SOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X

Similar documents
SOYAL AR-725 (E-V2) V Contents AR-725 (E-V2-M) Installation AR-725 (E-V2-M) AR-725 (E-V2) AR-725 (X) Parts Description AR-725 (E-V2) AR-725 (X)

ECL-ACC980IP-V2/VP. Contents ECL-ACC980IP-V2. Installation ECL-ACC980IP-V2 ECL-ACC980IP-VP. Parts Description ECL-ACC980IP-VP A. B. C.

SOYAL AR-321H/AR-721H/ AR-725H/AR-757H ACCESS CONTROL SYSTEM. Contents AR-321H [Metal Case] AR-721H. AR-725H [Illuminated Touch-panel] AR-725H-M

AR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H)

SOYAL AR-321H/AR-331H/ AR-721H/AR-725H/AR-757H ACCESS CONTROL SYSTEM V Contents AR-321H [Touch-panel Metal Housing] 1 Product 2 User Guide 3 Ter

AR-881(EF-MT) P4 P5 P6 P7. P7 only provide to the controller that have doorbell function.

Option. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption

SOYAL AR-331(EF) Contents. Front Panel & Indicator. Installation. Connector Table CN6 CN2 V Option. 4 Accessories. 2 Terminal Cables 3 Tools

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

AR-727H. Technical Manual. 26 August Version 1.00

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

CM-110SK Standalone Keypad Installation Instructions

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Digital Keypad Introduction

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

EL-ST100 KEYPAD CONTROLLER

AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

GV-AS Controller. Installation Guide

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Single Door Standalone Access Control User Manual

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Operation manual For NG BIOSINGLE Version 1.1

W3-H Waterproof Keypad/Reader/Controller

2M IR Mini Dome Quick Installation Guide

GV-AS/EV Controller. User s Manual

Quick Start Guide. GV-CS1320 Camera Access Controller

Waterproof. Keypad/Reader/Controller

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

Two Door Controller GEN-045

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Specifications: Features:

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

ACTpro Single Door IP Controller. Operating & Installation Instructions

User Manual. Split access control with intelligent secured power supply.

Fingerprint Identification Proximity Reader. Quick Installation Guide

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

Fingerprint Access Control F1. User Manual

GV-Card Reader. User s Manual

GV-AS/EV Controller. User s Manual

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

Panoramic Fisheye IP Camera. Quick Installation Guide

DG-800 Stand-Alone Proximity Reader Instruction Manual

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

2000 Series e/em Style Keypad Installation and Programming Manual

W3-M. Metal waterproof standalone access control/reader. User Manual

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product.

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

GV-RK1352 and GV-R1352 Card Reader

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

AS Keypad User Manual

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

REX F-0-9 Standalone or Access Controller

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Installation & User Manual

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CC Series metal access control Manual

Two-door Access Controller

HSY-S209 EM Metal waterproof access control system User Manual

KP2000E/EM Series Style Keypad

180 Series Keypad. Handbook. Revision 2.1

Installation & User Manual V2.08

SYRIS SY110SA. Operating Manual. Ver:1.60

P6210 PN: 86085A A

2M Outdoor Motorized Bullet Camera

DOLXFD1000B. Waterproof Access Control/Reader

Fingerprint Access Standalone User s Manual

User Manual. PCKeypad Wireless Keypad

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

D4210 PN: 86085A

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

212iL Rev. 1.1

Security at Fingertips

DG Series. Access Control Proximity Readers DG-160 DG-800

Click Save to return to the main Setup screen.

