K-Line Mini - Contactors, Overload Relays and Accessories

Similar documents
IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

3 Pole Contactors with AC operating coils

TeSys IEC Contactors and Overload Relays

TeSys contactors From 115 to 2750 A

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

WEG Contactors - CWM and CWME Series

Motor protection relays

Mini Contactors & Overloads

7 - Control relays. Control relays. b k control relays

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

TeSys protection components

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

Square D General Purpose Relays

The technical guide TeSys D

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

RM4TA32 three-phase network control relay RM4-T - range V

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

Micro Contactor MA Series

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

RM4JA01F current measurement relay RM4-J - range ma V AC

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

Bulletin 817 Thermistor Protection Relay

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

TeSys contactors 5. Selection 5. For utilisation category AC-3. Operational current and power conforming to IEC (θ y 60 C) Contactor size

RM4JA32MW current measurement relay RM4-J - range A V AC DC

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

RM4TR31 three-phase network control relay RM4-T - range V

RM4JA31M current measurement relay RM4-J - range ma V AC

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

TeSys SK, K, D. Technical Data for Designers. Contents

Zelio Control-modular measurement and control relays 1

Electronic timer CT-ERS.21

Electronic timer CT-ARS.11

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

78 Series Electromechanical Relay Selection Guide

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

Electronic timer CT-ERD.12

Solid-state relay (SSR) advantages. Solid-state relays

RM4LA32M liquid level control relay RM4-L V AC

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM4UA33M voltage measurement relay RM4-U - range V V AC

K1D012ULH cam changeover switch - 2-pole A - screw mounting

RE9RA21MW7 off-delay timing relay s V AC -

3 - Interfaces. Contents 0. Interfaces for discrete signals. Selection guide... page 3/2. # Electromechanical interface modules...

Electronic timer CT-AHD.22

Contact protection relay

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

1492-SP Supplementary Protectors

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

K1B004TLH cam switch - 1 pole A - screw mounting

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Zelio Relay - plug-in relays

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Circuit Breakers Type CTI 25M, CTI 45MB

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

RW-E. Overloads. Solid-State Overload Relays. Standard Features

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

CS8 Industrial Control Relays

Model Number Structure

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

ABS2EC01EB input interface module mm - solid state - 24 V DC

Section 4 Ground-Fault Protection Devices

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Three-phase monitoring relay

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

UL 489 DIN Rail Miniature Circuit Breakers

RXM4AB3BD Miniature Plug-in relay - Zelio RXM 4 C/O 24 V DC 6 A with LED

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Protection Equipment

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1F006ALH cam switch - 6-pole A - screw mounting

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Transcription:

K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information............................................... 2-3 Mini-Contactors Characteristics................................................... 4-7 Selection....................................................... 8-19 Auxiliary Contacts and Timers..................................... 20-21 Accessories................................................... 22-23 Dimensions and Mounting........................................ 24-25 Schematics.................................................... 26-27 Overload Relays Characteristics................................................. 28-29 Selection.......................................................... 30 Dimensions, Mounting, and Schematics.................................. 31 Low Consumption Mini-Contactors Characteristics................................................. 32-35 Selection...................................................... 36-38 Auxiliary Contacts, Timers, and Accessories.............................. 39 Dimensions and Mounting........................................ 40-41 Schematics.................................................... 42-43 Definitions and Comments.......................................... 44

General Information Introduction The Telemecanique family of IEC style contactors and starters are the largest selling motor control devices in the world. When the application calls for world class products, select the Telemecanique IEC style contactors and starters for products that are marketed and sold in over 160 countries. Most devices are UL listed, CSA certified, CE marked, meet IEC 947 standards and are approved by most other international approved agencies. The Telemecanique family of IEC style contactors and starters include the following: K-Line mini-contactors and overload relays are for general purpose starting and protection in a small package for motor loads up to 12 Amps or resistive loads up to 20 Amps. D-Line contactors and overload relays offer the largest offering of accessories for maximum flexibility in customer applications and automated systems up to 150 motor full-load Amps or 200 Amp resistive loads. F-Line contactors and solid-state overload relays are for inductive loads up to 800 Amps or resistive loads up to 1350 Amps and share common accessories with the D-Line. GV manual starters provide manual isolation, manual motor control and overcurrent protection in one compact unit. They are approved for Group Motor Installations when used alone or with D-Line contactors. Integral self-protected starters combine all the functions of a disconnect switch, circuit breaker, contactor and overload relay in one coordinated unit to reduce required panel space by as much as 60% and reduce installation and wiring time. Selection of Telemecanique K-Line, D-Line and F-Line contactors are based on Utilization Categories, a combination of application and duty cycle rates defined by the following: The type of application (inductive motor loads or resistive loads) The conditions under which making or breaking current takes place (motor starting or running, reversing, plugging or jogging, locked rotor or stalled motor) Number of making and breaking operations (or cycles) required for the life of the contactor When specifying Telemecanique IEC contactors and starters refer to the following Square D documents: Catalog No. 8502CT9801 Catalog No. 8502CT9703 Catalog No. 8502CT9704 Catalog No. 8502CT9702 Catalog No. 2520CT9501 Catalog No. 8539CT9201 IEC Contactors Selection Guide K-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories F-Line Contactors, Overload Relays and Accessories GV2/GV3 Manual Starters and AK5 Panel Busbar System Integral Self-Protected Starters 2 1998 Square D All Rights Reserved 5/98

General Information The K-Line Mini-Contactors and Overload Relays are ideal for general duty applications where small size and reliability are key concerns. Three contactor ratings The K-Line mini-contactors are available in three ratings for the USA market. K06 rated for 3 hp motors at 480 VAC or 600 VAC K09 rated for 5 hp motors at 480 VAC or 600 VAC K12 rated for 7.5 hp motors at 480 VAC or 10 hp at 600 VAC Space savings The special magnet and armature structure allow for a DC coil-operated device with the same physical size and panel footprint of the AC coil version. IP20 rated finger-safe terminals with both North American and International terminal markings Mounts on 35mm DIN rail or panel mount with screws Available in 3-pole contactor versions with built-in auxiliary contact for holding circuit or 4-pole contactor versions Easily installed accessories 2-pole or 4-pole instantaneous auxiliary contact blocks with: or slip-on terminals, Transient voltage surge suppressors Electronic 1 to 30 second On-delay timers Three wiring methods to reduce installation time Captive screw terminals for use with either Phillips or slotted head screwdrivers, slip-on terminals for quick installation of single 1/4" or double 1/8" tabs, or terminal pins for soldering the contactor directly to a printed circuit board. Control circuit flexibility All versions of the K-Line mini-contactors are available with an AC, DC, or low consumption DC operating coil. The low consumption DC coil operating device can be energized by a low level DC signal from a computer or PLC and includes built-in transient suppression and LED On indicator. Bimetallic overload relays The K-Line Class 10 bimetallic overload relays are ambient-compensated and include single-phase sensitivity for phase unbalance and phase loss protection. Standard features include isolated N.C. trip contact and N.O. alarm contact, manual or automatic reset function, tamper resistant window for FLA settings and Test trip button. Five pins connect to the contactor load side terminals, three for the power circuit and two for the control circuit which eliminate customer wiring for the 3-wire control holding circuit. 5/98 1998 Square D All Rights Reserved 3

Characteristics Type LCkK and LPkK contactors Environment Rated insulation voltage (Ui) Conforming to IEC 947 V 690 Conforming to VDE 0110 gr C V 750 Conforming to BS 5424, NF C 20-040 V 690 Conforming to CSA 22-2 No. 14, UL 508 V 600 Rated impulse withstand voltage (Uimp) kv 8 Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 947, NF C 63-110, VDE 0660, BS 5424, UL508, CSA 22-2 No. 14 Approvals LCk-K06, LCk-K09, LCk-K12 LPk-K06, LPk-K09, LPk-K12 E164862 NLDX (Screw Clamp) E164862 NLDX2 (Slip-on & Solder Pin) Protective treatment Conforming to IEC 68 (DIN 50016) TC (Fungus-proof, tropicalization protection) Degree of protection Conforming to VDE 0106 Protection against direct finger contact Ambient air temperature around the device Storage Operation - 50 to + 80 C (-58 to +176 F) - 25 to + 50 C (-13 to +122 F) Maximum operating altitude Without derating 2000 m (6562 ft) Vertical axis 90 Horizontal axis 90 LR 43364 3211-04 90 Operating position 180 Flame resistance Shock resistance (1/2 sine wave, 11 ms) Vibration resistance 5 to 300 Hz Without derating Without derating Conforming to UL 94 Self-extinguishing material V1 Conforming to NF F 16-101 and 16-102 Conforming to requirement 2 Contactor open Contactor closed Contactor open Contactor closed 10 gn 15 gn 2 gn 4 gn Safe circuit separation Conforming to VDE 0106 and IEC 536 SELV a, up to 400 V Derate current carrying capability by 15% when not mounted vertically Cabling Min Max Max to IEC 947 Solid or stranded cable AWG 1 x 18 2 x 14 or 1 x 12 - Solid cable mm 2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5 Screw-clamp terminals Stranded cable without cable end mm 2 1 x 0.75 2 x 4 2 x 2.5 Stranded cable with cable end mm 2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5 Slip-on connectors Clip 2 x 2.8mm or 1 x 6.35mm (2 x 0.110 in. or 1 x 0.250 in.) Solder pins for printed circuit board Tightening torque Terminal referencing a Safety extra low voltage. 90 With locating device between power and control circuits 4 mm x 35 microns Phillips no. 2 or 3/16 slotted head screwdriver 0.8 N m (7lb.-in.) Conforming to standards EN 50005 and EN 50012 Up to 5 contacts 4 1998 Square D All Rights Reserved 5/98

Type LCkK and LPkK contactors Pole characteristics K-Line Mini-Contactors, Overload Relays and Accessories Characteristics Conventional thermal current (Ith) For ambient temperature 50 C ( 122 F) A 20 Rated operational frequency Hz 50/60 Frequency limits of the operational current Hz Up to 400 Rated operational voltage (Ue) V 690 Rated making capacity Rated breaking capacity Permissible short-time rating Short-circuit protection I rms conforming to NF C 63-110 and IEC 947 LCk-K06, LPIk-K06, LCk-K09, LPk-K09 110 LCk-K12, LPk-K12 A 144 LCk-K16 160 Conforming to NF C 63-110 and IEC 947 V 220/ 230 380/ 400 415 440 500 LCk-K06, LPk-K06, LCk-K09, LPk-K09 I rms 110 110 110 110 80 70 LCk-K12, LPk-K12 A 110 80 70 LCk-K16 110 80 70 In free air for a time "t from cold state (θ 50 C) 1 s 5 s 10 s 30 s 1 min 3 min 15 min LCk-K06, LPk-K06, LCk-K09, LPk-K09 A 90 85 80 60 45 40 20 LCk-K12, LPk-K12 LCk-K16 115 105 100 75 55 50 25 By circuit breaker By fuses Average impedance per pole At Ith and 50 Hz mω 3 Utilization in category AC-1 resistive circuit, heating, lighting (Ue 440 V) Utilization in category AC-3 Squirrel cage motors Utilization in category AC-3 Squirrel cage motors Maximum rated operational current for a temperature 50 C Maximum rated operational current for a temperature 70 C Rated operational current limits in relation to on-load factor and operating frequency Increase in operational current by paralleling of poles A 20 A A 660/ 690 Select in accordance with NEC and local codes Max 400% of motor FLA 16 for Ue only On-load factor 90% 60% 30% 300 op. cycles/hour 13 15 18 120 op. cycles/hour 15 18 19 30 op. cycles/hour 19 20 20 Apply the following coefficients to the current values given above. These take into account the often unbalanced current distribution between poles 2 poles in parallel: K = 1.60 3 poles in parallel: K = 2.25 4 poles in parallel: K = 2.80 Operational power Voltage 115 220 V according to the voltage 50 or 60 Hz 1-ph 1-ph 3-ph 3-ph 3-ph 3-ph 3-ph LCk-K06, LPk-K06 Motor ratings kw 0.37 0.75 1.5 2.2 3 3 3 LCk-K09, LPk-K09 Motor ratings kw 0.55 1.1 2.2 4 4 4 4 220/ 240 LCk-K12, LPk-K12 Motor ratings kw 3 5.5 LCk-K16 Motor ratings kw 4 7.5 Maximum operating rate (in operating cycles/ hour in relation to % of rated power) 380/ 415 440/ 480 5.5/4 (480) 5.5/4 (480) 500/ 600 4 4 4 4 660/ 690 Op. cycles/hour 600 900 1200 Power 100% 75% 50% 220/ 208 220/ 240 460/ 480 575/ 600 Operational power Voltage 115 220 V according to the voltage 50 or 60 Hz 1-ph 1-ph 3-ph 3-ph 3-ph 3-ph LCk-K06, LPk-K06 Motor ratings hp 0.5 1 1.5 3 3 3 LCk-K09, LPk-K09 Motor ratings hp 0.5 1.5 2 3 5 5 LCk-K12, LPk-K12 Motor ratings hp 1 2 3 3 7.5 10 LCk-K16, LPk-K12 Not for North American Applications. Not UL Listed or CSA Certified. 5/98 1998 Square D All Rights Reserved 5

