Product Manual for the Mini Industry Meter MIZ Installation I Device description I Operation

Similar documents
NXT4 Three phase meter for commercial, industrial and advanced residential applications

LZQJ-XC Digital 4-Quadrant/Combi meter

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

EngyVolt RV12 and RV15

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

PHOENIX CONTACT - 07/2006

QUINT-PS/ 1AC/24DC/ 5

Installation and Operating Instructions

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

ANLEITUNG / MANUAL EMU ALLROUNDER EMU PROFESSIONAL. Quality that counts. Made in Switzerland

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Electronic Temperature Controller. Instruction Manual Version

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

AB Axis Industries. Use

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

QUINT-PS AC/24DC/10

E350 series 2. ZCF100Ax/Cx s2. Technical Data. Electricity Meters IEC/MID Residential

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

A2000 Multifunctional Power Meter

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

PRO-1250D CT MID DIN rail three phase four wire energy meter.

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I(-SP)(-NC)

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Power supply module, bus connection module

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

TRIO-DIODE/12-24DC/2X10/1X20

Extract from the online catalog

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

AI561 Analog Input Module

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PRO2DM DIN rail single phase two wire energy meter

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

STEP-PS/1AC/24DC/1.75

ME162 Single-Phase Electronic Meter

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

/ Type approved according to:

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

CEM-C30 INSTRUCTION MANUAL (M017B A)

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. Technical Data

Power Supply HARTING pcon

Ultra Slim Relays 24

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

CEM-C6 INSTRUCTION MANUAL (M187B B)

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Interface Module XC Level Converter / User Manual

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Operating instructions. Speed monitor D / / 2014

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

RESIDENTIAL ZMF100AC, ZMF100AB, ZFF100 TECHNICAL DATA. IEC-specific data Current Base current I b. Measurement Accuracy. Measurement Behaviour

Operating instructions. Switching amplifier DN0210 DN / / 2015

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

OB735 Smart Energy Meter

MINI MCR-SL-PT100-UI(-SP)(-NC)

Operating instructions. Standstill monitor A / / 2011

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

QUINT-BUFFER/24DC/24DC/40

COUNTIS ATv2/ATiv2 GB

MINI MCR-SL-UI-REL(-SP)

PSR DC/ESP4/2X1/1X2

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

DC561, digital input/output module,

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

Operating Instructions VEGAMET 381

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

MIC-2 Multi-instrument DATA SHEET

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

MID approval no. DE-08-MI004-PTB004 Date of release

PHOENIX CONTACT - 12/2007

SD1. Differential Controller. Operating and Installation Instructions F2 72.3

PRO-75 SERIES. User manual

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

ISOMETER isopv with coupling device AGH-PV

CU port USB 2.0 hub. Version: 1.1 Date:

ASI QUINT /2.4 EFD

Digital input modules

Operating Instructions

Transcription:

Product Manual for the Mini Industry Meter MIZ Installation I Device description I Operation Edition: 25.06.2009 MIZ-PHB-E-1.00

The contents of this manual are protected by copyright. It is forbidden to translate, reprint, copy or store the contents in electronic data processing systems without the express permission of the EMH. All trade marks and product names mentioned in this manual are the property of the EMH metering GmbH & Co. KG or the respective title holder. EMH is certified in accordance with DIN EN ISO 9001:2008 and endeavour to improve their products continually. The contents of this manual and the technical specifications may be supplemented, amended or deleted without prior notice. The description for the product specification in this manual does not constitute an integral part of the contract. 2012 EMH metering GmbH & Co. KG. All rights reserved. If you have any questions or suggestions, you can contact us at: EMH metering GmbH & Co. KG Neu-Galliner Weg 1 19258 Gallin GERMANY Tel.: +49 38851 326-0 Fax: +49 38851 326-1129 E-mail: Web: info@emh-metering.com www.emh-metering.com Technical Support: Tel.: +49 38851 326-1930 E-mail: support@emh-metering.com 2

