AMEU FuseSaver Highest availability and cost savings for your medium voltage distribution network

Similar documents
Siemens FuseSaver New half-cycle circuit breaker for rural smart grids to minimize operating costs of feeder and spur lines

Siemens Fusesaver and Remote Control Unit 3AD8

Auto-Changeover & Feeder Automation. Reclosers & Sectionalizers

WiAutoLink Frequently Asked Questions

CIGRE U.S. National Committee

Low Voltage Grid Digitalization Rainer Brade Product Manager

Smart Distribution Technology

SurvalentONE Distribution Management System

FCIs reduce fault-locating times and improve reliability metrics, especially the Customer Average Interruption Duration Index (CAIDI).

Fault and outage management

MV overhead feeder automation

Jose Molina Sales Manager, Global Asset - RTU500 Series (Germany)

A RELIABILITY AND COST ASSESSMENT METHODOLOGY OF MEDIUM VOLTAGE FEEDERS

Jussi Ahola, ABB Oy A self healing power system for the accurate fault location and zone concept T&D Smart Grids Europe 2012

Fortum SGEM Program Presentation of ongoing research activities

Cost and performance implications of infrastructure investment options in the Eskom Distribution network

Loop Automation. Technical Manual for the ADVC Controller Range

Intelligent Medium Voltage Circuit Breakers With Integral

Products Portfolio. Pole mounted Vacuum Recloser

2012 Grid of the Future Symposium. Demonstration of Pulsecloser Applications and Benefits in Ameren s Distribution Automation Program

ereliability Tracker Software Leader User Guide

InHand Wireless. As an important sector of smart grid building, smart distribution network faces the

Circuit Breakers,Reclosers, Switches, and Fuses

IntelliTeam II Automatic Restoration System

ELG4125: System Protection

Monitor Your Distribution Grid

KEDS DSO Development Plan. George Karagutoff, KEDS CEO Prishtina, Kosovo 20 March, 2018

UniSec, MV AIS for Secondary Distribution Smart Grid applications

MODELING OF SIMULTANEOUS FAULT TO RELIABILITY ENHANCEMENT IN DISTRIBUTION SYSTEM

Mitigating Arc Flash Hazards

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Ensto Novexia. Electrical equipment for low and medium voltage grids. ensto.com

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

New Tools for Managing Smart Switching Devices. C.A. MCCARTHY S&C Electric Company USA

SIPROTEC 5 Application Note

BEFORE THE ARKANSAS PUBLIC SERVICE COMMISSION

Switching gears. Moving to smart switchgear for primary and secondary substations

SCADA Training - T&D Automation

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Application of Distributed Intelligence to Automatic Distribution Reconfiguration for Reliability Improvement

Operating Instructions

Demonstration of the UPGRID project urban network of the future

AIR INTELLIGENT GRID AUTOMATION

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

COMPACT SUBSTATION WITH 34.5kV GIS (GAS-INSULATED SWITCHGEAR. Cleverson Shindi Takiguchi S&C Electric Europe LTd. Cape Town/WC South Africa

3- and 4-pole switching in UPS installation

Third Generation System of the Future

Lightweight and flexible recloser control for single-phase applications

Prime Point on Wave Energy Reducing Switchgear ( SWITCHGEAR ).

Evaluation of Business Cases for Smart Grid Solutions Kenny Mercado, Senior VP Electric Operations

Grid Automation packaged solutions Optimal automation of medium voltage grids

POWER GRID AUTOMATION. Pág.. n. RMU Automation

Medium Voltage Metal-Enclosed Power Capacitor Banks

3M Sensored Cable Accessories for Underground Medium Voltage Distribution System

Rotabloc Diesel Rotary UPS Systems

Sacramen Sacr t amen o t Municipal Utility Dis t Dis rict t SMUD May Ma 10,

What You Should Know About Communication Systems: Business Strategies and Options

Implementation of a Power Line Carrier solution to support anti-islanding protection and reduce interconnection costs for Distributed Generation

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

FAULT DETECTION ISOLATION AND RESTORATION ON THE FEEDER (FDIR): PICK YOUR TECHNOLOGY

Blueprint Data Center

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION

Micro Ohmmeter RMO200G

Collector System Design Considerations for Wind Farms. Sean Carr Ernst Camm S&C Electric Co.

INTELLIGENCE FOR SMART GRIDS LAST MILE

Jarkko Holmlund, European Utility Week, Energy Efficient Grid Automation Solutions for Mixed Overhead Line and Cable Networks

ABB Communication Networks Latest News FOX615 / References with TROPOS Mesh

Intelligent Grid and Lessons Learned. April 26, 2011 SWEDE Conference

Medium Voltage Metal-Enclosed Harmonic Filter Systems

Microgrids: Building Blocks of the Smart Grid Adaptive Protection Schemes for Microgrids

Road Map to Grid Modernization

Advanced Fuse-Saving Techniques. T. ROUSAN Ameren Illinois USA. J. JERMAKOWICZ S&C Electric Company USA

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Distribution Management System Open++ Opera v.3.3. User Manual

DISRIBUTED AUTOMATION FOR BACK-FEED NETWORK POWER RESTORATION

Purpose of High Voltage Circuit Switchers

Spencer Murray, Sr. Telecom Eng.