Characteristics Type LCkK and LPkK contactors Control circuit characteristics Type LC1 LC2 LC7 LC8 LP1 LP2 Rated control circuit voltage (Uc) V AC 12 to 690 c AC 24 to 230 DC 12 to 250 c Control voltage limits ( 50 C) single voltage coil For operation a 0.8 to 1.15 Uc 0.85 to 1.1 Uc 0.8 to 1.15 Uc For drop-out 0.20 Uc 0.10 Uc 0.10 Uc Average consumption Inrush 30 VA 3 VA 3 W at 20 C and at Uc Sealed 4.5 VA 3 VA 3 W Heat dissipation W 1.3 3 3 Operating time at 20 C and at Uc Between coil energization and: - opening of the N.C. contacts ms 5 to 15 25 to 35 25 to 35 - closing of the N.O. contacts ms 10 to 20 30 to 40 30 to 40 Between coil de-energization and: - opening of the N.O. contacts ms 10 to 20 30 10 - closing of the N.C. contacts ms 15 to 25 40 15 Maximum immunity to microbreaks ms 2 2 2 Maximum operating rate In operating cycles per hour 3600 3600 3600 Mechanical durability at Uc In millions of operating cycles 50/60 Hz coil 10 5 10 5 DC coil 10 5 c For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC (50 to 129 V) or LAF-KE1UG (130 to 250 V), see page 22. a LC1-K16: 0.85 to 1.15 Uc. 6 1998 Square D All Rights Reserved 5/98

Types LCkK and LPkK contactors K-Line Mini-Contactors, Overload Relays and Accessories Characteristics Auxiliary contact characteristics of contactors and instantaneous contact blocks On LCk-K or LPk-K 1 Number of contacts On L-K 2 or 4 Rated operational voltage (Ue) Up to V 690 Conforming to BS 5424 V 690 Conforming to IEC 947 V 690 Rated insulation voltage (Ui) Conforming to VDE 0110 group C V 750 Conforming to CSA C 22.2 No.14, UL 508 V 600 Conventional thermal current (lth) For ambient temperature 50 C A 10 Frequency of operational current Hz Up to 400 U min (DIN 19 240) V 17 Minimum switching capacity I min ma 5 Short-circuit protection Conforming to IEC 947 and VDE 0660, gl fuse A 10 Rated making capacity Conforming to IEC 947 I rms A 110 1 s A 80 Overload current Permissible for 500 ms A 90 100 ms A 110 Insulation resistance MΩ > 10 Non-overlap distance Linked contacts conforming to INRS and BIA spec. mm 0.5 Operational power of contacts conforming to IEC 947 AC supply, category AC-15 DC supply, category DC-13 Electrical durability (valid up to 3600 operating cycles per hour) on an inductive load such as the coil of an electromagnet: making current (power factor 0.7) = 10 times the breaking current (power factor 0.4). V 24 48 110/ 127 220/ 230 440 600/ 690 Electrical durability (valid up to 1200 operating cycles per hour, on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. V 24 48 110 220 440 600 1 million operating cycles VA 48 96 240 440 880 1200 W 120 80 60 52 51 50 2 million operating cycles VA 17 34 86 158 317 500 W 55 38 30 28 26 25 10 million operating cycles VA 7 14 36 66 132 200 W 15 11 9 8 7 6 Occasional making capacity VA 1000 2050 5000 10000 13000 9000 W 720 600 400 300 230 200 Power in broken VA Power in broken W 1 Breaking limit of contacts valid for: - maximum of 50 operating cycles at 10 s intervals (breaking current = making current x power factor 0.7). 2 Electrical durability of contacts for: - 1 million operating cycles (2a) - 3 million operating cycles (2b) -10 million operating cycles (2c). 3 Breaking limit of contacts valid for: - maximum of 20 operating cycles at 10 s intervals with current passing for 0.5 s per operating cycle. 4 Thermal limit. 16 000 10 000 8000 6000 5000 4000 3000 2000 1000 800 600 500 400 300 200 100 80 60 40 1 4 2a 2b 2c 24 48 110 220 120 380 500 440 690 V 1000 700 500 300 250 200 Time constant in ms 200 140 100 50 20 100 80 60 50 40 30 20 10 8 6 4 3 2a 2b 2c 12 24 48 110 220 440 600 V 5/98 1998 Square D All Rights Reserved 7

Selection - Contactors for Motor Control Control circuit: AC Kilowatt ratings for International applications LC1-KO610kk LC1-KO6107kk LC7-KO6105kk General purpose contactors c - Mounting on 35 mm " DIN rail or 4mm (#6) screws. - Screws in open ready-to-tighten position. Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 220 V 230 V 380 V 415 V 440/500 V 660/690 V Rated operational current in AC-3 440V up to Type of connection Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage catalog number a q kw kw kw A N.O. N.C. kg (lb.) 1.5 2.2 3 6 2.2 4 4 9 3 5.5 3 7.5 4 (> 440) 5.5 (440) 4 (440) 5.5 (440) Contactors for use in sensitive environments c 12 16 Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with built-in rectifier and suppressor. - Mounting on 35 mm " DIN rail or 4 mm (#6) screws - Screws in the open ready-to-tighten position. 1.5 2.2 3 6 2.2 4 4 9 3 5.5 4 (> 440) 5.5 (440) 12 Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Weight 1 LC1-K0610kk 0.180 (0.40) 1 LC1-K0601kk 0.180 (0.40) 1 LC1-K06107kk 0.180 (0.40) 1 LC1-K06017kk 0.180 (0.40) 1 LC1-K06105kk 0.210 (0.46) 1 LC1-K06015kk 0.210 (0.46) 1 LC1-K0910kk 0.180 (0.40) 1 LC1-K0901kk 0.180 (0.40) 1 LC1-K09107kk 0.180 (0.40) 1 LC1-K09017kk 0.180 (0.40) 1 LC1-K09105kk 0.210 (0.46) 1 LC1-K09015kk 0.210 (0.46) 1 LC1-K1210kk 0.180 (0.40) 1 LC1-K1201kk 0.180 (0.40) 1 LC1-K12107kk 0.180 (0.40) 1 LC1-K12017kk 0.180 (0.40) 1 LC1-K12105kk 0.210 (0.46) 1 LC1-K12015kk 0.210 (0.46) 1 LC1-K1610kk f 0.180 (0.40) 1 LC1-K1601kk f 0.180 (0.40) 1 LC1-K16107kk f 0.180 (0.40) 1 LC1-K16017kk f 0.180 (0.40) 1 LC1-K16105kk f 0.210 (0.46) 1 LC1-K16015kk f 0.210 (0.46) 1 LC7-K0610kk 0.225 (0.50) 1 LC7-K0601kk 0.225 (0.50) 1 LC7-K06107kk 0.225 (0.50) 1 LC7-K06017kk 0.225 (0.50) 1 LC7-K06105kk 0.255 (0.56) 1 LC7-K06015kk 0.255 (0.56) 1 LC7-K0910kk 0.225 (0.50) 1 LC7-K0901kk 0.225 (0.50) 1 LC7-K09107kk 0.225 (0.50) 1 LC7-K09017kk 0.255 (0.56) 1 LC7-K09105kk 0.255 (0.56) 1 LC7-K09015kk 0.225 (0.50) 1 LC7-K1210kk 0.225 (0.50) 1 LC7-K1201kk 0.225 (0.50) 1 LC7-K12107kk 0.225 (0.50) 1 LC7-K12017kk 0.225 (0.50) Solder pins for printed circuit 1 LC7-K12105kk 0.255 (0.56) board 1 LC7-K12015kk 0.255 (0.56) c Add-on auxiliary contact blocks and accessories, see page 20. a Standard control circuit voltages, see page 10. q For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC (50 to 129 V) or LA4-KE1UG (130 to 250 V), see page 22. f For International applications only - not UL Listed or CSA Certified. 8 1998 Square D All Rights Reserved 5/98

Selection - Contactors for Motor Control Control circuit: AC Horsepower ratings for North American applications General purpose contactors c - Mounting on 35 mm " DIN rail or 4mm (#6) screws. - Screws in open ready-to-tighten position. Maximum Horsepower Rating 1 - Phase 50/60 Hz 115/ 120 V 230/ 240 V 3 - Phase 50/60 Hz 200/ 208 V 220/ 240 V 460/ 480 V 575/ 600 V Maximum inductive current in AC-3 category Type of Connection Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a q Weight LC1-KO610kk LC1-KO6107kk hp hp hp hp hp hp A N.O. N.C. kg (lb.) 0.5 1 1.5 1.5 3 3 6 0.5 1.5 2 3 5 5 9 1 2 3 3 7.5 10 12 Not for North American applications Not UL Listed or CSA Certified Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board 1 LC1-K0610kk 0.180 (0.40) 1 LC1-K0601kk 0.180 (0.40) 1 LC1-K06107kk 0.180 (0.40) 1 LC1-K06017kk 0.180 (0.40) 1 LC1-K06105kk 0.210 (0.46) 1 LC1-K06015kk 0.210 (0.46) 1 LC1-K0910kk 0.180 (0.40) 1 LC1-K0901kk 0.180 (0.40) 1 LC1-K09107kk 0.180 (0.40) 1 LC1-K09017kk 0.180 (0.40) 1 LC1-K09105kk 0.210 (0.46) 1 LC1-K09015kk 0.210 (0.46) 1 LC1-K1210kk 0.180 (0.40) 1 LC1-K1201kk 0.180 (0.40) 1 LC1-K12107kk 0.180 (0.40) 1 LC1-K12017kk 0.180 (0.40) 1 LC1-K12105kk 0.210 (0.46) 1 LC1-K12015kk 0.210 (0.46) 1 LC1-K1610kk f 0.180 (0.40) 1 LC1-K1601kk f 0.180 (0.40) 1 LC1-K16107kk f 0.180 (0.40) 1 LC1-K16017kk f 0.180 (0.40) 1 LC1-K16105kk f 0.210 (0.46) 1 LC1-K16015kk f 0.210 (0.46) LC7-KO6105kk Contactors for use in sensitive environments c Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with built-in rectifier and suppressor. - Mounting on 35 mm " DIN rail or 4mm (#6) screws - Screws in the open ready-to-tighten position. 0.5 1 1.5 3 3 6 6 1 LC7-K0610kk 0.225 (0.50) 1 LC7-K0601kk 0.225 (0.50) Slip-on 1 x 0.25 in., 1 LC7-K06107kk 0.225 (0.50) 1 LC7-K06017kk 0.225 (0.50) Solder pins for printed circuit 1 LC7-K06105kk 0.255 (0.56) board 1 LC7-K06015kk 0.255 (0.56) 0.5 1.5 2 3 5 5 9 1 LC7-K0910kk 0.225 (0.50) 1 LC7-K0901kk 0.225 (0.50) Slip-on 1 x 0.25 in., 1 LC7-K09107kk 0.225 (0.50) 1 LC7-K09017kk 0.255 (0.56) Solder pins for printed circuit 1 LC7-K09105kk 0.255 (0.56) board 1 LC7-K09015kk 0.225 (0.50) 1 2 3 3 7.5 10 12 1 LC7-K1210kk 0.225 (0.50) 1 LC7-K12101kk 0.225 (0.50) Slip-on 1 x 0.25 in., 1 LC7-K12107kk 0.225 (0.50) 1 LC7-K121017kk 0.225 (0.50) Solder pins for printed circuit 1 LC7-K12005kk 0.255 (0.56) board 1 LC7-K12015kk 0.255 (0.56) c Add-on auxiliary contact blocks and accessories, see page 20. a Standard control circuit voltages (variable delivery times, please consult your Regional Sales Office). q For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC (50 to 129 V) or LA4-KE1UG (130 to 250 V), see page 22. f For International applications only - not UL Listed or CSA Certified. 5/98 1998 Square D All Rights Reserved 9

Selection - Contactors for Motor Control Control circuit: DC Kilowatt ratings for International applications 3-pole contactors c - Mounting on 35 mm " DIN rail or 4 mm (#6) screws. - Screws in open ready-to-tighten position. Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 220 V 230 V 380 V 415 V 440/500 V 660/690 V Rated operational current in AC-3 440 V up to Type of connection Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a q Weight LP1-K0610kk LP1-K06107kk kw kw kw A N.O. N.C. kg (lb.) 1.5 2.2 3 6 2.2 4 4 9 3 5.5 4 (>440 V) 5.5 (440 V) 12 Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., 1 LP1-K0610kk 0.225 (0.50) 1 LP1-K0601kk 0.225 (0.50) 1 LP1-K06107kk 0.225 (0.50) 1 LP1-K06017kk 0.225 (0.50) 1 LP1-K06105kk 0.225 (0.56) 1 LP1-K06015kk 0.225 (0.56) 1 LP1-K0910kk 0.225 (0.50) 1 LP1-K0901kk 0.225 (0.50) 1 LP1-K09107kk 0.225 (0.50) 1 LP1-K09017kk 0.225 (0.50) 1 LP1-K09105kk 0.255 (0.56) 1 LP1-K09015kk 0.255 (0.56) 1 LP1-K1210kk 0.225 (0.50) 1 LP1-K1201kk 0.225 (0.50) 1 LP1-K12107kk 0.225 (0.50) 1 LP1-K12017kk 0.225 (0.50) 1 LP1-K12105kk 0.255 (0.56) Solder pins for printed circuit board 1 LP1-K12015kk 0.255 (0.56) c Add on auxiliary contact blocks and accessories, see pages 20. a Standard control circuit voltages (variable delivery times, please consult your Regional Sales Office) Coil Selection Contactor LC1-K (0.8 to 1.15 Uc) (0.85 to 1.1 Uc) Volts AC 50/60 Hz 12 20 24 q 36 42 48 110 127 200/ 208 220/ 230 230 230/ 240 256 277 Code J7 Z7 B7 C7 D7 E7 F7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts AC 50/60 Hz 400/ 415 480 T7 500 575 600 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72 660/ 690 380/ 400 400 Contactor LC7-K (0.85 to 1.1 Uc) Volts AC 50/60 Hz 24 42 48 110 220 230/ 240 Code B7 D7 E7 F7 M7 U7 Contactor LP1-K (0.8 to 1.15 Uc) Volts DC 12 20 24 q 36 48 60 72 100 110 125 155 174 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3 q When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil (AC control circuit voltage code Z7, DC control circuit voltage code ZD) so as to compensate for the incurred voltage drop. 10 1998 Square D All Rights Reserved 5/98

