I/O module, digital and universal inputs, modu530

Similar documents
I/O module, universal, digital, S0 inputs, modu533

I/O module, digital outputs (relays), modu550

I/O module, digital outputs (open collector), modu551

I/O module, analogue outputs and universal inputs

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

EY-EM : Remote I/O module, ecolink

modu : Local override and indicating units

EY-AS 525: Modular automation station, modu525

EY-AS 524, 525: Modular automation station, modu524/525

EY-AS 524, 525: Modular automation station, modu524/525

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

EYE 200: DDC single-room controller, ecos200

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

EY-AS 521: Compact automation station, modu521

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

EY-RC 208, 209: Room automation stations, ecos208, 209

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

EY-SU 358: Push-button unit for room operating unit, ecounit358

EY-RU 355: Room operating unit, ecounit355

EY-RC 500: Room automation station, ecos500

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

modunet292: novanet-ethernet interface

EY-RU : Room operating unit with EnOcean wireless technology, ecounit

EY-RU : Room operating unit with EnOcean wireless technology, ecounit

ecounit : Room operating unit with EnOcean wireless technology

AVM 321, 322: Valve actuator

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

AVF 125S: SUT valve actuator with spring return

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Sauter Systems

Operating instructions. Speed monitor D / / 2014

EY-RC 311: Programmable controller, ecos311

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Operating instructions. Standstill monitor A / / 2011

Super universal modules

Extension module for lighting control

Operating instructions. Switching amplifier DN0210 DN / / 2015

Non-communicating room controllers

Digital input modules

AVM321S, 322S: Actuator SAUTER vialoq AVM 1000 with SAUTER Universal Technology (SUT )

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

AB Axis Industries. Use

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Cube67 - Modular I/O station

Automation stations compact model

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

AVM 105S, 115S: Valve actuator with SAUTER Universal Technology (SUT)

SSR - Supplies - Relays

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Resistance measuring module

Technical data. Safety notes. Product features

DESIGO 30 Remote operator terminal. for more then one HVAC systems en. menu + esc

EYL230: nova230, Compact universal automation station

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

02/11/2015

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

OP10. Pre-programmed, configurable controller for simple applications

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

MINI MCR-SL-PT100-UI-200

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Rotary version, three-position control

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Compact Universal Controllers

Priva Blue ID Digital input module DI4/DI8/DI16

VariTrans P Standard-Signal Isolators

Non-communicating room controllers

Universal Controller

Operating Instructions

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MID approval no. DE-08-MI004-PTB004 Date of release

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

KS 3012 PMA GENERAL DESCRIPTION

Technical data sheets

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. I/O expansion modules. Modules from the

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

SX90 Process Controller

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

AS-Interface I/O Module

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Modular controllers CECX

Transcription:

Product data sheet 92.031 EY-IO 530: I/O module, digital and universal inputs, modu530 How energy efficiency is improved SAUTER EY-modulo 5 technology: modular, fast and universal Features Part of the SAUTER EY-modulo 5 system family 16 inputs Power supply of modu525 automation station (AS) Pluggable element for extending the modu525 automation station Recording digital (alarm/status) and analogue inputs (Ni/Pt1000, U/I/R) in operational systems, e.g. in HVAC engineering Modular design (baseplate/electronics) Direct labelling on the front Can be equipped with a local indicating unit EY-IO530F001 Technical data Power supply Power supply From modu525 AS via I/O bus Power consumption1) 1.6 VA/0.65 W Power loss 0.65 W Current consumption2) 40 ma Operating temperature 0...45 C Storage and transport temperature 25...70 C Admissible ambient humidity 10...85% rh, no condensation Ambient conditions Inputs/Outputs Digital inputs 8 fixed assignment (alarm/status) Pulse counter 50 Hz Universal inputs 8 Analogue Ni1000/Pt1000, U/I/R, pot Digital DI (approx. 3 Hz) Fitting On top-hat rail Dimensions W x H x D 42 170 115 mm Weight 0.29 kg Connection for modu6 (LOI) 6-pin, integrated Connection, I/O bus 12-pin, integrated Connection terminals 24 (0.5...2.5 mm²) Type of protection IP 30 (EN 60529) Protection class I (EN 60730-1) Construction Interfaces and communication Standards and directives CE conformity as per Environment class 3K3 (IEC 60721) EMC directive 2004/108/EC EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 Overview of types Type Properties EY-IO530F001 I/O module, digital and universal inputs, modu530 1) 2) On the primary side of modu525 base station (230V~) Supply via modu525 base station Right of amendment reserved 2015 Fr. Sauter AG 3.1 1/6