Table of contents 1 Prologue... 5 1.1 Safety tips... 5 1.2 Maintenance- and guarantee tips... 5 2 Mounting and installation... 5 2.1 Mounting the meter... 5 2.2 Installation... 6 3 General description... 6 4 Standards and regulations... 7 5 Housing-, operation and display elements... 8 5.1 Front view... 8 5.2 Side view... 8 5.3 LC-Display... 9 5.3.1 Description of the display... 9 5.3.2 Displays... 10 6 Technical description... 11 6.1 Technical data... 11 6.2 Function circuit diagrams... 12 6.3 Power supply... 12 6.4 Output... 12 6.5 Test-LED... 12 6.6 M-Bus-interface (only with Premium -version)... 12 7 Operation of the meter (only with Premium -version)... 13 7.1 Display control... 13 8 Operating conditions... 13 8.1 Standard operation mode... 14 8.2 Primary M-Bus-address (only with Premium -version)... 14 8.3 Baud rate M-Bus (only with Premium -version)... 14 8.4 Test mode (for certification only and only with Premium -version)... 14 9 EC Declaration of conformity... 15 3

Figure index Figure 1: Dimensions... 5 Figure 2: Back-up fuse... 6 Figure 3: Housing-, operation and display elements: front view... 8 Figure 4: Housing-, operation and display elements: side view... 8 Figure 5: Layout of the display... 9 Figure 6: Function circuit diagrams... 12 Table index Table 1: Terminal dimensions, connection-cross sections, torques... 6 Table 2: Features... 7 Table 3: Housing-, operation and display elements: side view... 8 Table 4: Description of the display elements... 9 Table 5: Displays... 10 Table 6: Technical data... 11 Table 7: Specifications of the outputs... 12 Table 8: Error code description... 13 Abbreviations A Active energy +A Positive active energy (customer imports from utility) Cl. Accuracy class DIN Deutsches Institut für Normung e.v. (German Institute for standards) EN European standards EVU Utility IEC International Electromechanical Commission Imp. Impulse Imp./kWh Impulse per kwh L External conductor LED Light Emitting Diode N Neutral conductor P Active power +P Active power (customer imports from utility) PTB PTB (German certified body) S0 Interface accord. to DIN 43 864 4

1 Prologue This manual describes all designs of the meter. It is therefore possible that meter features are described here which do not apply to the meter(s) used by you. 1.1 Safety tips The meters are to be used exclusively for measuring electrical energy and must only be operated within the specified technical data (see also nameplate). When installing or changing the meter, the conductor to which the meter is connected must be de-energised. Only the intended screw terminals may be used for this. Contact to parts under voltage is extremely dangerous. Therefore the relevant back-up fuse is to be removed and stored so that other people cannot insert this unnoticed. The local standards, guidelines, regulations and instructions are to be obeyed. Only authorized personnel are permitted to install the electricity meters. 1.2 Maintenance- and guarantee tips The meter is maintenance-free. With damages (e.g. due to transportation, storing) no repairs may be carried out independently. As soon as the meter is opened, the guarantee claims cease. The same applies in case the defect can be traced back to external influences (e.g. lightning, water, fire, extreme temperatures and weather conditions, improper or negligent use or treatment). 2 Mounting and installation 2.1 Mounting the meter The meter is designed for mounting on DIN-rails TH 35-7.5 accord. to DIN 60715. Figure 1: Dimensions 5

2.2 Installation When connecting the meter, please pay careful attention to the relevant connection diagram which you can find collateral of the Meter When installing the meter, after threading the connecting leads, please pay attention that the screws are tightened to the relevant torque (according to EN 60999) to guarantee a safe contact. The torque depends on the type of the connecting leads and the maximum current. To avoid damaging the meter do not exceed the valid, maximum torque for the terminal clamps! Note: The meter must be secured with an overcurrent protection device of 25 A or 32 A, depending on the meter type. Figure 2: Back-up fuse Current terminals Auxiliary terminals Terminal dimensions W x H (d) mm Maximum connection- cross section (mm²) Maximum torques for terminals (Nm) d = 4 d = 2,5 6 2,5 1,7 0,5 Table 1: Terminal dimensions, connection-cross sections, torques 3 General description The MIZ is a digital single tariff meter for measuring positive active energy in 2-wire networks. These meters are principally used for energy data registration in the industry and building installation, switching stations and the field of utilities. The compact design of this meter allows space saving mounting (only 1 pitch wide). The meter has a 6-digit LC-display. The energy consumption values are displayed with 5 integer digits and 1 decimal digit. They can, however, also be given out via a pulse output (max. 27 V DC, 27 ma) and/or via an electrical interface (M-Bus, according to EN 13757-2, -3). The pulse constant (5 000 Imp/kWh) and the pulse length (50 ms) are fixed. The meter corresponds to the accuracy class B according to EN 50470-1, -3. 6

