Motor Control Products Selection Guide

Similar documents
CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers Type CTI 25M, CTI 45MB

Data sheet. CI-TI TM Contactors and Motor Starters Timers ATI, BTI, MTI 520B1307

Electronic time relays ATI, BTI, SDT and MTI

IEC Power Control Contactors and Contactor Assemblies

Contactors and Contactor Assemblies

MOTOR PROTECTION CIRCUIT BREAKERS

0 1 CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA-20 27

onlinecomponents.com

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Micro Contactor MA Series

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Series CA7 Contactors

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

CS7 Industrial Control Relays

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Motor protection circuit breakers

Controls Enclosed Non-Combination Starters - PESW Series

78 Series Electromechanical Relay Selection Guide

sirius Switching. Protecting. Starting. SIRIUS Product Overview

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

3 Pole Contactors with AC operating coils

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

Jtec 10kA Miniature Circuit Breaker

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

K-Line Mini - Contactors, Overload Relays and Accessories

CI-tronic Reversing contactor Type RCI

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Experiment #2 PLC Input Output Wiring Methods. OBJECTIVES After successfully completing this laboratory, you should be able to:

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

Series CA7 Contactors

Mini Contactors & Overloads

Redline. Extensions. Display contacts. Function S. Display contact CA. Function. Add-on Devices T3.2

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

pointofsale available at your local trade outlet

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

Series CA9 Contactors

Contactors and Contactor Assemblies

MOTOR & CIRCUIT PROTECTION

Electrical Demand Specification (Reference SOP: )

Contactors and Contactor Assemblies

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

3RA13, 3RA14 Contactor Assemblies

EU Declaration of Conformity

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

TeSys IEC Contactors and Overload Relays

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

3RT, 3TB, 3TF Contactors for Switching Motors

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...

Allen-Bradley Bulletin 100 Contactors

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

3RV1 Circuit-Breakers

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

CS8 Industrial Control Relays

Magnetically Actuated Safety Interlock Switches

Manual Motor Protectors

IEC Contactors. Auxiliary Contact Blocks GENERAL

Large Frame IEC Contactors

RW-E. Overloads. Solid-State Overload Relays. Standard Features

WMS SUPPLEMENTARY PROTECTORS

SACE Emax 2 Specification guide

EU Declaration of Conformity

UL 489 DIN Rail Miniature Circuit Breakers

194E FA 32 E P11 P11 6

Motor protection circuit breakers

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

60103 Circuit Breaker

CS7 Industrial Control Relays

XT IEC Power Control Contactors, Starters and Overload Relays

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

TeSys protection components

Magnetically Actuated Safety Interlock Switches

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320

RSTI-EP Slice I/O. Digital Output Module

Go to:

UL 489 DIN Rail Miniature Circuit Breakers

Safety Systems Safety Integrated

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Description. Installation. Power supply

Exercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

C 2 5 D N A A A

References. References. Rating (A) Référence

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Switching module for AC V and up to three load stages, with manual switching

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Table of Specifications

Automation Products. Pilot devices The complete range

CI-tronic Soft start motor controller

02/11/2015

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Transcription:

MKING MODERN LIVING POSSIBLE Motor Control Products Selection Guide Contactors, Relays, and Circuit Breakers www.danfoss.com/ia

c o n t e n t s Minicontactors CI 5 Thermal Overload Relays TI 9C for Minicontactors IEC Contactors CI 6-CI 420EI with C Coils IEC Contactors CI 9-C I30EI with DC Coils Thermal Overload Relays TI 16C - TI 630E for IEC Contactors ccessories for Contactors TI 16C - TI 630E for IEC Contactors Electronic Clip-On Timers ETB DIN Rail Mounting Timers TI, BTI Circuit Breakers & ccessories CTI 15- CTI 100 Pages 2-4 Pages 4-5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Pages 12-14