Accessories Local operating and indicating units (LOI) Type EY-LO630F001 Components Type 16-LED indication, bi-colour 0920360003 24 V I/O module baseplate (pack of 3) 0929360530 Electronics module, modu530, 8 UI, 8 DI of operation Recording digital (alarm/status) and analogue inputs (Ni/Pt1000, U/I/R) in operational systems, e.g. in HVAC engineering The I/O module has a total of 16 inputs, of which 8 are digital inputs and 8 universal inputs. Intended use This product is only suitable for the purpose intended by the manufacturer, as described in the of operation section. All related product documents must also be adhered to. Changing or converting the product is not admissible. Engineering notes The modu530 I/O module is generally comprised of two components: the baseplate in which the I/O bus system and the connection terminals are integrated and the actual I/O module electronics. Fitting/assembly The baseplate of the I/O module is mounted in a cabinet using a top-hat rail (EN 60715) and connected on the side directly to the I/O bus of the modu525 AS or modules. This work must only be carried out in the de-energised state. The baseplate contains the bus module, which is responsible for power supply and continuous communication. This ensures that faults due to a failure or partial defect in the electronic component do not affect the function of other downstream modules. Removing/inserting the I/O module electronics from/to the baseplate is possible while the AS is in operation. To ensure plant safety and to avoid any faults at inputs or outputs, the I/O module electronics should only be removed or inserted while the base station is switched off. Labelling concept The I/O module can be labelled with a paper insert in the frontal transparent cap. There are specially perforated label sheets available for this purpose. The labelling is usually carried out using texts generated from CASE Suite, and the labels are printed on normal A4 paper using commercial printers. Assigning modules to AS The I/O module electronics are encoded on the hardware side using pin inserts so that only the appropriate baseplate can be used. The modu525 AS detects whether a module baseplate is plugged into the I/O bus. Baseplate number and assignment of module types for the I/O modules on the AS are defined with CASE Suite. This information is permanently stored in the AS. LED indicator/function The I/O module is equipped with a system LED that indicates the operating modes as follows: System LED LED I/O bus Status Indicator sequence No designation Continuous green light Module in operation Pulsating green º º º º º º Module not assigned with the base station Rapid pulsating red ººººººººººººººººººº AS in configuration, update or download Flashing red º º º º º º º º Module incorrectly assigned or internal error Flashing red º º º º º º º º AS in configuration, restart/download active Alternating green red off ºº ºº ºº ºº ºº Lamp test active (indicator type priority) No indicator No power supply 2/6 3.1 Right of amendment reserved 2015 Fr. Sauter AG

