K1F006ALH cam switch - 6-pole A - screw mounting

Similar documents
K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1B004TLH cam switch - 1 pole A - screw mounting

K1D012ULH cam changeover switch - 2-pole A - screw mounting

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

XACA2074 pendant station XAC-A pistol grip - 2 push buttons 1 Emergency stop

XCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

XCMN2102L2 limit switch XCMN - steel roller plunger - 1NC +1NO - snap - 2 m

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

XCMD21F0L2 limit switch XCMD - M12 metal end plunger - 1NC+1NO - snap - 2 m

ZB5FG09 flush mounted selector switch head key pos stay put

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

RE9RA21MW7 off-delay timing relay s V AC -

XB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

XCKP2110G11 limit switch XCKP - metal end plunger - 1NC+1NO - snap - Pg11

XB4BL Main. Device short name. Fixing collar material. Shape of signaling unit head. Contacts type and composition

XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

RM4TR31 three-phase network control relay RM4-T - range V

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

RM4TA32 three-phase network control relay RM4-T - range V

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

TM3SAF. Main. Device short name

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

XCMD2110L1 limit switch XCMD - metal end plunger - 1NC +1NO - snap - 1 m

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

ABS2EC01EB input interface module mm - solid state - 24 V DC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

ZB4BW061 light block with body/fixing collar for BA9s bulb 250V 1NO

RMCN22BD Analog Converter ma - for Zelio Analog

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

RM4LA32M liquid level control relay RM4-L V AC

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

RM4JA31M current measurement relay RM4-J - range ma V AC

XUX9ARCNT16 photo-electric sensor - XUX - polarised - Sn 11m VAC/DC - terminals

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

ZB4BG212 selector switch head Ø22 2-position stay put Ronis 421E

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

ZB4BD2 black selector switch head Ø22 2-position stay put

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

TM3SAK. Main. Device short name

ZB4BD2 SEL SWITCH. Main. Product or component type Device short name. Mounting diameter Sale per indivisible quantity Shape of signaling unit head

ZB4BW533 green flush illuminated pushbutton head Ø22 spring return for integral LED

ZB4BG7 selector switch head Ø22 3-position spring return Ronis 455

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

ZB4BV013 white pilot light head Ø22 plain lens for integral LED

TM3DI16G module TM3-16 inputs spring

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

XB4BW33B5 green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

XB4BT845 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO

ZB4BA6. Main. Sale per indivisible quantity 1. Shape of signaling unit head Round. IP66 conforming to IEC IP69K IP69

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ZB4BS844 red Ø40 Emergency stop pushbutton head Ø22 trigger and latching turn release

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

ZB5AD2 black selector switch head Ø22 2-position stay put

XCKN2106P20 limit switch XCKN - cat's whisker - 1NC+1NO - snap - M20

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

ZB5AA46 red recessed pushbutton head Ø22 spring return unmarked

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ZB4BS944 red Ø40 Emergency stop pushbutton head Ø22 trigger and latching key release

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

Transcription:

Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam switch head type Type of operator Rotary handle padlocking Presentation of legend Cam switch function Return Switching angle 45 Off position Poles description Harmony K Complete cam switch K1 12 A Front mounting Multifixing With front plate 45 x 45 mm Black handle, length = 35 mm Without With metallic legend, 0-1 black marking Switch Without With Off position 6P Switching positions Right: 0-45 IP degree of protection IP40 conforming to NF C 20-010 IP40 conforming to IEC 529 [Ui] rated insulation voltage 690 V degree of pollution 3 conforming to IEC 60947-1 [Ithe] conventional enclosed thermal current 10 A Rated operational power in W 8300 W AC-21/400 V 3 phases conforming to IEC 947-3 600 W AC-3/230 V 1 phase conforming to IEC 947-3 4800 W AC-21/230 V 3 phases conforming to IEC 947-3 2200 W AC-23A/690 V 3 phases conforming to IEC 947-3 2200 W AC-23A/500 V 3 phases conforming to IEC 947-3 2200 W AC-23A/400 V 3 phases conforming to IEC 947-3 1500 W AC-3/690 V 3 phases conforming to IEC 947-3 1500 W AC-3/500 V 3 phases conforming to IEC 947-3 1500 W AC-3/400 V 3 phases conforming to IEC 947-3 1500 W AC-3/400 V 1 phase conforming to IEC 947-3 1500 W AC-23A/230 V 3 phases conforming to IEC 947-3 1100 W AC-3/230 V 3 phases conforming to IEC 947-3 10500 W AC-21/500...660 V 3 phases conforming to IEC 947-3 [Ie] rated operational current AC 5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3 3 A at 230 V AC-15 conforming to IEC 947-5-1 2 A at 400 V AC-15 conforming to IEC 947-5-1 1 A at 500 V AC-15 conforming to IEC 947-5-1 Electrical durability Operating rate 500000 cycles AC-3 500000 cycles AC-23 1000000 cycles AC-21 1000000 cycles AC-15 8.333 cyc/mn AC-15 2.5 cyc/mn AC-3 2.5 cyc/mn AC-23 2.5 cyc/mn AC-21 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Mar 27, 2013 1

Short-circuit current Short circuit protection 10000 A 16 A by cartridge fuse, type gg [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 947-1 4 kv in isolating function Contacts operation Positive opening Electrical connection Mechanical durability CAD overall width CAD overall height CAD overall depth Product weight Slow-break With Captive screw clamp terminals solid, 1 x 2.5 mm² Captive screw clamp terminals flexible, 2 x 1.5 mm² 1000000 cycles 45 mm 45 mm 97 mm 0.168 kg Environment Standards Product certifications Protective treatment Ambient air temperature for operation -25...55 C Ambient air temperature for storage -40...70 C EN/IEC 60947-5-1 for control circuit EN/IEC 60947-3 for power circuit CENELEC EN 50013 UL 240 V 0.33 hp 1 phase 2 -pole(s) UL 240 V 1 hp 3 phases CSA 240 V 3 hp 3 phases 2 -pole(s) CSA 240 V 1 hp 1 phase Shock resistance 30 gn conforming to IEC 68-2-27 Vibration resistance 5 gn, 10...150 Hz conforming to IEC 68-2-6 Class of protection against electric shock Class II conforming to NF C 20-030 Class II conforming to IEC 536 TC 2

Dimensions Drawings Operating Head and Body Front Mounting "Multi-Fixing" a e 73 mm/2.87 in. support panel thickness 1 mm to 6 mm./0.039 in. to 0.24 in. 3

Technical Description Link Positions (Factory Mounted) Diagram for 1 to 6-pole Switches Select the number of poles according to the product characteristics. I1 Input 1 I2 Input 2 O1 Output 1 O2 Output 2 Marking Angular Position of Switch Switching Program Diagram for 1 to 6-pole Switches Select the number of poles according to the product characteristics. (1) 1-pole (2) 2-pole (3) 3-pole (4) 4-pole (5) 5-pole (6) 6-pole 4

Convention Used for Switching Program Representation Contact closed Contact closed in 2 positions and maintained between the 2 positions Sealed assembly for auto-maintain control Overlapping contacts contacts). Example: Spring return position: for a switching angle of 90, spring return is over 30 after the last position (for a maximum of 3 simultaneous 5