Minicontactor CI 5 CI 5 minicontactors cover the power range up to 7.5 HP and are available for C and DC coil voltages enabling reliable working with extremely low and high voltage fluctuations. Compact design The compact design of the CI5 minicontactor makes it suitable for applications where space is at a premium. High flexibiity With add-on auxiliary contact blocks, timers and other additional accessories they offer high flexibility. Safety & Protection The CI 5-series guarantees extra safety against electric shock by protective distance for live parts during mounting according to IEC 60947 edition 5 standard. The CI 5-series also includes dedicated bimetallic overload protection relays for sensitive to phase-loss condition. In addition, the CI 5-series also includes thermal overload relays for the protection of squirrel-cage motors.. Danfoss Coil Voltages Type Poles 01 12VDC 02 24VDC 13 24V50/60Hz 23 110V50/100-120V60Hz 32 230V50/60Hz 33 240V50/60Hz 37 400V50/60Hz Type Poles ux# 115/1 230/1 220-230/3 460-575/3 CI5-5 3 1NO 0.5HP 1HP 1.5HP 3HP CI5-5 3 1NC 0.5HP 1HP 1.5HP 3HP CI5-9 3 1NO 0.75HP 1.5HP 3HP 5HP CI5-9 3 1NC 0.75HP 1.5HP 3HP 5HP CI5-9 4 0.75HP 1.5HP 3HP 5HP CI5-12 3 1NO 0.75HP 1.5HP 3HP 5HP CI5-12 3 1NC 0.75HP 1.5HP 3HP 5HP 2

CI 5 Minicontactors Discontinued Type HP Voltage Hz CI 4 Code Number CI 5 Code number CI 5 10 3.0 24V 50/60Hz 037H311413 037H350213 CI 5 10 3.0 110-120V 50/60Hz 037H311423 037H350223 CI 5 10 3.0 230V 50/60Hz 037H311432 037H350232 CI 5 10 3.0 240V 50/60Hz 037H311433 037H350233 CI 5 10 3.0 400V 50/60Hz 037H311437 037H350237 CI 5-5 01 3.0 24V 50/60Hz 037H311513 037H350313 CI 5-5 01 3.0 230V 50/60Hz 037H311532 037H350332 CI 5-5 01 3.0 240V 50/60Hz 037H311533 037H350333 CI 5-9 10 5.0 24V 50/60Hz 037H311613 037H350413 CI 5-9 10 5.0 110-120V 50/60Hz 037H311623 037H350423 CI 5-9 10 5.0 230V 50/60Hz 037H311632 037H350432 CI 5-9 10 5.0 240V 50/60Hz 037H311633 037H350433 CI 5-9 10 5.0 400V 50/60Hz 037H311637 037H350437 CI 5-9 01 5.0 24V 50/60Hz 037H311713 037H350513 CI 5-9 01 5.0 110-120V 50/60Hz 037H311723 037H350523 CI 5-9 01 5.0 230V 50/60Hz 037H311732 037H350532 CI 5-9 01 5.0 240V 50/60Hz 037H311733 037H350533 CI 5-9 M40 5.0 230V 50/60Hz 037H311832 037H350632 CI 5-9 M40 5.0 240V 50/60Hz 037H311833 037H350633 CI 5-9 M40 5.0 24V 50/60Hz 037H311813 037H350613 CI 5-12 10 7.5 24V 50/60Hz 037H345713 037H350713 CI 5-12 10 7.5 110-120V 50/60Hz 037H345723 037H350723 CI 5-12 10 7.5 230V 50/60Hz 037H345732 037H350732 CI 5-12 10 7.5 240V 50/60Hz 037H345733 037H350733 CI 5-12 01 7.5 24V 50/60Hz 037H345813 037H350813 CI 5-12 01 7.5 240V 50/60Hz 037H345833 037H350833 CI 5-5 10 7.5 24V DC 037H314302 037H350202 CI 5-5 01 7.5 24VDC 037H314402 037H350302 CI 5-5 10 3.0 12VDC 037H314501 037H350401 CI 5-9 10 3.0 24VDC 037H314502 037H350402 CI 5-9 01 3.0 24VDC 037H314602 037H350502 CI 5-12 10 7.5 24VDC 037H345902 037H350702 CI 5-12 01 7.5 24VDC 037H346002 037H350802 CI 5-12 10 7.5 230V 50/60Hz 037H445732 037H450732 CI 5-2 40E Control Relay 230V 50/60Hz 037H321032 037H350032 CI 5-2 22Z Control Relay 24V 50/60Hz 037H321113 037H350113 CI 5-2 22Z Control Relay 230V 50/60Hz 037H321132 037H350132 CI 5-2 40E Control Relay 24VDC 037H321202 037H350002 CI 5-2 22Z Control Relay 24VDC 037H321302 037H350102 Note: Discontinued CI 4 parts cannot be matched with CI 5 replacements 3

