SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

Similar documents
7800 SERIES S7810B Multi-Drop Switch Module

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules

S7999D SOLA Operator Interface Display

T775S Series 2000 Expansion Module

SYSNet QS7700A Network Interface ControlBus Module for BCS7700

rcc.1081 Installation Instructions

Installing the Tracer MP503 Input/Output Module Ordering number: ,

PanelView Plus/VersaView CE Terminals and Display Modules

Tempco Instruction Manual

SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings

Infosystem Remote Touchscreen Installation Instructions

ACCESS 9340/9360 Meter Input/Output Module

DS A MN LCD I/A SERIES MICRONET LCD APPLICATION SPECIFICATION

Control different load types with one device

High Speed Remote I/O Module

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Analog Voltage Combination Module

NSD/M1 Installation Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

DS A 10/99 MN 500 I/A SERIES MICRONET MN 500 CONTROLLERS APPLICATION SPECIFICATION

S8VE (60/90/120/180/240-W Models)

EX-RC1 Remote I/O Adapter

SmartVFD Disconnect Panel Assemblies

A7800A1010 Tester for the 7800 SERIES System With Valve Proving Systems

PACSystems RX7i IC698CHS009/119

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Honeywell Model 700/800 Signal Processor and Viewing Head

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Voltage Current Front-mounting bracket

Rack Input Module Installation Instructions

Installation Job Aid for Ethernet Routing Switch 3600 Series

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

CTR21, CTR22, CTR23, and CTR24 Wall Modules

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

EX-RC1 Remote I/O Adapter

PV Rapid Shutdown device

PanelView 600 Terminals

RMB Peripheral Units Installation Guide

MicroTech II TM Remote I/O Panel Installation Manual

Satellite INSTALLATION GUIDE

PM Series Power Meter

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Surge Protective Devices. STV25K Series. Instruction Manual

IQ-SBS LCU Series Installation Instructions

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

PGR-3200 MANUAL INSULATION MONITOR

UC-2000 Installation Manual Unicorn Computers Technology Limited

FDS / FDS-R / FDS-PS

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Model 7705 Control Module

INSTALLATION INSTRUCTIONS

Broadband Automatic Disconnect Switch. User Manual

EX-RC1 Remote I/O Adapter

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

NCH-1000 (Multiple Breaker Types) Installation Instructions

P522 Signal Processor

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

CPCI-PS24 24V-Power Supply

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

NXCEX-6000 November 2, Series NXC20EX, and NXC40EX Servos for Class 1 Division 2. Hazardous Locations

CompactBlock Guard I/O EtherNet/IP Safety Modules

SLATE Low Torque Actuator Series FOR COMMERCIAL AND INDUSTRIAL MODELS

Control different load types with one device

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Model volt to 24 volt DC to DC Converter. Table of Contents. Introduction. 2. Specifications.. 2. Operation... 2

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

ENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

OPERATOR S MANUAL 9000U ISOLATOR

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Installation & Operation Manual

Level-Lance Model 5400A

Sylk I/O Devices APPLICATION FEATURES PRODUCT DATA

Quick Start Installation Guide

Solar Combiner Enclosure

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Switched Mode Power Supply Operating manual PAP800

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Transcription:

SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS

Scan for more information

Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can easily be customized for almost any requirement or application offering virtually limitless development opportunities with far less complexity. The R8001D4001 SLATE Digital I/O module is part of the SLATE Combustion System. The SLATE Digital I/O module offers a universal 14 opto inputs or 6 relays for a wide variety of applications needing additional logic. Features Automatically adapts to 24VDC or 24VAC to 240VAC (one voltage per module) Configurable input or relay output format Up to 14 opto inputs Up to 6 relay outputs Specifications Electrical Ratings: Voltage and Frequency: 24 VDC (± 15%), 24 VAC (± 15%), 50/60 Hz, 85-264 VAC, 50/60 Hz Maximum Total Connected Load: 2000 VA Fusing Total Connected Load: 15A Fast Blow, type SC or equivalent Environmental Ratings Ambient Temperature: Operating: -20 F to +150 F (-29 C to +66 C). Shipping: -40 F to +150 F (-40 C to +66 C). Humidity: 95% continuous, noncondensing. Vibration: 0.5G environment SLATE DIGITAL I/O MODULE 3 R8001D4001

