232iLM Keypad Installation & Programming Instructions

Similar documents
232iLM Keypad Installation and Programming Instructions

2000 Series e/em Style Keypad Installation and Programming Manual

KP2000E/EM Series Style Keypad

212iL Rev. 1.1

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:

9212i INSTALLATION. Stand-Alone Keypad. Instructions

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Digital Keypad Introduction

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

DOLXFD1000B. Waterproof Access Control/Reader

CM-110SK Standalone Keypad Installation Instructions

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

CP150B Vandal & Weather Resistant Keypad Security Systems

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

BluePass 2-N-1 BluePass Multi-Tech Reader Manual. Installation Instructions P/N: X15

EN Series / EXN. Telephone Entry & Access Control System. Quick Start Guide (EN-2A4) ( EXN )

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

MS-3000 MicroStar Reader

Installation Instructions 4291 and 4292 Keypads

MS-7000: SuperStar Reader

G2M Control Board Installation and Operations Manual

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Installing Keypad and Backplate

Outdoor Stand-Alone Weatherproof Keypads

A-100 INDOOR STAINLESS STEEL KEYPAD WIRING & PROGRAMMING INSTRUCTIONS

Enter a new user. code. Enter. Enter a 2-digit user ID. Enter a user code. (from 00~09) (from 00~09) Enter

User Manual. PCKeypad Wireless Keypad

MS-5000: MiniStar Reader

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Installation Instructions

SECURE/NONSECURE LED SIGN USER MANUAL

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

TS InteliSwitch Digital Time Switch 24VDC/VAC

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

2GI. Touch Screen Wireless Keypad

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

DG-800 Stand-Alone Proximity Reader Instruction Manual

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

MS-4000: ShootingStar Reader

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

User Manual CS-SA Series 'SUPER ANALOG' Time Fade Stations JOHNSON SYSTEMS INC.

EL-ST100 KEYPAD CONTROLLER

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

Installation Instructions

Installation Instructions

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

IEI prox.pad Proximity Reader/Keypad Access Control Installer Guide

4X1 Switcher For 1.3. Model # HDMI-SW-4X1 USER MANUAL.

Waterproof. Keypad/Reader/Controller

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

Installation Instructions

DP-222Q Color Video Door Phone Manual

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

DP-222Q Color Video Door Phone Manual

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Installation Operation

MINI 4200 Model # - C Mini Instruction Manual V.2. This instruction manual serves as a guide for the Mini 4200.

SKE Series. 12-Pad. Installation & Instruction Manual. Essex Electronics, Inc KEY-LESS fax keyless.

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

Seven Channel Remote Control

STYLE 3600 SWITCH INTERFACE TRANSMITTER INSTALLATION AND OPERATING INSTRUCTIONS

DP4 DOOR PHONE. For Technical Assistance Please Phone: (07)

IRRIGANDER 4 SPLITTER SWITCH

Installation Instructions

IEI prox.pad Proximity Reader/Keypad Access Control Installer Guide

EXT-DVI-CAT5-4X User Manual

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B

MEGA DIAL PANEL Instructions

poly-planar Marine Audio System

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

SERIES 5100XXX8 INSTALLATION & SPECIFICATION GUIDE

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Temperature Programming Quick Reference Guide

Installation Instructions

Zodiac FR100 TM INSTALLATION MANUAL

Irrigander 8/2 Pro Expander 8 Zone Irrigation Expander Installation & User Guide Model 8ZEXT V1.0

Copy Machine Reader. Installation and Setup Guide

MODEL 9266 LITTLE LEAGUE BASEBALL SCOREBOARD. Instruction Manual

PXL-250 Tiger Controller

PT712-EI FOR FLOOR HEATING DIGITAL THERMOSTAT

AE-2. Telephone Entry Control Console. Facility Manager s Programming Guide

791/793 Easy Entry Keypads

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

Transcription:

232iLM Keypad Installation & Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6-1/2 L x 1-3/4 W x 1-1/8 D Electrical: Voltage: 5-12 VDC (keypad) 12-24 VAC/DC (controller) Current (max): 120 ma Relay Contacts: Main Relay (controller): 2 Amps Aux Relays (controller): 1 Amp Bell Relay: Form A; 1 Amp @ 30 VDC; 500 ma @ 125 VAC Features Vandal Resistant Case Sealed for Indoor or Outdoor Applications LED s for Relay Status Indication Bell Output Surface Mount Illuminated Hardened Keys Rated for Greater than One Million Key Cycles Applications Low to Medium/Heavy Traffi c Areas Rough Service Environments Mullion Frame Mounting Dimly Lit Areas Environmental: -20º F to 130 F Description: The 232iLM Access Control unit consists of two pieces: an SSWiLM keypad front end and a 232 Access Control Module. The Door Gard Series SSWiLM keypad combines elegant looks with a mullion mount design in a rugged, vandal resistant case, which you can use for almost any application. The SSWiLM has hardened backlit keys designed to perform in medium to high traffi c areas and in rough duty environments. The electronics are also conformal coated, which makes the keypad suitable for indoor or outdoor applications. Basic Operation: To gain access through the door enter your code (1-6 digits) followed by the key on the keypad. Packing List: (1) SSWiLM Keypad (1) 232 Access Control Module (1) Eight-Conductor Wire Harness (4) Three-Conductor Wire Harness (1) Controller Hardware Pack (1) Mullion Hardware Pack (1) 5/64 Allen Wrench (1) Anti-Oxidant Grease Pack (1) Installation/Programming Manual (1) Self-Contained Access Control Programming Guide Wire Harness Configuration: Pin Wire Color Signal Name 1 Red Power (+) 2 Black Power (-) 3 White/Black Data 0 4 White/Yellow Data 1 5 Blue Not Used 6 Brown Not Used 7 White Bell Relay Contact (A) 8 White Bell Relay Contact (B) Wiring Requirements: 18 AWG 1000 Ft. 20 AWG 500 Ft. 22 AWG 250 Ft 6-050800 X2 1

Keypad Installation Procedure: 232iLM Keypad Installation & Programming Step 1: Drill through the back plate using a 11/64 bit. Use the template on the back page to accurately mark the mounting holes before drilling. Then drill the mounting holes with a 9/64 drill bit. Also drill the hole for the wires. This may vary depending on the number of conductors required. Step 2: On the keypad end, strip back the insulator from the wire and tape the drain wire (shield) to the jacket. Now connect the required wires to the 8-conductor wire harness provided. The wire harness plugs into the 8-position connector on the keypad. At the other end of your wire run, strip back the insulator from the wire but do not tape the drain wire to the jacket. The drain wire must be connected to ground at the controller end. See the diagrams below. Step 3: Finally mount the keypad onto the mounting surface using the provided screws. Do no over-tighten the screws, which may result in damage. Wiring the SSWiLM Keypad to a 232 Access Control Module The connection between the SSWiLM Keypad and the 232 Controller requires a 4-conductor, stranded wire with overall foil shield. The 8-conductor wire harness from the keypad connects to connector P6 on the controller. Connect the wires, color to color (red to red, black to black, white/black to white/black and white/yellow to white/yellow). Refer to the wire lengths on the fi rst page. As mentioned above, the drain wire must be attached to Ground on the controller side, which is the V- terminal or negative of your power supply. 2 6-050800 X2

Basic Access Control Using an Electromagnetic Lock (Maglock) If you aren t using door contacts you must short the white/orange and white wires. A fi ltered and regulated DC power supply is recommended. Basic Access Control Using an Electric Door Strike If you aren t using door contacts you must short the white/orange and white wires. A fi ltered and regulated DC power supply is recommended. 6-050800 X2 3

Integrated Access Control Wiring 232iLM Keypad Installation & Programming A fi ltered and regulated DC power supply is recommended. Wire Color Gray Blue Green Relay Connection Normally Closed Common Normally Open 4 6-050800 X2

