TeSys IEC Contactors and Overload Relays

Similar documents
TeSys protection components

3 Pole Contactors with AC operating coils

TeSys contactors From 115 to 2750 A

Motor protection relays

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1B004TLH cam switch - 1 pole A - screw mounting

K-Line Mini - Contactors, Overload Relays and Accessories

K1D012ULH cam changeover switch - 2-pole A - screw mounting

RM4TR31 three-phase network control relay RM4-T - range V

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

1492-SP Supplementary Protectors

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1F006ALH cam switch - 6-pole A - screw mounting

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

Square D General Purpose Relays

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

Mini Contactors & Overloads

ZB5FG09 flush mounted selector switch head key pos stay put

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

RM4TA32 three-phase network control relay RM4-T - range V

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

Circuit Breakers Type CTI 25M, CTI 45MB

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Zelio Control-modular measurement and control relays 1

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

RM4JA01F current measurement relay RM4-J - range ma V AC

XCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

RM4JA31M current measurement relay RM4-J - range ma V AC

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Bulletin 817 Thermistor Protection Relay

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

Supplementary Circuit Protectors Type GSB63

OsiSwitch Limit Switches Innovation through modularity

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

WMS SUPPLEMENTARY PROTECTORS

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

UL 489 DIN Rail Miniature Circuit Breakers

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

WEG Contactors - CWM and CWME Series

RM4UA33M voltage measurement relay RM4-U - range V V AC

XCKP2110G11 limit switch XCKP - metal end plunger - 1NC+1NO - snap - Pg11

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

UL 489 DIN Rail Miniature Circuit Breakers

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE9RA21MW7 off-delay timing relay s V AC -

RM35LM33MW liquid level control relay RM35-L V AC/DC

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

RM35TF V AC

XB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center

RXM4AB3BD Miniature Plug-in relay - Zelio RXM 4 C/O 24 V DC 6 A with LED

RXM4AB1MD Miniature Plug-in relay - Zelio RXM 4 C/O 220 V DC 6 A

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Transcription:

TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the market leader in quality, durability, and product development. The latest development in the TeSys family of IEC contactors and overload relays is component high-fault short-circuit current ratings (SCCRs). TeSys K and D Contactors SCCRs identify the level of fault current that a component or assembly can safely withstand. Without knowing the available fault current and SCCR, it is impossible to determine if components or equipment can be safely installed. The new high-fault component SCCRs are available for all TeSys K and D contactors and overload relays, including the TeSys D solid-state overload relays. Component ratings provide the flexibility to choose the desired level of protection, up to the rated maximum, and use it without the need for specific tested combinations and confusing tested combination spreadsheets. Component ratings are available when using either fuse or circuit breaker protection. TeSys High-Fault Component Short-Circuit Current Ratings: TeSys K and D Overload Relays 65 ka on any system up to 80 Vac and amps protected by a circuit breaker 00 ka on any system up to 80 Vac and greater than amps protected by a circuit breaker 00 ka on any system up to 600 Vac protected by Class CC or J fuses And the best part about component ratings? You know you have the right SCCR when you see it on the label! Make the most of your energy SM