Digital inputs (DI fixed) Number of inputs Type of inputs Pulse counter Protection against external voltage Max. output current 8 (DI fixed) Potential-free contacts with ground connection Opto-coupler Transistor (open collector) 50 Hz (100 ms scan rate) ±30 V/24 V~ (without destruction) 1.2 ma to ground Scan rate 100 ms The binary information is connected between one of the input terminals (d0...d7) and the ground. The module applies a voltage of approximately 13 V to the terminal. If a contact is open, this corresponds to an INACTIVE state (bit = 0). If a contact is closed, there is an ACTIVE state (bit = 1) and 0 V is applied, giving a current of approximately 1 ma. Short-term changes of at least 20 ms between the station queries are saved briefly and processed at the next cycle. Every input can be defined individually as an alarm or a status through software parameter setting. With a local indicating unit (e.g. modu630 accessory) the digital inputs can be displayed. Pulse counters (CI with DI) At the digital inputs, counter inputs of potential-free contacts, opto-couplers or transistors with an open collector can be connected. The maximum pulse frequency may be up to 50 Hz. To ensure that switching contacts are recorded correctly, a debounce time of 5 ms is planned. Pulses can be captured on falling, rising or both switches. The minimum pulse time should be four times the debounce time. Universal inputs Number of inputs Type of inputs (software coding) Protection against external voltage Ni/Pt/U/R/Pot/DI I (channel u8, u9) Scan rate 100 ms Scan rate 500 ms Resolution Measuring ranges Voltage (U) Current (I) Potentiometer (Pot) 8 (UI) Ni1000 (DIN 43760) Pt1000 (EN 60751) Voltage measurement (U) Current measurement (I), channel u8, u9 only! Potentiometer input (Pot) Resistance (R) Digital input (DI) ±30 V/24 V~ (without destruction) +12 V/-0.3 V (without destruction) Channels u8, u12 Channels u9, u10, u11, u13, u14, u15 14 bit 0 (2)...10 V, 0 (0.2)...1 V 0 (4)...20 ma 0...1 (100%) with 3-wire connection (1 2,5 kω) Reference U ref 1,23 V (terminal no. 22) Resistance (R) Temperature Ni1000 Pt1000 Digital input Pulse counter Temperature measurement (Ni/Pt) > 1 kω, load max. 10 ma 200 2500 Ω -50...+150 C -50...+150 C Potential-free contacts with ground connection opto-coupler, transistor (open collector) approx. l out = 1.2 ma 3 Hz The Ni/Pt1000 sensors are connected using two wires between one of the input terminals for universal inputs (channel u8...u15) and a ground terminal. The inputs require no calibration and can be used directly. Line resistance of 2 Ω is pre-compensated as standard. With the correct line resistance of 2 Ω, (cable cross-section 1.5 mm²), the power cable (wire) may be no more than 85 m. Larger line resistances can be compensated by the software. The measurement current is pulsed to ensure that the sensor is not heated (l meas approx. 0.3 ma). Right of amendment reserved 2015 Fr. Sauter AG 3.1 3/6