Wiring the Bell Output to a Speaker: The SSWiLM keypad has a built in bell button, which triggers a relay output when pressed. This relay is normally open and the contact closes when triggered. You can use this relay output to trigger devices that require a momentary closure, such as a doorbell. The relay output provides a dry contact, but you can run up to 24 VDC or 125 VAC through it for devices that require power to operate. The diagram below shows these connections. Keypad Mounting Height Mounting height can vary depending on requirements. An appropriate range is typically between 48 and 52 inches on center off the fl oor. 6-050800 X2 5

Programming the 232iLM Keypad 232iLM Keypad Installation & Programming The SSWiLM keypad has it s own local programming options. All user codes and other access control features are programmed into the controller. Refer the Self-Contained Access Control Programming Guide for those features. The programming options chart below shows all the programming commands available in the SSWiLM. To program the SSWiLM you fi rst must enter program mode. To enter program mode enter the following on the keypad: 099 # program code (default program code is 6789). Keypad Default Settings Option Default Setting Option Default Setting Local Program Code 6789 Audio Keypress Feedback Enabled Visual Keypress Feedback Enabled Door Bell Select Continuous Keypad Illumination Enabled Keypad Dimming Enabled Programming Options Chart Command/Action Keys to Enter/Details Command 90 Change Local Program Code 90 # 0 # 0 # new code new code (default = 6789) Command 91 Set/Clear Keypad Options 91 # option # set/clear # (options below, defaults in bold) Option Clear Set 0 Visual Keypress Feedback 0 = Disabled 1 = Enabled 1 Audio Keypress Feedback 0 = Disabled 1 = Enabled 11 Keypad Illumination 0 = Disabled 1 = Enabled 12 Keypad Dimming 0 = Disabled (always bright) 1 = Enabled 13 Door Bell Select 0 = Disabled 1 = Enabled Command 92 92 # 4 # time # Set timed output (1 99 seconds) Set Door Bell Duration 92 # 4 # 0 # Set to continuous Command 96 Reset Keypad to Default Settings 96 # 0 # 0 # Exit Program Mode Press the Key Testing the Keypad After installing the keypad, it is recommended that you perform the keypad self-test once a year, to ensure that the keypad is working properly. To perform the self-test, with the unit powered up, press the following keys on the keypad: 7890 # 123456 If all 12 keypresses are accepted, the keypad enters self-test mode. The LEDs alternate three times followed by the sounder beeping three times. When fi nished the yellow LED starts fl ickering rapidly. Press to clear. 6 6-050800 X2

LED Indications LED State Red Solid Green Solid Yellow Solid Yellow Flashing Slowly (single fl ash) Yellow Flashing Slowly (double fl ash) Yellow Momentary Flash Description Door Locked Door Unlocked Programming Error Controller Program Mode Front End Program Mode Visual Keypress Feedback Replacing the 232m (discontinued) with an 232iLM The 232iLM is functionally equivalent to the 232m keypad, which was discontinued. It s not, however, a direct physical replacement. They are both two piece units, but they use a different control boards. It is not possible to replace just the mullion keypad portion of the unit. You must replace the entire unit. Refer to the previous sections for wiring your new 232iLM unit. Program Mode Loopback If you ve forgotten the local program code use the following loopback connection to enter program mode. Power down the unit, short the wires in the confi guration illustrated, then power the unit back up. The yellow LED should be fl ashing. Now change your local program code or reset the unit. Power the keypad down and reconnected the wire harness in the original confi guration. Limited Warranty This Nortek Security & Control product is warranted against defects in material and workmanship for twenty four (24) months. This warranty extends only to wholesale customers who buy direct from Nortek Security & Control or through Nortek Security & Control s normal distribution channels. Nortek Security & Control does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer s warranty, if any. There are no obligations or liabilities on the part of Nortek Security & Control LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Nortek Security & Control LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Authorization Number (RA#). Contact Returns at 1-855-546-3351 for an RA# and other important details. Technical Support DEALERS/INSTALLERS ONLY! End users must contact the dealer/installer for support. If the keypad still does not work after troubleshooting, please call the Technical Services department at 1-800-421-1587. 6-050800 X2 7

232ilM Mounting Template Copyright 2015 Nortek Security & Control LLC 8 6-050800 X2