5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Similar documents
Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input with Loop Power 7B35

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Analog Devices: 6B Series Backplanes : 6B Series : IOS Subsystems : Market Solutions

EVAL-INAMP-62RZ/82RZ/82RMZ

+2.5 V Low Power Precision Voltage Reference REF43

Low Voltage, 10-Bit Digital Temperature Sensor in 8-Lead MSOP AD7314

EVAL-ADG2128EB. Evaluation Board I 2 C CMOS, 8 12 Analog Switch Array with Dual/Single Supplies FEATURES DESCRIPTION

EVAL-ADCMP572/573/580/581/582

FLEX Ex Spring Clamp Terminal Base

Correlated Double Sampler (CDS) AD9823

Fractional Divider Evaluation Board AD9858FDPCB

2.5 V/3.3 V, 2-Bit, Individual Control Level Translator Bus Switch ADG3243

Evaluation Board for 14-/16-Bit, Serial Input, VOUT NanoDACs EVAL-AD5040EB/EVAL-AD506xEB

SCM5B. SLX200 Data Acquisition System. isolynx. Data Acquisition Systems. Visit our website Features

2.5 V/3.3 V, 16-Bit, 2-Port Level Translating, Bus Switch ADG3247

Installation Instructions

2.5 V/3.3 V, 8-Bit, 2-Port Level Translating, Bus Switch ADG3245

Evaluation Board User Guide UG-047

Programmable Dual Axis Digital Accelerometer and Impact Sensor ADIS16204

EVAL-ADG79XXEB. Evaluation Boards for the ADG79XX Family of Switches FEATURES GENERAL DESCRIPTION EVALUATION BOARD DIGITAL PICTURE

Evaluation Board for the AD7790/AD /24-Bit, Low Power, Σ- ADC

DDS DAC Output Evaluation Board AD9858PCB

BP16 Backplane for MAL Amplifiers

Evaluation Board User Guide UG-035

Digital ac/dc (24V) Input Module

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

Evaluation Board for Quad, 16-Bit, Serial Input, Voltage Output DAC EVAL-AD5064-1EBZ

TECHNICAL PRODUCT DATASHEET

Installation Instructions

File (19 inches) for RS3 FIC I/Os (AI/AO) migration toward a new system

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

ADSP EZ-ICE Emulator User s Guide (For Use with VisualDSP++ Release 2.0 or Higher)

AD8159 Evaluation Board Application Guide EVAL-AD8159-AC/DC

General Specifications. P2-08THM Analog Input

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

USB-2001-TC. USB-based Thermocouple Input. User's Guide

Model 7705 Control Module

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

USER S MANUAL Power Supply for Backplane Vdc

DBK48. Multipurpose Isolated Signal-Conditioning Module. Description. Supports up to Sixteen 8B Modules

IMU Axis Gyro Evaluation Board Application Note

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

M ICROSTAR LABORATORIES TM

INSTALLATION INSTRUCTIONS

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i.

Measurement Systems Datascan Installation and User Guide

Installation Instructions

Installation Instructions

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

CPCI-PS24 24V-Power Supply

EH-RIO IP67 Profibus-DP I/O modules

Evaluation Board User Guide UG-302

Analog Input Module. ST-3xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

Installation Instructions

SER-4485-SI-M USER S MANUAL

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

Installation Instructions

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Craft Port Tiny RS-232 Transceiver for Portable Applications ADM101E. Data Sheet FUNCTIONAL BLOCK DIAGRAM

Installation Instructions

5 V Charge Pump HDMI Tx Companion Chip AD9394

ROC800-Series Thermocouple Module

FUNCTIONAL BLOCK DIAGRAM DIGITAL POWER SUPPLY +5V +3.3V EXT. EXTERNAL ANALOG POWER SUPPLY V LOGIC V DD V SS SPI INTERFACE RDY RESET AD5292 GND

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

Summit-ICE Emulator Hardware User s Guide

ADP1047/8DC1-EVALZ. The daughter card can be connected to any existing ADP1047/ADP1048 evaluation board or reference design.

Installation Instructions

Evaluation Board for AD5590 EVAL-AD5590

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

VIPAC Array Family. of DC-DC Converters Up to 750 Watts. Description & Installation Guide. Product Description

Omnidirectional Microphone with Bottom Port and Analog Output ADMP401

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Digital ac/dc (24V) Input Module

PHOENIX CONTACT - 05/2007

Wiring guide for dual-output vibration and temperature sensors

TRC-190 User s Manual

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

TCP A3. Description. Module with 3 thermocouple inputs. Datasheet

POINT I/O Family. Chapter. Overview

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

Installation Instructions

microblox I/O Modules w/ Bluetooth Wireless Technology Introduction to the microblox Module Family

This Datasheet for the IC670MDL /24VDC 0.5A Output Pos. Logic 16 Pt. Grouped.

