 (1.42) OUTPUT Field-selectable DC Output Current output: 0-20 DC oltage output: -5-5 DC oltage output: -10-10 DC [1] POWER INPUT AC Power M2: 100 240 AC (Operational voltage range 85 264, 47 66 Hz) DC Power R: 24 DC (Operational voltage range 24 ±10 %, ripple 10 %p-p max.) P: 110 DC (Operational voltage range 85 150, ripple 10 %p-p max.) [2] OPTIONS blank: none /Q: With options (specify the specification) 125 (4.92) 99 (3.90) mm (inch) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-5983) Note: The figure shows the combination of the unit and the base. MODEL: M1EXM-2[1][2] ORDERING INFORMATION Code number: M1EXM-2-[1][2] Specify a code from below for each [1] and [2]. (e.g. M1EXM-2-M2/Q) Specify the specification for option code /Q (e.g. /C01/SET) NO. OF CHANNELS 2: 2 channels INPUT Total resistance 100 Ω 10 kω RELATED PRODUCTS Installation base (model: M1E-BS1) M1E configurator software (model: M1ECFG) Downloadable at M-System s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual (EM-5981) for the M1E configurator for applicable cable types. GENERAL SPECIFICATIONS Construction: Plug-in Connection Connected to base with connector Base M2.6 screw terminals (torque: 0.5 N m) Applicable solderless terminal size (M3) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (black) : Ch1.input to ch2.input to Ch1.output to ch2.output to power Overrange output: Approx. -5 to 105 % (Not available for M1EXM SPECIFICATIONS ES-5983 Rev.0 Page 1/7

current output not greater than 0 ) Output zero fine adj. range: -5 to 5% (front button) Output span fine adj. range: 95 to 105% (front button) Configuration: Program with front buttons or ia PC. Programmable features include: Refer to the parameter list. Configurator connection: 2.5 dia. miniature jack; RS-232-C level Recommended solderless terminal size - M3 (unit: mm) 3max 6max 4min 12max 3.2 dia. (mm) DISPLAY Display functions: Displays and sets measured range, engineering unit Display size: Approx. 15.6 20.8 mm (0.61 0.82 ) Number of pixels: 68 95 (horizontal vertical) Character color: Yellow Display life: Approx. 50000 hours (Expected time for the Display brightness to be reduced to 50 % when the Display is used continuously with brightness setting 2 in 25 ) Display type: OEL display Display digit: Negative 5 digits, positive 6 digits (-99999 to 999999) Decimal point position: Selectable INPUT SPECIFICATIONS Minimum span: 5 % of total resistance Excitation: Approx. 0.5 DC OUTPUT SPECIFICATIONS DC Current Output range: 0 20 DC Conformance range: 0 21 DC Minimum span: 1 Load resistance: Output drive 15 max. (e.g. 4 20 : 750 Ω [15 20 ]) (Not available to output less than 0, output range may not be extended to -5 %) DC oltage Output range: -5-5 DC, -10-10 DC Conformance range: -5.5-5.5 DC, -11-11 DC Minimum span: 250 m, 1 Load resistance: 200 kω min. INSTALLATION Power Consumption AC: 7 A at 100 10 A at 200 12 A at 264 DC: 4 W Operating temperature: -5 to 55 C (23 to 131 F) Storage temperature: -5 to 55 C (23 to 131 F) Operating humidity: 10 to 85 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 120 g (0.26 lb) except base PERFORMANCE Accuracy: Input accuracy output accuracy input accuracy (output accuracy segment gain) when segment gain > 1 See CALCULATION EXAMPLES OF OERALL ACCURACY. Inversely proportional to the setting span. Input accuracy (% of max. input range): ±1Ω or ±0.03 %, whichever is greater. Display accuracy: Input display: Input accuracy ±1 digit Output display: Input accuracy output accuracy ±1 digit Output accuracy: (% of max. output range) 0-20 : ±0.06 % -5-5 : ±0.03 % -10-10 : ±0.03 % Temp. coefficient (% of max. I/O range): ±0.015 %/ C (±0.008 %/ F) Response time (filter time constant: 0 sec.): 0.5 sec. (0 90 %) Line voltage effect: ±0.1 % over voltage range Insulation resistance: 100 MΩ with 500 DC Dielectric strength: 1500 AC @1 minute (Ch1.input to ch2.input to ch1.output to ch2.output to power to ground) CALCULATION EXAMPLES OF OERALL ACCURACY [Example] Total Resistance 1000 Ω, Input Setting 100 600 Ω, Output Range 0 20, Output Setting 4 20, Segment Gain 1.5 Overall accuracy Input Accuracy = Total Resistance (1000 Ω) Input Span Setting (500 Ω) 0.03 % = 0.06 % Less than 1 Ω thus 1 Ω (0.1%) is selected. Output Accuracy = Output Range Span (20 ) Output Span Setting (16 ) 0.06 % Segment Gain (1.5) = 0.1125 % Overall Accuracy = 0.1 0.1125 = ±0.2125 % M1EXM SPECIFICATIONS ES-5983 Rev.0 Page 2/7

STANDARDS & APPROALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low oltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input or output to power: Reinforced insulation (300 ) Input to output: Basic insulation (300 ) RoHS Directive EN 50581 M1EXM SPECIFICATIONS ES-5983 Rev.0 Page 3/7