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Installation and User Manual

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

INSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

PRO3200 Professional Modular Access Control Hardware

IPassan Installation guide

Transcription:

SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR- 0909 Contents AR-E-M Products User Guide Terminal Cables Tools P P P P c x d x A. B. C. D. P P P P AR-E Products User Guide Terminal Cables Tools P P P P e x A. AR- Products E. F. P P P Tools P a x d x A. A. Parts a. Button Head Pozidriv Tapping Screw: Mx0 d. Security Torx Screw: e. M.x Installation AR-E-M c. AR-E AR- C. A. B. F. B. A. B. C. f. A. E. e. C. G. H. D. F. A. b. Button Head Pozidriv c. Slotting Screw:.x0 B. D. Flat Head Hex Socket Screw: Mx A. g. d. C. b x c x Flat Head Cap Philips Tapping Screw: x9. Pull the cables from the square access hole of the mounting plate C. Use a screwdriver to screw the metal plate C to the wall. Take off the plastic mounting plate B from the body A, and pull the cables through the access hole of C and B, then connect to the body A. Assemble plate B with the body A, and embed the water proof strip D onto the plastic side frame. Assemble the body A onto the mounting plate C with the Allen key and screws (accessories supplied). Turn on the power and LED will light and beep will sound. Use a screwdriver to screw the base F onto the wall. Attach the water proof gasket to the body A, and pull the cables from the square hole of the base F, and connect to the body A. Assemble the body A with the base F. Screw A and F tight with the Allen key and screws (accessories supplied). Turn on the power and LED will light and beep will sound. G. A. A. b. A. e. f. H. A.+A. D. a. Put on G, and attach A onto the plastic plate A, and screw it with the Allen key and screws (accessories supplied). Put the ring O on the metal frame, and put them together onto the reader A+A, and screw them and buckle up the buckles on the back. Embed the water proof strip D onto the frame side of the base. Following by the install process of AR-E-M.

Door Illuminated Touch-panel 0909 Notice. Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing.. Cable selection: Use AWG - Shielded Twist Pair to avoid star wiring. Use CAT for TCP/IP connection.. Power supply: Don t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the reader malfunction. The standard installation: Door relay and lock use the same power supply, and reader use independent power supply.. Keypad lock: If E does not link [TCP / IP connection], the E keypad locks about seconds after power transmission.setting will work after E switches to stand-alone mode. Connector Table P P P P P P P P Cable: P Door Relay Common--Point Door Sensor Exit Switch Alarm Relay Power Cable: P RS- for Lift Blue White Purple White White Orange Purple Gray Thick Red Thick Black Thick Green Thick Blue ()DCAmp (N.C.)DCAmp ()DCAmp Transistor Output Max. /00mA (Open Collector Active Low) DC DC 0 RS-(B-) RS-(A+) Cable: P TCP/IP Output Cable: P TTL Serial Port - - Orange White Orange Green White Green - Black White Black Net - T+ Net - T- Net - R+ Net - R- Transistor Output Max. /00mA (Open Collector Active Low) Cable: P P Beeper LED Door Output Wiegand Pink Yellow Brown Blue White Thin Green Thin Blue Beeper Output /00mA, Low Red LED Output /0mA, Max. Green LED Output /0mA, Max. Transistor Output Max. /00mA (Open Collector Active Low) Wiegand DAT: 0 Input Wiegand DAT: Input Cable: P WGB Exit Switch WGB Door Sensor WGA Exit Switch WGA Door Sensor Cable: P Anti-Tamper Switch Purple White Orange White Purple Orange Red Orange Yellow N.C. Wiring Diagram Connect AR-Hto Electric Bolt Connect to Magnet Lock Electric Bolt E Exit Switch DC Magnet Lock DC PB P EIT N.C. PB P EIT DC Push Button DC Push Button

SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR- 0909 Connect AR-Hto Electric Strike Connect to Door Sensor Electric Strike DC DC Alarm PB P EIT P Door Sensor ALM N.C. CTL Relay Outpot Module DC Push Button DC Door Sensor Connect AR-Hto Readers Reader A Reader B WG WG P P WG WG P DC Connect to Door Exit Switch E Electric Bolt Relay Outpot Module Reader A N.C. CTL WG P Door Output WG P PB-A DS-A PB-B DS-B DC P Door Sensor EIT Push Button DC Adding and Deleting Tag Mode/Mode AR-H Adding the Single Tag or the Random tags Input (or Master Code) 9 UUUUU 0000 Get Tag close to RF Area(Present the tag to the controller.) OK (Memory location number) [e.g.] User Address NO.00 and NO.0 have pcs of random tags: Access programming mode 9 0000 0000 Get Tag close to RF Area OK P.S. The First tag has now been added, present the rest of the tags one after the other to add them to the system as well. Adding the Sequential tags Input (or Master Code) 9 UUUUU QQQQQ Get Tag close to RF Area (Present the tag with the lowest number to the controller.) OK (Memory location number) [e.g.] User Address NO.0 to NO.0 have 0 pcs of sequential tags:(~): Access programming mode 9 000 000 Get Tag close to RF Area(only use the tag NO.) OK Deleting the Single Tag Deleting All Tags Input (or Master Code) 0 SSSSS 9 EEEEE Input (or Master Code) 9 9 [e.g.] Delete User Address: 000 Access programming mode 0 000 9 000 Deleting a batch of Tags Input (or Master Code) 0 SSSSS 9 EEEEE [e.g.] Delete User Address: 000~00 Access programming mode 0 000 9 00 Mode At the Mode, User Address = Card Code Adding Tag Deleting All Tags Input (or Master Code) SSSSS EEEEE OK Input (or Master Code) 9 9 [e.g.] Add User Address: 0000~0 Access programming mode 0000 0 OK Tag Information Deleting Tag Input (or Master Code) 0 SSSSS (or 9 )EEEEE OK [e.g.] Delete a tag with card code CARD CODE CARD CODE Access programming mode 0 OK SITE CODE SITE CODE

Door Illuminated Touch-panel 0909 Programming A. Entering and Exiting Programming Mode Entering Input or PPPPPP [e.g.] The Default alue=, if already changed the Master Code=, input Access programming mode Exiting Input Changing the Master Code Access programming mode 09 PPPPPPRRRRRR [Input the -digit new master code twice.] [e.g.] If want to changing the Master Code=, input 09 B. Changing the Node ID of Reader Access programming mode 00 NNN MMM AAA BBB [NNN= Node ID: 000~; MMM=E Door NO.:~; AAA=WGA Door NO.:~; BBB=WGB Door NO.:~] C.Setting up the control mode () Access programming mode 0 N [N=//] Mode Support M Networking/ Stand-Alone User Capacity,000 (0~,999) Access Mode.Card only.card and PIN (-digit PIN).Card or User address (-digit) + Individual PIN (-digit individual PIN) Auto-show Duty time Event Capacity 0,000 0 Holidays Duress Time Zone unlimited Lift Anti-passback Control M Stand-Alone, (~).Card only.card and PIN (-digit public PIN= Arming PWD).Card or PIN (-digit public PIN= Duress code) M Networking/,000.Card only.card and PIN (-digit individual PIN) Stand-Alone (0~,999).Card or PIN (-digit individual PIN) Mode the number of users up to, largely because of its read-only CARD CODE, unlike Mode/Mode shall read the SITE CODE and CARD CODE. D. Setting up the password Individual PWD (M/M) Card or PIN: Access programming mode UUUUU PPPP [e.g. User address: 0000 and PWD:. Input 0000 ] Card and PIN: Access programming mode UUUUU PPPP [e.g. User address: 0000 and PWD:. Input 0000 ] 0,000 Public PWD (M) PIN only: Access programming mode PPPP [Input -digit PWD, default value: ] Card and PIN: Access programming mode PPPP [Input -digit PWD, default value:, disable PIN: 0000] unlimited E. Anti-pass-back(M/M) Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or somewhere wants to monitor not only the access but also exit condition. Enable device Access programming mode 0 U DDD [Please refer to function default value for details.] [e.g.] If the AR-E set to exit reader, WGA set to access reader. Access programming mode 0 0 0 9 [Please refer to function default value for details.] Enable card user Access programming mode SSSSS EEEEE N [N=0 Enable/ N= Disable/ N= Reset] [e.g.] User address from 00 to 00 enable the anti-pass-back function: 00 00 0 F. Auto Open Zone Door will keep opening after first man flashing card. When the reader is stand-alone, supporting only sets of auto-open zone by device setting. Auto-open zone can extend up to unlimited sets by Networking. Enable/Disable auto open zone Access programming mode 0 U DDD [Please refer to function default value for details.] [e.g.] If the AR-E set to Enable aut open zone. Access programming mode 0 0 00 [Please refer to function default value for details.] Enable/Disable auto open door without presenting card Access programming mode U DDD [Please refer to function default value for details.] [e.g.] If the WG-B set to Enable aut open door without presenting card. Access programming mode [Please refer to function default value for details.] Setting up access time Access programming mode 0 U NN HHMMhhmm H NN: sets of auto-open zone (NN=00~) HHMMhhmm=Starting time to ending time (e.g.: 0000=0:0 to :00) H= days of week + Holiday (Sat/Fri/Thu/Wed/Tue/Mon/Sun) (F= 0: disable; : enable)

SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR- 0909 G. Lift control Connect with AR-0ROB to control which floors the user will be able to access. [BAUD900] Please refer to below floor chart Single floor Set Floor/ Stop Access programming mode UUUUU LL (G) L L L L L L L L UUUU=User Address LL=Floor number (0~ floor/stop) 0 [e.g.] User address NO. only can reach the elevator to the th floor: 000 Multi floors 0 9 Access programming mode UUUUU G LLLLLLLL 0 9 [UUUUU=User address G: sets of lift control (Input: 0~) LLLLLLLL: 0 9 floors/stop setting (L=0=Disable, L==Enable) 0 9 [e.g.] User address NO. can reach only the th and 0th floor: Access programming mode 00 0 0000000 0 9 00 0000000 OK 0 9 H. Setting Up the Arming Conditions: Application:. Arming is enabled. Door open too long: Door is open longer than door relay time plus door close time..alarm system connected. Force open (Opened without a valid user card): Access by force or illegal procedure.. Door position abnormal: When power is off and then on, reader on arming bffore power off. Enable Arming status: Standby Mode Card only Enable all devices Induct valid card Input digit arming code Enter Program Mode Enable all devices: Access programming mode Enable particular device: Access programming mode U Disable Arming status: Standby Mode Card only Disable all devices Induct valid card Input digit arming code 9 There is NO arming mode for M. Factory default armingcode is:. U=Reader unit (0=E, =WGA, =WGB). Restoring Factory Settings Reset all device parameters and user card data Reset all device parameters and user card data: Access programming mode 9 9 9 Enable particular device Induct valid card Input digit arming code U Disable particular device Induct valid card Input digit arming code U Card or Passcode Card and Passcode Input digit user address Input Induct valid card Input digit pass digit pass code Input digits code Input digits arming arming code or U code or U Card or Passcode Card and Passcode Input digit user address Input Induct valid card Input digit pass digit pass code Input digits code Input digits arming arming code 9 or U code 9 or U Reset all user card data: Access programming mode 9 9 Reset IP Setting: Press IP Resent Button of main board for few seconds Appendix-Firmware Upgrade Get the upgrade software from SOYAL or our distributor and run UdpUpdater software Execute the software The software is within SOYAL CD or Login the SOYAL web to downloads Update the firmware [Please login the SOYAL web to download the new ISP Firmware.]. Input the Target Address and Port. [Load Fide] open the documents that have the new ISP Firmware. Click the new ISP Firmware and [Open] it. Click [Update Device] to start the firmware update. Till the screen shown [Program Completed]

