Optimizing Chilled Water Plant Performance. David Herman, PE, LEED AP Principal EnerG Associates, LLC

Similar documents
Chiller Replacement and System Strategy. Colin Berry Account Manager

How To Draw Chiller Monsters Werewolves Vampires And Zombies

Next Generation DCP Optimization using MV VSDs

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Chiller Plant Optimization: A Case Study

Retro-Commissioning Report

where we are, where we could be, how we can get there. 12/14/2011

Fair City Plaza. Task: Diagnose problems, recommend improvements for small municipal district cooling system

Data Center Energy Savings By the numbers

AIR COOLED CONDENSERS

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Presentation. Guaranteed Energy Savings Performance Project

What s New for Data Centers in Title Jeff Stein, PE Taylor Engineering

HVAC System Energy Savings Opportunities

Pressure Drop Calculation

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

Designing Ultra-Efficient Building Cooling Systems

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Waterside Economizing in Data Centers: Design and Control Considerations

that may have a direct effect on your bottom line. The question

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

PROCESS COOLING STUDY WORKSHEET

Siemens Demand Flow A unique and proven energy and operational cost saving application for water-cooled, central chilled water systems

Water cooled chiller plant (all-variable)

32MP Gateway. Overview and Configuration Manual

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Energy Management of the Refrigeration Systems at Zurich Airport. Burkhard Bein. Schaffhausen,

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

Air-Cooled Series R Chiller

EVC INTERFACE TOOL OPERATION MANUAL EVC INTERFACE TOOL. Part No Part No Effective July 27, 2011 Revised December 18, 2012

GP SERIES Packaged Chillers

Standard Circulating Pumps

AIR-COOLED A (Surprisingly) Cost-Effective Alternative to Water-Cooled Chiller Plants

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

Existing Building Energy Saving

HIGH EFFICIENCY Central Chiller

IBM - Energy Efficiency Recommissioning: Improving Buildings Systems Efficiency Jean-Pierre Boulianne, Pierre Lefèbvre, Yves Veilleux ICEBO 2013

RBC-AMT32E / RBC-AMS41E

a) Provision of a chilled water supply b) Provision of electric power supply and other fuels

What is the Carrier ChillerVu series counterflow application?

Pocket Quick. Reference Guide. On the TOSHIBA RBC-AMS51E. Remote Controller

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Identify the Right Applications

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Pressure switch KP. Data sheet

Optimizing Laboratory Controls through Fault Detection and Diagnostics Software. Laura Dyas, PE, LEED AP O+M, CEM Bryce Buchanan, PE, CCP, CEM

Trailblazer AGZ-E air-cooled scroll chillers

CENTRIFUGAL CONTROLS UPGRADE with Optional VFD control. MCS Total Solutions for all your HVAC\R Control Needs

AuraCool Economizer System

DEDICATED HEAT RECOVERY UNIT (DHRC)

MOLLIER DIAGRAM CAN BE IMPROVED!

MICROCOMPUTER CONTROL CENTER

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Pressure switch KP. Data sheet

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

Dykin Engineering Part & Services Sdn. Bhd.

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers. Final Report

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

RGX COMMUNICATIONS GATEWAY

Energy Efficiency Retrofit Technologies for RTUs

Case Study: Energy Systems Integration Facility (ESIF)

Communication Register Map - Uniflair Cooling

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

TacoNet For Windows Equipment Selection Version 7 October 2001 Taco, Inc Cranston St. Cranston, RI Phone:(800) FAX:(401)

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

19XR CONTROLS UPGRADE with Optional VFD control

SYRACUSE UNIVERSITY GREEN DATA CENTER NYSERDA MONITORING PLAN BHP ENERGY LLC. February 17, 2010 Revised

Liebert. PDX and PCW Compact Perimeter Cooling Solutions

PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP

New Design Strategies for Energy Saving. Intelligent free-cooling

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER

MSYS 4480 AC Systems Winter 2015

MEASURE MONITOR UNDERSTAND

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

CLICK TO EDIT MASTER TITLE STYLE. AdvanTEC Solutions CHILLER PLANT HEALTH MANAGER

Standard Circulating Pumps

Saving Water and Operating Costs at NREL s HPC Data Center

Model YLAA Air-Cooled Scroll Chillers Style A

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

PEH-WSC CONTROLS UPGRADE with Optional VFD control

HOURLY ANALYSIS PROGRAM v5.00 and v5.01

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

Aquaflair. BREC/F and BCEC/F kw

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

CARRIER HOURLY ANALYSIS PROGRAM v5.0

Chilled Water Distribution Design Considerations in Super Tall Buildings. Dusan Mrdalj, Associate, ChapmanBDSP

U-Match Series DC Inverter Service Manual PRODUCT

Table of Contents. Executive Summary Site and Unit Background Chiller Chiller Appendix... 11

KLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION

APC APPLICATION NOTE #126

BACnet MS/TP Interface User s Guide

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

ACDU01A Communicating Service Tool

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Transcription:

Optimizing Chilled Water Plant Performance David Herman, PE, LEED AP Principal EnerG Associates, LLC

