Allen-Bradley 700-K40E-DJ

Similar documents
Allen-Bradley Drives

CS8 Industrial Control Relays

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

IEC Contactor Specifications

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

Bulletin 700-HL 2-Pole Terminal Block Relay

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Cat. No. (Spring Clamp. Input Voltage

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

CS7 Industrial Control Relays

Allen-Bradley 1492-RCDA4A40

EU Declaration of Conformity

Allen-Bradley Bulletin 100 Contactors

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Control, Timing + Ice Cube Relays

Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating

Motor protection relays

ALLEN BRADLEY RELAY Bulletin 700-HF

Bulletin 700-HA Tube Base Relay

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description

TeSys IEC Contactors and Overload Relays

WEG Contactors - CWM and CWME Series

Micro Contactor MA Series

1492-SP Supplementary Protectors

Control Relays Bulletin 700-M / CS 4, Bulletin 700-CF

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

CS7 Industrial Control Relays

Electronic timer CT-ARS.11

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Bulletin 700-P, 700DC-P Industrial Relays

Mini Contactors & Overloads

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

140M C 2 N A63 KN CC GJ

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Description Type For Use Cat. No. 2 N.O./2 N.C. Timers 48V. For Reversing Contactors. Suppressor V DC. Diode Suppressor

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

Bulletin 817 Thermistor Protection Relay

Electronic timer CT-ERS.21

140M C 2 E A63 KN CC GJ

3 Pole Contactors with AC operating coils

PHOENIX CONTACT Features

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

DeltaV Bulk Power Supplies

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Switching relay CT-IRE with 1 c/o (SPDT) contact

Ultra Slim Relays 24

Control & Timing Relays

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

3RA13, 3RA14 Contactor Assemblies

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

XT IEC Power Control Contactors, Starters and Overload Relays

MSR178DP. Description. Features. Specifications

Relay and Timer Specifications

Contactors and Contactor Assemblies

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

PRODUCT SPECIFICATION. PC Board Relays. Series.

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Disconnect Switches. Safe Switching and Disconnecting

194E FA 32 E P11 P11 6

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Digital ac/dc (24V) Input Module

Square D General Purpose Relays

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Protection Equipment

Installation Instructions

IEC Power Control Contactors and Contactor Assemblies

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Installation / Control Technique

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Contactors and Contactor Assemblies

Electronic timer CT-ERD.12

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

QUINT-PS/ 1AC/24DC/ 5

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

RUC industrial relays of small dimensions

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

K-Line Mini - Contactors, Overload Relays and Accessories

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

Transcription:

Bulletin Overview/Product Selection Bulletin Miniature Control Relays IEC compact industrial relay IPX Finger Protection Bifurcated contacts for low-level signals Optional integrated coil protection diode Certifications culus Listed (File No. E, Guide NKCR/NKCR) CE Marked CCC Table of Contents Product Selection... this page Accessories... - Specifications... - s Compliance UL CSA C. No. EN/IEC -, -- Meets the material restrictions for European Directive //EC - EU-RoHS -Pole AC or DC Coil Voltage AC- AC- (B) Contacts Screw Type Spring Clamp I th [A] I e [A] Connection Terminals Terminals C C /V V V V V V V Diagrams N.O. N.C. Qty. Cat. No. Cat. No... A A A A A A A A May be ordered in package quantities of. Add letter M to the end of the cat. no. Example: E-ZJM. E- RE- Z- RZ- Z- RZ- +L +L LZ- RLZ- Coil Voltage Codes The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: V, / Hz: Cat. No. E- becomes Cat. No. E-KF. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. For Screw Type Terminal Versions [V] AC, Hz D B VC AC, Hz D B VC AC, / Hz KJ KF KA KN diode DC ZQ ZJ ZD ZS ZA ZT DJ For Spring Clamp Type Terminal Versions AC, Hz D AC, Hz D AC, / Hz KJ KF diode DC ZJ ZD DJ Allen-Bradley E-DJ - Publication A-CAA-EN-P

Bulletin Assignment of Contacts Assignment of Contacts Device Combinations in Accordance with IEC - / -- Table valid for : AC / DC =.. x U s, T amb. = - C + C, normal position (horizontal rail mounting). Also valid for Bulletin R relays and Bulletin -KR auxiliary contacts. Auxiliary Contact Blocks Circuit Diagram Front Mounting -KFAE -KFAE -KFAE -KFAE -KFAE -KFAZ -KFAZ -KFAE Control Relays (AC and DC Control) Z- Z- E- LZ- A A A A Control A A A A AC/DC Z + E = Y E + E = Y AC/DC Z + E = Y Z + E = Y E + E = Y LZ + E = LY AC/DC Z + E = Y Z + E = Y E + E = Y LZ + E = LY AC/DC E + E = Y AC/DC Z + E = Y E + E = Y AC/DC Z + Z = Y E + Z = Y AC/DC E + Z = Y AC/DC Z + E = Y Z + E = Y E + E = Y LZ + E = LY For other operating limits, please contact our technical consultant. T amb. max. + C T amb. max. + C and only allowed for coil voltage V DC or V AC Publication A-CAA-EN-P -

