MODEL: MEXM Super-mini Signal Conditioners with Mini-M ME Series POTENTIOMETER TRANSMITTER (PC programmable) Functions & Features Provides a DC output proportional to a potentiometer or slidewire position input Adjustments with the front button Potentiometer s zero/span points can be captured by onsite calibrations OEL display with good visibility Typical Applications Tank levels Positions: Compensating non-linear signal from the linking mechanism of a position detector 9. (.) (.) [] POWER INPUT AC Power M: 00 0 AC (Operational voltage range, Hz) DC Power R: DC (Operational voltage range ±0 %, ripple 0 %p-p max.) P: 0 DC (Operational voltage range 0, ripple 0 %p-p max.) [] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C0: Silicone coating /C0: Polyurethane coating /C0: Rubber coating TERMINAL SCREW MATERIAL /S0: Stainless steel EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-) Up Down Mode Set (.) mm (inch) MODEL: MEXM-[][] RELATED PRODUCTS ME configurator software (model: MECFG) Downloadable at M-System s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual (EM-) for the ME configurator for applicable cable types. ORDERING INFORMATION Code number: MEXM-[][] Specify a code from below for each [] and []. (e.g. MEXM-M/Q) Specify the specification for option code /Q (e.g. /C0/S0/SET) INPUT Total resistance 00 Ω 0 kω OUTPUT Field-selectable DC Output Current output: 0-0 DC oltage output: - - + DC oltage output: -0 - +0 DC GENERAL SPECIFICATIONS Construction: Plug-in Connection: M screw terminals (torque 0. N m) Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (gray) Isolation: Input to output to power Overrange output: Approx. - to +0 % (Not available for current output not greater than 0 ) Manual zero adjustments: - to + % (factory setting: 0 %) Manual span adjustments: 9 to 0 % (factory setting: 00 %) Output setting: DIP Switch on side panel (refer to the instruction manual) Configuration: Program with front buttons or ia PC. Programmable features include: Refer to the parameter list. MEXM SPECIFICATIONS ES- Rev. Page /
MODEL: MEXM Configurator connection:. dia. miniature jack; RS--C level DISPLAY functions: s and sets measured range, engineering unit size: Approx.. 0. mm (0. 0. ) Number of pixels: 9 (horizontal vertical) Character color: Yellow life: Approx. 0000 hours (Expected time for the brightness to be reduced to 0 % when the is used continuously with brightness setting in ) type: OEL display digit: Negative digits, positive digits (-99999 to 999999) Decimal point position: Selectable INPUT SPECIFICATIONS Minimum span: % of total resistance Excitation: Approx. 0. DC OUTPUT SPECIFICATIONS DC Current Output range: 0 0 DC Conformance range: 0 DC Minimum span: Offset: Lower range can be any specific value within the output range provided that the minimum span is maintained. Load resistance: Output drive max. (Not available to output less than 0, output range may not be extended to - %) DC oltage Output range: - - + DC, -0 - +0 DC Conformance range: -. - +. DC, - - + DC Minimum span: 0 m, Offset: Lower range can be any specific value within the output range provided that the minimum span is maintained. Load resistance: Output drive max. INSTALLATION Power Consumption AC: Max.. A at 00 Max.. A at 00 Max.. A at DC: Max.. W Operating temperature: - to + C ( to F) Operating humidity: 0 to %RH (non-condensing) Mounting: Surface or DIN rail Weight: Approx. 00 g (0. lb) PERFORMANCE (without linearization) Accuracy: Input accuracy + output accuracy Inversely proportional to the span. Input accuracy (% of max. input range): ±Ω or 0.0 %, whichever is greater. accuracy: Input display: Input accuracy ± digit Output display: Input accuracy + output accuracy ± digit Output accuracy: ±0.0 % of max. output range Refer to 'CALCULATION EXAMPLES OF OERALL ACCURACY'. Temp. coefficient (% of max. I/O range): ±0.0 %/ C (±0.00 %/ F) Input resolution: Max. bits Output resolution: Max. bits Response time (filter time constant: 0 sec.): 0. sec. (0 90 %) Line voltage effect: ±0. % over voltage range Insulation resistance: 00 MΩ with 00 DC Dielectric strength: 000 AC @ minute (input to output to power to