Siemens AG 0 Overview is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms. Benefits Monitoring and control in one device Integral telemetry interface (Modbus RTU/ASCII) Patented algorithm for calculation of pumped volume within % accuracy Logging of pump runtime and number of pump starts Expandable with I/Os, RAM for data logging, dual point, SmartLinx communications, and RS interface Simple system configuration and diagnostics with Siemens Dolphin Plus Windows-based software AC or DC power supply is available for rack mount, panel mount or Application It combines non-contacting ultrasonic technology, patented echo-processing techniques and proven application software to provide accurate level monitoring in liquids up to m (0 ft). It also effectively monitors flow in flumes, weirs and open channels. Five relays control any combination of pumps, gate valves and alarms. Further advantages include fault signaling and data logging for trend analysis. It can log the time, date and volume of up to 0 occurrences of combined sewer overflows (CSO). The basic device has digital inputs, digital outputs, analog input, ultrasonic level point, differential/average capability and one RS interface with Modbus RTU/ASCII protocol. The device can be expanded by additional I/Os, more RAM, two channels, RS or SmartLinx communications models as your needs grow. It integrates seamlessly with SCADA or DCS systems or a PLC system to provide remote access to all system parameters (pumped volume, pump runtime, pump status). The integral telemetry interface (Modbus RTU/ASCII) allows remote control in real time. Key Applications: wet well/lift station control, weirs/flumes, open channels Application of accessories can be expanded to meet the requirements of a variety of applications. Auxiliary I/O cards, RAM and data logging, dual-channel function and SmartLinx communications. Input/output cards A single auxiliary I/O card can be installed in the. The following I/O cards are available: - analog inputs/ analog outputs - analog inputs - analog outputs - digital inputs - digital inputs/ analog inputs/ analog outputs ( only) Expanded memory card The available RAM can be increased using this card. The data logging function is then available. Two-channel function A second measuring point is provided on the SITRANS LUC00 to permit dual-channel measurements. This function is made available by ordering a software access code. Please contact your Siemens representative for details. Communications The is offered with Modbus RTU/ASCII as a standard feature. Further industrial communications protocols are available with the addition of an optional SmartLinx card. The following protocols are currently available: - PROFIBUS DP - Allen Bradley Remote I/O - DeviceNet Siemens FI 0 0 /
Siemens AG 0 Technical specifications Mode of operation Measuring principle Ultrasonic level measurement Measuring range 0.... m (... 0 ft) Measuring points or Output Ultrasonic transducer khz Relays relays, rated A at 0 V AC, non-inductive Wall Mount version: SPST Form A relays, SPDT Form C relay Rack and Panel Mount version: SPST Form A relays, SPST Form B relay Accuracy Error in measurement 0. % of range or mm (0. inch), whichever is greater Resolution 0. % of measuring range or mm (0.0 inch), whichever is greater ) Temperature compensation -0... 0 C (-... 0 F) Integral temperature sensor External TS- temperature sensor (optional) Programmable fixed temperature Rated operating conditions Ambient conditions Ambient temperature for enclosure -0... 0 C (-... F) Design Rack mount Panel mount Weight (rack and panel mount) Weight () Communications RS DIN HU/ pitch, -rail plug-in unit suitable for standard HU/ pitch (9") rack Suitable for standard panel cutout DIN 00 x mm, 0 mm (. inch) center height. kg (. lb). kg (. lb) Siemens Dolphin protocol, Modbus RTU and ASCII Option SmartLinx compatible, RS Power supply 00... 0 V AC ± %, 0/0 Hz, VA ( W) or... 0 V DC, 0 W Ultrasonic transducer Compatible transducers: ST-H and EchoMax series XPS-0/0F, XPS /F, XCT-, XCT- and XRS- ma output signal -core copper conductor, twisted, shielded, 0.... 0. mm² (... AWG), Belden 0 or equivalent is acceptable Displays and controls Rack and panel mount x 0 mm ( x 0. inch) LCD (selectable backlighting) Wall mount 00 x 0 mm ( x. inch) multifield LCD, backlit Programming Using removable handheld programmer (ordered separately) or Dolphin Plus software (option) Memory Mbyte RAM (static) with battery, Mbyte flash EPROM Certificates and approvals CE, FM, CSA ) The measuring range corresponds to the distance from the zero point to the sensor face, plus any range extension (P0) / Siemens FI 0 0