TeSys D Overload Relays Current Setting Range (A) 0.0 0.6 For Direct Mounting to LC Class 0 with Class 0 without Class 0 with Class 0 without Maximum Component SCCR (ka) [] Circuit Breakers @ 80 V [] Max. SCCR (ka) 0 0 65 00 0.6 0.5 0 0 65 00 0.5 0.0 0 0 65 00 0.0 0.6 0 0 65 00 0.6 05 05 65 00.6 D09 D 06 06 65 00.6.5 07 07 65 00.5 08 08 508 508A 65 00 6 0 0 50 50A 65 00 5.5 8 5 5A 65 00 7 0 5 5A 65 00 9 D D 6 6 56 56A 65 00 8 D8 D 5 5A 65 00 6 65 00 7 5 5 5A 65 00 D5 D 65 00 8 50 50A 65 00 5 5 5A 65 00 0 8 D 5 5 65 00 9 L 00 00 8 8 8 8L 00 00 6 5 5 5 5L 00 00 D0A D65A [] L 00 00 0 0 0 0 0L 00 00 7 50 50 50 50L 00 00 8 65 D50A D65A [] 65 65 65L 00 00 7 5 5 5 00 00 D0 D80 [5] 5 5 55 55 00 00 0 0 55 55 555 555 00 00 7 50 57 57 557 557 00 00 8 65 D50 D80 [5] 59 59 559 559 00 00 55 70 6 6 56 56 00 00 6 80 D65 D80 [5] 6 6 56 56 00 00 80 0 D80 65 00 00 80 0 65 00 00 D5 D50 95 0 67 00 00 Fuses @ 600 V [] Max. SCCR (ka) [] Ratings apply to circuits with voltages no greater than those listed and are subject to maximum breaker and fuse ampacities. See data bulletin 856DB090 for ampacity limitations. [] When protected by any circuit breaker, including thermal-magnetic and magnetic-only. [] When protected by any Class J or CC time-delay fuse (Class CC applicable up to 0 A only). [] Overload relays with Everlink termination direct mount to D0A to D65A only. [5] Direct mount to old D style D0 to D65 (no Everlink terminations) and to D80 only. Note: This table lists the maximum SCCR of the component when protected by any circuit breaker or fuse. If the maximum component SCCR is 00 ka and a 5 ka rated circuit breaker is used, then the system will be 5 ka as the circuit breaker becomes the weakest link.

LR and -pole Bimetallic Overload Relays LR and -pole Bimetallic Overload Relays Description D-Line -pole thermal overload relays are designed to protect ac circuits and motors against overloads, phase failure, long starting times and prolonged stalling of the motor. 0 to 5 to 69, 5.5 0 RESET STOP 6 5 6 7 TEST 6 50 A M R A E S E T 5 7 NO NC 98 97 95 96 Environment Adjustment dial Ir Test button Operation of the Test button allows: - checking of control circuit wiring, - simulation of relay tripping (actuates both the N.O. and N.C. contacts). Stop button. Actuates the N.C. contact; does not affect the N.O. contact. Reset button 5 Trip indicator 6 Setting locked by sealing the cover. 7 Selector for manual or automatic reset. Relays 0 to 5 are supplied with the selector in the manual position, protected by a cover. Deliberate action is required to move it to the automatic position. Conforming to standards IEC 6097-, IEC 6097--, NF C 6-650, VDE 0660, BS 9 Product certifications CSA, UL, Sichere Trennung, PTB except LAD: UL, CSA. Degree of protection Conforming to VDE 006 Protection against direct finger contact IP X Protective treatment Conforming to IEC 60068 TH Storage C - 60 to + 70 (- 0 to + 58 F) Ambient air temperature around the device Normal operation, without derating (IEC 6097--) C - 0 to + 60 (- 68 to + 0 F) Minimum and maximum operating temperatures (with derating) C - 0 to + 70 (- 0 to + 58 F) Operating positions without derating In relation to normal, vertical mounting plane Any position Shock resistance Permissible acceleration conforming to IEC 60068--7 5 gn - ms Vibration resistance Permissible acceleration conforming to IEC 60068--6 6 gn Dielectric strength at 50 Hz Conforming to IEC 6055-5 kv 6 Impulse withstand voltage Conforming to IEC 6080-5 kv 6 Auxiliary Contact Characteristics Conventional rated thermal current A 5 Amps AC; Amp DC Maximum consumption of operating coils of controlled contactors (Occasional operating cycles of contact 95-96) ac supply V 8 0 0 80 600 VA 00 00 00 600 600 600 dc supply V 8 0 0 0 W 00 00 50 5 5 Short-circuit protection k By gg, BS or Class CC fuse. Max. rating or by GB circuit-breaker A 5 maximum Connection to screw clamp terminals Flexible cable with cable end One or two conductors AWG (mm ) 8 - ( -.5) Solid cable without cable end One or two conductors AWG (mm ) 8 - ( -.5) Flexible cable without cable end One or two conductors AWG (mm ) 8 - ( -.5) Solid cable without cable end One or two conductors AWG (mm ) 8 - ( -.5) Tightening torque lb-in (N.m) 5 (.7) k Select short circuit protection to meet the National Electrical Code or other local codes and standards. Catalog Numbers: pages, 5 Dimensions: pages 8-0 0 00-00 Schneider Electric All Rights Reserved 0/0

