DDE-B Robot station Ref. DDRE-B

Similar documents
English Nano Rework station Ref. NASE-A

1 Tool Control Unit Ref. DI-D

English Heavy Duty station Ref. HDE-A

English Heavy Duty station Ref. HDE-A

Four-Tool Control Unit

Four-Tool Control Unit

Premium Precision Soldering station

Precision Soldering Station Ref. CD-SE

Premium 4 Tools Rework station with Electric Pump Ref. DMSE-A

Premium Soldering station Ref. DIT-D

1 Tool Control Unit Ref. DI-D

INSTRUCTION MANUAL Nano Rework station Ref. NASE-B

INSTRUCTION MANUAL Fume Extractor Ref. FAE2-5A

ESD safe. A global organization at your service. The power of experience. High technology, superior quality

JOVY SYSTEMS. isolder-40. User Manual. Rev. 1.00

SPECIFICATION SHEETS REV:12 / APRIL 10

TP3005P EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0

INFRARED PRE HEATER

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

High Precision Quad Output DC Power Supply

UP-1-1 Channel Dimmer. User manual. dimmer pack

UP-1-1 Channel Dimmer dimmer pack. user manual

LED Pixel Rail Drive 640 controller. user manual

TA18 active subwoofer. user manual

V /06/ Velleman nv

1 Channel Strobe Controller ORDERCODE 40226

Pixel Panel 144 RGB effect panel. user manual

To connect the AC adapter:

User Guide True RMS Multimeter Extech EX205T

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Metcal MX User Guide. Power. Precision. Performance. Soldering, Desoldering and Rework System _4

TA12 full-rangespeaker. user manual

Network Camera. Quick Guide DC-B1203X. Powered by

IM /2016 REV01 LACI Production Monitoring Module

HX1 Bluetooth Stereo Headset

DS-2 RF DMX dimmer. user manual

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

CHAPTER 2: USING MANAGER PREFERENCE. 2.1 Using Manager Mode Using CSAFE Console (back side) Access Layout...

Variable Temperature Digital Solder and Testing Station

WT 2M. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

OMM200 and OMM200T. Metallurgical Microscope

TECHNICAL DATA. V-PIX Quad Bar. Product code CL-VPIX-4-40 Light colour Full spectrum 8 / 480 (see above)

DC-D2212R / DC-D2212WR

LED Par 64 Short DMX ORDERCODE 42431

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

EC Series. Safety Guide

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

Large Police Light 100W ORDERCODE 80361

FT-20 Fire Training Fog Machine User Manual English

Promopar ORDERCODE 30120

MX3 BT LED Party Tube

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

SB 115A active subwoofer. user manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

User Safety. Electrical Safety. Phaser 4500 Laser Printer

Amplified subwoofer - 12" - 400W RMS

impact INSTRUCTIONS VS-LCD Series Flash lighting equipment and accessories

TB-1230 QW. User Manual Please read the instruc on carefully before use

xbrick Full-Colour 16 3W LED floodlight user manual

da Vinci Super Quick Guide da Vinci Super Safety Precautions Product instructions Unboxing and Installation Product specification

Mini Digital Multimeter Model MN15. User's Guide

Digital Photo Frame With Alarm Clock Model DPF-363

Serial No. OWNER S MANUAL. Installation & Operation

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.

LED Dancefloor ORDERCODE 42300

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS

MA100 full-range speaker. user manual

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

MATRIX LED LED User Manual Please read the instructions carefully before use

Haze 800 DMX. User Guide. English

PHOS mini OPERATING INSTRUCTIONS

PHOS 20/40 downlight OWNER'S MANUAL

User's Guide. Model High Precision Quad Output DC Power Supply

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

Manual. Portable Smart Soldering Station TS100 12/24V computer-controlled, programmable, adjustable temperature. No Copyright Graupner/SJ GmbH

1 Channel Sliding Profile Dimmer ORDERCODE 50425

Octostrip ORDERCODE 42220

Vacuum Tubes Power Supply Unit. for WA7 and WA7d Fireflies. Owner s Manual. Please review this manual before operating your WOO AUDIO product.