Siemens AG 0 Selection and Ordering data A complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms. ML00- - A Mounting Panel mount version Rack mount version for 9" rack Wall mount, standard enclosure Wall, entry, M0 (valid with approval option only) Input voltage 00... 0 V AC A... 0 V DC B Number of measurement points Single point version A Dual point version B Data communications SmartLinx ready, no module 0 SmartLinx PROFIBUS DP module SmartLinx Allen-Bradley Remote I/0 module SmartLinx DeviceNet module Protocol Modbus RTU/ASCII Auxilliary memory None 0 Mbyte static RAM, including data logging module Auxilliary I/O None A analog inputs and analog outputs B analog inputs C analog outputs D digital inputs E digital inputs, analog inputs and analog F outputs (only for ) Approvals CSA, CE, UL (not available with mounting option ) CE Selection and Ordering data Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [9 x 0 mm (. x.9 inch)]: Measuring-point number/identification (max. characters) specify in plain text Operating Instructions English German Note: The Operating Instructions should be ordered as a separate item on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and Operating Instructions library. Other Operating Instructions SmartLinx Allen-Bradley Remote I/O, English SmartLinx PROFIBUS DP, English SmartLinx PROFIBUS DP, German SmartLinx PROFIBUS DP, French SmartLinx DeviceNet, English Note: The appropriate SmartLinx Operating Instructions should be ordered as a separate line on the order. Order code Y ML99-GL0 ML99-GL ML99-AP0 ML99-AQ0 ML99-AQ ML99-AQ ML99-BH0 Accessories Handheld programmer ML0-AG ERS00 Configuration Tool software, CD, cable kit, ML90-AE and License ERS00 Configuration Tool software, License only ML90-AF ERS00 Configuration Tool software, demo CD only ML90-AG M0 cable gland kit ( M0 cable glands, ML90-FV M0 nuts, washers) See SmartLinx product page / for more information. Tag, stainless steel, x mm (0. x. inch), ML90-AC one text line, suitable for enclosures Sunshield kit, 0 SS ( only) ML90-GA SITRANS RD00 Remote display - see Chapter SITRANS RD00 Remote display - see Chapter SITRANS RD00 web, datalogging, alarming, ethernet, and modem support for instrumentation - ML0- AA00-0 see Chapter Auxiliary Cards. Access code required ) MByte static RAM extended memory PBD:000 analog input / analog output for rack and PBD:009 panel mount version analog input / analog output for PBD:00 version digital input for rack and panel mount version PBD:00 digital input for version PBD:00 analog input for rack and panel mount version PBD:00 analog input for version PBD:00 analog output for rack and panel mount version PBD:00 analog output for version PBD:00 digital inputs, analog inputs, analog outputs, PBD:0 Access code, dual point capability ML0-KA Auxiliary Cards ) MByte static RAM extended memory ML0-KR analog input / analog output for rack and ML0-KS panel mount version analog input / analog output for ML0-KT version digital input for rack and panel mount version ML0-KU digital input for version ML0-LA analog input for rack and panel mount version ML0-LB analog input for version ML0-LC analog output for rack and panel mount version ML0-LD analog output for version ML0-LE digital inputs, analog inputs, analog outputs, ML0-LF ) Values of parameters P and P must be obtained from the customer in order to generate the order for the access code. ) For replacement of auxiliary card or spare auxiliary card. Access code not required. Must be used only as replacement cards. Siemens FI 0 0 /9
Siemens AG 0 Dimensional drawings Rack mount unit HP (0.) (.9) U Panel mount unit 0 (.) (.) (0.) 9 (.) Terminal board extends beyond panel faceplate Mounting bracket hand tighten ( in. lb. torque max.) Wall mount unit 0 (.0) (.) (.) (.) (0.) (.) (.0) 09 (.) Mounting holes ( places), dimensions in mm (inch) /0 Siemens FI 0 0
Siemens AG 0 Schematics Rack and panel mount RELAY RELAY RELAY 9 RELAY 0 RELAY 9 0 V V DIGITAL INPUTS TS- ma I/P 9 SHIELD SHIELD 0 9 0 SEE SMARTLINX CARD INSTRUCTION MANUAL 00W 9 0 DIGITAL INPUTS DCD RXD TXD DTR SG DSR RTS CTS SYNC RS SEE EXPANSION I/O CARD INSTRUCTION MANUAL 9 0 9 0 See note AC Version L/N L DC Version -0V See note Notes. Transducer uses wire twisted pair with shield only.. Terminals 9- are for use with optional expansion I/O cards. Wall mount 0 0 0 0 0 0 0 0 09 0 A B A B Optional ma input card shown. Other expansion cards I/O available - see options list. RS- AC version 0 L/N 00-0 V L DC version 0-0 V SMARTLINX SL SL SL SL SL SL SL SL SL9 9 SYNC 0 TB DCD 9 RXD 0 TXD DTR SG DSR RTS CTS V TB RS V 9 0 9 0 TB TB 9 0 TS- connections Siemens FI 0 0 /