Bulletin Accessories Auxiliary Contact Blocks Description Front-mounted auxiliary contacts Auxiliary Contact Blocks - and -pole versions Choice of contact configurations Snap on, no tools required Electronic-compatible bifurcated contacts for signals down to V/ ma Connection Diagrams Screw Type Spring Clamp Terminals Terminals N.O. N.C. For Use With Qty. Cat. No. Cat. No. May be ordered in package quantities of. Add letter M to the end of the cat. no. Example: -KFAEM. Control Modules Description Mechanical Interlock For interlocking of two adjacent contactors No added width to contactor assembly Front mount plug-in type Optional auxiliary contact blocks and suppressor modules mount onto the interlock Surge Suppressor Plug-in type Limits surge voltage on coil drop-off RC Suppressor MOV Suppressor V AC V AC V AC V AC, V DC V AC, V DC V AC, V DC Connection Diagrams -KFAE -KRFAE -KFAE -KRFAE -KFAE -KRFAE -KFAE -KRFAE -KFAE -KRFAE -KFAZ -KRFAZ -KFAZ -KRFAZ -KFAE -KRFAE For Use With -K, (AC & DC Control) Qty. Cat. No. -KMCH -KFSC -KFSC -KFSC -KFSV -KFSV -KFSV Diode Suppressor V DC May be ordered in package quantities of. Add letter M to the end of the cat. no. Example: -KFSCM. -KFSD Marking Systems Label Sheet self-adhesive paper labels each, x mm Description Qty. Cat. No. -FMS Snap-In Marker Card -MX Allen-Bradley E-DJ - Publication A-CAA-EN-P

Bulletin Specifications IEC Specifications AC- Rated Thermal Current Ambient temperature C R I th V [A] Ambient temperature C V [A] V [A] I th V [A] AC-/B Switching of Solenoids and contactors V [A] V [A] I e V [A] Short-circuit Protection "gg" Fuse acc. to IEC --, no welding of contacts Min. Switching Capacity V For bifurcated contacts (control relays and auxiliary contact blocks) Resistance and Power Dissipation V [A] V [A] V [A] V [A] V [A]. V [A] V [A] V [A]. V [A]. Fuse gg [A] [ma] Main current circuit resistance, pole [mω]. Power dissipation, poles [W]. Total power dissipation Lifespan AC control, warm [W]. DC control, warm [W]. Mechanical [Mio. op.] Electrical AC- (V / A) [Mio. op.]. Weight Load Carrying Capacity per UL/CSA AC control kg (lbs.). (.) DC control kg (lbs.). (.) Rated voltage AC [V] max. Continuous rating C [A] Switching capacity AC [A] B Rated voltage DC [V] max. Switching capacity DC [A] Q Publication A-CAA-EN-P -

Bulletin Specifications DC-/Q pole V [A]. V [A] V [A]. V [A]. V [A]. V [A]. V [A]. V [A]. V [A]. Cross Sections Conductor Cross Sections - Main Contacts, Auxiliary Contacts, and Coil Terminals R Terminal type Fine stranded with ferrule () Conductor () Conductors [mm] [mm]........ Coil Data Operating Limits AC control Hz, Hz, / Hz DC control Coil Consumption AC control Hz, Hz, / Hz DC control Operating Times AC pick-up [x U s ].. dropout [x U s ].. pick-up [x U s ]..,,, V DC:.. dropout [x U s ].. pick-up [VA/W] / hold-in [VA/W] /. pick-up [W] cold., warm. hold-in [W] cold., warm. closing delay [ms] opening delay [ms] With RC module opening delay [ms] DC Solid or coarse stranded () Conductor () Conductors [mm] [mm]. + closing delay [ms] opening delay [ms] With integrated diode opening delay [ms] With external diode opening delay [ms].... Recommended torque [Nm]. Cross section per UL/CSA [AWG] Recommended torque [lb-in]. Pozidriv No. / Blade No. screw Use same cross sections Stranded wire only Allen-Bradley E-DJ - Publication A-CAA-EN-P

Bulletin Approximate Dimensions Approximate Dimensions are shown in millimeters. Approximate Dimensions are not intended for manufacturing purposes. (mm). * ) -Minimum distance to grounded parts or walls * ) Publication A-CAA-EN-P -