LR and -pole Bimetallic Overload Relays Electrical Characteristics of Power Circuit Relay type 0 to 6 LR D0 to D6 LR D5 to 5 LR D to D5 LR D5 to 696 LR D to D696 Tripping class To UL 508, IEC 6097-- 0 0 0 0 0 0 0 Rated insulation voltage (Ui) Conforming to IEC 6097-- Conforming to UL, CSA V 600 600 600 LR D5 V 690 690 000 000 65 to 69 600 except 69 Rated impulse withstand voltage (Uimp) kv 6 6 6 6 Frequency limits Of the operational current Hz 0 to 00 0 to 00 0 to 00 0 to 00 Setting range Depending on model A 0. to to 8 7 to 0 80 to 0 Connection to screw clamp terminals Flexible cable without cable end One conductor AWG (mm ) - 8 (.5-0) - 8 (.5-0) Flexible cable with cable end One conductor AWG (mm ) 6 - ( - ) Solid cable without cable end One conductor AWG (mm ) 6-0 ( - 6) 6-0 ( - 6) except : 6 - ( - ) - 8 (.5-0) except : 6-0 ( - 6) 0 - ( - 5) 0 - ( - 5) - ( - 5) Tightening torque lb-in (N.m) 5.0 (.7) 6. (.85). (.5) 00 lb-in 00 lb-in Connection to spring terminals Flexible cable without cable end One conductor AWG (mm ) - (.5 - ) - (.5 - ) Solid cable without cable end One conductor AWG (mm ) - (.5 - ) - (.5 - ) Operating Characteristics Temperature compensation C F - 0 to + 60-68 to + 0-0 to + 60-86 to + 0 Tripping threshold Conforming to IEC 6097-- A. ± 0.06 In to phase failure Conforming to IEC 6097-- Tripping current 0% of In on one phase, the others at In Tripping curves Average operating time related to multiples of the current setting Class 0-0 to + 60-86 to + 0 Class 0 0 - ( - 50) 0 - ( - 5) 0 - ( - 50) - 0 to + 60-68 to + 0 Hours Hours 0 0 0 0 Minutes 0 Minutes 0 0 0 0 0 Seconds 0 0.8 0.8 6 0 7 0 Seconds 0 0.8 0.8 6 0 7 0 x times current setting (Ir) x times current setting (Ir) Balanced operation, -phase, from cold state. Balanced operation, -phase, from cold state. Balanced operation, -phase, after a long period at the set current (hot state). Catalog Numbers: pages, 5 Dimensions: pages 8-0 0/0 00-00 Schneider Electric All Rights Reserved