Evaluation Board for Transducer ADC EVAL-AD7730EB

Transcription:

5B Series 16 Channel Backplane 5B01 FEATURES Mix and Match 5B Series I/O Module Capability Factory Mutual (FM) Approved Approved for Use in Class I, Division2, Groups A, B, C, and D Locations. CE Certified: EMC Directive in Heavy Industrial Applications 1500 V rms Channel/Channel and Input/Output Isolation 16- channels -25 o C to +85 o C Temperature Range Single Threaded Insert for Module Hold Down APPLICATIONS Industrial Signal Conditioning Industrial Signal Isolation Industrial Signal Filtering PRODUCT OVERVIEW To address diverse applications, the 5B Series includes a family of backplanes and mounting cards which provide a complete signal conditioning solution. The 16-channel backplane can be mounted in a 19 x 3.5 panel space, providing an economical means to handle signals. FUNCTIONAL BLOCK DIAGRAM Figure 1 5B01 Functional Block Diagram This backplane provides four screw terminals per channel for all field connections. These connections satisfy all transducer inputs, process current outputs and provide transducer excitation when necessary. A cold junction temperature sensor (model AC1361) sensor is also supplied on each channel to accommodate thermocouple input modules. A pair of pin sockets permits installation of the AC1362 current sensing resistor used with the 5B32 current input module on the 16- channel backplane, a 26-pin system interface connector provides high level I/O for all channels. The 5B01 Series backplane requires a regulated +5VDC external power source. Rev. 0 Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective companies. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.326.8703 2005 Analog Devices, Inc. All rights reserved.

GENERAL DESCRIPTION Model 5B01 Backplane - The 5B01 diagrammed in Figure 1, is a 16 channel backplane that provides single-ended, high level analog input/output pins on the system connector. It is pin compatible with Analog Devices 3B Series applications. (Note, however, that 5B Series modules provide a +5V output swing rather than the +10V swing provided by 3B Series modules.) Model 5B01 System Connectors Signal connections between the 5B01 backplane and the associated measurement and control system are made at P1 and P2. These connectors are identical electrically. The redundant connectors may be useful if a 5B01 is used for both analog input and analog output and the data acquisition system has separate input and output connectors. A signal path is provided for each channel and, in addition, a number of grounding pins are present in the connector pin-out to provide inter-channel shield conductors in the ribbon cable. In some cases, discussed below, the ground conductors will not provide an accurate signal reference, so a SENSE pin is also provided in the pin-out. Several jumper and component options on the backplane provide optimum ground connections for various circumstances. Model 5B01 Grounding Each 5B01 backplane is factory configured with Jumpers W1, W3, and W4 installed. Jumper W1 grounds the shield wires in the ribbon cable (Pins 3, 6, 12, 15, 18, 21, and 24) at the 5B01 backplane. This will usually be the primary ground connection between the 5B01 and the. measurement system. This connection is required if output modules will be used on the backplane. It is also required is there is no high impedance sense input (input Low of a differential or pseudo-differential system) available on the measurement system. Jumper W3 connects the sense input, if available, to Pin 25 so that the 5B01 s ground is read. It can be left in place at all times. Jumper W4 connects +5VDC power common to input/output common (backplane measurement ground). A connection between power common and input/output common is important for the 5B Series modules to function properly, however, if this connection is made elsewhere in your system the best place is usually near the A/D or D/A converters), W4 should be cut, since a ground loop could result. Model 5B01 Inter-channel Bridge Jumpers The 5B01 gives the user the capability of directing the voltage output of any input module to an adjacent output module (e.g., Model 5B39) simply by placing a jumper between the pins of the two modules (input to channel n, output from channel n+1). This feature can be used to provide an isolated current output from an isolated input module, giving two levels of 1500 V rms isolation. Model AC1344 provides ten jumpers. Figure 2 Rev. 0 Page 2 of 7

5B01 Specifications (typical @ +25 C and V s =+5 V dc Power) Description Model 5B01 Number of Channels 16 ISOLATION Input-to-Output Continuous Channel-to-Channel Continuous 1500 V rms, Maximum 1500 V rms, Maximum MECHANICAL DIMENSIONS with modules 3.5 x 17.4 x 3.2 (88.9 mm x 442 mm x 81.3 mm) WEIGHT 11.25 oz. (305 g) MOUNTING STANDOFFS 7 COLD JUNCTION TEMPERATURE SENSORS Number provided on backplane Type Initial Accuracy @ +25 o C Accuracy +5 o C to +45 o C 16 Model AC1361 +0.5 o C +0.5 o C (+0.0125 o C/ o C) SYSTEM I/O CONNECTOR Number Type 2, 26-pin Amp 746290-6 POWER SUPPLY OPTIONS Voltage; Operating Voltage; Max Safe Limit with modules Current without modules Fuse; (F1) +5 VDC +5% +6.0 VDC Max. 0 4 Ampere Littlefuse Type 252 004 Environmental Temperature Range Rated Performance Operating Storage Relative Humidity, 24 hours -25 C to +85 C -40 C to +85 C -40 C to +85 C 0 to 95% @ +60 C noncondensing Rev. 0 Page 3 of 7

PIN CONFIGURATION AND FUNCTIONAL DESCRIPTION Figure 3 5B01 Pin-outs Table 1. Pin Function Descriptions Pin No. Description 1 CHANNEL 0 2 CHANNEL 8 3 COMMON 4 CHANNEL 9 5 CHANNEL 1 6 COMMON 7 CHANNEL 2 8 CHANNEL 10 9 COMMON 10 CHANNEL 11 11 CHANNEL 3 12 COMMON 13 CHANNEL 4 14 CHANNEL 12 15 COMMON 16 CHANNEL 13 17 CHANNEL 5 18 COMMON 19 CHANNEL 6 20 CHANNEL 14 21 COMMON 22 CHANNEL 15 23 CHANNEL 7 24 COMMON 25 SENSE 25 26 NO CONNECTION ESD CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality. Rev. 0 Page 4 of 7

OUTLINE DIMENSIONS Figure 3 Outline Dimensions Rev. 0 Page 5 of 7

NOTES Rev. 0 Page 6 of 7

NOTES 2005 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective companies. D05410-0-2/05(0) Rev. 0 Page 7 of 7