Selection - Contactors for Motor Control Control circuit: DC Horsepower ratings for North American applications 3-pole contactors c - Mounting on 35 mm " DIN rail or 4mm (#6) screws. - Screws in open ready-to-tighten position. Maximum Horsepower ratings 1- phase 50/60 HZ 115/ 120 V 230/ 240 V 3- phase 50/60 HZ 200/ 208 V 220/ 240 V 460/ 480 V 575/ 600 V Maximum inductive current in AC-3 category Type of connection Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a q Weight LP1-K0610kk LP1-K06107kk hp hp hp hp hp hp A N.O. N.C. kg (lb.) 0.5 1 1.5 1.5 3 3 6 0.5 1.5 2 3 5 5 9 1 2 3 3 7.5 10 12 Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., 1 LP1-K0610kk 0.225 (0.50) 1 LP1-K0601kk 0.225 (0.50) 1 LP1-K06107kk 0.225 (0.50) 1 LP1-K06017kk 0.225 (0.50) 1 LP1-K06105kk 0.255 (0.56) 1 LP1-K06015kk 0.255 (0.56) 1 LP1-K0910kk 0.225 (0.50) 1 LP1-K0901kk 0.225 (0.50) 1 LP1-K09107kk 0.225 (0.50) 1 LP1-K09017kk 0.225 (0.50) 1 LP1-K09105kk 0.255 (0.56) 1 LP1-K09015kk 0.255 (0.56) 1 LP1-K1210kk 0.225 (0.50) 1 LP1-K1201kk 0.225 (0.50) 1 LP1-K12107kk 0.225 (0.50) 1 LP1-K12017kk 0.225 (0.50) Solder pins for printed circuit 1 LP1-K12105kk 0.255 (0.56) board 1 LP1-K12015kk 0.255 (0.56) c Add on auxiliary contact blocks and accessories, see page 20. astandard control circuit voltages (variable delivery times, please consult your Regional Sales Office) Coil Selection Contactor LC1-K (0.8 to 1.15 Uc) (0.85 to 1.1 Uc) Volts AC 50/60 Hz 12 20 24 q 36 42 48 110 127 200/ 208 220/ 230 230 230/ 240 256 277 Code J7 Z7 B7 C7 D7 E7 F7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts AC 50/60 Hz 400/ 415 480 T7 500 575 600 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72 660/ 690 380/ 400 400 Contactor LC7-K (0.85 to 1.1 Uc) Volts AC 50/60 Hz 24 42 48 110 220 230/ 240 Code B7 D7 E7 F7 M7 U7 Contactor LP1-K (0.8 to 1.15 Uc) Volts DC 12 20 24 q 36 48 60 72 100 110 125 155 174 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3 q When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil (AC control circuit voltage code Z7, DC control circuit voltage code ZD) so as to compensate for the incurred voltage drop. 5/98 1998 Square D All Rights Reserved 11

Selection - Contactors for Resistive Loads Control circuit: AC 3- and 4-pole contactors c - Mounting on 35 mm " DIN rail or by 4mm (#6) screws. - Screws in open ready-to-tighten position. Non inductive loads Category AC-1 Maximum current at 50 C Type of connection Power poles Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a q Weight LC1-K09004kk A N.O. N.C. N.O. N.C. kg (lb.) 3 1 LC1-K0910kk 0.255 (0.50) 3 1 LC1-K0901kk 0.255 (0.50) 4 LC1-K09004kk 0.180 (0.40) 2 2 LC1-K09008kk 0.180 (0.40) 3 1 LC1-K09107kk 0.255 (0.50) 20 Slip-on 1 x 0.25 in. 3 1 LC1-K09017kk 0.255 (0.50) 4 LC1-K090047kk 0.180 (0.40) 2 2 LC1-K090087kk 0.180 (0.40) 3 1 LC1-K09105kk 0.255 (0.56) Solder pins for printed circuit board 3 1 LC1-K09015kk 0.255 (0.56) 4 LC1-K090045kk 0.210 (0.46) 2 2 LC1-K090085kk 0.210 (0.46) LC1-K090047kk Contactors for use in sensitive environments c Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with built-in rectifier suppressor fitted standard. - Mounting on 35 mm " DIN rail or 4mm (#6) screws - Screws in open ready-to-tighten position. 20 Slip-on 1 x 0.25 in. 3 1 LC7-K0910kk 0.255 (0.50) 3 1 LC7-K0901kk 0.255 (0.50) 4 LC7-K09004kk 0.255 (0.50) 2 2 LC7-K09008kk 0.255 (0.50) 3 1 LC7-K09107kk 0.255 (0.50) 3 LC7-K09017kk 0.255 (0.50) 4 1 LC7-K090047kk 0.255 (0.50) 2 2 LC7-K090087kk 0.255 (0.50) 3 1 LC7-K09105kk 0.255 (0.56) 3 LC7-K09015kk 0.255 (0.56) Solder pins for printed circuit board 4 1 LC7-K090045kk 0.255 (0.56) 2 LC7-K090085kk 0.255 (0.56) c Add-on auxiliary contact blocks and accessories, see page 20. a Standard control circuit voltages, see page 13. q For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC (50 to 129 V) or LAF-KE1UG (130 to 250 V), see page 22. 12 1998 Square D All Rights Reserved 5/98

Selection - Contactors for Resistive Loads Control circuit: DC 3- and 4-pole contactors c - Mounting on 35 mm " DIN rail or 4mm (#6) screws. - Screws in open ready-to-tighten position. Non-inductive loads Category AC-1 Maximum current at 50 C Type of connection Power poles Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a Weight LC7-K090047kk A N.O. N.C. N.O. N.C. kg (lb.) 20 Slip-on 1 x 0.25 in. 3 1 LP1-K0910kk 0.225 (0.50) 3 1 LP1-K0901kk 0.225 (0.50) 4 LP1-K09004kk 0.225 (0.50) 2 2 LP1-K09008kk 0.225 (0.50) 3 1 LP1-K09107kk 0.225 (0.50) 3 1 LP1-K09017kk 0.225 (0.50) 4 LP1-K090047kk 0.225 (0.50) 2 2 LP1-K090087kk 0.225 (0.50) 3 1 LP1-K09105kk 0.255 (0.56) 3 1 LP1-K09015kk 0.255 (0.56) Solder pins 4 LP1-K090045kk 0.255 (0.56) 2 2 LP1-K090085kk 0.255 (0.56) c Add-on auxiliary contact blocks and accessories, see page 20. a Standard control circuit voltages (variable delivery times, please consult your Regional Sales Office). Coil Selection Contactor LC1-K (0.8 to 1.15 Uc) (0.85 to 1.1 Uc) Volts AC 50/60 Hz 12 20 24 q 36 42 48 110 127 200/ 208 220/ 230 230 230/ 240 256 277 Code J7 Z7 B7 C7 D7 E7 F7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts AC 50/60 Hz 400/ 415 480 T7 500 575 600 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72 660/ 690 380/ 400 400 Contactor LC7-K (0.85 to 1.1 Uc) Volts AC 50/60 Hz 24 42 48 110 220 230/ 240 Code B7 D7 E7 F7 M7 U7 Contactor LP1-K (0.8 to 1.15 Uc) Volts DC 12 20 24 q 36 48 60 72 100 110 125 155 174 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3 q When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil (AC control circuit voltage code Z7, DC control circuit voltage code ZD) so as to compensate for the incurred voltage drop. 5/98 1998 Square D All Rights Reserved 13

Selection - Reversing Contactors for Motor Control Control circuit: AC Kilowatt ratings for International applications LC2-K0610kk LC2-K06107kk LC8-K06105kk 3-pole reversing contactors c - Integrated mechanical interlock. Customer wiring required to connect coil terminations to electrical interlock. See page 27. - Pre-wired power circuit connections standard on screw clamp versions. - Mounting on 35 mm " DIN rail or 4mm (#6) screws - Screws in open ready-to-tighten position. Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 220 V 230 V 380 V 415 V 440/500 V 660/690 V Rated operational current in AC-3 up to 400 V Connection Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a q kw kw kw A N.O. N.C. kg (lb.) 1.5 2.2 3 6 2.2 4 4 9 3 5.5 3 7.5 4 (> 440) 5.5 (440) 4 (> 440) 5.5 (440) 12 16 Slip-on 1 x 0.25 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. Solder pins for printed circuit board Reversing contactors for use in sensitive environments c Weight 1 LC2-K0610kk 0.390 (0.86) 1 LC2-K0601kk 0.390 (0.86) 1 LC2-K06107kk 0.370 (0.81) 1 LC2-K06017kk 0.370 (0.81) 1 LC2-K06105kk 0.430 (0.95) 1 LC2-K06015kk 0.430 (0.95) 1 LC2-K0910kk 0.390 (0.86) 1 LC2-K0901kk 0.390 (0.86) 1 LC2-K09107kk 0.370 (0.81) 1 LC2-K09017kk 0.370 (0.81) 1 LC2-K09105kk 0.430 (0.95) 1 LC2-K09015kk 0.430 (0.95) 1 LC2-K1210kk 0.390 (0.86) 1 LC2-K1201kk 0.390 (0.86) 1 LC2-K12107kk 0.370 (0.81) 1 LC2-K12017kk 0.370 (0.81) 1 LC2-K12105kk 0.430 (0.95) 1 LC2-K12015kk 0.430 (0.95) 1 LC2-K1610kk f 0.390 (0.86) 1 LC2-K1601kk f 0.390 (0.86) 1 LC2-K16107kk f 0.370 (0.81) 1 LC2-K16017kk f 0.370 (0.81) 1 LC2-K16105kk f 0.430 (0.95) 1 LC2-K16015kk f 0.430 (0.95) Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. - Integral mechanical interlock. Customer wiring required to connect coil terminations to electrical interlock. See page 27. - Pre-wired power circuit connections standard on screw clamp versions. - Mounting on 35 mm " DIN rail or 4mm (#6) screws. - Screws in open, ready-to-tighten position. 1 LC8-K0610kk 0.480 (1.05) 1 LC8-K0601kk 0.480 (1.05) 1.5 2.2 3 6 Slip-on 1 x 0.25 in. 1 LC8-K06107kk 0.460 (1.00) 1 LC8-K06017kk 0.460 (1.00) Solder pins for printed circuit board LC8-K06105kk 0.520 (1.14) 1 LC8-K06015kk 0.520 (1.14) 1 LC8-K0910kk 0.480 (1.05) 1 LC8-K0901kk 0.480 (1.05) 2.2 4 4 9 Slip-on 1 x 0.25 in. 1 LC8-K09107kk 0.460 (1.00) 1 LC8-K09017kk 0.460 (1.00) Solder pins for printed circuit board 1 LC8-K09105kk 0.520 (1.14) LC8-K09015kk 0.520 (1.14) 1 LC8-K1210kk 0.480 (1.05) 1 LC8-K1201kk 0.480 (1.05) 3 5.5 4 (> 440) 1 LC8-K12107kk 0.460 (1.00) 12 Slip-on 1 x 0.25 in. 5.5 (440) 1 LC8-K12017kk 0.460 (1.00) Solder pins for printed circuit board 1 LC8-K12105kk 0.520 (1.14) 1 LC8-K12015kk 0.520 (1.14) c Auxiliary contact blocks and accessories, see page 20. a Control circuit voltage codes, see page 16. q For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC (50 to 129 V) or LA4-KE1UG (130 to 250 V), see page 22. f For International applications only - not UL Listed or CSA Certified. 14 1998 Square D All Rights Reserved 5/98

Selection - Reversing Contactors for Motor Control Control circuit: AC Horsepower ratings for North American applications LC2-K0610kk LC2-K06107kk LC8-K06105kk 3-pole reversing contactors c Customer wiring required to connect coil terminations to electrical interlock. See page 27. - Pre-wired power circuit connections standard on screw clamp versions. - Mounting on 35 mm " DIN rail or 4mm (#6) screws. - Screws in open ready-to-tighten position. Maximum Horsepower ratings 1- phase 50/60 HZ 115/ 120 V 230/ 240 V 3 - phase50/60 HZ 200/ 208 V 220/ 240 V 460/ 480 V 575/ 600 V Maximum Inductive current in AC-3 category Type of connection Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a q hp hp hp hp hp hp A N.O. N.C. kg (lb.) 0.5 1 1.5 1.5 3 3 6 0.5 1.5 2 3 5 5 9 1 2 3 3 7.5 10 12 Not for North American applications Not UL Listed or CSA Certified Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Reversing contactors for use in sensitive environments c Weight 1 LC2-K0610kk 0.390 (0.86) 1 LC2-K0601kk 0.390 (0.86) 1 LC2-K06107kk 0.370 (0.81) 1 LC2-K06017kk 0.370 (0.81) 1 LC2-K06105kk 0.430 (0.95) 1 LC2-K06015kk 0.430 (0.95) 1 LC2-K0910kk 0.390 (0.86) 1 LC2-K0901kk 0.390 (0.86) 1 LC2-K09107kk 0.370 (0.81) 1 LC2-K09017kk 0.370 (0.81) 1 LC2-K09105kk 0.430 (0.95) 1 LC2-K09015kk 0.430 (0.95) 1 LC2-K1210kk 0.390 (0.86) 1 LC2-K1201kk 0.390 (0.86) 1 LC2-K12107kk 0.370 (0.81) 1 LC2-K12017kk 0.370 (0.81) 1 LC2-K12105kk 0.430 (0.95) 1 LC2-K12015kk 0.430 (0.95) 1 LC2-K1610kk f 0.390 (0.86) 1 LC2-K1601kk f 0.390 (0.86) 1 LC2-K16107kk f 0.370 (0.81) 1 LC2-K16017kk f 0.370 (0.81) 1 LC2-K16105kk f 0.430 (0.95) 1 LC2-K16015kk f 0.430 (0.95) Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor included as standard. - Integrated mechanical interlock. Customer wiring required to connect coil terminations to electrical interlock. See page 27. - Pre-wired power circuit connections standard on screw clamp versions. - Mounting on 35 mm " DIN rail or 4mm (#6) screws. - Screws in open, ready-to-tighten position. 1 LC8-K0610kk 0.480 (1.05) 1 LC8-K0601kk 0.480 (1.05) 0.5 1 1.5 1.5 3 3 6 Slip-on 1 x 0.25 in. 1 LC8-K06107kk 0.460 (1.00) 1 LC8-K06017kk 0.460 (1.00) Solder pins for printed 1 LC8-K06105kk 0.520 (1.14) circuit board 1 LC8-K06015kk 0.520 (1.14) 1 LC8-K0910kk 0.480 (1.05) 1 LC8-K0901kk 0.480 (1.05) 0.5 1.5 2 3 5 5 9 Slip-on 1 x 0.25 in. 1 LC8-K09107kk 0.460 (1.00) 1 LC8-K09017kk 0.460 (1.00) Solder pins for printed 1 LC8-K09105kk 0.520 (1.14) circuit board 1 LC8-K09015kk 0.520 (1.14) 1 LC8-K1210kk 0.480 (1.05) 1 LC8-K1201kk 0.480 (1.05) 1 2 3 3 7.5 10 12 Slip-on 1 x 0.25 in. 1 LC8-K12107kk 0.460 (1.00) 1 LC8-K12017kk 0.460 (1.00) Solder pins for printed 1 LC8-K12105kk 0.520 (1.14) circuit board 1 LC8-K12015kk 0.520 (1.14) c Auxiliary contact blocks and accessories, see page 20. a Control circuit voltage codes, see page 17. q For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC (50 to 129 V) or LA4-KE1UG (130 to 250 V), see page 22. f For International applications only - not UL Listed or CSA Certified. 5/98 1998 Square D All Rights Reserved 15