Voltage measurement (U) The voltage to be measured is connected between an input terminal for universal inputs (channel u8...u15) and a ground terminal. The signal must be potential-free. The measuring ranges with or without offset 0 (0,2)...1 V or 0 (2)...10 V are selected through the software. The internal resistance R i of the input (load) is 9 MΩ. Current measurement (I) The current can only be measured at two inputs. The current to be measured is connected at one of the two input terminals for universal inputs (channel u8, u9) and a ground terminal. The current signal must be potential-free. The measuring ranges with or without offset 0 (4)...20 ma are selected via the software. The maximum input current must be limited to 50 ma; the internal resistance R i is < 50 Ω. Potentiometer measurement (Pot.) The potentiometer is connected between an input terminal for universal inputs (channel u8...u15), a ground terminal and the terminal U ref (reference voltage). To avoid overloading the reference output, the lowest potentiometer value should not drop below 1 kω. The reference output is not short circuitproof. The upper value of 2.5 kω is prescribed to guarantee a stable, fault-independent measurement. ) Note To maintain measuring accuracy, ground connections should always be connected to the same type of input. For an optimum connection, we recommend connecting one ground terminal of the I/O module directly with the AS or each appropriate cabinet terminal. Digital inputs (DI with UI) The AS also records binary information with the universal inputs. The information (alarm/status) is connected between an input terminal (u8...u15) and a ground terminal. The station applies a voltage of approximately 13 V to the terminal. If a contact is open, this usually corresponds to an INACTIVE state (bit = 0). If a contact is closed, there is an ACTIVE state (bit = 1) and 0 V is applied, giving a current of approximately 1 ma. Short-term changes of at least 20 ms between the station queries are saved briefly and processed at the next cycle. Every input can be defined individually as an alarm or a status through software parameter setting. With a local indicating unit (e.g. modu630 accessory) the digital inputs can be displayed. At the universal inputs, counter inputs of potential-free contacts, opto-couplers or transistors with an open collector can be connected. Technical specifications of the inputs and outputs Universal input Measuring range Resolution Accuracy of the measuring span plus measured value Ni/Pt1000-50 +150 C < 0.05 K ±0.5% 0.5% U (0/0.2...1 V) 0.02...1.1 V < 0.1 mv ±0.5% 0.5% U (0/2...10 V) 0.15...10.2 V < 1 mv ±0.5% 0.5% I (0/4...20 ma) 0.02...22 ma < 0.02 ma ±1% 2% R 200 2500 Ω < 0.1 Ω ±0.2% 1% Pot (> 1 kω) 1...100% < 0.5% ±1% 1% Binary input (0-I) Universal input (UI) Digital input (DI) Switching threshold active > 3 V > 4 V Switching threshold inactive < 1.5 V < 2.5 V Switching hysteresis > 0.4 V > 0.4 V Pulse counter 3 Hz 50 Hz Channel and terminal assignment modu530 Digital input Pulse counter (CI) Channel Schematic Terminals Signal GND 0 d0 1 1 d1 2 3 2 d2 4 5 3 d3 6 7 4 d4 8 9 5 d5 10 6 d6 11 13 7 d7 12 15 4/6 3.1 Right of amendment reserved 2015 Fr. Sauter AG

Product data sheet 92.031 modu530 Channel Schematic Terminals Universal input (Ni/Pt1000/U/I/R/Pot) Current signal only on channels 8, 9 or terminals 13, 14 8 u8 13 9 u9 14 10 u10 15 16 11 u11 17 18 12 u12 19 20 13 u13 21 14 u14 23 15 u15 24 Ref 22 Signal Reference voltage 1.23 V GND Connection of local operating unit The I/O module can be complemented with a modu630 local indicating unit (LOI) to allow digital inputs to be displayed directly. The function corresponds to the standard EN ISO 16484-2:2004 for local override and indicating units. The unit can be installed and removed during operation (hot-pluggable) without affecting functions of the AS or I/O module. modu630 contains 16 indicators in the form of bi-colour LEDs. It can be defined individually for each input whether it is used as an alarm or a status input. An alarm is generally indicated in red when the contact is open; a status is generally green when the contact is closed. Detailed information/functions of the LED actuation options can be seen in the data sheet PDS 92.081 for EY-LO 6**. If an incompatible operating unit is connected, this status is indicated by the flashing of all LEDs (red and yellow). There is no risk of the I/O module being destroyed. Disposal When disposing of the product, observe the currently applicable local laws. More information on materials can be found in the Declaration on materials and the environment for this product. Accessories EY-LO630F001 Single unit used for indication of the data points of the modu530 I/O or modu525 AS 16 LEDs LED indication, bi-colour, green/red (freely configurable for Event/Alarm) Right of amendment reserved 2015 Fr. Sauter AG 3.1 5/6

Connection diagram d0 d1 d2 d3 d4 d5 d6 d7 01 02 03 05 07 09 11 04 06 08 10 12 8 x DI Digital inputs 8 x UI Universal inputs Ref Reference signal 13 15 17 19 21 14 16 18 20 22 23 24 u8 u9 u10 u11 u12 u13 u14u15 0-20 ma (16, 18, 20) 0-10V 1...2,5 k Ref (22) A10508a Dimension drawing 42 115 M11416 85 170 85 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-controls.com 6/6 3.1 Right of amendment reserved 2015 Fr. Sauter AG