Door Illuminated Touch-panel 0909 IP Setting Turn on your Web Browser and input factory default IP address: http://9... If the AR-E of the IP address has changed We must enter the new IP address. Page menu Monitor the on-line computer IP Setting Change the Log-in information Current State Online Status is able to monitor and show which computer is linking on Ethernet Module Show which computer is linking on Ethernet Module. Current IP address of the AR-E. Log-in User Password When you choose the "Networking Setting" or "User Password" at first. Log-in window will pop out and please input At the Factory Default User name: admin Password: No as default value,so please just press OK to log-in admin Networking Setting You will find initial IP Address 9... and check MAC Address is the same as sticker on Ethernet Module device. Please revise IP address you want, and then click Update button. After updating the IP, please re-connect the Web Browser by new IP address. After changed and updated IP to new address, re-connect the Web Browser by new IP address. User Password Change the log-in password to lock the IP setting of Ethernet Module. The password composes of 0 characters at most, it can be either A~Z or 0~9. Max. 0 characters allowed (Composed of A~Z and 0~9)

SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR- 0909 Command List Function Entering programming mode Command PPPPPP Exposition PPPPPP: Master Code, (Default value: ) Mode Exiting programming mode Exiting programming mode and enabling all device into arming status. (Including E, WGA and WGB) Exiting programming mode and U U= Enable target unit (0=E, =WGA, =WGB) enabling each device into arming status. (E, WGA or WGB) Node ID setting 00 NNN MMM AAA BBB NNN= Node ID of E: 00~; MMM= Door number of E M/M AAA= Door number of WGA; BBB= Door number of WGB Door relay time setting 0 U TTT U= Enable target unit (0=E, =WGA, =WGB) TTT= Door relay time (Input 000=Normal open / Input 00~00=~00 sec. / Input 0~09=0.~0.9 sec. ) Alarm relay time setting 0 TTT TTT= Door relay time (Input 000=Normal open / Input 00~00=~00 sec.) Control mode setting 0 N N= Mode: // Arming delay time setting 0 TTT Base on second, range: 00~ Alarm delay time setting 0 TTT Base on second, range: 00~ Master card setting 0 SSSSS EEEEE Input a user or a batch of user as the master card: 00000~999 M/M (For entering programming mode SSSSS= starting user address; EEEEE= ending user address instead of pressing master code) Auto-open zone setting 0 U NN HHMMhhmm U= Enable target unit (0=E, =WGA, =WGB) H NN: sets of auto-open zone (Range: 00~) HHMMhhmm=staring time to ending time (e.g.: 0000=0:0 to :00) : days of week -Sat/Fri/Thu/Wed/Tue/Mon/Sun (Input value: 0=disable; =enable) H: Holiday (Input value: 0=disable; =enable) Master code settings 09 PPPPPPRRRRRR PPPPPP= New master code RRRRRR= Repeat the new master code Suspend or delete tags Suspend= 0 SSSSS EEEEE = Suspend; 9 = Delete Delete= 0 SSSSS 9 EEEEE SSSSS= starting user address; EEEEE= ending user address M/: Recover tag SSSSS EEEEE Recover the paused tag M/M M: Setting up a batch of users SSSSS EEEEE SSSSS=starting Card Code; EEEEE= ending Card Code M to access by card only Setting up the PWD/PIN UUUUU PPPP UUUUU= user address; PPPP=-digit individual PWD M/M (Access mode: Card or PIN) Setting up the PWD/PIN UUUUU PPPP UUUUU= user address; PPPP=-digit individual PWD M/M (Access mode: Card and PIN) Arming output setting TTT Base on ms, range:~, default value=0, Input 0= Timeless M/M: Duress code setting PPPP PPPP=-digit PWD M/M M: Public PIN setting (P.S. Duress code will be unavailable and as public PIN at M (Card or PIN) access mode Card or PIN of M) (Default value=; disable PIN=0000) M/M: Arming PWD setting PPPP PPPP=-digit PWD M/M M: Public PIN setting (Default value=; disable PIN=0000) M (Card and PIN) Enabling or Disabling into arming Flashing a valid card and input NNNN=-digit arming PWD status NNNN U=Enable target unit (0=E, =WGA, =WGB) Enabling or Disabling target unit Flashing a valid card an input into arming status NNNN U Enabling all units into arming Flashing a valid card and input status NNNN Disabling all units into arming Flashing a valid card and input status NNNN 9