EXTERNAL IEW Display Up Button Mode Button Down Button Set Button Configurator Jack COMPONENT Display Mode Button Up Button Down Button Set Button Confi gurator Jack FUNCTION Indicates present values, setting values and abnormal information. Two types of present values at upper and lower are displayed by setting. Used to shift from measuring mode to each setting mode. Destination to shift is changed by the time pressing and holding the button. Used to return from each setting mode to measuring mode (press and hold for 2 sec. or more). Used to shift through setting parameter, and to increase or select setting value. Used to shift through setting parameter, and to decrease or select setting value. Used to change setting value of setting parameter. When at setting changeable state, used to enter (save) the setting value. Used to move on through digits of setting value at setting changeable state. Used to confi gure with M1E confi gurator software (model: M1ECFG). At the same time, set the lockout setting of the unit to lock. Refer to the operating manual (EM-5983-B) for detailed procedures. TERMINAL ASSIGNMENTS 1 2 3 4 6 7 8 9 5 10 No. FUNCTION No. FUNCTION 1 Unused 11 Ch1 Output 2 Unused 12 Ch1 Output 3 Ch1 Potentiometer input 3 13 Unused 4 Ch1 Potentiometer input 2 14 Ch2 Output 5 Ch1 Potentiometer input 1 15 Ch2 Output 6 Unused 16 Unused 7 Unused 17 Unused 8 Ch2 Potentiometer input 3 18 Unused 9 Ch2 Potentiometer input 2 19 Power U () 10 Ch2 Potentiometer input 1 20 Power () 11 12 13 14 15 16 17 18 19 20 * Base is not included in the package. M1EXM SPECIFICATIONS ES-5983 Rev.0 Page 4/7

PARAMETER LIST MODEL: M1EXM It is available to confi gure or confi rm settings shown below by using front button. Confi guring or confi rming with PC is available when using M1E confi gurator software (model: M1ECFG). MODE ITEM SETTING PARAMETER RANGE UNIT INITIAL ALUE Ch1 Setting 12 Ch1 0 % input setting 13 Ch1 100 % input setting 14 Ch1 0 % input scaling -99999 999999 0.00 15 Ch1 100 % input scaling -99999 999999 100.00 16 Ch1 Input decimal point No decimal point 2 places of decimals The number of decimal places: 1 5 17 Ch1 Unit (INP Scaling) Choose from 68 types* % 18 Ch1 Output range 0 20-5 5-10 10 0 20 19 Ch1 0 % output setting 0.000 19.000-5.000 4.750-10.000 9.000 20 Ch1 100 % output setting 1.000 20.000-4.750 5.000-9.000 10.000 4.000 20.000 79 Ch1 Filter time constant 0 30 sec. 0 82 Ch1 Output Zero fine adjust -5.000 5.000 % 0.000 83 Ch1 Output Span fine adjust 95.000 105.000 % 100.000 89 Ch1 Loop test -5.00 105.00 % Cancel Ch2 Setting 112 Ch2 0 % input setting 113 Ch2 100 % input setting 114 Ch2 0 % input scaling -99999 999999 0.00 115 Ch2 100 % input scaling -99999 999999 100.00 116 Ch2 Input decimal point No decimal point 2 places of decimals The number of decimal places: 1 5 117 Ch2 Unit (INP Scaling) Choose from 68 types* % 118 Ch2 Output range 0 20-5 5-10 10 0 20 119 Ch2 0 % output setting 0.000 19.000-5.000 4.750-10.000 9.000 120 Ch2 100 % output setting 1.000 20.000-4.750 5.000-9.000 10.000 4.000 20.000 179 Ch2 Filter time constant 0 30 sec. 0 182 Ch2 Output Zero fine adjust -5.000 5.000 % 0.000 183 Ch2 Output Span fine adjust 95.000 105.000 % 100.000 189 Ch2 Loop test -5.00 105.00 % Cancel M1EXM SPECIFICATIONS ES-5983 Rev.0 Page 5/7

MODE ITEM SETTING PARAMETER RANGE UNIT INITIAL ALUE Advanced 201 Display setting Upper: choose from 8 types* Lower: choose from 9 types* Upper: Ch1 PERCENT Lower: Ch2 PERCENT 202 Channel enable Choose from 3 types* Ch1 enable Ch2 enable 203 Brightness 1 (darkest) 4 (brightest) 4 204 Display timeout 0 (always on), 1 60 min. 10 205 Reset all settings OFF / RESET OFF 206 ersion indication Ch1 210 Ch1 User's table linearization Disable / Enable Disable Linearization 276 Ch1 Number of points 2 111 2 277 498 Ch1 Table -5.00 105.00 % X001-5.00 Y001-5.00 X002 105.00 Y002 105.00 Ch2 Linearization 510 Ch2 User's table linearization Disable / Enable Disable 576 Ch2 Number of points 2 111 2 577 798 Ch2 Table -5.00 105.00 % X001-5.00 Y001-5.00 X002 105.00 Y002 105.00 * For detailed types, refer to the operating manual (EM-5983-B). EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 125 (4.92) 45 (1.77) [4 (.16)] * Base is not included in the package. DIN RAIL 35mm wide 7 (.28) 5(.20) 89 (3.50) 5(.20) 7 (.28) 36 (1.42) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 M1EXM SPECIFICATIONS ES-5983 Rev.0 Page 6/7

MOUNTING REQUIREMENTS unit: mm (inch) 2M4 SCREW 99 (3.90) * Mounting requirements for base. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM CH1 POTENTIOMETER Max. 3 2 1 Min. CH2 POTENTIOMETER Max. 3 2 13 4 5 81 9 Low Drift Amplifie Low Drift Amplifie Digital Computation Circuit Output Driver Output Driver 11 12 14 15 CH1 OUTPUT CH2 OUTPUT 1 Min. CONFIGURATOR 10 JACK 1 Display Circuit Front Button 19 U() 20 () 13 POWER 2 16 6 17 7 18 Base Specifications are subject to change without notice. M1EXM SPECIFICATIONS ES-5983 Rev.0 Page 7/7