Dimensions: See Fig. 1. Weight: 2 lb 1 oz (0.94 Kg) Approvals Underwriters Laboratories Inc. Listed, File: MP268 IRI Acceptable Federal Communications Commission: Part 15, Class A Must be mounted inside a grounded metal enclosure. Mounting DIN Rail (See Fig. 2) Required Components R8001A1001 SLATE Base Controller R8001S9001 SLATE Sub-Base Module 4 32-00008 01

7-3/32 (181) 2-11/16 (68) 4-19/32 (117) M35382 Fig. 1. Mounting dimensions of Digital I/O Module in in. (mm). Principal Technical Features The SLATE Digital I/O module offers a universal 14 opto inputs or 6 relays for a wide variety of applications needing additional logic. SLATE DIGITAL I/O MODULE 5 R8001D4001

LED Array There are four LEDs on the front of the digital I/O module that provide quick identification of system status and problems. This status is broadcast to other modules on the platform bus in case they are affected by the inoperable module(s). There are also nine banks of LEDs for the digital terminals. See Table 1 for descriptions. LED Color Description Power No light System does not have power Green System has power CPU Fault Red Green Red No light Table 1. LED Descriptions. No wire sheet or problem with the wire sheet Running Fault Running LED Display The SLATE system modules have a seven-segment, threeposition LED display used for indicating the module number of the SLATE system. The LED colors indicate the terminal state as shown in Table 2. Color Green Red No light Description Terminal is on Fault Not in use Table 2. Terminal LED Meanings. 6 32-00008 01

Select and Reset Buttons The SLATE system modules have a Select and Reset buttons located on the front of the module and beneath the segment display. The Reset button is used to clear a lockout and reset the module. The Select button is used to scroll through the segment display information. Installation WARNING Fire or Explosion Hazard Can cause severe injury, death, or property damage. Verification of safety requirements must be performed each time a control is installed on a burner to prevent possible hazardous burner operation. When Installing This Product 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. After installation is complete, check out the product operation as provided in these instructions. 4. The SLATE module must be mounted in an electrical enclosure with adequate clearance for servicing, installation and removal of modules. SLATE DIGITAL I/O MODULE 7 R8001D4001

WARNING Electrical Shock Hazard. Can cause severe injury, death or equipment damage. 1. Disconnect the power supply before beginning installation to prevent electrical shock and equipment damage. More than one power supply disconnect can be involved. M35383 Fig. 2. Installing the Limit Control Module on the Sub-Base Module. 2. Wiring must comply with all applicable codes, ordinances and regulations. 3. Wiring must comply with NEC Class 1 (Line Voltage) wiring. 8 32-00008 01

IMPORTANT 1. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause interference for radio communications. It has been tested and found to comply with the limits of a Class A computing device of part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference; in which case, the user, at their own expense, may be required to take whatever measures are required to correct this interference. 2. This digital apparatus does not exceed the Class A limits for radio noise, set out in the Radio Interference Regulations of the Canadian Department of Communications. Wiring WARNING Electrical Shock Hazard. Can cause severe injury, death, or equipment damage. Disconnect the power supply from the main disconnect before beginning installation to prevent electrical shock and equipment damage. More than one disconnect can be required. Terminal Description Rating 1 Unused --- 2 Unused --- 3 Unused --- 4 K1 Relay Dry Contacts 9.8 FLA, 58.8 LRA @ 120VAC, 4A (0.5 PF), 20A inrush @ 240VAC, 2A cont, 10A inrush @ 24VDC SLATE DIGITAL I/O MODULE 9 R8001D4001

Terminal Description Rating 5 K1 Relay Dry (see Terminal 4 above) Contacts 6 24VDC (0.5mA), 24-240VAC (0.2mA) 7 24VDC (0.5mA), 24-240VAC (0.2mA) 8 K2 Relay Dry Relay: 9.8 FLA, 58.8 LRA @ 120VAC, 4A (0.5 PF), 20A inrush @ 240VAC, 2A cont, 10A inrush @ 24VDC 9 K2 Relay Dry 10 K3 Relay Dry 11 K3 Relay Dry : 24VDC (0.5mA), 24-240VAC (0.2mA) (see Terminal 8 above) Relay: 9.8 FLA, 58.8 LRA @ 120VAC, 4A (0.5 PF), 20A inrush @ 240VAC, 2A cont, 10A inrush @ 24VDC : 24VDC (0.5mA), 24-240VAC (0.2mA) (see Terminal 10 above) 12 24VDC (0.5mA), 24-240VAC (0.2mA) 13 24VDC (0.5mA), 24-240VAC (0.2mA) 14 K4 Relay Dry Relay: 9.8 FLA, 58.8 LRA @ 120VAC, 4A (0.5 PF), 20A inrush @ 240VAC, 2A cont, 10A inrush @ 24VDC 15 K4 Relay Dry 16 K5 Relay Dry : 24VDC (0.5mA), 24-240VAC (0.2mA) (see Terminal 14 above) Relay: 9.8 FLA, 58.8 LRA @ 120VAC, 4A (0.5 PF), 20A inrush @ 240VAC, 2A cont, 10A inrush @ 24VDC : 24VDC (0.5mA), 24-240VAC (0.2mA) 10 32-00008 01

