Standards Update Notice (SUN) Issued: April 25, 2017

Similar documents
Standards Update Notice (SUN) Issued: August 11, 2017

Standards Update Notice (SUN) Issued: January 11, 2016

Test Report S

Contact protection relay

E1 Plus Electronic Overload Relay

UL TEST REPORT AND PROCEDURE

File E Project 12SC February 9, 2013 REPORT. Component - Protectors, Low-voltage Solid-state Overcurrent

Functional Safety - Philips Fortimo System. Philips V&A - Lighting Controls May 07, 2013

UL TEST REPORT AND PROCEDURE

Bulletin 817 Thermistor Protection Relay

CONTENTS 3 EN :2006

File E Project 93ME39941, Issued: November 29, 1993 New: April 26, 2006 REPORT COMPONENT - POWER SUPPLIES. For Use In

Certification Exams. Detailed Content Outlines Level 2 Certified Assistant Technician Level 3 Certified Technician Level 4 Certified Senior Technician

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

F550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1

GE Power Management. MMII Intelligent MCC Controller

1510 MOTOR CONTROLLERS

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV

UL TEST REPORT AND PROCEDURE

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

LED Driver Compact dimming

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

4-step Chiller and Heat Pump Controller

Electrical Specifications

LED Driver Linear / area dimming

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

SIMOCODE 3UF Motor Management and Control Devices

Max. Input Power (W) Input Current. (A pk/50%-µs) Dimming Method. 1-10V Isolated DALI

Title System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)

Zener Barriers Bulletin 937Z

VI-IAM /MI-IAM Input Attenuator Module

Max. Input Power (W) Input. (Arms) 277V. Vin 41/ 100. Dimming Method. 1-10V Isolated UL Class 1 and Class 2 Wiring. Enclosure

ADVANCED MICRO SYSTEMS

UL TEST REPORT AND PROCEDURE

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

Redundancy unit CP-A RU

www. ElectricalPartManuals. com l Basler Electric MPS100 MOTOR PROTECTION SYSTEM ADVANTAGES WINDOWS SOFTWARE ADDITIONAL INFORMATION

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

Thermistor motor protection relay CM-MSS.11

UL TEST REPORT AND PROCEDURE

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

Smart Inrush Current Limiter Enables Higher Efficiency In AC-DC Converters

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

File E Project 91SC COMPONENT POWER SUPPLIES INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

DRAFT. Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters. 1.0 Introduction DANGER. 1.1 Related Documents

User Guide. Cloning interface small option module for Unidrive and Commander GP. Part Number: Issue Number: 3

Solar Combiner Enclosure

PERMANENT DOCUMENT. Annex AU to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

LED Driver Compact dimming

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

LED Driver Compact dimming

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)

ELG4125: System Protection

INTERNATIONAL STANDARD

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

File E Project 00SC September 27, 2000 REPORT COMPONENT - POWER SUPPLIES, MEDICAL AND DENTAL EQUIPMENT

PowerFlex 400 AC Drive Guide Specification

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Operating instructions. Switching amplifier DN0210 DN / / 2015

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

02/11/2015

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Standards Update Notice (SUN) Issued: July 28, 2017

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

What s going on? 1.2/50-8/20 surge current parameters

GB/T / IEC :2006

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

C E R T I F I C A T E O F C O M P L I A N C E

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Electrical Specifications

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

UL TEST REPORT AND PROCEDURE

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Operating instructions. Speed monitor D / / 2014

Digital Clamp-on Meter Instruction Manual

DEMKO CERTIFICATE. Certificate No Page 1/3 Date of Issue Certificate Holder. Manufacturer. Production site

FIBARO SINGLE SWITCH

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

NTC thermistors for inrush current limiting

An Urgent Bulletin from CSA Group

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Transcription:

Standard Information Standard Number: UL 1951 Standard Name: Electric Plumbing Accessories Standard Edition and Issue Date: 2 nd Edition Dated July 22, 2011 Date of Revision: February 21, 2017 Date of Previous Revision of Standard: 2 nd Edition Dated October 7, 2016 Effective Date of New/Revised Requirements Effective Date: April 19, 2018 Impact, Overview, and Action Required Impact Statement: A review of all Listing Reports is necessary to determine which products comply with new/revised requirements and which products will require re-evaluation. NOTE: Effective immediately, this revised standard will be exclusively used for evaluation of new products unless the Applicant requests in writing that current requirements be used along with their understanding that their listings will be withdrawn on Effective Date noted above, unless the product is found to comply with new/revised requirements. Overview of Changes: Update requirements for capacitors Update requirements for Switch-Mode Power Supplies Update requirements for switches Add specifications for Safety Critical Functions Revise requirements for electronic circuits Specific details of new/revised requirements are found in table below. If the applicable requirements noted in the table are not described in your report(s), these requirements will need to be confirmed as met and added to your report(s) such as markings, instructions, test results, etc. (as required). Client Action Required: Information To assist our Engineer with review of your Listing Reports, please submit technical information in response to the new/revised paragraphs noted in the attached or explain why these new/revised requirements do not apply to your product (s). Current Listings Not Active? Please immediately identify any current Listing Reports or products that are no longer active and should be removed from our records. We will do this at no charge as long as Intertek is notified in writing prior to the review of your reports. Standards Update Notice MY/KM SUN Template 03092017 Page 1 of 7