ccessories for Minicontactors Type Description Discontinued CI 4 Code number CI 5 Code number DCN 250 Diode element, CI5 037H3148 037H351000 RCN 48 RC element, 24...48VC, CI5 037H3155 037H351800 RCN 280 RC element, 110...280VC, CI5 037H3156 037H351900 INT 5 Mechanical Interlock, CI5 037H3157 037H352000 uxiliary contact blocks for Minicontactors Type Description Discontinued CI 4 Code number CI 5 Code number CBN 40 ux. Contact 3NO, CI5 037H3149 037H351100 CBN 22 ux. Contact 2NO+2NC, CI5 037H3152 037H351500 CBN 04 ux. Contact 4NC, CI5 037H3369 037H351200 CBN 11 ux. Contact 1NO+1NC, CI5 037H3151 037H351400 CBN 02 ux. Contact 2NC, CI5 037H3150 037H351300 Thermal Overload Relays TI 9C Thermal overload relay TI 9C-5 is used with minicontactor CI 5 for protection of squirrel cage motors where compactness is required. The relays have single phase protection, i.e. accelerated release if phase drop-out occurs. This is particularly important for motors with delta connected windings. Stop/reset button Manual/automatic reset Test button Double scale for direct start or Y/D start Galvanically isolated signal contact 4

Thermal Overload Relays TI 9C for CI 5Minicontactors Type Current DOL motor starter () Current star-delta starter () Discontinued TI 9 Code Number TI 9C-5 Code number TI 9C-5 0.27-0.42 047H306200 047H313200 TI 9C-5 0.40-0.62 047H306300 047H313300 TI 9C-5 0.60-0.92 047H306400 047H313400 TI 9C-5 0.85-1.30 047H306500 047H313500 TI 9C-5 1.20-1.90 047H306600 047H313600 TI 9C-5 1.80-2.80 3.2-4.8 047H306700 047H313700 TI 9C-5 2.70-4.20 4.7-7.3 047H306800 047H313800 TI 9C-5 4.00-6.20 6.9-10.7 047H306900 047H313900 TI 9C-5 6.00-9.20 10.0-16.0 047H307000 047H314000 TI 9C-5 8.00-12.00 047H307100 047H314100 Range Max Fuse 1) HRC 2) Motor Starter Y/D Starter gl, gl, gg BS 88, type T Form II Type 1 Type 2 0.13-0.20-25 - 32-1 0.19-0.29-25 - 32 2 1 0.27-0.42-25 2 32 2 1 0.4-0.62-25 2 32 4 1 0.6-0.92-25 4 32 6 3 0.85-1.3-25 4 32 6 3 1.2-1.9-25 6 32 10 6 1.8-2.8 3.2-4.8 25 6 32 10 15 2.7-4.2 4.7-7.3 25 16 32 20 15 4.0-6.2 6.9-10.7 35 20 40 25 15 6.0-9.2 10-16 50 20 50 25 35 8.0-12 13-20.8 63 25 63 32 35 1) To IEC 947-4 coordination types 1 and 2: Coordination type 1: ny type of damage to the motor starter is permissible. If the motor starter is in an enclosure, no external damage to the enclosure is permissible. fter a short-circuit the thermal overload relay shall be partially or wholly replaced. Coordination type 2: No damage to the motor starter is permissible, but slight contact burning and welding is permissible. 2) In accordance with HRC form II, TI 9C and 12C is suitable for operation in Canada and the US. Selection of thermal overload relay The selection of a thermal overload relay must be based on the motor full load current and the method of starting: With direct start the range for motor starter is used. With star-delta start the range for Y/D starter is used. Example using CI-9 contactor: Full load current: 12 (Code states to size for 115% of FL, meaning to use 12 x 1.15 = 13.8) With direct start, the suitable motor starter range is 11-16, i.e. thermal overload relay 047H021200. 5