Features of the MIZ Silver Gold Premium Current 0,25-5(25) A 0,25-5(32) A 0,25-5(32) A Instantaneous values no yes yes M-Bus-interface no no yes Operation button no no yes Display lighting no no yes Table 2: Features 4 Standards and regulations DIN 43864 EN 13757-2, -3 EN 50470-1 EN 50470-3 DIN EN 60529 Electricity meters; current interface for pulse transmission between pulse meters and tariff device Communication systems for meters and remote reading of meters (M-BUS) (Compatible extension of EN 1434-3:1997) Electricity metering equipment (a.c.) - Part 1: General requirements, tests and test conditions - Metering equipment (class indexes A, B and C) Electricity metering equipment (a.c.) - Part 3: Particular requirements - Static meters for active energy (class indexes A, B and C) Degrees of protection provided by enclosures (IP code) DIN EN 60715 Dimensions of low-voltage switchgear and control gear - standardized mounting on rails for mechanical support of electrical devices in switchgear and control gear installations DIN EN 61000-3-2, 4-2, -4-3, -4-4, -4-5, -4-6, -4-11, -6-2 IEC 62052-11 Electromagnetic compatibility (EMC) Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 11: Metering equipment 7

5 Housing-, operation and display elements 5.1 Front view Neutral wire S0-output Call-up button for the appliance of meters Unit of the energy value LC-display Serial number Test-LED M-Bus-interface Line input Line output Figure 3: Housing-, operation and display elements: front view 5.2 Side view Figure 4: Housing-, operation and display elements: side view No. Description 1 Type designation / Type key 2 Voltage, current, frequency 3 Accuracy class, temperature code, contact sequence number 4 Model year CE sign, metrology mark + year of the conformity valuation, designation 5 of the notified body 6 Examination certificate number acc. to EC type-examination certificate 7 Pay attention to package insert 8 Class of protection II 9 Non-reverse ratchet 10 Type of network and load 11 Connection diagram Table 3: Housing-, operation and display elements: side view 8

5.3 LC-Display 5.3.1 Description of the display The meter has a liquid crystal display (LCD) with the following layout: Figure 5: Layout of the display No. Description 1 Circle-Symbol Flashes when communication with the M-Bus-interface 2 Star-Symbol Flashes together with the Exclamation-Symbol in the Test mode 3 Exclamation-Symbol Flashes of negative energy direction (Non-reverse ratchet, Installation check) 4 Display of the units Unit of the displayed value in the value range Note: The energy value is no indication of the unity displayed kwh 5 Value range Display the contents of the register Table 4: Description of the display elements 9

Scrolling list 5.3.2 Displays Display Description Duration of display Availability Silver Gold Premium Display test Firmware-version All display segments flash after start-up for 6 s Appears for 5 s Check sum Code Appears for 5 s Error display Energy value Appears for 60 s if an error occurs Appears for 10 s (in case of error only 2 s) Instantaneous power Instantaneous voltage Instantaneous current Network frequency Power factor Primary M-Bus-address Secondary M-Bus-address MSW (most significant word) = 4 most significant digits LSW (least significant word) = 4 least significant digits Baud rate M-Bus Every value appears for 2 s Firmware version Display test Test mode start (Call-up list standard mode) Test mode close (Call-up list test mode) Table 5: Displays 10