Door Illuminated Touch-panel 0909 Function Door close time Adding tags by induct Factory setting- Lift control setting: multi-doors Add/Delete tags by closing tags into RF area (M only) AR-0RO/ AR-0ROB relay time setting Factory setting- Real time clock setting Anti-pass-back (Enable user) Lift control setting: single door Duress Function and Arming output setting Delete all tag Same tag reading interval time Auto ring the clock alarm schedule Holiday Setting Function Default alue Command TTT 9 UUUUU QQQQQ 0 U DDD UUUUU G LLLLLLLL N MMM TTT U DDD YYMMDDHHMMSS SSSSS EEEEE P UUUUU LL FFF 9 9 TTTT SS HHMMTT H MMDD F Exposition Base on second, range: 000~, default value: sec. UUUUU= User address; QQQQQ= the amount of card U=Enable target unit (0=E, =WGA, =WGB) DDD=Function default value (Please refer to function default value for details) UUUUU=User address G: groups of lift control (Input range: 0~) LLLLLLLL: floors/stop setting (0=Disable, =Enable) N=0=Delete tag; N==Add tag Close tag into RF area one by one. MMM= Node ID of lift controller TTT= relay time: 000~00=~00 sec. U= Enable target unit (0=E, =WGA, =WGB) DDD= Function default value (Please refer to function default value for details) YYMMDDHHmmSS: Year/Month/Day/Hour/Min./Sec. SSSSS=starting user address; EEEEE=ending user address P=0=Enable; P==Disable; P==Initial UUUUU=User Address; LL=Floor number (0~ floor/stop) Arming output: FFF= 00 (default value) Duress Function: FFF= 000 Base on 0ms, range from 0 to 000 SS= sets auto alarm schedule, range 0~ HHMM= HH:MM (ex. 00: Ring bell at 0:0) TT=Period of time to ring bell (Base on second, range 0~99 sec.) : days of week -Sat/Fri/Thu/Wed/Tue/Mon/Sun (Input value: 0=disable; =enable) H: Holiday (Input value: 0=disable; =enable) MM= Month of year (0=Jan...0=Oct.) DD= Date of month (0=st day of month) F= 0:Del; : Add 0 U DDD Default alue Function Option alue Application Time Attendance Auto Re-lock Auto Open 0: Yes 0: Disable 0: Disable : No : Enable : Enable 00 00 00 Networking When Access Mode is "Card and PIN", Readers can skip pressing PIN code. 0: Disable : Enable 00 Exit by Push Button Enable force Open As Access/Exit Reader Anti-pass-back 0: Disable 0: Slave 0: Exit 0: Disable : Enable : Mater : Access : Enable 0 0 0 Networking Networking Networking [e.g.] DDD value of AR-E to Enable "Auto Open" + "Exit by Push Button" + "Anti-pass-back" =00+0+= As a result of that, the command will be 0 0 Mode M/M M/M M M/M M/M M/M M/M U DDD Default alue Function Option alue Application Stop Alarm by... Open door immediately without st card presented at auto open zone. 0: None 0: Disable : Push button/ Door Closed : Enable 0 U = Enable target unit (0=E, =WGA, =WGB); DDD = alue SOYAL http://www.soyal.com To have more detailed information, E-learning, and Q&A, please visits our website. Thanks for You