CI 6-420EI Contactors with C Coils 6 IEC Contactors CI 6-CI 420EI with C Coils The CI 6-420 contactor program includes multiple frame sized contactors from 0.5 to 400HP Compact design in multiple sizes The compact frame design of the CI contactors makes them ideal to fitting into almost any space. Power Range from 0.5 to 400HP With a wide power range, there is a CI contactor to fit the needs of OEMs and Panel Builders High reliability long electrical liftetime makes these contactors suitable for all kinds of electrical loads in modern industry. Combined with a thermal overload relay, the contactor switches and protects induction motors against overload and asymmetric load. Type 115/1 230/1 208/3 230/3 460/3 575/3 3 Pole 4 Pole CI 6 0.5HP 1HP 1.5HP 2HP 3HP 5HP 037H0015** CI 9 0.5HP 1.5HP 2HP 3HP 5HP 7.5HP 037H0021** 037H0022** CI 12 0.75HP 2HP 3HP 7.5HP 10HP 037H0031** 037H0032** CI 15 1HP 3HP 3HP 5HP 10HP 10HP 037H0049** 037H0050** CI 16 1HP 3HP 5HP 5HP 10HP 15HP 037H0041** CI 25 2HP 5HP 7.5HP 15HP 20HP 037H0051** CI 30 2HP 5HP 7.5HP 10HP 15HP 20HP 037H0055** CI 32 2HP 5HP 7.5HP 10HP 20HP 25HP 037H0061** CI 37 3HP 7.5HP 10HP 15HP 25HP 30HP 037H0056** CI 45 3HP 7.5HP 10HP 15HP 30HP 30HP 037H0071** CI 50 10HP 15HP 15HP 30HP 40HP 037H0080** CI 61 5HP 10HP 15HP 20HP 40HP 50HP 037H3061** CI 73 7.5HP 15HP 20HP 25HP 50HP 60HP 037H3062** CI 86 10HP 15HP 25HP 30HP 60HP 60HP 037H3063** CI 141 60HP 100HP 100HP 037H3339** CI 180 75HP 120HP 120HP 037H3082** CI 210EI 50HP 60HP 75HP 150HP 200HP 037H3259** CI 250EI 75HP 100HP 200HP 250HP 037H3267** CI 300EI 100HP 125HP 250HP 300HP 037H3269** NOTE: Some contactors may not be available in all voltages. CI 6-420EI Suffix Codes Coil Voltage CI 6-50 CI 61, 73, 86 CI 141,180 CI 210-420EI 24V, 50/60Hz 13 13 48V, 50/60Hz 92V, 50Hz/110V, 60Hz 110V,50/60Hz 23 23 22 23 208-230V, 60Hz 28 210V, 50Hz/240V, 60Hz 32 220-230V, 50Hz/220V,60Hz 32 32 31 380-400V, 50Hz/440V, 60Hz 37 37 380-500V/50-60Hz 94 39

IEC Contactors CI 9-30 with DC Coils Contactors CI 9 DC - CI 30 DC (no built-in auxiliary contacts) - ref. Figure 1 Contactors CI 9 DC - 30 DC and 9 EI - 30 EI cover the range up to 20HP at 600 VC. The operation of the coil is controlled by an electronic circuit while the control voltage is 12 V DC or 24 V DC. The CI 9 EI - 30 EI range also includes thermal overload relays for protection of squirrel-cage motors. Compact design in multiple sizes The compact frame design of the CI contactors makes them ideal to fitting into almost any space. Integrated interface relay The range CI 9 EI - 30 EI has a built-in interface relay for PLC application with 24 V d.c. output. Flexibility wide range of clip-on aux. contacts, timers, surge suppressors, mechanical interlock and marking plates makes the CI 9-30 program very flexible and suitable both for OEMs and panel builders. Main Circuit Control Circuit C-3 Load Coil Type Maximum Horsepower Code Number 1-2 1 Phase 3 Phase V 115V 230V 200V 230V 460V 575V CI 9 DC 0.5 1.5 2 3 5 7.5 24 V d.c. 037H807166 CI 15 DC 1 3 3 5 10 15 12 V d.c. 037H800366 CI 15 DC 1 3 3 5 10 15 24 V d.c. 037H807366 CI 25 DC 2 4 5 7.5 15 20 24 V d.c. 037H807666 CI 30 DC 2 5 7.5 7.5 15 20 24 V d.c. 037H807766 Interface contactors CI 9 EI - CI 30 EI (no built-in auxiliary contacts) - ref. Figure 2 Main Circuit Control Circuit C-3 Load Coil PLC Type Maximum Horsepower 1-2 B+ - B- 1 Phase 3 Phase V V 115V 230V 200V 230V 460V 575V CI 9 EI 0.5 1.5 2 3 5 7.5 24 V d.c. Code Number 037H801166 CI 9 EI 0.5 1.5 2 3 5 7.5 220-240 V a.c.3) 037H806166 CI 15 EI 1 3 3 5 10 15 24 V d.c. 037H801366 CI 15 EI 1 3 3 5 10 15 220-240 V a.c.3) 037H806366 24 V d.c. CI 25 EI 2 4 5 7.5 15 20 24 V d.c. 037H801666 CI 25 EI 2 4 5 7.5 15 20 220-240 V a.c.3) 037H806666 CI 30 EI 2 5 7.5 7.5 15 20 24 V d.c. 037H801766 CI 30 EI 2 5 7.5 7.5 15 20 220-240 V a.c.3) 037H806766 1) The thermal current value Ith gives the maximum load at 40 C, which corresponds to installing the contactor in air (open). 2) The thermal current value Ithe gives the maximum load at 60 C, corresponding to installing the contactor inside an enclosure. 3) Coils are dual frequency coils. 7