Selection - Reversing Contactors for Motor Control Control circuit: DC Kilowatt ratings for International applications LP2-K0610kk LP2-K06107kk 3-pole reversing contactors c - Integrated mechanical interlock. Customer wiring required to connect coil terminations to electrical interlock. See page 27. - Pre-wired power circuit connections standard on screw clamp versions. - Mounting on 35 mm " DIN rail or 4mm (#6) screws - Screws in open ready-to-tighten position. Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 220 V 230 V 380 V 415 V 440/500 V 660/690 V Rated operational current in AC-3 up to 400 V Type of connection Auxiliary contacts Basic catalog number. complete with code indicating control circuit voltagea kw kw kw A N.O. N.C. kg (lb.) 1.5 2.2 3 6 2.2 4 4 9 3 5.5 4 (> 440) 5.5 (440) 12 Slip-on 1 x 0.25 in. Solder pins for printed circuit board Screwclamp Slip-on 1 x 0.25 in. Solder pins for printed circuit board Screwclamp Slip-on 1 x 0.25 in. Weight 1 LP2-K0610kk 0.480 (1.05) 1 LP2-K0601kk 0.480 (1.05) 1 LP2-K06107kk 0.460 (1.00) LP2-K06017kk 0.460 (1.00) 1 LP2-K06105kk 0.520 (1.14) 1 LP2-K06015kk 0.520 (1.14) 1 LP2-K0910kk 0.480 (1.05) 1 LP2-K0901kk 0.480 (1.05) 1 LP2-K09107kk 0.460 (1.00) 1 LP2-K09017kk 0.460 (1.00) 1 LP2-K09105kk 0.520 (1.14) 1 LP2-K09015kk 0.520 (1.14) 1 LP2-K1210kk 0.480 (1.05) 1 LP2-K1201kk 0.480 (1.05) 1 LP2-K12107kk 0.460 (1.00) 1 LP2-K12017kk 0.460 (1.00) 1 LP2-K12105kk 0.520 (1.14) Solder pins for printed circuit board 1 LP2-K12015kk 0.520 (1.14) c Auxiliary contact blocks and accessories, see page 20. a Standard control circuit voltages (variable delivery times, please consult you Regional Sales Office). Coil Selection Reversing contactors LC2-K (0.8 to 1.15 Uc) (0.85 to 1.1 Uc) Volts AC 50/60 Hz 12 20 24 q 36 42 48 110 127 200/ 208 220/ 230 230 230/ 240 256 277 Code J7 Z7 B7 C7 D7 E7 F7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts AC 50/60 Hz 400/ 415 480 T7 500 575 600 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72 660/ 690 380/ 400 400 Reversing contactors LC8-K (0.85 to 1.1 Uc) Volts AC 50/60 Hz 24 42 48 110 220 230/ 240 Code B7 D7 E7 F7 M7 U7 Reversing contactors LP2-K (0.8 to 1.15 Uc) Volts DC 12 20 24 q 36 48 60 72 100 110 125 155 174 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3 q When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil (AC control circuit voltage code Z7, DC control circuit voltage code ZD) so as to compensate for the incurred voltage drop. 16 1998 Square D All Rights Reserved 5/98

Selection - Reversing Contactors for Motor Control Control circuit: DC Horsepower ratings for North American applications LP2-K0610kk LP2-K06107kk 3-pole reversing contactors c - Integrated mechanical interlock. Customer wiring required to connect coil terminations to electrical interlock. See page 27. - Pre-wired power circuit connections standard on screw clamp versions. - Mounting on 35 mm " DIN rail or 4mm (#6) screws - Screws in open ready-to-tighten position. Maximum Horsepower ratings 1- phase 50/60 HZ 115/ 120 V 230/ 240 V 3- phase 50/60 HZ 200/ 208 V 220/ 240 V 460/ 480 V 575/ 600 V Maximum inductive current in AC-3 category Type of connection Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a q hp hp hp hp hp hp A N.O. N.C. kg (lb.) 0.5 1 1.5 1.5 3 3 6 0.5 1.5 2 3 5 5 9 1 2 3 3 7.5 10 12 Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Solder pins for printed circuit board Slip-on 1 x 0.25 in., Weight 1 LP2-K0610kk 0.480 (1.05) 1 LP2-K0601kk 0.480 (1.05) 1 LP2-K06107kk 0.460 (1.00) 1 LP2-K06017kk 0.460 (1.00) 1 LP2-K06105kk 0.520 (1.14) 1 LP2-K06015kk 0.520 (1.14) 1 LP2-K0910kk 0.480 (1.05) 1 LP2-K0901kk 0.480 (1.05) 1 LP2-K09107kk 0.460 (1.00) 1 LP2-K09017kk 0.460 (1.00) 1 LP2-K09105kk 0.520 (1.14) 1 LP2-K09015kk 0.520 (1.14) 1 LP2-K1210kk 0.480 (1.05) 1 LP2-K1201kk 0.480 (1.05) 1 LP2-K12107kk 0.460 (1.00) 1 LP2-K12017kk 0.460 (1.00) Solder pins for printed circuit 1 LP2-K12105kk 0.520 (1.14) board 1 LP2-K12015kk 0.520 (1.14) c Auxiliary contact blocks and accessories, see page 20. a Standard control circuit voltages (variable delivery times, please consult your Regional Sales Office) Coil Selection Reversing contactors LC2-K (0.8 to 1.15 Uc) (0.85 to 1.1 Uc) Volts AC 50/60 Hz 12 20 24 q 36 42 48 110 127 200/ 208 220/ 230 230 230/ 240 256 277 Code J7 Z7 B7 C7 D7 E7 F7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts AC 50/60 Hz 400/ 415 480 T7 500 575 600 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72 660/ 690 380/ 400 400 Reversing contactors LC8-K (0.85 to 1.1 Uc) Volts AC 50/60 Hz 24 42 48 110 220 230/ 240 Code B7 D7 E7 F7 M7 U7 Reversing contactors LP2-K (0.8 to 1.15 Uc) Volts DC 12 20 24 q 36 48 60 72 100 110 125 155 174 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3 q When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil (AC control circuit voltage code Z7, DC control circuit voltage code ZD) so as to compensate for the incurred voltage drop. 5/98 1998 Square D All Rights Reserved 17

Selection - Reversing Contactors for Resistive Loads Control circuit: AC 3 and 4-pole reversing contactors c - Integrated mechanical interlock. Customer wiring required to connect coil terminations to electrical interlock. See page 27. - Pre-wired power circuit connections standard on screw clamp versions. - Mounting on 35 mm " DIN rail or 4mm (#6) screws. - Screws in open ready-to-tighten position. Non inductive loads Category AC-1 Maximum current at 50 C Type of connection Power poles Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a q Weight LC2-K090045kk A N.O. N.C. N.O. N.C. kg. (lb.) 3 1 LC2-K0910kk f 0.390 (0.86) 3 1 LC2-K0901kk f 0.390 (0.86) 4 LC2-K09004kk 0.380 (0.84) 3 1 LC2-K09107kk 0.370 (0.81) 20 Slip-on 1 x 0.25 in. 3 1 LC2-K09017kk 0.370 (0.81) 4 LC2-K090047kk 0.370 (0.81) 3 1 1 LC2-K09105kk 0.430 (0.95) Solder pins for circuit board 3 LC2-K09015kk 0.430 (0.95) 4 LC2-K090045kk 0.430 (0.95) LC8-K09105kk Reversing contactors for use in sensitive environments c Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor included as standard. - Integrated mechanical interlock. Customer wiring required to connect coil terminations to electrical interlock. See page 27. - Mounting on 35 mm " DIN rail or 4mm (#6) screws. - Screws in open, ready-to-tighten position. 3 1 LC8-K0910kk f 0.480 (1.05) 3 1 LC8-K0901kk f 0.480 (1.05) 4 LC8-K09004kk 0.470 (1.03) 3 1 LC8-K09107kk 0.460 (1.01) 20 Slip-on 1 x 0.25 in. 3 1 LC8-K09017kk 0.460 (1.01) 4 LC8-K090047kk 0.460 (1.01) 3 1 1 LC8-K09105kk 0.520 (1.14) Solder pins for circuit board 3 LC8-K09015kk 0.520 (1.14) 4 LC8-K090045kk 0.520 (1.14) c Auxiliary contact blocks and accessories, see page 20. a Control circuit voltage codes, see opposite page 19. q For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4-KE1FC (50 to 129 V) or LAF-KE1UG (130 to 250 V), see page 22. f Warning: this reversing contactor is pre-wired for reverse motor operation as standard. Coil Selection Reversing contactors LC2-K (0.8 to 1.15 Uc) (0.85 to 1.1 Uc) 200/ 220/ 230/ 380/ Volts AC 50/60 Hz 12 20 24 q 36 42 48 110 127 230 256 277 400 208 230 240 400 Code J7 Z7 B7 C7 D7 E7 F7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 400/ 480 660/ Volts AC 50/60 Hz 500 575 600 415 T7 690 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72 Reversing contactors LC8-K (0.85 to 1.1 Uc) Volts AC 50/60 Hz 24 42 48 110 220 230/ 240 Code B7 D7 E7 F7 M7 U7 Reversing contactors LP2-K (0.85 to 1.1 Uc) Volts DC 12 20 24 f 36 48 60 72 100 110 125 155 174 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3 q Warning: this reversing contactor is pre-wired for reverse motor operation as standard. f When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil (AC control circuit voltage code Z7, DC control circuit voltage code ZD) so as to compensate for the incurred voltage drop 18 1998 Square D All Rights Reserved 5/98

Control circuit: DC K-Line Mini-Contactors, Overload Relays and Accessories Selection - Reversing Contactors for Resistive Loads LP2-K0045kk 3- and 4-pole reversing contactors c - Integrated mechanical interlock. Customer wiring required to connect coil terminations to electrical interlock. See page 27. - Pre-wired power circuit connections standard on screw clamp versions. - Mounting on 35 mm " DIN rail or 4mm (#6) screws. - Screws in open ready-to-tighten position. Non inductive loads Category AC-1 Maximum current at 50 C Type of connection Power poles Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a q Weight A N.O. N.C. N.O. N.C. kg. (lb.) 20 Slip-on 1 x 0.25 in. 3 1 LP2-K0910kk q 0.480 (1.05) 3 1 LP2-K0901kk q 0.480 (1.05) 4 LP2-K09004kk 0.480 (1.05) 3 1 LP2-K09107kk 0.460 (1.01) 3 1 LP2-K09017kk 0.460 (1.01) 4 LP2-K090047kk 0.460 (1.01) 3 1 1 LP2-K09105kk 0.520 (1.14) Solder pins for circuit board 3 LP2-K09015kk 0.520 (1.14) 4 LP2-K090045kk 0.520 (1.14) c Auxiliary contact blocks and accessories, see page 20. a Standard control circuit voltages (variable delivery times, please consult you Regional Sales Office). Coil Selection Reversing contactors LC2-K (0.8 to 1.15 Uc) (0.85 to 1.1 Uc) Volts AC 50/60 Hz 12 20 24 q 36 42 48 110 127 200/ 208 220/ 230 230 230/ 240 256 277 Code J7 Z7 B7 C7 D7 E7 F7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts AC 50/60 Hz 400/ 415 480 T7 500 575 600 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72 660/ 690 380/ 400 400 Reversing contactors LC8-K (0.85 to 1.1 Uc) Volts AC 50/60 Hz 24 42 48 110 220 230/ 240 Code B7 D7 E7 F7 M7 U7 Reversing contactors LP2-K (0.85 to 1.1 Uc) Volts DC 12 20 24 f 36 48 60 72 100 110 125 155 174 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3 q Warning: this reversing contactor is pre-wired for reverse motor operation as standard. f When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil (AC control circuit voltage code Z7, DC control circuit voltage code ZD) so as to compensate for the incurred voltage drop 5/98 1998 Square D All Rights Reserved 19

Auxiliary Contacts and Timers LC1, LC7, LP1-K L-KN L-KN M LC1, LC7, LP1-K L-KN L-KT2 LC1, LC7, LP1-K 20 1998 Square D All Rights Reserved L-KN P 5/98