LED Pixel Rail 40 RGB LED strip. user manual

TVAC25100 TVAC25110 User manual

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

Int3233. Soldering Station. Instruction Manual

Camera A14 and A34 Dome Camera

Installing and Configuring Rialto Analytic Appliances

IGLOO IGLOO EASY INSTRUCTION MANUAL

DOT MATRIX PRINTER SP6000 SERIES

Installation Job Aid for Ethernet Routing Switch 3600 Series

2017 TigerStop,LLC. Printer. February 2017 Mk1

CSI 720 Focused Infrared Welding System

7 Digital Photo Frame

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

CX1 Outdoor Color-Changing Wireless Bluetooth Speaker Please fully charge the speaker prior to first use!

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

CONTENT COMPONENTS OF PROJECTOR... 2 SPECIFICATION... 3 INSTRUCTION MANUAL... 3 CHARGING THE PROJECTOR... 3 SET UP... 4

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

TURBO HD TVI Bullet & Turret Camera

User Guide. Please read these instructions carefully before use

Transcription:

DDE-B Robot station Ref. DDRE-B

Packing List Features The following items should be included: USB-A connector 2.8 Color TFT screen 2 Tools Control Unit... 1 unit Ref. DDE-1B (120V) DDE-2B (230V) DDE-9B (100V) HD Purpose Handle with 3m cable... 1 unit Ref. T470-SA Tilt the display for easy reading Working with Robots Manage and monitor the station using a Robotic system. 1. Connect the tool to the station port by means of the CHB-A Converter. 2. Connect your Robot system to the Robot connector (RJ12) of the station. DB9-RJ12 Adapter available only if necessary (Ref: 0013772). 3. Enable the Robot option in the station settings and the notification will be displayed: Converter... 1 unit Ref. CHB-A Power cord... 1 unit Ref. 0010569 (230V) 0013671 (100/120V) Manual... 1 unit Ref. 0016281 4. Set your Robot s commands according to the Robot Communication Protocol, available on the website www.jbctools.com/jbcsoftware-menu-115.html. www.jbctools.com Robot Converter Ref. CHB-A DDE-B Robot station Ref. DDRE-b Control Unit RS-232 connection 2 3

Compatible Handles For general use Works with C245 Cartridge range General Purpose Handle Ref. T245-A Soft foam (Ref. 0016057) For precision use Works with C210 Cartridge range Precision Purpose Handle Ref. T210-A Blue Handle Ref. T245-PA Blue grip to easily distinguish it from other handles Blue Precision Handle Ref. T210-PA Blue grip to easily distinguish it from other handles Non-slip Handle Ref. T245-B Non-slip soft touch For greater demands Important: Only work with C245 cartridges when used with a DDE station. For intensive soldering jobs requiring continued high thermal power. They feature good thermal insulation and a screw which fixes the cartridge and prevents its rotation. Soft Thermal Insulator Handle Ref. T245-C Soft foam (Ref. 0016057) HD Purpose Handle Ref. T470-A HD Purpose Handle + 3m cable Ref. T470-SA Easily replace the Grips for T245-A and T245-C using the slide-on tabs (Ref. 0016057). Tri-lobed HD Handle Ref. T470-ZA For better handling of the tool. 1. Inserting tabs 2. Inserting handle 3. Removing tabs tabs new grip Thermal Insulator HD Handle Ref. T470-FA Thermal Insulator HD Handle + 3m cable Ref. T470-MA Foam Insert the slide-on tabs into the new grip. Push the grip with the tabs To remove the tabs, hold the onto the handle. grip and pull them out. Use a pliers if necessary. Note: All models are supplied with a 1.5 m cable. Note: All models are supplied with a 1.5 m cable except those specified with 3 m. 4 5

Changing and fixing the Cartridges Nitrogen Handles These are for working in an oxygen-free atmosphere providing better quality soldering. They offer extra heat to the solder joint and help prevent oxidation. The JBC GN-A Nitrogen Generator Module or an external nitrogen feed is needed at the operator s bench. Before changing the cartridge, be sure that the tip is cold. Once the cartridge is properly inserted we recommend tightening the screw to prevent moving. *Important: It is essential to insert the cartridges as far as the mark for a good connection. Nitrogen Precision Handle Ref. T210-NA Works with C210 Cartridge range Nitrogen feed Nozzles Ref. B6647 Mark Nitrogen Handle Ref. T245-NA Works with C245 Cartridge range Nitrogen feed Compatible Cartridges Nozzles Ref. B7243 B7244 The T470-SA works with C245 cartridges. Find the model that best suits your soldering needs in www.jbctools.com Nitrogen HD Handle Ref. T470-NA Works with C470 Cartridge range Nitrogen feed A B Nozzles Ref. B6193 B6194 B6195 Round Chisel Round bent Bevel Special models Note: The MNE Nitrogen Flow Regulator is required. 6 7