Thermal Overload Relays For IEC Contactors Thermal Overload Relays Range, Type Use with Contactor Code Number 0.13-0.20 1.2-1.9 TI 16C 047H020600 1.8-2.8 047H020700 CI 6 to CI 30 2.7-4.2 047H020800 8 047H020000 0.19-0.29 047H020100 0.27-0.42 047H020200 0.40-0.62 047H020300 0.60-0.92 047H020400 0.85-1.30 047H020500 4-6.2 047H020900 6-9.2 047H021000 8-12 047H021100 11-16 047H021200 15-20 047H021300 TI 25C 19-25 047H021400 24-32 TI 30C 047H021500 16-23 047H101300 22-32 CI 32 to CI 50 047H101400 30-45 TI 80* 047H101500 42-63 047H101600 60-80 CI 32 to CI 86 047H101700 74-85 TI 86* 047H101800 Electronic Overload Relays with Manual Reset Type Range Control Voltage Use with Contactor Code Number TI 180 E** 20-180 TI 630 E 160-630 110V, 50/60Hz 047H301400 220-230V, 50/60Hz 047H301500 CI 141-180 240V, 50/60Hz 047H301600 380-400V, 50/60hz 110V, 50/60Hz 220-230V, 50/60Hz CI 210 EI to 420 EI *Use Connectors 037H010866 to connect TI 80, TI 86 to contactors **Use Connectors 047H3027 to connect TI 180E to CI 110 / Use Connectors 047H3028 to conect TI 180E to CI 180 ccessories for Electronic Overload Relays 047H301700 047H303200 047H303300 Type Control Voltage Use with Relay Code Number IMR Remote Indicator TI 180 E, TI 630 E 047H3023

uxiliary contact blocks CB for CI 6-50, CI 9EI-30EI, and CI 9DC-30DC contactors Contact Function 1) e m Load Contact Function uxiliary contact blocks CBD for CI 61, 73, 86 contactors U e V e (C-15) Contact Function 1) th 1) (C-1) Open Color code Type Code Number Make 1-30 5-30 white CB-NO 037H012100 Break 1-30 5-30 blue CB-NC 037H012200 e (C-15) 9 Load the 2) (C-1) Encl. th 2) (C-1) Open Load the 3) (C-1) Encl. U e V Type Code Number 1 make (NO) + 1 break (NC) 5.5 10 6 690 CBD-11 037H306400 1 break (NC) 3 10 6 690 CBD S-NC 037H306600 1 make (NO) 3 10 6 690 CBD S-NO 037H306700 1 make (NO) + 1 break (NC) 3 10 6 690 CBD S-11 037H306900 2 make (NO) 3 10 6 690 CBD S-20 037H307000 1) Force-actuated contacts suitable for safety switching. 2) The thermal current th gives the maximum load at 40 C, which corresponds to installing the contactor in air (open) 3) The thermal current the gives the maximum load at 60 C, which corresponds to installing the contactor in an enclosure In CBD auxiliary contact the silver tips are cross-stamped. In CBD S auxiliary contact the silver tips are H-shaped. Both contact types are PLC-compatible. Min. load 24 V, 10 m U e V Color code Type Code Number Start 6 10 10 500 green CB-S 037H011000 Start pulse 6 10 10 500 green CB-I 037H011700 Make 6 10 10 500 green CB-NO 037H011100 Break 6 10 10 500 red CB-NC 037H011200 Early make 6 10 10 500 white CB-EM 037H011300 Late break 6 10 10 500 blue CB-LB 037H011400 1) The thermal current value th gives the maximum load at 40 C, which corresponds to installing the contactor in air (open) 2) The thermal current the gives the maximum load at 60 C, which corresponds to installing the contactor in an enclosure uxiliary contact blocks CB with gold plated contacts for CI 6-50, CI 9EI-30EI, and CI 9DC-30DC contactors (PLC compatible) CB auxiliary contact blocks are force-actuated when mounted on CI 6-50 and can therefore form part of safety switching. In the standard auxiliary contact CB - the silver tips on moveable contact is cross stamped and PLCcompatible. Min. load 24 V, 10m. ccessories for contactors CI 6-50, CI 9EI-30EI, and CI 9DC-30DC contactors Description Function Code number Mech. interlock for CI 6-30, Mech. interlock can be established between pairs (1-off ) 037H009166 CI 9DC-30DC, CI 9EI-30EI Mech. interlock for CI 32-50 Mech. interlock can be established 037H010666 RC Element for CI 6-30 Reduces overvoltage on de-energization of coils 037H007500 Type RC 48 (24-48V, 50/60 Hz) Type RC 250 (110-250V, 50/60 Hz) Type RC 415 (380-415V, 50/60 Hz) 037H007600 037H007700 Rating plate for CI 6-50 Rating plate can be mounted in auxiliary contact space (10-off ) 037H010166