Selection - Auxiliary Contacts and Timers For type LCkK and LPkK contactors Instantaneous auxiliary contact blocks Recommended for standard applications. Clip-on front mounting, 1 block per contactor Type of connection Type of contactor Auxiliary Contacts Catalog number Weight Slip-on 1 x 0.25 in. LC1, LC2 LC7, LC8 LP1, LP2 3 or 4-pole LC1, LC2 LC7, LC8 LP1, LP2 3 or 4-pole N.O. N.C. kg (lb.) 2 L-KN20 0.045 (0.10) 2 L-KN02 0.045 (0.10) 1 1 L-KN11 0.045 (0.10) 4 L-KN40 0.045 (0.10) 3 1 L-KN31 0.045 (0.10) 2 2 L-KN22 0.045 (0.10) 1 3 L-KN13 0.045 (0.10) 4 L-KN04 0.045 (0.10) 2 L-KN207 0.045 (0.10) 2 L-KN027 0.045 (0.10) 1 1 L-KN117 0.045 (0.10) 4 L-KN407 0.045 (0.10) 3 1 L-KN317 0.045 (0.10) 2 2 L-KN227 0.045 (0.10) 1 3 L-KN137 0.045 (0.10) 4 L-KN047 0.045 (0.10) With terminal referencing conforming to standard EN 50012. Clip-on front mounting, 1 block per contactor with terminal referencing conforming to standard EN 50012 LC1, LC2 LC7, LC8 LP1, LP2 3-pole + N.O. LC1, LC2 LC7, LC8 LP1, LP2 4-pole 2 L-KN02M 0.045 (0.10) 1 1 L-KN11M 0.045 (0.10) 3 1 L-KN31M 0.045 (0.10) 2 2 L-KN22M 0.045 (0.10) 1 3 L-KN13M 0.045 (0.10) 1 1 L-KN11P 0.045 (0.10) 2 2 L-KN22P 0.045 (0.10) Electronic time delay auxiliary contact blocks - Relay output, with common point changeover contact, AC or DC 240 V, 2 A maximum. - Control voltage: 0.85 to 1.1 Uc. - Maximum switching capacity: 250 VA or 150 W. - Operating temperature: -10 to + 60 C. - Reset time: 1.5 s during the time delay period, 0.5 s after the time delay period. Clip-on front mounting, 1 block per contactor Voltage Type Timing range Auxiliary Contacts Catalog number Weight V sec. SPDT kg (lb.) AC or DC 24 to 48 On-delay 1 to 30 1 L-KT2E 0.040 (0.09) AC 110 to 240 On-delay 1 to 30 1 L-KT2U 0.040 (0.09) 5/98 1998 Square D All Rights Reserved 21

Selection - Accessories For LCkK and LPkK contactors LA4-Kkkk Coil suppressor modules incorporating LED indicator Mounting and connection Type For voltages: Sold in lots of Catalog number Weight kg (lb.) Clip-on mounting on the front of LC1 and LP1 contactors No tools required. Varistor c Diode + Zener diode a RC q AC and DC 12 to 24 V AC and DC 32 to 48 V AC and DC 50 to 129 V AC and DC 201 to 250 V DC 12 to 24 V DC 32 to 48 V AC 220 to 250 V 5 LA4-KE1B 0.010 (0.02) 5 LA4-KE1E 0.010 (0.02) 5 LA4-KE1FC 0.010 (0.02) 5 LA4-KE1UG 0.010 (0.02) 5 LA4-KC1B 0.010 (0.02) 5 LA4-KC1E 0.010 (0.02) 5 LA4-KU 0.010 (0.02) c Protection by limitation of the transient voltage up to 2 Uc maximum. Maximum reduction of transient voltage peaks. Slight time delay on drop-out (1.1 to 1.5 times the normal time). a No overvoltage or oscillation frequency. Polarized component. Slight time delay on drop-out (1.1 to 1.5 times the normal time). q Protection by limitation of the transient voltage up to 3 Uc maximum and limitation of the oscillation frequency. Slight time delay on drop-out (1.2 to 2 times the normal time). 22 1998 Square D All Rights Reserved 5/98

Selection - Accessories Mounting and marking accessories Description Application Sold in lots of Unit catalog number Weight kg (lb.) For mounting on 1 ' rail Clip-on 1 LA9-D973 0.025 (0.05) Mounting plates f 110/120 mm mounting For mounting on 2 ' rails 10 DX1-AP25 0.065 (0.14) centers Marker holder Clip-on Onto front of contactor 100 LA9-D90 0.001 (0.002) Clip-in markers 4 maximum per contactor Strips of 10 identical numbers 0 to 9 Strips of 10 identical capital letters A to Z 25 AB1-Rk t 0.002 (0.004) 25 AB1-Gk t 0.002 (0.004) 35mm " DIN rail (7.5mm deep x 2m long) 10 AM1-DP200 1.310 (2.88) 35mm " DIN rail (15mm deep x 2m long) 10 AM1-ED200 0.650 (1.44) DX1-AP25 Cabling accessories Description Application Sold in lots of Unit catalog number Weight kg (lb.) Paralleling links Set of 6 power connections Set of 4 power connections f t For 2-poles With screw clamp terminals 4 LA9-E01 0.010 (0.02) For 4-poles With screw clamp terminals 2 LA9-E02 0.015 (0.03) For 3-pole reversing contactors for motor control For 4-pole changeover contactor pairs For contactors with screw clamp terminals For contactors with screw clamp terminals Order 1 mounting plate for a contactor and 2 mounting plates for a reversing contactor. Complete the catalog number by replacing the k with the required character. 100 LA9-K0969 0.010 (0.02) 100 LA9-K0970 0.010 (0.02) LA9-E01 5/98 1998 Square D All Rights Reserved 23

Dimensions and Mounting Type LCkK and LPkK contactors Contactors LC1-K, LC7-K, LP1-K On panel On mounting rail AM1-DP200 or AM1 DE200 (35 mm " DIN rail) L-K 4mm (#6) screws 31 1.22 57 2.24 58 2.28 = 50 = 1.97 = 35 1.38 45 1.78 = 58 2.28 57 45 2.24 1.78 On one asymmetrical rail DZ5-MB with clip-on mounting plate LA9-D973 DX1-AP25 50 5 1.97 0.20 DZ5-ME5 57 2.24 21 0.83 = 35 1.38 = 45 1.78 5 0.20 120 4.72 110 4.33 On printed circuit board 57 2.24 27 1.06 45 1.78 8.65 0.34 === 58 2.28 50 1.97 53 2.09 10xØ1.3 45 1.78 Electronic time-delay auxiliary contact blocks L-KT On contactor L-KT 27 1.06 34 1.34 38 1.50 34 1.34 57 2.24 Suppressor modules LA4-Kk On contactor 25 0.99 58 2.26 58 2.28 22 0.87 6 0.24 22 0.87 57 2.24 Dimensions MM Inches 24 1998 Square D All Rights Reserved 5/98

Type LCkK and LP2kK reversing contactors K-Line Mini-Contactors, Overload Relays and Accessories Dimensions and Mounting Reversing contactors LC2-K, LC8-K, LP2-K On panel On mounting rail AM1-DP200 or AM1 DE200 (35 mm " DIN rail) L-K 4mm (#6) screws 31 1.22 57 2.24 58 2.28 = 80 3.15 90 3.54 = = 50 = 1.97 58 2.28 57 90 2.24 3.54 On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or on 2 mounting plates DX1-AP25. 2 x LA9-D973 2 x DX1-AP25 50 5 1.97 0.20 DZ5-ME5 45 1.78 57 21 2.24 0.83 = 35 = 1.38 90 3.54 5 0.20 120 4.72 110 4.33 On printed circuit board for reversing contactors or 2 contactors mounted side by side 57 27 2.24 1.06 90 3.54 8.65 === 0.34 = = = 8.65 0.34 58 2.28 50 1.97 53 2.09 20xØ1.3 45 1.78 45 1.78 Electronic time delay auxiliary contact blocks L-KT On reversing contactors L-KT 27 1.06 58 2.28 34 1.34 38 1.50 34 1.34 57 2.24 Suppressor modules LA4-Kk On reversing contactors 25 0.99 58 2.28 22 0.87 6 0.24 22.87 57 2.24 Dimensions MM Inches 5/98 1998 Square D All Rights Reserved 25

Schematics Type LCkK and LP2kK contactors and accessories 3-pole contactors LC1-K, LC7-K, LP1-K 3 P + N.O. 3 P + N.C. Integrated coil suppression device LC7-K 4-pole contactors LC1-K, LC7-K, LP1-K 4 P 2 P N.O. + P N.C. Integrated coil suppression device LC7-K Instantaneous auxiliary contacts L-K For contactors LCk-K and LPk-K 2 N.O. L-KN20 L-KN207 2 N.C. L-KN02 L-KN027 1 N.O. + 1 N.C. L-KN11 L-KN117 4 N.O. L-KN40 L-KN407 3 N.O. + 1 N.C. L-KN31 L-KN317 2 N.O. + 2 N.C. L-KN22 L-KN227 1 N.O. + 3 N.C. L-KN13 L-KN137 4 N.C. L-KN04 L-KN047 Terminal referencing conforming to standard EN 50012 For 3-pole contactors 2 N.C. L-KN02M 1 N.O. + 1 N.C. L-KN11M 3 N.O. + 1 N.C. L-KN31M 2 N.O. + 2 N.C. L-KN22M 1 N.O. + 3 N.C. L-KN13M For 4-pole contactors 1 N.O. + 1 N.C. L-KN11P 2 N.O. + 2 N.C. L-KN22P Electronic time delay auxiliary contact blocks L-KT For contactors LCk-K and LPk-K 1 C/O Suppressor modules LA4-KC LA4-KE 15 16 18 14 22 14 22 32 44 13/NO 21/NC 13/NO 21/NC 31/NC 43/NO 22 32 22 34 22 34 44 54 22 32 44 54 22 32 42 54 21/NC 31/NC 21/NC 33/NO 21/NC 33/NO 43/NO 53/NO 21/NC 31/NC 43/NO 53/NO 21/NC 31/NC 41/NC 53/NO 54 64 74 84 54 62 74 84 54 62 72 84 54 62 72 82 52 62 72 82 53/NO 63/NO 73/NO 83/NO 53/NO 61/NC 73/NO 83/NO 53/NO 61/NC 71/NC 83/NO 53/NO 61/NC 71/NC 81/NC 51/NC 61/NC 71/NC 81/NC 54 64 52 62 54 62 53/NO 63/NO 51/NC 61/NC 53/NO 61/NC T1/2 T2/4 T3/6 T4/8 2 R2 R4 4 1/L1 3/L2 5/L3 7/L4 1 R1 R3 3 T1/2 1/L1 T2/4 3/L2 T3/6 5/L3 14 13/NO T1/2 1/L1 T2/4 3/L2 T3/6 5/L3 22 21/NC 26 DC + 1998 Square D All Rights Reserved AC/ DC 5/98

Type LCkK and LPkK reversing contactors and accessories K-Line Mini-Contactors, Overload Relays and Accessories Schematics 3-pole reversing contactors LC2-K, LC8-K, LP2-K With screw clamp terminals 3 P + N.O. 3 P + N.C. Dashed lines indicate suggested customer wiring to electrically interlock coils Integrated coil suppression device LC8-K With Slip-on connectors or solder pins (printed circuit board) 3 P+ N.O. With Slip-on connectors or solder pins (printed circuit board) 3 P + N.C. 4-pole reversing contactors LC2-K, LC8-K, LP2-K With screw clamp terminals 4 P With Slip-on connectors or solder pins (printed circuit board) 4 P Integrated coil suppression device LC8-K Instantaneous auxiliary contact blocks L-K For contactors LCk-K and LP2-K 2 N.O. L-KN20 L-KN207 2 N.C. L-KN02 L-KN027 1 N.O. + 1 N.C. L-KN11 L-KN117 Terminal referencing conforming to standard EN 50012 1 N.O. + 1 N.C. L-KN11P For contactors LCk-K, LP2-K 4 N.O. L-KN40 L-KN407 3 N.O. + 1 N.C. L-KN31 L-KN317 2 N.O. + 2 N.C. L-KN22 L-KN227 1 N.O. + 3 N.C. L-KN13 L-KN137 4 N.C. L-KN04 L-KN047 For auxiliary contacts with terminal referencing conforming to standard EN 50012 see page 21. Electronic time delay contact blocks L-KT For contactors LCk-K and LPk-K 1 C/O Suppressor modules LA4-KC LA4-KE 15 16 18 54 64 74 84 54 62 74 84 54 62 72 84 54 62 72 82 52 62 72 82 53/NO 63/NO 73/NO 83/NO 53/NO 61/NC 73/NO 83/NO 53/NO 61/NC 71/NC 83/NO 53/NO 61/NC 71/NC 81/NC 51/NC 61/NC 71/NC 81/NC 54 64 52 62 54 62 53/NO 63/NO 51/NC 61/NC 53/NO 61/NC L1 L2 L3 N 1 1/L1 2 3 1/L2 4 5 1/L3 6 8 7 1N 1 2/L1 2 3 2/L2 4 5 2/L3 6 8 7 2N 2 1 4 3 6 5 8 7 2 1 4 3 6 5 8 7 T1/2 T2/4 T3/6 14 T1/2 T2/4 T3/6 14 T1/2 T2/4 T3/6 22 T1/2 T2/4 T3/6 22 1/L1 3/L2 5/L3 13/NO 1/L1 3/L2 5/L3 13/NO 1/L1 3/L2 5/L3 21/NC 1/L1 3/L2 5/L3 21/NC T1/2 T2/4 T3/6 14 T1/2 T2/4 T3/6 14 T1/2 T2/4 T3/6 22 T1/2 T2/4 T3/6 22 1/L1 3/L2 5/L3 13/NO 1/L1 3/L2 5/L3 13/NO 1/L1 3/L2 5/L3 21/NC 1/L1 3/L2 5/L3 21/NC DC + AC/ DC 5/98 1998 Square D All Rights Reserved 27