Description of New/Revised Technical Requirements -- -- Update requirements for capacitors 5.4 Info Capacitors and filters Additions to existing requirements are underlined below. 5.4.3 5.4.3.1 5.4.3.2 5.4.3.3 5.4.3.4 A capacitor connected across the line or between line and ground (such as a capacitor for radio-interference elimination) shall be suitable for the voltage involved and comply with the Standard for Fixed Capacitors for Use in Electronic Equipment Part 14: Sectional Specification: Fixed Capacitors for Electromagnetic Interference Suppression and Connection to the Supply Mains, UL 60384-14. They shall be rated for the intended application, including operating voltage, subclass, Upper and Lower Temperature rating. The duration of the damp-heat test shall be 21 days for indoor use appliances and 56 days for appliances permanently installed outdoors. X1 capacitors are generally used in circuits of permanently connected appliances. However, if the appliance is provided with a separate surge protective device that limits the impulse voltage to 2.5KV, an X2 capacitor is permitted. Y1 capacitors are used in circuits where the prevention of electric shock is afforded solely by the isolation provided by the capacitor. Two Y2 capacitors connected in series is considered to provide the same level of protection as one Y1 capacitor. Y2 capacitors are used where the prevention of electric shock is provided by the combination of the capacitor and earth ground for circuits operating at voltages 150V and 300V. Y4 capacitors are used where the prevention of electric shock is provided by the combination of the capacitor and earth ground for circuits operating at voltages 150V. -- -- Update requirements for Switch-Mode Power Supplies 5.22 Thermistors Standards Update Notice MY/KM SUN Template 03092017 Page 2 of 7

Thermistors shall comply with the Standard for Thermistor-Type Devices, UL 1434. The 5.22.1 thermistors shall be suitable for the application at the specified electrical and thermal ratings. A temperature sensing positive temperature coefficient (PTC) or a negative temperature coefficient (NTC) thermistor, that is part of a circuit that manages a Safety Critical Function shall comply with: 5.22.2 a) The Standard for Automatic Electrical Controls Part 1: General Requirements, UL 60730-1; and the Standard for Automatic Electrical Controls for Household and Similar Use Part 2-9: Particular Requirements for Temperature Sensing Controls, UL 60730-2-9, with Annex J; or b) The Standard for Thermistor-Type Devices, UL 1434. 26B Switch Mode Power Supplies 26B.1 Bridging components switch mode power supplies Components connected between the primary and secondary circuits of an isolating device such as a switching transformer or between primary and secondary earth reference points 26B.1.1 shall be evaluated to provide the specified level of isolation for the application under normal and abnormal (single component fault) conditions. An optical isolator that is relied upon to provide feedback between primary and secondary 26B.1.2 circuits of a switch mode power supply shall comply with the Standard for Optical Isolators, UL 1577. It shall have a minimum isolation voltage of 1500V. A capacitor connected between primary and accessible secondary circuits shall comply 26B.1.3 with Capacitors, Section 21. This shall consist of a single Class Y1 capacitor or two Class Y2 capacitors connected in series. 26B.2 Transformer insulation system Insulation used within a transformer of switch mode power supply shall comply with the Standard for Systems of Insulating Materials, UL 1446, for the specified temperature class 26B.2.1 of the insulation system or the Standard for Single- and Multi-Layer Insulated Winding Wire, UL 2353. 53.3 Switch mode power supplies 53.3.1 Overload tests Each output winding, or section of a tapped winding, is overloaded in turn, one at a time, 53.3.1.1 while the other windings are kept loaded or unloaded, whichever load conditions of normal use is the least favorable. Standards Update Notice MY/KM SUN Template 03092017 Page 3 of 7

Overloading is carried out by connecting a variable resistor (or an electronic load) across the power supply output. The resistor is adjusted as quickly as possible and readjusted, if 53.3.1.2 necessary, after 1 minute to maintain the applicable overload. No further readjustments are then permitted. For this test, any protective devices such as a fuse, manual reset circuit protector, thermal 53.3.1.3 protector, etc. is allowed to remain in the circuit. If overcurrent protection is provided by an overcurrent protection device, the overload test current is the maximum current which the overcurrent protection device is just 53.3.1.4 capable of passing for 1 hr. If this value cannot be derived from the specification, it is to be established by test. If no overcurrent protection is provided, the maximum overload is the maximum power 53.3.1.5 output obtainable from the power supply. 53.3.1.6 In case of voltage foldback, the overload is to be slowly increased to the point which causes the output voltage to collapse. The overload is then established at the point where the output voltage recovered and held for the duration of the test. The duration of the test is to be for 7 hour or until ultimate results are reached. At the 53.3.1.7 conclusion of the test, there shall be no charring or burning of electrical insulation, no opening of any protective device or any circuit component. 53.3.2 Simulation of faults (Component abnormals) The component faults specified in 38.2 shall include components on both the primary and 53.3.2.1 secondary side of the transformer. -- -- Update requirements for switches 5.17 Info Switches Deletions are shown lined out below. Switches shall comply with one of the following, as applicable: 5.17.1 5.17.5 a) The Standard for Special-Use Switches, UL 1054; b) The Standard for Switches for Appliances Part 1: General Requirements, UL 61058-1; c) The Standard for General-Use Snap Switches, UL 20; d) The Standard for Nonindustrial Photoelectric Switches for Lighting Control, UL 773A. Exception: Switching devices that comply with the appropriate UL standard for specialty applications (e.g. transfer switch equipment), industrial use (e.g. contactors, relays, auxiliary devices), or are integral to another component (e.g. switched lampholder) is not required to comply with this requirement. Switches that comply with Standard for Switches for Appliances Part 1: General Requirements, UL 61058-1, shall be rated as specified in 5.17.6 5.17.8. Standards Update Notice MY/KM SUN Template 03092017 Page 4 of 7

