COPYRIGHTED MATERIAL. Introduction. 1.1 What is a Cleanroom?

Similar documents
CLEANROOM TECHNOLOGY CERTIFICATION -EXAMINATION

CLEANROOM TECHNOLOGY CERTIFICATION -EXAMINATION

The modular application of the cleanroom solutions for manufacturing facilities

Agenda. Scope ISO IS : Flowchart. IS : Flowchart. Onderbouwd inschatten en rekenen aan cleanrooms

Test report. Evaluation of particle generation from a chair for use in cleanrooms

I3 Consulting Clean rooms for Pharmaceuticals & Medical Device Manufacturing

معتبرسازي. Validating, establishing and maintaning a routine environmental monitoring program for clean rooms

Deposition velocities of airborne microbecarrying

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 5: Operations

PARTICLE GENERATION FROM HUMANS A METHOD FOR EXPERIMENTAL STUDIES IN CLEANROOM TECHNOLOGY

Cleanroom Design. Second Edition W. WHYTE. JOHN WILEY& SONS Chichester New York Weinheim Brisbane Singapore Toronto. Edited by

Building Cleanrooms. - Regulations, Air-Handling, Design & Construction -

Modular CLEANROOM Solutions

A copy can be downloaded for personal non-commercial research or study, without prior permission or charge

A copy can be downloaded for personal non-commercial research or study, without prior permission or charge

Product Handbook SMART CLEANROOM CONTROLS

HOW TO SELECT A CLEANROOM: MODULAR CLEANROOMS FOR NEW BUSINESSES, NEW PRODUCT DEVELOPMENT

Cleanrooms and associated controlled environments. Part 14: Assessment of suitability for use of equipment by airborne particle concentration

Mixing Bio- and More Conventional Materials

Restricted Access Barrier Systems (RABS) & Isolators: The Perfect Combination of Robot System Safety and Aseptic Drug Manufacturing

WHITEPAPER CLEAN ROOM DESIGN AND THE ROLE OF FLOORING. An overview of cleanroom design and flooring considerations to ensure regulatory compliance.

The basis for precision

Calculation of air supply rates and concentrations of airborne contamination in non- UDAF cleanrooms

10 COMMON TRAPS IN DESIGNING A CLEANROOM

For further information please contact us: phone +49 (0) fax +49 (0)

Cleanroom manufacture and online supplies

This is the author s final accepted version.

UNDERSTANDING DIFFERRENT ASPECTS OF PROTECTIVE GARMENT SOLUTIONS

CLEAN ROOM TECHNOLOGY

Australian/New Zealand Standard

CLEAN ROOM PROTOCOL AND WAFER HANDLING

the closed-loop control system

PARTICLE MEASUREMENT IN CLEAN ROOMS.

A copy can be downloaded for personal non-commercial research or study, without prior permission or charge

ISPE Thailand 3 rd Seminar 2018

the closed-loop control system

Filter Fan Unit Systems. Cleanroom Products

Ease of Use. Data at Your Fingertips LMS PHARMA

APRIL 2010 VOL. 13 NO. 4. Modular Cleanrooms for Business Startups and New Product Development

Assessment of degree of risk from sources of microbial contamination in cleanrooms; 1: Airborne

FS209E and ISO Cleanroom Standards

Energy Saving in Cleanrooms

FS209E and ISO Cleanroom Standards

Press release. High-purity positioning systems for demanding applications. Assembly in Schneeberger's cleanroom

This document is a preview generated by EVS

TERRA UNIVERSAL.COM C r i t i c a l E n v i r o n m e n t S o l u t i o n s

Air Technology Division

Reliable Environmental Monitoring Systems by Design

Technovation Systems, Inc

Cleanroom Air Showers. Esco Cleanroom Air Shower, Model EAS-2C_.