Terminal Description 17 K5 Relay Dry 18 K6 Relay Dry 19 K6 Relay Dry Rating (see Terminal 16 above) Relay: 9.8 FLA, 58.8 LRA @ 120VAC, 4A (0.5 PF), 20A inrush @ 240VAC, 2A cont, 10A inrush @ 24VDC : 24VDC (0.5mA), 24-240VAC (0.2mA) (see Terminal 18 above) 20 Vref+ 24VDC (0.1mA), 24VAC (0.1mA), 85 264VAC (0.2mA) 21 Unused --- 22 Vref- (see Terminal 20 above) Note: only one voltage can be used per module (same at all terminals). Table 3. Terminal Ratings. Application Line voltage terminals Communication Lines Other terminals Recommended Wire Size 14, 16 or 18 AWG copper conductor, 600 volt insulation, moisture-resistant wire. 22 AWG two-wire twisted pair with ground, or five-wire. 18 AWG wire insulated for voltages and temperatures for given application. Recommended Part Numbers TTW60C, THW75C, THHN90C Belden 8723 shielded cable or equivalent. TTW60C, THW75C, THHN90C Table 4. Recommended Wire Sizes and Part Numbers. SLATE DIGITAL I/O MODULE 11 R8001D4001

Recommended Grounding Practices Use an Earth ground or a signal ground as described below. Earth ground (Base, Rectification Flame Amp Module, other modules optional) 1. Use to provide a connection between the base and the control panel of the equipment. Earth ground must be capable of conducting enough current to blow the breaker in the event of an internal short circuit. 2. Use wide straps or brackets to provide minimum length, maximum surface area ground conductors. If a leadwire is required, use 14 AWG copper wire. 3. Make sure that mechanically tightened joints along the ground path are free of nonconductive coatings and protected against corrosion on mating surfaces. Signal ground Note the 18V system ground is not electrically connected to earth ground. Follow local codes and appliance recommendations to determine if this should be connected to earth ground. Recommended wire routing of leadwires Do not run high voltage ignition transformer wires in the same conduit with the flame detector or data lines. Do not route flame detector or data lines in conduit with line voltage circuits. Enclose flame detector leadwires without armor cable in metal cable or conduit. Follow directions in flame detector instructions. Be sure loads do not exceed the terminal ratings. Refer to the labels or terminal ratings in Table 3. The SLATE system must be mounted in an electrical enclosure. When mounting in an electrical enclosure, provide adequate clearance for servicing, installation and removal of SLATE modules. 12 32-00008 01

Maximum wire length: The maximum leadwire length is 300 feet to terminal inputs (Control, Running/Lockout Interlock) For remote reset leadwires, maximum length to remote pushbutton is 1000 feet. For Remote Bus data lines, maximum cable length depends on the number of modules connected, the noise conditions and the cable used. The maximum of all interconnecting wires is 4000 feet. SLATE DIGITAL I/O MODULE 13 R8001D4001

DIGITAL INPUT/OUTPUT MODULE 6 RELAYS 14 OPTO-INPUTS 1 2 3 4 K1 5 6 7 8 K2 9 10 K3 11 12 13 14 K4 15 16 K5 17 18 K6 19 20 VREF+ BIAS 21 22 VREF M35286 Fig. 3. Wiring diagram for limit control module. 14 32-00008 01

SLATE DIGITAL I/O MODULE 15 R8001D4001

32-00008-01 For more information and detailed instructions on the R8001D4001 and the entire SLATE system please refer to the SLATE User Guide located on our website at http://combustion.honeywell.com/slate Automation and Control Solutions Honeywell International Inc. U.S. Registered Trademark. 1985 Douglas Drive North 2014 Honeywell International Inc. Golden Valley, MN 55422 32-00008 01 M.S. 12-14 customer.honeywell.com Printed in U.S.A.