6 Technical description 6.1 Technical data Voltage 2-wire meter 230 V Current Starting current Frequency 0,25-5(25) A or 0,25-5(32) A 20 ma 50 Hz Accuracy active energy Cl. B accord. to EN 50470-1, -3 Measuring types active energy +A Meter constants LED 5 000 Imp./kWh Energy registers Data retention time output Display version LCD number of digits 6 digitness 5,1 digit size in the value range display of instantaneous values 1 000 Imp./kWh 1 tariff register without voltage in the FLASH / EEPROM, at least 20 years approx. 2,7 x 6,25 (W x H) mm scrolling Operation (option) operation button for operation of display Data interfaces (option) M-Bus accord. to DIN EN 13757-2, -3 (300...9600 baud) Output number 1 S0 pulse length max. 27 V DC, 27 ma (passive) 50 ms Energy supply capacitor power supply from the measuring voltage Power consumption voltage path < 0,4 W EMC-characteristics isolation resistance isolation: 4 kv AC, 50 Hz, 1 min surge voltage EMC: 4 kv, impulse 1,2/50 s, 2 resistance against HF-fields ISO: 10 V/m (under load) Temperature range specified operating range -25 C...+55 C limit range for operation, storage and transportation -40 C...+70 C 6 kv, impulse 1,2/50 s, 500 Relative humidity 95%, non-condensing accord. to IEC 62052-11, EN 50470-1 and IEC 60068-2-30 Housing dimensions DIN 43880 (1 pitch wide = 18 mm) Weight class of protection degree of protection housing, terminals: IP 20 material II polycarbonate glass-fibre-reinforced fire characteristics accord. to IEC 62052-11 approx. 67,5 g Connection-cross section current- / neutral conductor max. 6 mm 2 Further features Table 6: Technical data auxiliary terminals max. 2,5 mm 2 measuring of instantaneous values power, voltage, current, frequency and power factor 11

6.2 Function circuit diagrams Figure 6: Function circuit diagrams 6.3 Power supply The MIZ is supplied by a capacitor power supply and is short circuit-proof. Available voltage versions: 230 V, 2-wire 6.4 Output The MIZ has a potential free S0-output (acc. to DIN 43864) which is designed as maker contact. Specification S0 max. 27 V DC, 27 ma (passive) Table 7: Specifications of the outputs The impulse length is 50 ms with an pulse value of 1 000 Imp./kWh. 6.5 Test-LED The test-led is used for output of energy proportional active energy pulses and for the display of start-up and no load operation. The LED constant is 5 000 Imp./kWh in the standard mode and in the test mode 50 000 Imp./kWh, the pulse length is 50 ms. If the meter below the start-up threshold the LED lits continuously. Above its start-up threshold, the meter displays energy proportional pulses. 6.6 M-Bus-interface (only with Premium -version) The M-Bus interface is designed accord. to DIN EN 13757-2, -3. Via M-Bus the following parameters can be transmitted: - Manufacturer identification - Medium 2 (electricity) - Primary- and secondary addresses M-Bus - Energy value - Instantaneous value (P, U, I), Frequency, Power factor, Operation time - Error status - Baud rate 12

7 Operation of the meter (only with Premium -version) The display in the Premium -version of the MIZ can be additionally controlled via mechanical button (Call-up button). 7.1 Display control When the call-up button will be pressed, the meter will be switched automatically to the display of the energy value or if there is an error, the meter will be switched to the error display. The lighting of display will be activated. After the expiration of 15 seconds without operation, the display backlight will be switched to half intensity. The following applies for operation of the meter via the call-up button: - Short keypress (t < 2 s): switches over to the next value of the list - Long keypress (2 s < t < 5 s): activation of a menu-point - Longest keypress (t > 5 s): back to the standard display During normal operation the meter is in the standard mode. If the meter is in a different condition, 5 minutes after the last operation of the button the display will automatically returns to the standard display 8 Operating conditions The data are saved every 24 hours. The operating hours counter registers expired hours of continuous operation. In case of voltage return and every hour during operation the meter carries out checks of: - Check sum about the firmware - Check sum about the parameter data - Check sum about the settable data (M-Bus-data, only with the Premium -version) If an error appears during this check, an error code will be shown in the display. Error code Explanation Silver Gold Premium F:F:0001 Checksum of the firmware is incorrect F:F:0002 F:F:0003 Checksum of the parameterisation data is incorrect Checksum of the parameterisation data and of the firmware is incorrect F:F:0004 Checksum of the changeable data is incorrect F:F:0005 F:F:0006 F:F:0007 Checksum of the changeable data and of the firmware is incorrect Checksum of the changeable data and of the parameterisation data is incorrect Checksum of the changeable data, of the parameterisation data and of the firmware is incorrect Table 8: Error code description If an error is shown, the meter is not allowed to be used for billing purposes. The reset of the error code only can be made at the factory. 13