Work Screen The DDE offers an intuitive user interface which provides quick access to station parameters. Process analysis By pressing Graphics in the main MENU, temperature and power figures in real time are displayed for each port. This helps you decide which tip to use to obtain the best quality solder joints. Graphics Status bar 17:14 Power indicator Displayed if temperature levels are activated Power 45% T245 350 ºC Temp. Levels 250 350 380 Port 2 Tool in use Station Information Power (%) Temperature 450 400 350 300 250 200 150 100 50 Power Temp 17:14 Port 1 - T245 Change port See other port graphic Menu Options Press INFO for each parameter description. Station Tools Counters System notifications (Status Bar) USB flash drive is connected. Station is controlled by a PC. Station is controlled by a robot. Station software update. Press INFO to start the process. Warning. Press INFO for failure description. Export graphics Insert a USB flash drive into the USB-A connector to save your soldering process in csv format. Peripherals Graphics Reset Error. Press INFO for failure description, the type of error and how to proceed. 8 9

Soldering Net Maintenance Remotely manage and monitor as many stations as your Windows PC can handle. Before carrying out maintenance or storage, always allow the equipment to cool. 1. Download the JBC Manager software and the user manual from www.jbctools.com/manager.html 2. Connect the stations via USB-B connector and the PC will automatically detect them. 3. The notification will be displayed on the station. Functions: - Set all the station parameters from your PC. - Organize groups of stations and set all their parameters at the same time. - Store specific configurations for later uses. - Analyze the soldering graphics of the stations on your PC and export them. USB Hub JBC Manager software any JBC station - Clean the station screen with a glass cleaner or a damp cloth. - Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts. - Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status. - Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation. Rusty and dirty surfaces reduce heat transfer to the solder joint. Clean periodically - Periodically check all cables and tubes. - Replace a blown fuse as follows: Fuse Update the station software 1. Download the JBC Update File from www.jbctools.com/software.html and save it on a USB flash drive. Preferably one with no other files. 2. Insert the USB flash drive to the station. The icon is diplayed while updating. Fuse holder Fuse holder JBC Update File 1. Pull off the fuse holder and remove the fuse. If necessary use a tool to lever it off. 2. Press the new fuse into the fuse holder and replace it in the station. - Replace any defective or damaged pieces. Use original JBC spare parts only. - Repairs should only be performed by a JBC authorized technical service. 10 11

Safety Specifications www.jbctools.com It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion. - Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire. - The power cord must be plugged into approved bases. Be sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire. - Do not work on electrically live parts. - The soldering tip and the metal part of the tool may still be hot even when the station is turned off. Handle with care. - Do not leave the appliance unattended when it is on. - Do not cover the ventilation grills. Heat can cause inflamable products to ignite. DDE-B Robot station DDRE-1B / DDRE-2B / DDRE-9B - Total weight: 3.9 Kg (8.6 lb) DDE-1B 120V 50/60Hz. Input fuse: 4A. Output: 23,5V DDE-2B 230V 50/60Hz. Input fuse: 2A. Output: 23,5V DDE-9B 100V 50/60Hz. Input fuse: 5A. Output: 23,5V - Weight: 3.8 Kg (8.4 lb) - Dimensions: 148 x 120 x 232 mm - Output Peak Power: 150W per tool - Temperature Range: 90-450 ºC (190-840 ºF) - Idle Temp. Stability (still air) ±1.5 ºC (±3 ºF) - Tip to ground resistance: <2 ohms - Tip to ground voltage: <2mV RMS - Ambient Operating Temperature: 10-40 ºC (50-104 ºF) - USB-A / USB-B / Peripherals connectors - RJ12 connector for Robot - Use a non residue classified flux and avoid contact with skin or eyes to prevent irritation. - Be careful with the fumes produced when soldering. Complies with CE standards ESD protected housing skin effect - Keep your workplace clean and tidy. Wear appropriate protective glasses and gloves when working to avoid personal harm. - Utmost care must be taken with liquid tin waste which can cause burns. - This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. Children must not play with the appliance. - Maintenance must not be carried out by children unless supervised. 12 13

Exploded View 14 15

Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warranty does not cover product wear due to use or mis-use. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. This product should not be thrown in the garbage. In accordance with the European directive 2012/19/EU, electronic equipment at the end of their life must be collected and returned to an authorized recycling facility. www.jbctools.com 0016281-0116