Electronic Clip-on Timers ETB ETB electronic clip-on timers are for use with Danfoss contactors to delay contactor close and open. The clip-on timers can be clipped direct onto contactors CI 6-50 and occupy as little space as one auxiliary contact. Where separate mounting at the side of contactors is required, a DIN rail mounting base is available. ON-delay clip-on timers for a.c. control voltage 50/60 Hz Time Range Voltage Range V Type Code Number 0.5-20 s 24-65 047H017000 4-160 s 24-65 047H017100 0.5-20 s 110-240 ETB 047H017300 4-160 s 110-240 047H017400 0.5-20 min 110-240 047H017500 OFF-delay clip-on timers for a.c. control voltage 50/60 Hz Time Range Voltage Range V Type Code Number 0.5-20 s 24-65 047H018000 4-160 s 24-65 047H018100 0.5-20 min 24-65 047H018200 ETB 0.5-20 s 110-240 047H018300 4-160 s 110-240 047H018400 0.5-20 min 110-240 047H018500 ccessory for ETB Description Function Code Number DIN rail base for ETB For separate mounting of clip-on timers ETB 047H016466 10

Timers - DIN Rail Mounting TI, BTI, MTI With their robust design and many built-in functions, electronic timers TI, BTI, SDT and MTI are ideal for OEMs and panel builders: Easy time setting/electrical noise immunity Mechanical shock and vibration resistance Time ranges 0.1 s to 30 min for single function, Electronic timers and 0.05 s to 300 h for multi function Electronic timers Compact standard dimensions/din rail or adaptor mounting Single function electronic timers featuring: ON delay, OFF delay ON-delay electronic timers Time Range Voltage Range Contact Function Type Code Number 0.1-10 s 110-130 V a.c., 50-60 Hz 047H309000 3-300 s 110-130 V a.c., 50-60 Hz 047H309100 220-240 V a.c., 50-60 Hz 0.1-10 s 24 V a.c., 50-60 Hz 24 V d.c. 047H309200 220-240 V a.c., 50-60 Hz 0.3-30 s 24 V a.c., 50-60 Hz 1 changeover 047H310400 TI 24 V d.c. 220-240 V a.c., 50-60 Hz 3-300 s 24 V a.c., 50-60 Hz 24 V d.c. 047H309300 220-240 V a.c., 50-60 Hz 0.3-30 min 24 V a.c., 50-60 Hz 24 V d.c. 047H310500 OFF-delay electronic timers Time Range Voltage Range Contact Function Type Code Number 24 V a.c., 50-60 Hz 0.3-30 s 24 V d.c. 047H310600 24 V a.c., 50-60 Hz 3-300 s 24 V d.c. 1 changeover BTI 047H309500 0.3-30 s 220-240 V a.c., 50-60 Hz 047H310700 3-300 s 220-240 V a.c., 50-60 Hz 047H309900 11