Power switches shall be rated as follows: 5.17.6 a) For a voltage not less than the standard rated voltage of the circuit or power supply to which they are connected; b) For a current not less than the rated current of the appliance; c) For Continuous Duty; d) With respect to load: 1) Switches for motor-operated appliances: for resistance and motor load if the switch would encounter this load in normal use; or 2) Switches may be regarded as switches for a declared specific load and may be classified based upon the load conditions encountered in the appliance under normal load. e) For ac if the appliance is rated for ac; f) For dc if the appliance is rated for dc. 5.17.7 Ratings and load classifications for switches other than power switches shall be based on the conditions encountered in the appliance under normal load. Switches shall also be rated with respect to endurance as follows: 5.17.8 a) Power switches: 6000 cycles; b) Power switches provided with series electronics shall be subject to an additional 1000 cycles of operation with the electronics bypassed; c) Switches other than power switches, such as speed selector switches, that may be switched under electrical load: 1000 cycles; d) The following non-power switches are not required to be rated for endurance: 1) Switches not intended for operation without electrical load, and which can be operated only with the aid of a tool or are interlocked so that they cannot be operated under electrical load; or 2) Switches for 20 ma load as classified in the Standard for Switches for Appliances Part 1: General Requirements, UL 61058-1. Standards Update Notice MY/KM SUN Template 03092017 Page 5 of 7

-- -- Add specifications for Safety Critical Functions 5A Safety Critical Functions 5A.1 Any function involved in the control, protection, and monitoring of safety-related attributes of a unit whereby a loss/malfunction of its functionality would represent an unacceptable risk of fire, electric shock, or casualty hazards would be considered a Safety Critical Function. Electronic circuits that manage a Safety Critical Function (SCF) shall be: 5A.2 5A.3 Table 5A.1 a) Reliable as defined as being able to maintain the SCF in the event of single defined component faults and b) Not susceptible to electromagnetic environmental stresses encountered in the anticipated environments of the appliance. Functions specified in the table represent the common safety critical circuit functions of typical appliances under the scope of this standard. It is not intended to represent all possible Safety Critical Functions. Any function involved in the control, protection, and monitoring of safety-related attributes of a unit whereby a loss/malfunction of its functionality would represent an unacceptable risk of fire, electric shock, or casualty hazards would be considered a Safety Critical Function. Safety Critical Functions Function Hazard Location of parameters and tests Motor running overload Risk of fire or electric 19.2 protection shock Motor locked rotor Risk of fire or electric 19.2 protection shock Motor short circuit protection Risk of fire or electric shock 19.2 -- -- Revise requirements for electronic circuits Additions to existing requirements are underlined and deletions are shown lined out below. 24.1.1 All secondary circuits shall be judged under the requirements for primary secondary circuits unless they comply with 24.1.2 24.1.5 or the requirements in 24.2 for Electronic Circuits Evaluated to the UL 60335-1 Based Requirements.Circuits on the line side of isolation components shall comply with the requirements in 24.2 for Electronic Circuits Evaluated to the UL 60335-1 Based Requirements. Standards Update Notice MY/KM SUN Template 03092017 Page 6 of 7

Additions to existing requirements are underlined and deletions are shown lined out below. 24.1.2 info 24.2 53.4 Info Components, wiring, printed wiring assemblies, insulating material, and so forth, and associated circuitry that are employed in Class 2 circuits as described in the definition of low-voltage circuits or that complies with 24.1.4 and 24.1.5 need not be investigated provided that the Class 2 circuit does not perform a safety related function, that is, it is not a safety circuit. All secondary circuits shall be judged under the requirements for primary circuits unless they comply with 24.1.3 24.1.6 or the requirements in 24.2 for Electronic Circuits Evaluated to the UL 60335-1 Based Requirements. Added as an additional option for evaluating secondary circuits CUSTOMERS PLEASE NOTE: This Table and column Verdict can be used in determining how your current or future production is or will be in compliance with new/revised requirements. Standards Update Notice MY/KM SUN Template 03092017 Page 7 of 7