Selection of -pole Class 0 Bimetallic Overload Relays Selection of -pole Class 0 Bimetallic Overload Relays 08 08 Differential (Single Phase Sensitive) Thermal Overload Relays Compensated Relays with Manual or Automatic Reset, with Relay Trip Indicator, for ac or dc. Short-circuit Protection for North American Applications By Circuit Breaker By Fuses Select in Accordance with NEC and Local Codes Maximum 00% of Motor FLA Relay Setting Range Fuses to be used with Selected Relay For use with am gg BS88 Contactor LC- Catalog Number Weight lb. (kg) A A A A Class 0 with Connection by Screw Clamp Terminals 0.0 to 0.6 0.5 D09 to D8 () 0 0.7 (0.) 0.6 to 0.5 0.5 D09 to D8 () 0 0.7 (0.) 0.5 to 0.0 D09 to D8 () 0 0.7 (0.) 0.0 to 0.6 D09 to D8 () 0 0.7 (0.) 0.6 to D09 to D8 () 05 0.7 (0.) to.6 6 D09 to D8 () 06 0.7 (0.).6 to.5 6 0 D09 to D8 () 07 0.7 (0.).5 to 6 0 6 D09 to D8 () 08 0.7 (0.) to 6 8 6 6 D09 to D8 () 0 0.7 (0.) 5.5 to 8 0 0 D09 to D8 () 0.7 (0.) 7 to 0 0 0 D09 to D8 () 0.7 (0.) 9 to 6 5 5 D to D8 () 6 0.7 (0.) to 8 0 5 D8 to D8 () 0.7 (0.) 6 to 5 50 50 D5 to D8 () 0.7 (0.) to 0 6 6 D5 to D8 () 0.7 (0.) 0 to 8 50 80 80 D and D8 () 5 0.7 (0.) 7 to 5 5 50 50 D0 to D95. (0.50) to 0 6 6 D0 to D95 5. (0.50) 0 to 0 0 00 80 D0 to D95 55. (0.50) 7 to 50 6 00 00 D0 to D95 57. (0.50) 8 to 65 6 00 00 D50 to D95 59. (0.50) 55 to 70 80 5 5 D50 to D95 6. (0.50) 6 to 80 80 5 5 D65 to D95 6. (0.50) 80 to 0 00 60 60 D80 and D95 65. (0.50) 80 to 0 5 00 60 D5 and D50 65.98 (0.900) 95 to 0 5 00 00 D5 and D50 67.98 (0.900) 0 to 0 60 50 00 D50 69.98 (0.900) 80 to 0 00 60 60 D5 and D50 656 ().0 (.000) 95 to 0 5 00 00 D5 and D50 676 ().0 (.000) 0 to 0 60 50 00 D5 and D50 696 ().0 (.000) Class 0 with Spring Terminal Connections (for direct mounting on the contactor only) 0.0 to 0.6 0.5 D09 to D8 () 0 6. (0.0) 0.6 to 0.5 0.5 D09 to D8 () 0 6. (0.0) 0.5 to 0.0 D09 to D8 () 0 6. (0.0) 0.0 to 0.6 D09 to D8 () 0 6. (0.0) 0.6 to D09 to D8 () 05 6. (0.0) to.6 6 D09 to D8 () 06 6. (0.0).6 to.5 6 0 D09 to D8 () 07 6. (0.0).5 to 6 0 6 D09 to D8 () 08 6. (0.0) to 6 8 6 6 D09 to D8 () 0 6. (0.0) 5.5 to 8 0 0 D09 to D8 () 6. (0.0) 7 to 0 0 0 D09 to D8 () 6. (0.0) 9 to 6 5 5 D to D8 () 6 6. (0.0) to 8 0 5 D8 to D8 () 6. (0.0) 6 to 5 50 50 D5 to D8 () 6. (0.0) Class 0 with Ring-Tongue Terminals for 0 through 5 (load side terminals only) Select the appropriate overload relay with screw clamp terminals from the table above and add 6 to the end of the reference. Example: 0 becomes 06. Thermal Overload Relays for use on single phase loads Class 0 with connection by screw clamp terminals Change the prefix in the references above from (except kkk) to. Example: 0 becomes 0. Thermal Overload Relays for use on 000 V Supplies Class 0 with connection by screw clamp terminals For relays -0 to -5 only, for an operating voltage of 000 V, and only for independent mounting, the reference becomes A66. Example: becomes A66. Order an LA7D06 terminal block separately; see page 7. () These are special separate mounted versions of the overload relays for the LCD5 and D50 contactors. Part number includes overload relay, terminal block and 6 connectors (unit is not UL/CSA approved). () When used with D5-D8 contactors, order spacer clip (part number W866680). See page 7. 00-00 Schneider Electric All Rights Reserved 0/0