Circuit Breakers CTI 15 Circuit Breakers CTI 15 cover the ranges from 0.25-16. This product range is modular, flexible and offers a large selection of clip-on auxiliary functions and accessories: auxiliary contact blocks, shunt releases, connection terminal, bus bars, and enclosures. Power ranges 0.1-15HP Short-circuit protection Operation switch (manual motor starter) Isolation switch (with locking device) Emergency stop switch ( with undervoltage trip) Indication functions: (On/Off) Circuit breakers CTI 15 Motor Load (HP), C3 Range, Electromagnetic 1 Phase 3 Phase Trip Code Number 115VC 230VC 230VC 460VC 575VC.25-0.4 4.4 047B305100 0.4-0.63 6.9 047B305200 0.63-1.0 11 047B305300 1.0-1.6 1/10 1 1 18 047B305400 1.6-2.5 1/10 1/6 3/4 1-1/2 2 28 047B305500 2.5-4.0 1/8 1/3 1 3 3 33 047B305600 4.0-6.3 1/4 3/4 2 5 5 69 047B305700 6.3-10 1/2 1-1/2 3 1-1/2 10 110 047B305800 10-16 1 3 5 10 15 176 047B305900 ccessories for circuit breakers CTI 15 Description Function Code Number uxiliary contact blocks for building in uxiliary contact blocks for CTI15 Bus bars for CTI15 CBI-NO (make) terminal 13-14 CBI-NO (make) terminal 23-24 CBI-NC (break) terminal 11-12 uxiliary contact blocks for lefthand mounting CBI 11 (1 make + 1 break), terminal 13-14, 21-22 For parallel connection of CTI 15 in panel CTS 45-3 (2 x 45 mm) CTS 45-5 (2 x 45 mm) For CTI 15 with auxiliary contact mounted on side CTS 54-2 (2 x 54mm) CTS 54-4 (4 x 54 mm) CTS 54-5 (5 x 54 mm) 047B304000 047B304100 047B304200 047B304900 047B309600 047B308600 047B308700 047B308800 047B308900 Plastic enclosures for circuit breakers CTI 15 (IP 55) pplication Pushbuttons Knockouts Type 1) 2) Code Number CTI 15 Start-Stop/reset 4 Pg 16/4 Pg 21 BXI 55 047B309100 1) With neutral and earth terminals 2) The enclosure also leaves space for a shunt release or an undervoltage release. 12

Circuit breakers CTI 25M, CTI 25MB, CTI 45MB, CTI 100 13 Circuit Breakers CTI M, MB, CTI 100 Circuit breakers CTI 25M, CTI 25MB, CTI 45MB, and CTI 100 cover the range (C3) from 0.1 to 90 in 4 product sizes: 0.1-25, 1.6-25, 6.3-45 and 40-90. Short circuit protection of motor installations Test function for thermal trip Manual reset function Indication for thermal trip Indication for magnetic trip (short circuit) Single phase protection Motor rating in HP Range Prospective short circuit Electromagnetic Protection 1 Phase 3 Phase current device 115V 230V 230V 460V 575V 480V 600V max. Type Code Number 0.1-0.16 - - - - - 65 47 2.1 047B314000 0.16-0.25 - - - - - 65 47 3.3 047B314100 0.25-0.40 - - - - - 65 47 5.2 047B314200 0.4-0.63 - - - - - 65 47 8.2 047B314300 0.63-1.0 - - - - 1/2 65 47 13 047B314400 1.0-1.6-1/10-3/4 3/4 65 47 21 047B314500 1.6-2.5-1/6 1/2 1 1-1/2 65 5 400 33 CTI 25M 047B314600 2.5-4.0 1/8 1/3 3/4 2 3 65 5 52 047B314700 4.0-6.3 1/4 1/2 1-1/2 3 5 65 5 82 047B314800 6.3-10 1/2 1 3 5 7-1/2 65 5 130 047B314900 10-16 3/4 2 5 10 10 10 5 208 047B315000 14.5-20 1 3 5-15 10 5 260 047B315100 18-25 1-1/2-7-1/2 15 20 10 5 325 047B315200 23-32 2 5 10 20 25 - - 416 047B316400 500 CTI 45MB 32-45 3 1-1/2 15 30 40 - - 585 047B316500 40-63 5 12 22 45 60 65 42 882 047B301400 CTI 100 63-90 7.5 20 30 85 85 65 30 1260 047B301500 uxiliary contacts and larm contacts for CTI 25M-MB, CTI S-SB, CTI 45MB-SB Type Function Code Number CB-10 uxiliary contact, 1NO (13-14), front mounting, max one per manual starter 047B319800 CB-11 uxiliary contact, 1NO+1NC (13-14, 21-22 ), front mounting, max one per manual starter 047B320000 CB-20 uxiliary contact, 2NO (13-14, 23-24 ), front mounting, max one per manual starter 047B320100 CB-02 uxiliary contact, 2NC (31-32, 41-42), front mounting, max one per manual starter. 047B320200 CB S-11 uxiliary contact, 1NO+1NC (33-34, 41-42), side mounting, max one per manual starter. 047B320300 CB S-20 uxiliary contact, 2NO (33-34, 43-44), side mounting, max one per manual starter. 047B320400 CBT 2T Thermal alarm contact (make, 27-28 ) + uxiliary contact 1NO (13-14), front mounting max one per manual starter 047B320700 CBT S-TM2 Thermal alarm contact (make, 55-56) + Magnetic alarm contact (break, 65-66), side mounting always direct onto the manual starter. 047B321100 Under voltage- and voltage trips for CTI 25M-MB, CTI 25S-SB, CTI 45MB-SB Type Function Code Number VTU Under voltage trip, 380-400V/50Hz, 440-460V/60Hz, D1-D2 047B322000