Characteristics Type LRkK overload relays Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 947, NF C 63-650, VDE 0660, BS 4941, UL 508, CSA 22.2 No. 14 Product certifications E164353 NKCR LR43364 3211-03 Protective treatment Conforming to IEC 68 (DIN 50016) TC (Fungus-proof, tropicalization protection) Degree of protection Conforming to VDE 0106 Protection against direct finger contact Storage -40 to +70 C (-40 to +158 F) Ambient air temperature around the device For normal operation (IEC 947) -20 to +55 C (-4 to +131 F) without derating Operating limit -30 to +60 C (-22 to +140 F) with derating c Maximum operating altitude Without derating 2000 m (6562 ft.) Vertical axis Horizontal axis Operating positions 90 90 90 90 Without derating With derating c Conforming to UL 94 Self-extinguishing material V1 Flame resistance Conforming to NF F 16-101 and 16-102 Conforming to requirement 2 Shock resistance, hot state Conforming to IEC 68, N.C. contact 10 gn (1/2 sine wave, 11 ms) Conforming to IEC 68, N.O. contact 10 gn Vibration resistance, hot state Conforming to IEC 68, N.C. contact 2 gn 5 to 300 Hz Conforming to IEC 68, N.O. contact 2 gn Safe separation of circuits Conforming to VDE 0106 and IEC 536 VLSV a, up to 400 V Cabling Minimum Maximum Maximum to IEC 947 Solid or stranded cable AWG 1 x 18 2 x 14 or 1 x 12 Solid cable mm 2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5 terminals Stranded cable without cable end mm 2 1 x 0.75 2 x 4 2 x 2.5 Stranded cable with cable end mm 2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5 Tightening torque Phillips no. 2 or 3/16 slotted head 0.8 N.m (7lb.-in.) Mounting Directly under the contactor or reversing contactor Made automatically when mounted under the contactor, as follows: - contactor terminal connected to overload relay terminal 96 on all products, Connections - contactor terminal 14 connected to overload relay terminal 95 on products with 3 P + N.O.. When using 3 P + N.C., or 4 P contactors, or the N.O. auxiliary contact marked 13-14, at a voltage other than the coil voltage, break off the link marked 14. (See page 31 for additional information) c Please consult your Regional Sales Office. a Very low safety voltage. Auxiliary contact characteristics Number of contacts 1 N.C. + 1 N.O. Conventional thermal current A 6 Short-circuit protection Maximum power of the controlled contactor coils (sealed) (Occasional operating cycles of contact 95-96) Maximum operational voltage Conforming to IEC 947, VDE 0660. gl fuse or supplementary protector GB2-CBkk AC DC A 6 max. AC, category AC-15 V 690 DC, category DC-13 V 250 V 24 48 110 220/ 230 400 415/ 440 600/ 690 VA 100 200 400 600 600 600 600 V 24 48 110 220 250 W 100 100 50 45 35 28 1998 Square D All Rights Reserved 5/98

Type LRkK overload relays K-Line Mini-Contactors, Overload Relays and Accessories Characteristics Electrical characteristics of the power circuit Rated operational voltage (Ue) Up to V 690 Conforming to BS 4941 V 690 Conforming to IEC 947 V 690 Rated insulation voltage (Ui) Conforming to VDE 0110 group C V 750 Conforming to UL 508, CSA 22.2 No. 14 V 600 Rated impulse withstand voltage (Uimp) kv 6 Frequency limits of the operational current Hz Up to 400 Power dissipated per pole W 2 Short-circuit protection and By circuit breaker Select in accordance with NEC and local codes coordination By fuses Maximum 400% of motor FLA Operating characteristics Sensitivity to phase failure Conforming to IEC 947 Yes Reset Manual or automatic Selected by means of a lockable and sealable switch on the front of the relay Signalling On front of relay Trip indicator Reset-Stop function Test function By pushbutton Pressing the Reset-Stop button: - actuates the N.C. contact - has no effect on the N.O. contact Pressing the Test button enables: - checking of the control circuit wiring - simulation of overload tripping (actuation of both N.C. and N.O. contacts, and of the trip indicator) Tripping curves Average operating time related to multiples of the current setting Class 10 A Time Class 10 A Time Class 10 A 2 h 1h 20 min 1 h 40 min 2 h 1h 20 min 1 h 40 min 20 min 10 min 6 min 4 min 2 min 1 min 40 s 20 s 10 s 6 s 4 s 2 s 20 min 10 min 6 min 4 min 2 min 1 min 40 s 20 s 10 s 6 s 4 s 2 s 1 2 1 s 1 1,2 1,5 2 3 4 5 6 8 10 15 1s 1 1,2 1,5 2 3 4 5 6 8 10 15 x setting current (Ir) x setting current (Ir) Balanced 3-phase operation, from cold state Balanced operation with 2-phases only, from cold state 1 Setting: at lower end of scale 2 Setting: at upper end of scale 5/98 1998 Square D All Rights Reserved 29

Selection Type LRkK overload relays LR2-K0301 LA7-K0064 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are ambient-compensated and phase-failure sensitive. Resetting can either be manual or automatic. Direct mounting: under the contactors with screw clamp terminals only; pre-wired terminals, see page 31. Separate mounting: using terminal block LA7-K0064 (see below). On the front face of the overload relay: - selection of reset mode: Manual (marked H) or Automatic (marked A), - red pushbutton: Trip Test function, - blue pushbutton: Stop and manual Reset, - yellow trip flag indicator: overload relay tripped. Short-circuit protection for North By circuit breaker Select in accordance with NEC and local codes American applications By fuses Maximum 400% of motor FLA Relay setting range European type fuses Maximum rating Type Catalog number Weight am gl BS88 A A A A kg (lb.) Class 10 A (the standard specifies a tripping time of between 2 and 10 seconds at 7.2 In) 0.11 to 0.16 0.25 0.5 LR2-K0301 0.145 (0.32) 0.16 to 0.23 0.25 0.5 LR2-K0302 0.145 (0.32) 0.23 to 0.36 0.5 1 LR2-K0303 0.145 (0.32) 0.36 to 0.54 1 1.6 LR2-K0304 0.145 (0.32) 0.54 to 0.8 1 2 LR2-K0305 0.145 (0.32) 0.8 to 1.2 2 4 6 LR2-K0306 0.145 (0.32) 1.2 to 1.8 2 6 6 LR2-K0307 0.145 (0.32) 1.8 to 2.6 4 8 10 LR2-K0308 0.145 (0.32) 2.6 to 3.7 4 10 16 LR2-K0310 0.145 (0.32) 3.7 to 5.5 6 16 16 LR2-K0312 0.145 (0.32) 5.5 to 8 8 20 20 LR2-K0314 0.145 (0.32) 8 to 11.5 10 25 20 LR2-K0316 0.145 (0.32) 10 to 14 16 32 25 LR2-K0321 0.145 (0.32) 12 to 16 20 40 32 LR2-K0322 0.145 (0.32) Overload relays without single phase sensitivity Class 10 A: To order, replace the prefix LR2 by LR7 in the catalog numbers selected from above (only applicable to overload relays LR2-K0305 to LR2-K0322). Example: LR7-K0308. Accessory Description Type of connection Catalog number Weight kg (lb.) Terminal block for separate clip-on mounting LA7-K0064 0.100 (0.22) of the overload relay on 35 mm " DIN rail 30 1998 Square D All Rights Reserved 5/98

Dimensions, Mounting, Schematics Type LRkK overload relays Protection components LR2-K Direct mounting beneath the contactor 8 = 35 = 0.31 1.38 = 50 = 1.97 4mm (#6) screws 58 2.28 116 4.57 Separate mounting with terminal block LA7-K0064 on 35 mm " DIN rail (AM1-DP200 or AM1-DE200) 38 80 1.50 3.15 75 45 2.95 1.77 c 65 2.56 45 1.77 AM1- DP200 DE200 c 78.5mm / 3.09 in. 86mm / 3.38 in. LR2-K LR2-K + LCk-K Built-in wiring scheme 1 2 3 4 5 6 A H 95 96 Reset/stop 97 98 1 2 3 5 13 4 6 14 97 95 98 96 KM1 O KM1 96 95 14 13 95 96 Internal Links 2 4 6 LR2K Overload Relays feature built-in wiring to save time and materials when all five links of the overload relay are connected to a K-Line contactor with an integrated N.O. (normally-open) auxiliary contact. Terminal 96 of the N.C. (normally-closed) overload relay contact (95-96) will be internally linked in series with terminal of the contactor operating coil. Terminal 95 of the N.C. overload relay contact (95-96) will be internally linked in series with terminal 14 of N.O. coil holding contact (13-14) of the contactor. These internal links help to eliminate additional wiring when using a conventional 3-wire control circuit similar to the diagram shown. L1 Stop Start 95 96 L2 13 14 Internal Links If integrated wiring between contactor and overload relay is not desired, break off the two links on the overload relay as indicated. Dimensions MM Inches 5/98 1998 Square D All Rights Reserved 31

Characteristics Type LPk-K low consumption contactors Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Conforming to standards Approvals Conforming to IEC 947 V 690 Conforming to VDE 0110 gr C V 750 Conforming to BS 5424, NF C 20-040 V 690 Conforming to CSA 22.2 No. 14, UL 508 V 600 Meets the essential requirements of the LV & EMC directives LPk-K06, LPk-K09, LPk-K12 kv 8 IEC 947, NF C 63-110, VDE 0660, BS 5424, UL 508, CSA 22.2 No. 14 E164862 NLDX (screw clamp) LR43364 3211-04 Protective treatment Conforming to IEC 68 (DIN 50016) TC (Fungus-proof, Tropicalization protection) Degree of protection Conforming to VDE 0106 Protection against direct finger contact Ambient air temperature Storage - 50 to + 80 C (-58 to +176 F) around the device Operation - 25 to + 50C (-13 to +122 F) Maximum operating altitude Without derating 2000 m (6562 ft) Vertical axis Horizontal axis E164862 NLDX2 (Slip-on & solder pin) 90 90 90 Operating positions 180 Without derating 90 Without derating Derate current carrying capability by 15% when not mounted vertically Flame resistance Shock resistance (1/2 sine wave, 11 ms) Conforming to UL 94 Self-extinguishing materials V1 Conforming to NF F 16-101 and 16-102 Conforming to requirement 2 Contactor open Contactor closed Vibration resistance Contactor open 2 g 5 to 300 Hz Contactor closed 4 g Safe separation of circuits Conforming to VDE 0106 and IEC 536 TBTS c, up to 400 V Cabling Min Max Max to IEC 947 Solid or stranded cable AWG 1 x 18 2 x 14 or 1 x 12 - Solid cable mm 2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5 terminals Stranded cable without cable end mm 2 1 x 0.75 2 x 4 2 x 2.5 Stranded cable with cable end mm 2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5 Slip-on connectors Clip 2 x 2.8mm or 1 x 6.35mm (2 x.110 in. or 1 x.250 in.) Solder pins for printed circuit board Tightening torque Terminal referencing c Very low safety voltage. With locating device between power and control circuits Phillips no. 2 or 3/16" slotted head screwdriver Conforming to standards EN 50005 and EN 50012 10 g 15 g 4 mm x 35 microns 0.8 to 1.3 N m (7 to 11.5 lb-in) Up to 3 contacts 32 1998 Square D All Rights Reserved 5/98

Characteristics Type LPk-K low consumption contactors Pole characteristics Conventional rated thermal current (Ith) For ambient temperature 50 C ( 122 F) A 20 Rated operational frequency Hz 50/60 Frequency limits of the operational current Hz Up to 400 Rated operational voltage (Ue) V 690 Rated making capacity Rated breaking capacity Permissible short time rating I rms conforming to NF C 63-110 and IEC 947 LPk-K06, LPk-K09 LPk-K12 Conforming to NF C 63-110 and IEC 947 LPk-K06, LPk-K09 I rms LPk-K12 Open mounted, for a time t from cold state (θ 50 C) LPk-K06, LPk-K09 LPk-K12 A V A A 110 144 220/ 230 110 380/ 400 110 415 440 500 110 110 120 80 80 660/ 690 70 70 1 s 5 s 10 s 30 s 1 min 3 min 15 min By circuit breaker Select in accordance with NEC and local codes Short-circuit protection By fuses Max 400% of motor FLA Average impedance per pole At Ith and 50 Hz mω 3 Utilization in category AC-1 resistive circuits, heating, lighting (Ue 440 V) Utilization in category AC-3 Squirrel cage motors Utilization in category AC-3 Squirrel cage motors 90 115 Maximum rated operational current for a temperature 50 C A 20 Rated operational current limits in relation to on-load factor and operating frequency Increase in operational current by paralleling poles Operational power according to the voltage LPk-K06 LPk-K09 A 85 105 Voltage 115 220 50 or 60Hz V Motor ratings Motor ratings Motor LPk-K12 ratings % utilization of operational power in relation to the maximum operating rate Operational power according to the voltage LCk-K06, LPk-K06 LCk-K09, LPk-K09 LCk-K12, LPk-K12 LCk-K16, LPk-K12 Voltage 50 or 60Hz Motor ratings Motor ratings Motor ratings 80 100 60 75 45 55 40 50 On-load factor 90% 60% 30% 300 op. cycles/hour 13 15 18 120 op. cycles/hour 15 18 19 30 op. cycles/hour 19 20 20 20 25 Apply the following coefficients to the current values given above. These take into account the often unbalanced current distribution between poles 2 poles in parallel: K = 1.60 3 poles in parallel: K = 2.25 4 poles in parallel: K = 2.80 220/ 240 380/ 415 440/ 480 500/ 600 660/ 690 1-ph 1-ph 3-ph 3-ph 3-ph 3-ph 3-ph kw 0.37 0.75 1.5 2.2 3 3 3 kw 0.55 1.1 2.2 4 4 4 4 kw 3 5.5 V 5.5 4 (480) 4 4 Op. cycles/h 600 900 1200 Puissance 100% 75% 50% 115 220 220/ 208 220/ 240 460/ 480 575/ 600 1-ph 1-ph 3-ph 3-ph 3-ph 3-ph hp 0.5 1 1.5 3 3 3 hp 0.5 1.5 2 3 5 5 hp 1 2 3 3 7.5 10 Not for North American Applications. Not UL Listed or CSA Certified. 5/98 1998 Square D All Rights Reserved 33