ground) CALCULATION EXAMPLES OF OERALL ACCURACY [Example] Total Resistance 000 Ω, Input Setting 00 00 Ω, Output Range 0 0, Output Setting 0 Overall accuracy Input Accuracy = Total Resistance (000 Ω) Input Span Setting (00 Ω) 0.0 % = 0. % Output Accuracy = Output Range Span (0 ) Output Span Setting ( ) 0.0 % = 0.0 % Overall Accuracy = 0. + 0.0 = ±0. % STANDARDS & APPROALS EU conformity: EMC Directive EMI EN 000-- EMS EN 000-- Low oltage Directive EN 00- Installation Category II Pollution Degree Input or output to power: Reinforced insulation (00 ) Input to output: Basic insulation (00 ) RoHS Directive EN 0 MEXM SPECIFICATIONS ES- Rev. Page /
MODEL: MEXM EXTERNAL IEW PERCENT 00.00 % OUTPUT 0.000 Up Button Mode Button SW Down Button Up Down Mode Set Set Button Configurator Jack ON OFF Output Setting DIP SW ON SW OFF COMPONENT Mode Button Set Button Up Button Down Button Confi gurator Jack FUNCTION Indicates present values, setting values and abnormal information. Two types of present values at upper and lower are displayed by setting. Used to shift from measuring mode to each setting mode. Destination to shift is changed by the time pressing and holding the button. Used to return from each setting mode to measuring mode. (press and hold for sec. or more) Used to change setting value of setting parameter. When at setting changeable state, used to enter (save) the setting value. Used to move on through digits of setting value for input/output scaling at setting changeable state, Used to shift through setting parameter, and to increase or select setting value. Used to shift through setting parameter, and to decrease or select setting value. Used to confi gure with ME confi gurator software (model: MECFG). At the same time, set the lockout setting of the unit to lock. Refer to the operating manual (EM--B) for detailed procedures. MEXM SPECIFICATIONS ES- Rev. Page /
MODEL: MEXM PARAMETER LIST It is available to confi gure or confi rm settings shown below by using front button. Confi guring or confi rming with PC is available when using ME confi gurator software (model: MECFG). MODE ITEM SETTING PARAMETER RANGE UNIT INITIAL ALUE Basic setting 0 Lockout setting Lock / Unlock Lock 0 % input setting 0 00 % input setting 0000 0 % input scaling -99999 999999 0.00 00 % input scaling -99999 999999 00.00 Input decimal point No decimal point The number of decimal places : Output range 0 0 - + -0 +0 0 % output setting 0.000 9.000 -.000.0-0.000 9.000 9 00 % output setting.000 0.000 -.0.000-9.000 0.000 places of decimals 0 0 0 0 % output scaling -99999 999999 0.00.000 0.000 00 % output scaling -99999 999999 00.00 Output decimal point No decimal point The number of decimal places : places of decimals Loop test -.00 0.00 % Cancel Option 0 Unit (INP Scaling) Choose from types* % Unit (OUT Scaling) Choose from types* % Filter time constant 0 0 sec. 0 9 Input Zero fi ne adjust -.000.000 % 0.000 0 Input Span fi ne adjust 9.000 0.000 % 00.000 Output Zero fi ne adjust -.000.000 % 0.000 Output Span fi ne adjust 9.000 0.000 % 00.000 0 Lockout setting Lock / Unlock Lock Advanced 90 setting Upper: choose from types* Lower: choose from types* 9 Brightness (darkest) (brightest) 9 timeout 0 (always on), 0 min. 0 9 Reset all settings OFF / RESET OFF 9 ersion indication 0 Lockout setting Lock / Unlock Lock Upper: INPUT Lower: PERCENT Linearization 00 User's table linearization Disable / Enable Disable Number of points Table -.00 0.00 % X00 -.00 Y00 -.00 X00 0.00 Y00 0.00 0 Lockout setting Lock / Unlock Lock * For detailed types, refer to the operating manual (EM--B). MEXM SPECIFICATIONS ES- Rev. Page /
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) MODEL: MEXM (.) (.) (.) DIN RAIL mm wide.x (.x.0) MTG HOLE (.) deep 9 (.) (.) M SCREW 9 0 9 (.) (.) (.) 9 (.0) (.) (.) 9. (.) [ (.)] When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM POTENTIOMETER max. min. + Low Drift Amplifie & Burnoutr Digital Computation Circuit Circuit Isolation Output Setting DIP SW Output Driver 0 + U(+) ( ) OUTPUT POWER CONTROL SW 9 CONFIGURATOR JACK Base Socket Specifications are subject to change without notice. MEXM SPECIFICATIONS ES- Rev. Page /