8.1 Standard operation mode During normal operation the meter is in the standard operation mode. 8.2 Primary M-Bus-address (only with Premium -version) If A1:000 appears in the display, the menu for setting the M-Bus-address can be activated via long keypress (2 s < t < 5 s). A1 starts to flash in the display. There are two possibilities to set the primary address: a) Short press on the Call-up button (t < 2 s) = value increases by 1 or b) Long press on the Call-up button (t > 2 s) = value increases by 10 at an interval of 0,5 s If the maximum value of 250 is reached, it is reset to 0. Note: After entering the primary address, the call-up button may not be used for the next 6 s. If the entered primary address flashes, you can continue as follows: a) Short keypress (t < 2 s) = enter of a new value, A1 flashes in the display or b) Long keypress (2 s < t > 5 s) = value acceptance and return to the standard display or c) Longer keypress (t > 5 s) = reject of the entered value and return to the standard display When the call-up button will not be pressed after 5 minutes of input of the primary address, it will be rejected and the display will be switched automatically back to the default display. 8.3 Baud rate M-Bus (only with Premium -version) If bd:2400 appears in the display, the menu for setting the baud rate can be activated via long keypress (2 s < t < 5 s). bd starts to flash in the display. Via short keypress the next value of the list (300 2400 9600) will be shown. The acceptance of the baud rate takes place via long keypress (2 s < t > 5 s). If the button will be pressed longer (t > 5 s), the selected baud rate will be rejected. In both cases the reset to the standard display will be carried out. When the call-up button will not be pressed after 5 minutes of input of the baud rate, it will be rejected and the display switched automatically back to the default display. 8.4 Test mode (for certification only and only with Premium -version) The test mode is only for testing and inspecting purposes and is only available with the Premium -version. If the meter is in the test mode, the star symbol and the exclamation symbol flash. The test mode will be activated as follows: 1. automatically after successful adjustment or 2. from the standard operation mode via call-up button in the menu GotESt. In the test mode the impulse constant is 10 times higher. The impulse length is 3 ms. The test mode will be closed as follows: 1. via the Call-up button in the menu item ESCAPE in the standard operation mode or 2. automatically after 10 s undervoltage of all phases (70% U Nenn) or 3. automatically after 72 hours continuous operation, if the test mode has been activated after adjustment 4. automatically after 12 hours continuous operation, if the test mode has been activated via standard operation mode 14

9 EC Declaration of conformity acc. to EMC Directive 2004/108/EC acc. to Measuring Instruments Directive 2004/22/EC The manufacturer EMH Elektrizitätszähler GmbH & Co KG Südring 5 19243 Wittenburg GERMANY certifies that the following product Product designation: Type designation: Electricity meter MIZ conforms to above mentioned directives, including all amendments, which are valid at the moment of issuing this declaration. The conformity of the type-examination with the listed standards below was ascertained: Notified body: 0102 Examination certificate number: DE-08-MI003-PTB015 The following harmonized standards are in use: acc. to EMC Directive 2004/108/EC: acc. to Measuring Instruments Directive 2004/22/EC: EN 55022:2006 50470-1:2006 EN 62052-11:2003 50470-3:2006 EN 62053-21:2003 Place, Date: Wittenburg, 19.12.2008 Dipl.-Ing. Norbert Malek Managing director 15