Characteristics Type LPk-K low consumption contactors Control circuit characteristics Type LP4 LP5 Rated control circuit voltage (Uc) V DC 12 to 72 Control voltage limits For operation 0.7 to 1.30 Uc ( 50 C) single-voltage coil For drop-out 0.10 Uc Inrush W 1.8 Average consumption at 20 C and at Uc Sealed W 1.8 Heat dissipation W 1.8 Operating time at 20 C and at Uc Between coil energization and: - opening of the N.C. contacts - closing of the N.O. contacts Between coil de-energization and: - opening of the N.O. contacts - closing of the N.C. contacts ms ms ms ms 25 to 35 30 to 40 10 to 20 15 to 25 Maximum immunity to micro breaks ms 2 Maximum operating rate In operating cycles per hour 3600 Mechanical durability at Uc In millions of operating cycles Wide range DC coil 30 5 34 1998 Square D All Rights Reserved 5/98

Characteristics Type LPk-K low consumption contactors Auxiliary contact characteristics of contactors and instantaneous contact blocks On LP4, LP5-K 1 Number of contacts On L-K 2 max. Rated operational voltage (Ue) Up to V 690 Conforming to BS 5424 V 690 Conforming to IEC 947 V 690 Rated insulation voltage (Ui) Conforming to VDE 0110 group C V 750 Conforming to CSA 22.2 No. 14, UL 508 V 600 Conventional rated thermal current (lth) For ambient temperature 50 C A 10 Frequency of operational current Hz Up to 400 U min (DIN 19 240) V 17 (reliability <10-8 at 24V) Minimum switching capacity I min ma 5 Short-circuit protection Conforming to IEC 947 and VDE 0660, gl fuse A 10 Rated making capacity Conforming to IEC 947 I rms A 110 1 s A 80 Overload current Permissible for 500 ms A 90 100 ms A 110 Insulation resistance MΩ > 10 Non-overlap distance Linked contacts conforming to INRS and BIA specs. mm 0.5 Operational power of contacts conforming to IEC 947 AC supply, category AC-15 Electrical durability (valid up to 3600 operating cycles per hour) on an inductive load such as the coil of an electromagnet: making current (power factor 0.7) = 10 times the breaking current (power factor 0.4). V 24 48 110/ 127 220/ 230 380/ 400 400 600/ 690 DC supply, category DC-13 Electrical durability (valid up to 1200 operating cycles per hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. V 24 48 110 220 440 600 1 million operating cycles VA 48 96 240 440 800 880 1200 W 120 80 60 52 51 50 3 million operating cycles VA 17 34 86 158 288 317 500 W 55 38 30 28 26 25 10 million operating cycles VA 7 14 36 66 120 132 200 W 15 11 9 8 7 6 Occasional making capacity VA 1000 2050 5000 10000 14000 13000 9000 W 720 600 400 300 230 200 Power broken in VA 1 Breaking limit of contacts valid for: 16 000 maximum of 50 operating cycles at 10 000 10 s intervals (breaking current = 8000 making current x power factor 0.7). 6000 2 Electrical durability of contacts for: - 1 million operating cycles (2a) - 3 million operating cycles (2b) - 10 million operating cycles (2c). 3 Breaking limit of contacts valid for: - maximum of 20 operating cycles at 10 s intervals with current passing for 0.5 s per operating cycle. 4 Thermal limit. 5000 4000 3000 2000 1000 800 600 500 400 300 200 100 80 60 40 2b 24 48 110 220 1 4 2a 120 2c 380 500 440 690 V Power broken in W 1000 700 500 300 250 200 Time constant in ms 200 140 100 50 20 100 80 60 50 40 30 20 10 8 6 4 3 2a 2b 2c 12 24 48 110 220 440 600 V 5/98 1998 Square D All Rights Reserved 35

Selection - Low Consumption Contactors for Motor Control Control circuit: DC low consumption coil 3-pole contactors c - Compatible with programmable controller outputs. - LED indicator incorporated. - Wide range coil (0.7 to 1.30 Uc), suppressor fitted as standard, consumption 1.8 W. - Mounting on 35 mm " DIN rail or 4 mm (#6) screws. - Screws in open ready-to-tighten position. Kilowatt ratings for International applications Motor control in category AC-3 Maximum operational current 440 V Standard power ratings of 3-phase motors 220 V 230 V 380 V 415 V 440/500 V 660/690 V Type of connection Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a Weight LP4-K06105kkk A kw kw kw N.O. N.C. kg (lb.) 6 1.5 2.2 3 9 2.2 4 4 12 3 5.5 4 (> 440) 5.5 (440) Horsepower ratings for North American applications Maximum inductive current in AC-3 category Maximum Horsepower Rating 1 - Phase 50/60 Hz 115/ 120 V 230/ 240 V 3 - Phase 50/60 Hz 200/ 208 V 220/ 240 V 460/ 480 V 575/ 600 V Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board Type of connection 1 LP4-K0610kkk 0.235 (0.52) 1 LP4-K0601kkk 0.235 (0.52) 1 LP4-K06107kkk 0.235 (0.52) 1 LP4-K06017kkk 0.235 (0.52) 1 LP4-K06105kkk 0.265 (0.58) 1 LP4-K06015kkk 0.265 (0.58) 1 LP4-K0910kkk 0.235 (0.52) 1 LP4-K0901kkk 0.235 (0.52) 1 LP4-K09107kkk 0.235 (0.52) 1 LP4-K09017kkk 0.235 (0.52) 1 LP4-K09105kkk 0.265 (0.58) 1 LP4-K09015kkk 0.265 (0.58) 1 LP4-K1210kkk 0.235 (0.52) 1 LP4-K1201kkk 0.235 (0.52) 1 LP4-K12107kkk 0.235 (0.52) 1 LP4-K12017kkk 0.235 (0.52) 1 LP4-K12105kkk 0.265 (0.58) 1 LP4-K12015kkk 0.265 (0.58) Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a Weight A hp hp hp hp hp hp N.O. N.C. kg (lb.) 6 0.5 1 1.5 1.5 3 3 9 0.5 1.5 2 3 5 5 12 1 2 3 3 7.5 10 Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. or 2 x 0.11 in. 1 LP4-K0610kkk 0.235 (0.52) 1 LP4-K0601kkk 0.235 (0.52) 1 LP4-K06107kkk 0.235 (0.52) 1 LP4-K06017kkk 0.235 (0.52) 1 LP4-K06105kkk 0.265 (0.58) 1 LP4-K06015kkk 0.265 (0.58) 1 LP4-K0910kkk 0.235 (0.52) 1 LP4-K0901kkk 0.235 (0.52) 1 LP4-K09107kkk 0.235 (0.52) 1 LP4-K09017kkk 0.235 (0.52) 1 LP4-K09105kkk 0.265 (0.58) 1 LP4-K09015kkk 0.265 (0.58) 1 LP4-K1210kkk 0.235 (0.52) 1 LP4-K1201kkk 0.235 (0.52) 1 LP4-K12107kkk 0.235 (0.52) 1 LP4-K12017kkk 0.235 (0.52) Solder pins for printed 1 LP4-K12105kkk 0.265 (0.58) circuit board 1 LP4-K12015kkk 0.265 (0.58) c Auxiliary contacts and accessories, see page 39. a Standard control circuit voltages (variable delivery times, please consult your Regional Sales Office). Volts DC 12 24 48 72 Code JW3 BW3 EW3 SW3 36 1998 Square D All Rights Reserved 5/98

Selection - Reversing Low Consumption Contactors for Motor Control Control circuit: DC low consumption coil 3-pole reversing contactors c - Compatible with programmable controller outputs. - LED indicator incorporated. - Wide range coil (0.7 to 1.30 Uc), suppressor fitted as standard, consumption 1.8 W. - Mechanical interlock incorporated. Customer wiring required to connect coil terminations to electrical interlock. See page 42. - Pre-wired power circuit connections as standard on screw clamp versions. - Mounting on 35 mm " DIN rail or 4 mm (#6) screws. - Screws in open ready-to-tighten position. LP5-K06105kkk Kilowatt ratings for International applications Motor control in category AC-3 Maximum operational current 440 V Standard power ratings of 3-phase motors 220 V 230 V 380 V 415 V 440/500 V 660/690 V Type of connection Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a Weight A kw kw kw N.O. N.C. kg (lb.) 6 1.5 2.2 3 9 2.2 4 4 12 3 5.5 4 (> 440) 5.5 (440) Horsepower ratings for North American applications Maximum inductive current in AC-3 category Maximum Horsepower Rating 1 - Phase 50/60 Hz 115/ 120 V 230/ 240 V 3 - Phase 50/60 Hz 200/ 208 V 220/ 240 V 460/ 480 V 575/ 600 V Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board Type of connection 1 LP5-K0610kkk 0.490 (1.08) 1 LP5-K0601kkk 0.490 (1.08) 1 LP5-K06107kkk 0.470 (1.03) 1 LP5-K06017kkk 0.470 (1.03) 1 LP5-K06105kkk 0.530 (1.17) 1 LP5-K06015kkk 0.530 (1.17) 1 LP5-K0910kkk 0.490 (1.08) 1 LP5-K0901kkk 0.490 (1.08) 1 LP5-K09107kkk 0.470 (1.03) 1 LP5-K09017kkk 0.470 (1.03) 1 LP5-K09105kkk 0.530 (1.17) 1 LP5-K09015kkk 0.530 (1.17) 1 LP5-K1210kkk 0.490 (1.08) 1 LP5-K1201kkk 0.490 (1.08) 1 LP5-K12107kkk 0.470 (1.03) 1 LP5-K12017kkk 0.470 (1.03) 1 LP5-K12105kkk 0.530 (1.17) 1 LP5-K12015kkk 0.530 (1.17) Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a A hp hp hp hp hp hp N.O. N.C. kg (lb.) 6 0.5 1 1.5 1.5 3 3 9 0.5 1.5 2 3 5 5 12 1 2 3 3 7.5 10 Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board Slip-on 1 x 0.25 in. or 2 x 0.11 in. Weight 1 LP5-K0610kkk 0.490 (1.08) 1 LP5-K0601kkk 0.490 (1.08) 1 LP5-K06107kkk 0.470 (1.03) 1 LP5-K06017kkk 0.470 (1.03) 1 LP5-K06105kkk 0.530 (1.17) 1 LP5-K06015kkk 0.530 (1.17) 1 LP5-K0910kkk 0.490 (1.08) 1 LP5-K0901kkk 0.490 (1.08) 1 LP5-K09107kkk 0.470 (1.03) 1 LP5-K09017kkk 0.470 (1.03) 1 LP5-K09105kkk 0.530 (1.17) 1 LP5-K09015kkk 0.530 (1.17) 1 LP5-K1210kkk 0.490 (1.08) 1 LP5-K1201kkk 0.490 (1.08) 1 LP5-K12107kkk 0.470 (1.03) 1 LP5-K12017kkk 0.470 (1.03) Solder pins for printed 1 LP5-K12105kkk 0.530 (1.17) circuit board 1 LP5-K12015kkk 0.530 (1.17) c Auxiliary contacts and accessories, see pages 39. a Standard control circuit voltages (variable delivery times, please consult your Regional Sales Office). Volts DC 12 24 48 72 Code JW3 BW3 EW3 SW3 5/98 1998 Square D All Rights Reserved 37

Selection - Low Consumption Contactors for Resistive Loads Control circuit: DC low consumption coil 3- and 4-pole contactors c - Compatible with programmable controller outputs. - LED indicator incorporated as standard. - Wide range coil (0.7 to 1.30 Uc), suppressor fitted as standard, consumption 1.8 W. - Mounting on 35 mm " DIN rail or 4 mm (#6) screw. - Screws in open ready-to-tighten position. Non-inductive loads Category AC-1 Maximum current at q 50 C Type of connection Power poles Auxiliary contacts Basic catalog number. Complete with code indicating control circuit voltage a Weight LP4-K090047kkk A N.O. N.C. N.O. N.C. kg (lbs.) 20 Slip-on 1 x 0.25 in. or 2 x 0.11 in. Solder pins for printed circuit board 3 1 LP4-K0910kkk 0.235 (0.52) 1 LP4-K0901kkk 0.235 (0.52) 4 LP4-K09004kkk 0.235 (0.52) 2 2 LP4-K09008kkk 0.235 (0.52) 3 1 LP4-K09107kkk 0.235 (0.52) 1 LP4-K09017kkk 0.235 (0.52) 4 LP4-K090047kkk 0.235 (0.52) 2 2 LP4-K090087kkk 0.235 (0.52) 3 1 LP4-K09105kkk 0.265 (0.58) 1 LP4-K09015kkk 0.265 (0.58) 4 LP4-K090045kkk 0.265 (0.58) 2 2 LP4-K090085kkk 0.265 (0.58) 3- and 4-pole reversing contactors c - Compatible with programmable controller outputs. - LED indicator incorporated. - Wide range coil (0.7 to 1.30 Uc), suppressor fitted as standard, consumption 1.8 W. - Mechanical interlock incorporated. Customer wiring required to connect coil terminations to electrical interlock. See page 42. - Pre-wired power circuit connections as standard on screw clamp versions. - Mounting on 35 mm " Din rail or 4mm (#6) screw. - Screws in open ready-to-tighten position. Power poles Auxiliary contacts LP5-K0910kkk Non-inductive loads Category AC-1 Maximum current at q 50 C Type of connection Basic catalog number. Complete with code indicating control circuit voltage a Weight A N.O. N.C. N.O. N.C. kg (lb.) 20 Slip-on 1 x 0.25 in. Solder pins for printed circuit board 3 1 LP5-K0910kkk q 0.490 (1.08) 3 1 LP5-K0901kkk q 0.490 (1.08) 4 LP5-K09004kkk 0.490 (1.08) 3 1 LP5-K09107kkk 0.470 (1.03) 3 1 LP5-K09017kkk 0.470 (1.03) 4 LP5-K090047kkk 0.530 (1.17) 3 1 LP5-K09105kkk 0.530 (1.17) 3 1 LP5-K09015kkk 0.530 (1.17) 4 LP5-K090045kkk 0.530 (1.17) c Auxiliary contact blocks and accessories, see pages 39. a Standard control circuit voltages (variable delivery times, please consult your Regional Sales Office). Volts DC 12 24 48 72 Code JW3 BW3 EW3 SW3 q Warning: this reversing contactor is prewired for reverse motor operation 38 1998 Square D All Rights Reserved 5/98