Network Configuration Document Selection for New Substations Framework

Siprotec 7ST61 / 7ST63

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

SUN2000P-375 W Smart PV Optimizer. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

Section 4 Ground-Fault Protection Devices

Toronto Hydro-Electric System Limited EB Exhibit G1 Tab 1 Schedule 1 ORIGINAL Page 1 of 15 SMART GRID PLAN

PPL Electric Utilities Summer Readiness Overview June 2017

LevelOne FSW PoE Fast Ethernet Switch User Manual

Transitioning to Smart MV/LV Substations as the Cornerstone of Your Smart Grid

IEEE PES Swiss Chapter Workshop: Microgrids Evolution and Integration in Modern Power Systems

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Smart Grid Tie Microinverter User Manual

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

Quantum Chargers Enhanced AC Line Transient Immunity

KMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available

Power System Control And Smart Grid

SIPROTEC 5 Protection, automation, and monitoring

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

BIDELEK SAREAK PROJECT: SMARTER GRIDS FOR BILBAO. Amsterdam, 5th November, 2014

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

MV Network Switchgear, Protection and Control

Transcription:

AMEU 2012 FuseSaver Highest availability and cost savings for your medium voltage distribution network October Page 2012 1 Siemens IC AG LMV 2012 MV C PPM

Challenges for rural networks Characteristics of MV power distribution networks 1. Overhead networks Radial network Long line lengths Few customers Difficult to access little revenue, but costly to own and operate! 2. Main fault causes Vegetation / Veld fires Wild life Lightning Wind Vandalism Fault characteristics - Temporary faults - Low fault currents 3. Reliabilty challenges Long drive or flight time Long time to find faulted spur Patrolling line to find fault (or not) Limited communication Poor data feedback from the field Long outage times 4. Consequences Poor reliability (SAIDI, SAIFI, MAIFI, etc.) causes financial penalties High operating costs Increasing costs to provide meaningful reliability data to the regulator Page 2

Challenges for rural networks A typical rural network example In most network configurations, the feeder is protected by a circuit breaker () or Auto- Recloser (ACR). ACR Spur lines* are usually protected by fuses. ACR Categorization of measured faults in MV Power Distribution Networks ACR no fault temporary fault permanent fault ~ 80 % ~ 20 % Page 3 * also referred to as T-offs or laterals

Necessity of cost saving (material, personnel, penalties) 80 % of a network s faults are temporary... 1. Fuses are needlessly damaged! + material costs 2. Line crews spend time to detect the fault and replace the fuse! + personnel expenses 3. Downstream users are left without power... + potential penalty payments Page 4

Traditional Spur line protection Cut-out Fuse Benefits Cheap - $100 / phase Relatively reliable Visible break Isolation Drop-out Sectionalizer Benefits Sectionalizes faulted spur line* Limitations Operates on transient faults Can jam during operation No data No remote control Limitations Requires upstream Recloser dead time to operate Water ingress and seizing when operating No data No SCADA Page 5 * also referred to as T-offs or laterals

Spur line protection solution Siemens FuseSaver ACR ACR ACR FS no fault FS temporary fault ~ 80 % FS permanent fault ~ 20 % Page 6

The Solution The FuseSaver The Siemens FuseSaver 1 single-phase fault interrupting device that prevents a fuse from blowing on transient faults 2 3 4 5 is connected in series with a fuse, is self powered and easy to install is capable of detecting, opening and clearing a fault in a half cycle is primarily targeted at providing protection and automation of low fault level lines creates the benefits of improved network reliability and reduced maintenance callouts 6 completely encapsulated featuring vacuum switching technology Page 7

Siemens FuseSaver: Introduction Perfomance - today The fuse protects the spur line from temporary and permanent faults... but it needs to be replaced! temporary or permanent fault Current Fuse Page 8

Siemens FuseSaver: Introduction Perfomance with FuseSaver - temporary faults The fuse protects the spur line from permanent faults and... the Siemens Fuse Guard protects the fuse from being blown by transient faults Current Pre-defined dead time FuseSaver Siemens FuseSaver Fuse Page 9

Siemens FuseSaver: Introduction Perfomance with FuseSaver - permanent faults The fuse protects the spur line from permanent faults and... the Siemens Fuse Guard protects the fuse from being blown by transient faults Current Pre-defined dead time FuseSaver Siemens FuseSaver Fuse Page 10

Performance Comparison Page 11

Siemens FuseSaver Introduction: Product overview Parameters Maximum operating ambient temperature +50 C Minimum operating ambient temperature -30 C Solar radiation 1.1 KW/m 2 Maximum altitude 3000 m Humidity 0 to 100 % Page 12

FuseSaver Benefits Handling Lightweight (5.5 kg) Fast and easy installation plug and play No change in protection scheme needed Simple line installation Safety benefits for live-line crew thanks to half-cycle switching Technology Smart grid-ready with communications module Highly integrated and innovative technology Protection, monitoring, metering, and control in a single unit Self-powered Half-cycle switching fastest vacuum circuit breaker on the market Page 13

FuseSaver Benefits Costs Typical return on investment is less than two years Improved network reliability means fewer penalty payments for SAIFI, SAIDI etc. Reduced operating costs thanks to reduced maintenance callouts Page 14