Optimizing Chilled Water Plant Learning Objectives Performance Review the design and operating characteristics of each equipment component of a chilled water plant Understand how the design characteristics and operation of each equipment component effects overall chiller plant efficiency Learn how to evaluate strategies to optimize chilled water plant performance based on existing chilled water plant design and operation Review actual operating data from central chilled water plants before and after implementation of optimization strategies 3/6/2014 2

Optimizing Chilled Water Plant Performance Benchmark the existing equipment Ensure proper preventive maintenance Optimize operation of existing equipment Evaluate possible capital retrofits 3/6/2014 3

A Typical Chiller Plant 3/6/2014 4

A Typical Chiller Plant What is the average total kw/ton for an existing chiller plant including chillers, cooling towers and pumps? Approx. 1.0 kw/ton What is an optimized total kw/ton for a chiller plant? Approx. 0.8 1.0 kw/ton (lower with capital investment) 3/6/2014 5

Benchmarking Pumps What is one of the most useful diagnostic tools for benchmarking pumps? The Pump Curve 3/6/2014 6

Benchmarking Pumps Example: TACO Model #TA1538 HP 75 GPM 1400 HD 140 IMP 12.5 RPM 1750 3/6/2014 7

Benchmarking Pumps 3/6/2014 8

Benchmarking Pumps How can pump impeller size be confirmed? By deadheading the pump 3/6/2014 9

Benchmarking Pumps 3/6/2014 10

Benchmarking Pumps 3/6/2014 11

Benchmarking Pumps Why is it important to use the same gauge to measure suction and discharge pressures? To avoid gauge error since the differential pressure is needed 3/6/2014 12

Benchmarking Pumps Example: Measured Suction P: 9 psig Measured Discharge P: 58 psig Measured ΔP: 58 psig Measured ΔP: 134 head To convert psi to head, multiply by 2.31 Deadhead: 163 3/6/2014 13

Benchmarking Pumps 3/6/2014 14

Benchmarking Chillers Basic Formulas 1 ton = 12,000 Btuh GPM = Q / (500 x ΔT) Tons = GPM x ΔT / 24 3/6/2014 15

Benchmarking Chillers What ΔT is the basis of the rule of thumb of 2.4 GPM/ton for evaporator flow? ΔT = 10 degrees 3/6/2014 16

Benchmarking Chillers Tag # Manuf Model # Nom Tons #1 Trane CVHE090R00 925 #2 Trane CVHE090R00 925 #3 Trane CVHE 050 F BC 515 Evaporator GPM Ent Temp Lvg Temp Temp Diff 1,350 58.4 42.0 16.4 1,350 58.4 42.0 16.4 750 58.5 42.0 16.5 Condenser GPM Lvg Temp Ent Temp Temp Diff 1,800 99.9 85.0 14.9 1,800 99.9 85.0 14.9 1,000 100.0 85.0 15.0 FLA kw kw/ton Refrig Charge Starts Hours 927 666 0.72 R 123 1,111 34,236 927 666 0.72 R 123 1,131 25,575 526 382 0.74 R 11 1170 2,276 > 21935 3/6/2014 17

Benchmarking Chillers Barrel Nom Tons Rated Flow Rated PD FT Rated Temp Diff Evap 515 750 8.1 16.5 Cond 1,000 9.7 15.0 Meas Ent P Meas Lvg P Meas Diff P Meas PD FT Meas Flow 84 80 4 9 801 78 68 10 23 1,543 Meas Ent T Meas Lvg T Meas Temp Diff Tons Amps kw kw/ton 54.0 40.0 14.0 467 440 315 0.67 80.0 89.0 9.0 3/6/2014 18

Benchmarking Chillers Measured Flow = Rated Flow * (Rated PD/Measured PD)^0.5 kw = (3)^0.5 *V * A * PF / 1000 3/6/2014 19

Ensure Proper Maintenance Pumps Chillers Cooling Towers 3/6/2014 20

Optimize Pump Operation Over pumping results in: Flow problems Energy penalty 3/6/2014 21

Optimize Chiller Operation Lower condenser water temperature set point For every one degree drop in condenser water temperature, chiller efficiency will increase 2% Consider the trade off between lower compressor energy and increased cooling tower fan energy 3/6/2014 22

Optimize Chiller Operation What is the typical location of the differential pressure sensor controlling the pump variable speed drive? Somewhere along the chilled water supply and return piping What is the optimum location? 3/6/2014 23

Optimize Chiller Operation Relocate differential pressure sensor controlling pump variable speed drive Optimum location is across the chilled water supply and return piping at the farthest chilled water coil 3/6/2014 24

Evaluate Capital Retrofits Install variable speed drive on existing chiller(s) Significant energy savings in chiller energy use is possible (up to 30% in some applications) 3/6/2014 25

Optimizing Chilled Water Plant Performance Benchmark the existing equipment Ensure proper preventive maintenance Optimize operation of existing equipment Evaluate possible capital retrofits 3/6/2014 26

To download a copy of this presentation, go to www.energengineers.com 3/6/2014 27