Selection - Auxiliary Contacts and Accessories For type LPk-K low consumption contactors Instantaneous auxiliary contact blocks Clip-on front mounting, 1 block per contactor Auxiliary contacts Type of connection Type of contactor Catalog number Weight N.O. N.C. kg (lb.) 2 L-KN20 0.045 (0.10) 3- or 4-pole 2 L-KN02 0.045 (0.10) L-KN 1 1 L-KN11 0.045 (0.10) 2 L-KN207 0.045 (0.10) Slip-on 1 x 0.25 in. 3- or 4-pole 2 L-KN027 0.045 (0.10) 1 1 L-KN117 0.045 (0.10) Instantaneous auxiliary contact blocks (with terminal referencing conforming to EN 50012) Clip-on front mounting, 1 block per contactor with terminal referencing conforming to standard EN 50012 2 L-KN02M 0.045 (0.10) 3-pole, 6 and 9 A 1 1 L-KN11M 0.045 (0.10) 4-pole, 9 A 1 1 L-KN11P 0.045 (0.10) Electronic time delay auxiliary contact blocks L-KT2k - Relay output, with common point changeover contact, AC or DC 240 V, 2 A maximum. - Control voltage: 0.85 to 1.1 Uc. - Maximum switching capacity: 250 VA or 150 W. - Operating temperature: -10 to + 60 C. - Reset time: 1.5 s during the time-delay period, 0.5 s after the time delay period. Clip-on front mounting, 1 block per contactor Voltage Type Timing range Auxiliary contacts Catalog number Weight V sec. SPDT kg (lb.) AC or DC 24 to 48 On-delay 1 to 30 1 L-KT2E 0.040 (0.09) AC 110 to 240 On-delay 1 to 30 1 L-KT2U 0.040 (0.09) Mounting and marking accessories Description Application Sold in lots of Unit catalog number Weight kg (lb.) DX1-AP25 LA9-E01 For mounting on 1 ' rail Clip-on 1 LA9-D973 0.025 (0.05) Mounting plates f 110/120 mm mounting For mounting on 2 ' rails 10 DX1-AP25 0.065 (0.14) centers Marker holder Clip-on Onto front of contactor 100 LA9-D90 0.001 (0.002) Clip-in markers 4 maximum per contactor Strips of 10 identical numbers 0 to 9 Strips of 10 identical capital letters A to Z 25 AB1-Rk t 0.002 (0.004) 25 AB1-Gk t 0.002 (0.004) 35mm " DIN rail (7.5 mm deep x 2 m long) 10 AM1-DP200 1.310 (2.88) 35mm " DIN rail (15 mm deep x 2 m long) 10 AM1-ED200 0.650 (1.44) Cabling accessories Description Application Sold in lots of Unit catalog number Weight kg (lb.) Paralleling links Set of 6 power connections Set of 4 power connections f t For 2-poles With screw clamp terminals 4 LA9-E01 0.010 (0.02) For 4-poles With screw clamp terminals 2 LA9-E02 0.015 (0.03) For 3-pole reversing contactors for motor control For 4-pole changeover contactor pairs For contactors with screw clamp terminals For contactors with screw clamp terminals Order 1 mounting plate for a contactor and 2 mounting plates for a reversing contactor. Complete the catalog number by replacing the k with the required character. 100 LA9-K0969 0.010 (0.02) 100 LA9-K0970 0.010 (0.02) 5/98 1998 Square D All Rights Reserved 39

Dimensions and Mounting Type LPk-K low consumption contactors Reversing Contactors LP4-K On panel On mounting rail AM1-DP200 or AM1 DE200 (35 mm " DIN rail) L-K 4mm (#6) screws 31 1.22 57 2.24 58 2.28 = 50 = 1.97 = 35 1.38 45 1.78 = 58 2.28 57 45 2.24 1.78 On one asymmetrical rail DZ5-MB with clip-on mounting plate LA9-D973 DX1-AP25 50 5 1.97 0.20 DZ5-ME5 57 2.24 21 0.83 = 35 1.38 = 45 1.78 5 0.20 120 4.72 110 4.33 On printed circuit board 57 2.24 27 1.06 45 1.78 8.65 0.34 === 58 2.28 50 1.97 53 2.09 10xØ1.3 45 1.78 Electronic time delay contact blocks L-KT On contactor L-KT 27 1.06 58 2.28 34 1.34 38 1.50 34 1.34 57 2.24 Dimensions MM Inches 40 1998 Square D All Rights Reserved 5/98

Type LPk-K low consumption reversing contactors K-Line Mini-Contactors, Overload Relays and Accessories Dimensions and Mounting Reversing contactors LP5-K On panel On mounting rail AM1-DP200 or AM1 DE200 (35 mm " DIN rail) L-K 4mm (#6) screws 31 1.22 57 2.24 58 2.28 = 80 3.15 90 3.54 = = 50 = 1.97 58 2.28 57 90 2.24 3.54 On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or on 2 mounting plates DX1-AP25. 2 x LA9-D973 2 x DX1-AP25 50 5 1.97 0.20 DZ5-ME5 45 1.78 57 21 2.24 0.83 = 35 = 1.38 90 3.54 5 0.20 120 4.72 110 4.33 On printed circuit board for reversing contactors or 2 contactors mounted side by side 8.65 === 0.34 = = = 8.65 0.34 57 27 2.24 1.06 90 3.54 58 2.28 50 1.97 53 2.09 20xØ1.3 45 1.78 45 1.78 Electronic time delay contact blocks L-KT On reversing contactors L-KT 27 1.06 58 2.28 34 1.34 38 1.50 34 1.34 57 2.24 Dimensions MM Inches 5/98 1998 Square D All Rights Reserved 41

Schematics Type LPk-K 3-pole low consumption contactors and reversing contactors and accessories 3-pole contactors LP4-K 3-pole + N.O. 1/L1 3/L2 5/L3 T1/2 T2/4 T3/6 13/NO 14 3-pole + N.C. 1/L1 3/L2 T1/2 T2/4 5/L3 T3/6 21/NC 22 Integrated coil suppression device LP4-K - + 3-pole reversing contactors LP5-K With screw clamp terminals 3-pole + N.O. 1/L1 3/L2 T1/2 T2/4 T3/6 5/L3 13/NO 14 1/L1 T1/2 3/L2 T2/4 5/L3 T3/6 13/NO 14 Dashed lines indicate suggested customer wiring to electrically interlock coils. 3-pole + N.C. 1/L1 3/L2 T1/2 T2/4 T3/6 5/L3 21/NC 22 1/L1 3/L2 5/L3 21/NC Integrated coil suppression device LP5-K - + With Slip-on connectors or solder pins for printed circuit boards 3-pole + N.O. 3-pole + N.C. Instantaneous auxiliary contact blocks L-K For 3-pole contactors LPk-K Terminal referencing conforming to standard EN 50012 2 N.O. L-KN20 L-KN207 2 N.C. L-KN02 L-KN027 1 N.O. + 1 N.C. L-KN11 L-KN117 2 N.C. L-KN02 1 N.O. + 1 N.C. L-KN11M Electronic time delay auxiliary contact blocks L-KT For 3-pole contactors LPk-K 1 C/O 15 16 18 54 53/NO 64 63/NO 52 51/NC 62 61/NC 54 53/NO 62 61/NC 22 21/NC 32 31/NC 22 21/NC 34 33/NO T1/2 1/L1 T2/4 T1/2 T2/4 T3/6 3/L2 T3/6 22 5/L3 14 13/NO T1/2 1/L1 T2/4 3/L2 T3/6 5/L3 14 13/NO T1/2 1/L1 T2/4 3/L2 T3/6 5/L3 22 21/NC T1/2 1/L1 T2/4 3/L2 T3/6 5/L3 22 21/NC 42 1998 Square D All Rights Reserved 5/98

Schematics Type LPk-K low consumption contactors and reversing contactors and accessories 4-pole contactors LP4-K 4-pole 1/L1 3/L2 5/L3 T1/2 T2/4 T3/6 7/L4 T4/6 2-pole N.O. + 2-pole N.C. 1 R1 R3 2 R2 R4 22 3 Integrated coil suppression device LP4-K - + 4-pole reversing contactors LP5-K With screw clamp connections 4-pole 1/L1 1/L2 1 2 3 4 1/L3 1N 5 6 7 8 2/L1 1 2 2/L2 3 4 2/L3 5 6 2N 7 8 With Slip-on connectors or solder pins for printed circuit boards 4-pole 1 2 3 Integrated coil suppression device LP5-K - + L1 L2 L3 N 4 5 7 6 8 1 2 3 4 Instantaneous auxiliary contact blocks L-K For 4-pole contactors LPk-K 2 N.O. L-KN20 L-KN207 2 N.C. L-KN02 L-KN027 1 N.O. + 1 N.C. L-KN11 L-KN117 Terminal referencing conforming to standard EN 50012 1 N.O. + 1 N.C. L-KN11P Electronic time delay auxiliary contact blocks L-KT For 4-pole contactors LPk-K 1 C/O 15 16 18 54 53/NO 64 63/NO 52 51/NC 5 7 6 8 62 61/NC 54 53/NO 62 61/NC 14 13/NO 22 21/NC 5/98 1998 Square D All Rights Reserved 43

Contactors - Definitions and Comments Altitude Ambient air temperature Rated operational current (Ie) Rated conventional thermal current (Ith) c Permissible short time rating Rated operational voltage (Ue) Rated control circuit voltage (Uc) Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Rated operational power (expressed in kw) Rated breaking capacity a Rated making capacity a On-load factor (m) Pole impedance Electrical durability Mechanical durability The low oxygen atmosphere at high altitudes reduces the dielectric strength of the air and hence the rated operational voltage of the contactor. It also reduces the cooling effect of the air and hence the rated operational current of the contactor (unless the temperature drops at the same time). No derating is necessary up to 3000 m. Derating factors to be applied above this altitude for main pole operational voltage and current (AC supply) are as follows. Altitude 3500 m 4000 m 4500 m 5000 m Rated operational voltage 0.90 0.80 0.70 0.60 Rated operational current 0.92 0.90 0.88 0.86 The temperature of the air surrounding the device, measured near to the device. The operating characteristics are given: - with no restriction for temperatures between -5 and +55 C - with restrictions, if necessary, for temperatures between -50 and +70 C This is defined taking into account the rated operational voltage, operating rate and duty, utilization category and ambient temperature around the device. The current which a closed contactor can sustain for a minimum of 8 hours without its temperature rise exceeding the limits given in the standards. The current which a closed contactor can sustain for a short time after a period of no load, without dangerous overheating. This is the voltage value which, in conjunction with the rated operational current, determines the use of the contactor or starter, and on which the corresponding tests and the utilization category are based. For 3-phase circuits it is expressed as the voltage between phases. Apart from exceptional cases such as rotor short-circuiting, the rated operational voltage Ue is less than or equal to the rated insulation voltage Ui. The rated value of the control circuit voltage, on which the operating characteristics are based. For AC applications, the values are given for a near sinusoidal wave form (less than 5% total harmonic distortion). This is the voltage value used to define the insulation characteristics of a device and referred to in dielectric tests determining leakage paths and creepage distances. As the specifications are not identical for all standards, the rated value given for each of them is not necessarily the same. The peak value of a voltage surge which the device is able to withstand without breaking down. The rated power of the standard motor which can be switched by the contactor, at the stated operational voltage. This is the current value which the contactor can break in accordance with the breaking conditions specified in the IEC standard. This is the current value which the contactor can make in accordance with the making conditions specified in the IEC standard. This is the ratio between the time the current flows (t) and the duration of the cycle (T) m = t T Cycle duration: duration of current flow + time at zero current The impedance of one pole is the sum of the impedance of all the circuit components between the input terminal and the output terminal. The impedance comprises a resistive component (R) and an inductive component (X=Lω). The total impedance therefore depends on the frequency and is normally given for 50 Hz. This average value is given for the pole at its rated operational current. This is the average number of on-load operating cycles which the main pole contacts can perform without maintenance. The electrical durability depends on the utilization category, the rated operational current and the rated operational voltage. This is the average number of on-load operating cycles (i.e. with zero current flow through the main poles) which the contactor can perform without mechanical failure c Conventional thermal current, in free air, conforming to IEC standards. a For AC applications, the breaking and making capacities are expressed by the rms value of the symmetrical component of the short-circuit current. Taking into account the maximum asymmetry which may exist in the circuit, the contacts therefore have to withstand a peak asymmetrical current which may be twice the rms symmetrical component. NOTE: these definitions are extracted from standard IEC 947-1. t T 44 1998 Square D All Rights Reserved 5/98

5/98 1998 Square D All Rights Reserved 45

46 1998 Square D All Rights Reserved 5/98

5/98 1998 Square D All Rights Reserved 47

is a registered trademarks of Canadian Standards Association. Square D Company 8001 Hwy. 64 East Knightdale, NC 27545 (919) 266-3671 and are registered trademarks of Underwriters Laboratories Inc. Square D and are registered trademarks of Square D Company. Catalog No. 8502CT9703 May 1998 1998 Square D All Rights Reserved.