EVOTEK ADVANCED CEILING TECHNOLOGY

Cleanroom Standards CLEANROOM TUTORIAL PROGRAMME CLEANROOM CLASSES ISO CLEANROOM STANDARDS (SEP 05)

Obtaining the Weld Quality You Need. What to Look for in a Cleanroom Welding Contractor

Calculation of airborne cleanliness and air supply rate for non-unidirectional airflow cleanrooms

A Basic Introduction to Clean Rooms

Introduction to Contamination Cotitrol and Cleanroom Technology Matts Rarnstorp copyright 0 WXLEY-VCI.? Verlag GmbH, 2000

CHANGES TO THE STANDARD FOR ISO ISO Cleanrooms and Associated Controlled Environments

Particles on Surfaces

Samuel Tepp Engineering Seminar Topics

Consultancy along with installation for Air Conditioning System and expertise in Clean Room Systems.

TUBES HVAC R & FITTINGS. HVACR Products Catalogue HVAC. T:

CLEANROOMS. Facilities and Practices. M. Kozicki. Arizona State University. with S. Hoenig. University of Arizona. and. P.

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 4: Design, construction and start-up

Reliable Protection with RABS. Restricted Access Barrier System Reliable Protection of Product and Process. Together always one step ahead

The Effectiveness of Air Showers in the Contamination Control Process

The Atmosphere of Trust for Advanced Technology Facilities. M+W Products GmbH

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 4: Design, construction and start-up

ISO INTERNATIONAL STANDARD

The Importance of Contamination Control at Floor Level. Carlos Mourelle EMEA Director Nov 2018

WHAT TO KNOW WHEN CONSIDERING A CLEANROOM

Cleanrooms and Standards The Road Ahead

The Micronclean. Cleanroom Handbook. Written by Neil Clayton Tim Eaton

TSI AEROTRAK REMOTE WITH PUMP PARTICLE COUNTERS INSTALLATION CONSIDERATIONS

Electronics + ESD Cleanroom Seating OPUS ESD. seating. ... chairs designed for work

MODELING PARTICLE DEPOSITION IN VENTILATION DUCTS

CLEANROOM GOGGLE SERVICE COMPLETE CONTAMINATION CONTROL

Assessment of degree of risk from sources of microbial contamination in cleanrooms; 3: Overall application

From Standards to Practice: Sterile Respirator Hoods

Invincible II. Advanced lighting systems for cleanroom applications

Clean Room Certification Reports Interpreting and Acting on the Good, the Bad and the Ugly!

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 3: Test methods

Cable Particulation Study for Cleanroom Environments. White Paper

Donning by Design: Sterile Cleanroom Gowning Evolves to Help Minimize Contamination Risk

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 5: Operations

Various possibilities for clean room production with ELION and PX

Cleanrooms & HVAC Systems Design Fundamentals (Karachi, Pakistan, February 22, 2011) Wei Sun, P.E.

Filter Fan Unit LIGHT

Environmental Monitoring Systems for critical applications

GAPS Guidelines CLEANROOMS GAP INTRODUCTION POSITION. Management Programs. A Publication of Global Asset Protection Services LLC

Set up professional machines! In this case it is worth the investment:

Industry leading low energy evaporative fresh air cooling.

The contamination risks posed by laundered cleanroom apparel. By Damon Larkin Senior Category Manager, Scientific Business

ISO INTERNATIONAL STANDARD

AIRGARD Type 11 Pleated Panel Filters

Cleanroom Suitability Assessment of Equipment according to upcoming ISO standards. Frank Buerger, Fraunhofer IPA, October 10 th 2013, Dresden

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Lighting Fixtures. Abtech offers a full line of our Cleanroom. Lay-In Light Fixtures: Teardrop Light Fixtures:

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

CLEANROOM CERTIFICATION AND ACCEPTANCE PROCEDURES

On the numerical accuracy of particle dispersion simulation in operating theatres

Transcription:

1 Introduction 1.1 What is a Cleanroom? It is clear that a cleanroom is a room that is clean. However, a cleanroom has a special meaning and it is defined in the International Organization for Standarization (ISO) standard 14644-1 as: room in which the concentration of airborne particles is controlled, and which is constructed and used in a manner to minimise the introduction, generation, and retention of particles inside the room and in which other relevant parameters, e.g. temperature, humidity, and pressure, are controlled as necessary The first two-thirds of the definition is, in essence, what a cleanroom is. It is a room that minimises the introduction, generation and retention of particles. This is achieved, firstly, by supplying it with an exceptionally large quantity of air that has been filtered with high efficiency filters. This air is used (1) to dilute and remove the particles, bacteria and chemicals dispersed from personnel, machinery and other sources within the room and, (2) to pressurise the room and ensure that no dirty air flows into the cleanroom. Secondly, a cleanroom is built with materials that do not generate particles or outgas airborne chemical contamination and can be easily cleaned. Finally, cleanroom personnel use clothing that envelops them and minimises their dispersion of particles and micro-organisms. COPYRIGHTED MATERIAL Cleanroom Technology, Second Edition. W. Whyte 2010 W. Whyte

2 Cleanroom Technology Figure 1.1 A cleanroom with personnel wearing cleanroom clothing These and other similar measures that minimise the introduction, generation and retention of contamination in a cleanroom are discussed in this book. Cleanrooms can also control the temperature, humidity, sound, lighting, and vibration. However, these parameters are not exclusive to cleanrooms, and are therefore not discussed in any detail in this book. 1.2 The Need for Cleanrooms The cleanroom is a modern phenomenon. Although the origins of cleanroom design and management go back for more than 150 years and are rooted in the control of bacterial infection in hospitals, the need for a clean environment for industrial manufacturing led to the modern cleanroom in the 1950s. Cleanrooms are needed because people, production machinery and the building structure all generate contamination. As will be discussed later in this

Introduction 3 book, people and machinery produce millions of particles, and conventional building materials can break up as well as outgas chemical contamination. A cleanroom controls the dispersion of all this potential contamination to allow manufacturing to be carried out in a clean environment so that the correct quality and reliability of the product is achieved, and, in the case of healthcare products, the patient is not harmed. The uses of cleanrooms are diverse and shown in Table 1.1 is a selection of products that are now being made in cleanrooms. Table 1.1 Some cleanroom applications Industry Electronics Semiconductor Micromechanics Optics Nanotechnology Biotechnology Pharmaceutical Medical Devices Food and Drink Product Computers, flat screens Integrated circuits used in computer memory and control Miniature bearings, compact-disc players Lenses, photographic film, laser equipment A wide variety of products at nanometre size --------------------------- Antibiotics, genetically modified organisms (GMOs) Sterile pharmaceuticals Heart valves, cardiac by-pass systems, stents, catheters Brewery products, unsterilised food and drink It may be seen in Table 1.1 that cleanroom applications can be broadly divided into two. Given in the top section of Table 1.1 are those industries where dust particles are a problem, and their presence, even in submicrometre size, may prevent a product functioning, or reduce its useful life.

4 Cleanroom Technology particle Figure 1.2 Contaminating particle on a semiconductor A major user of cleanrooms is the semiconductor fabrication industry, where microprocessors are produced for use in computers, cars and other machines. Figure 1.2 shows a photomicrograph of a semiconductor with a particle on it. Such particles can cause an electrical short circuit and ruin the semiconductor. To minimise contamination problems, semiconductors are manufactured in cleanrooms with very high standards of cleanliness. Figure 1.3 Contaminating particle inhibiting carbon nanotube growth

Introduction 5 Shown in Figure 1.3 is a contamination problem in a nanotechnology application. The photograph shows a particle sitting in the centre of a field of carbon nanotubes that are growing upwards. The growth of nanotubes around the particle is inhibited by chemical contamination diffusing from the particle. Nanotubes beyond the edge of the area of inhibition are seen to have grown normally. In the photograph, the particle is approximately 10 μm micrometres across and the area of inhibition 70 μm in diameter. The nanotubes are only 2 to 3 nanometres in diameter, so are difficult to distinguish one from another. 1 nanometre (nm) = 1/1000 micrometre (μm). The bottom section of Table 1.1 shows manufacturers that require the absence of micro-organisms, as their growth in a product could lead to human infection. The healthcare industry is a major user of cleanrooms, as microorganisms or dirt must not be injected or infused into patients through their products. Hospital operating rooms also use cleanroom technology to minimise wound infection (Figure 1.4). Figure 1.4 Unidirectional airflow system and occlusive clothing used in an operating room