Spare parts and accessories for CTI Circuit Breakers ccessories for CTI 25M-MB, CTI 25 S-SB, CTI 45MB-SB Type Function Code Number BLK Black lockable rotary handle 047B324300 BDH Black door handle for mounting in panel doors 047B324900 RDH Red/yellow door handle for mounting in panel doors 047B325000 Extension rod for door handle BDH and RDH 047B313600 Connection terminal blocks and bus bars for CTI 25M-MB, CTI 25S-SB, CTI 45MB-SB Type Function Code Number BBT 25 Connection terminal block for CTI 25M-MB, CTI 25S-SB og CTI 16T-20TB 047B325900 BBC 25 45-2 Bus bar for CTI 25M-MB, CTI 25S-SB and CTI 16T-20TB (2x45mm) 047B326100 BBC 25 45-3 Bus bar for CTI 25M-MB, CTI 25S-SB and CTI 16T-20TB (3x45mm) 047B326200 BBC 25 45-4 Bus bar forl CTI 25M-MB, CTI 25S-SB and CTI 16T-20TB (4x45mm) 047B326300 BBC 25 45-5 Bus bar for CTI 25M-MB, CTI 25S-SB and CTI 16T-20TB (5x45mm) 047B326400 Connection terminal blocks and bus bars for CTI 25M-MB, CTI 25S-SB, CTI 45MB-SB Type Function Code Number CBI 100-20 uxiliary contact, 2NO (13-14, 23-24), for front mounting 047B311000 CBI 100-11 uxiliary contact, 1NO+1NC (13-14, 21-22), for front mounting 047B311200 CBI 100-BDH Red/yellow lockable door handle for mounting on panel doors 047B313400 Door handle extension rod for CBI 100-BDH 047B313600 14

For more information about Danfoss Motor Control Products or to place an order in the United States or Canada, please contact: Flodraulic Canada Corporate Office 45 Sinclair ve., Georgetown, ON, L7G 4X4 Hours of Operation Mon-Fri 8:30am -5pm P. 905-702-9456 F. 905-877-5616 TF. 1-800-361-6209 Email: dmc@flodraulic.com sthomas@flodraulic.com www.flodraulic.com 15

Here today. Here tomorrow. Danfoss is a leading global player within the development and production of mechanical and electronic products and controls. Since 1933, our extensive know-how has made modern life easier and we continue to break new ground in our core business areas. Every day, more than 250,000 items are produced at 70 factories in 25 countries. Impressive as these figures are, we are most proud of the way our dedicated employees apply the high quality components in customer solutions, adding value to the end product. Building strong partnerships is of great importance to us, because it is purely by understanding our customers needs that we can meet the expectations of tomorrow. This is also true in Industrial utomation, a Danfoss entity dedicated to focusing on the industrial world of today. Through us, you gain access to the entire Danfoss pool of technologies, with special emphasis on sensors and controls. We offer safer, more reliable and more efficient solutions in a close cooperation based on firm values. Danfoss, Industrial utomation 11655 Crossroads Circle, Baltimore, MD, 21220 ia.nam@danfoss.com www.danfoss.us IC.PK.C00.00.22/520B5827 September 2013