6 Cleanroom Technology It may also be seen from Table 1.1 that many of the examples are recent developments and this list will certainly be added to in the future, there being a considerable and expanding demand for this type of room. 1.3 Types of Cleanrooms Cleanrooms have evolved into two major types and they are differentiated by their method of ventilation. These are non-unidirectional and unidirectional airflow cleanrooms. Unidirectional airflow cleanrooms were originally known as laminar flow cleanrooms and non-unidirectional flow cleanrooms as turbulently ventilated. The use of the term laminar flow was a mistake, as laminar flow has a meaning in physics and engineering that does not apply to the airflow in a cleanroom. Unidirectional airflow is the correct way of describing the airflow and is the term used in the ISO standards. Unidirectional airflow cleanrooms use very much more air than non-unidirectional airflow cleanrooms, and give superior cleanliness. high efficiency air filter production equipment air extract Figure 1.5 Non-unidirectional airflow type of cleanroom

Introduction 7 The two major types of cleanroom are shown diagrammatically in Figures 1.5 and 1.6. Figure 1.5 shows a non-unidirectional airflow cleanroom receiving clean filtered air through a high efficiency air filter and air diffuser in the ceiling. This air mixes with the room air and removes airborne contamination through air extracts at the bottom of the walls. The air change rates are normally equal to, or more than, 20 per hour, this being much greater than in ordinary rooms, such as in offices. In this non-unidirectional style of cleanroom, the contamination generated by people and machinery is mixed with and diluted by the supply air, and then removed. high efficiency filters production equipment Figure 1.6 Unidirectional airflow type of cleanroom Figure 1.6 shows the basic principles of a unidirectional airflow room. High efficiency filters are installed across the whole ceiling and the air to the room is supplied through these. This air sweeps down through the room in a unidirectional way at a velocity generally between 0.3 m/s (60 ft/min) and 0.5 m/s (100 ft/min) and exits through the floor, thus removing the airborne contamination from the room. This system uses much more air than the non-

8 Cleanroom Technology unidirectional airflow cleanroom but, because of the directed air movement, it minimises the spread of contamination about the room and sweeps it out through grilles in the floor. An alternative configuration has the high efficiency filters installed across the whole of one wall with the air being removed at the opposite wall. Separative devices, such as unidirectional airflow benches or isolators, are used in both non-unidirectional and unidirectional airflow cleanrooms. These give a localised supply of filtered air and enhanced air conditions where required, e.g. at the area where the product is open to contamination. 1.4 What is Cleanroom Technology? CLEANROOM TECHNOLOGY CLEANROOM DESIGN AND CONSTRUCTION standards layout construction materials services water and gases (including air) setting cleanroom to work CLEANROOM TESTING and MONITORING testing that the new room performs as designed and testing to ensure that the room continues to perform as designed CLEANROOM OPERATIONS monitoring the room conditions entry of people, machines and materials cleanroom disciplines to avoid contaminating the product cleanroom garments, including gloves, masks, etc. cleanroom cleaning and cleaning equipment Figure 1.7 Various parts of cleanroom technology and their interconnections

Introduction 9 As can be seen in Figure 1.7, cleanroom technology can be divided into three broad areas. These areas can also be seen to parallel the application of the technology as the cleanroom user moves from firstly deciding to purchase a room to finally operating it. Firstly, it is necessary to design and construct the room. To do this one must consider (1) the design standards that should be used, (2) what design layout and construction materials can be used, and (3) how services should be supplied to the cleanroom. Secondly, after the cleanroom has been constructed it must be tested to check that it conforms to the stipulated design. During the life of the cleanroom, the room must also be tested and monitored to ensure that it continually achieves the standards that are required. Finally, it is necessary to operate the cleanroom correctly so that the manufactured products are not contaminated. This requires that entry of people and materials, garment selection, cleanroom disciplines and cleaning of the room are all correctly carried out. These three fundamental elements of Cleanroom Technology are covered in this book. Acknowledgements Figure 1.1 is reproduced by permission of Compugraphics and M+W Pearce. Figure 1.3 is reproduced by permission of Murray Whyte. Figure 1.4 is reproduced by permission of Fishers Services.