User Manual UNO-IPS2730. Intelligent Power System for PCs

Similar documents
User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

User Manual PPC-IPS. Intelligent Power System for PCs

User Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature

User Manual IDS-3206 Series. 6.5" Industrial Panel Mount Monitor

User Manual ADAM-6100EI Series. EtherNet/IP I/O Modules

User Manual VEGA K HEVC/H.265 Real-time PCIe Encoder Card

User Manual IDS-3106 Series. 6.5" Industrial Open Frame Monitor

User Manual IDS-3119 Series. 19" Industrial Open Frame Monitor

User Manual PCL channel Isolated Digital Output Card

EKI-2528PAI 8-port Industrial Unmanaged Ethernet Switch with 4-port PoE. User Manual

User Manual EKI-2728I. 8-port Industrial Unmanaged Gigabit Ethernet Switch

MIC-3002A Series. 3U 6-slot CompactPCI Enclosures with Rear I/O and 6" LCD. User Manual

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection

User Manual ECU-P1524PE HSR/PRP Module

User Manual DSD-5028 Series. 28" Industrial Stretched Signage Display Monitor

CR-4000/6000 SERIES CASH DRAWER USER S MANUAL

EKI-7526I 16 Port Unmanaged Industrial Ethernet Switch. User Manual

User Manual IDS-3217 Series. 17" Industrial Panel Mount Monitor

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

User Manual TPC-8100TR. 10.4" EN50155 Railway Panel Computer

User Manual. IDS-3215 Series. 15" Industrial Panel Mount Monitor

User Manual PCIE ch Digital I/O PCI Express Card

EKI-7529MI, EKI-7529MI/ST FX Port Unmanaged Industrial Ethernet Switch. User Manual

User Manual PCM Port CAN-Bus Mini PCIe Module with Isolation Protection

User Manual ITM-5117 Series. 17" Industrial LED Touch Monitor

User Manual PCL ch Isolated Digital I/O ISA Cards

User Manual IDS-3118W Series. 18.5" Industrial Open Frame Monitor

PD 2800/320 Series User s Manual

User Manual PCM-27D24DI. 24-ch Isolated Digital I/O and 2-ch Counter PCI Express Mini Card

User Manual PCI-1720U. 12-bit, 4-ch Isolated Analog Output Universal PCI Card

PCM PC/ bit Digital I/O Module. User Manual

User Manual. FPM-7181W Series. 18.5" Industrial Monitor with Projected Capacitive Touchscreen, Direct-VGA and DVI Ports

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

FPM-5151G/5171G/ 5191G Series

PCLD-8751 PCLD User Manual

User Manual ARK-6610/6620. Compact Mini-ITX Chassis

User Manual PPC Intel ATOM N2600 processor based microcomputer, with 15" color TFT LCD display

User Manual IPC U Industrial Rackmount Chassis for SHB and SBC

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

User Manual PCIE-1730H. 32-ch Isolated Digital I/O with Digital filter PCI Express Card

ITA-1711 Series Fanless Compact Embedded IPC with Intel Celeron Dual Core CPU Startup Manual

User Manual IDS-3115 Series. 15" Industrial Open Frame Monitor

UNO-1140/F. Advantech EVA x86 SoC Fanless Box PC with 1 x LAN, 8 x Isolated COM. User Manual

User Manual PCIE ch Digital I/O and 3-ch Counter PCI Express Card

User Manual TPC-2121T/2151T/2181W Series

User Manual SOM-AB5510

USB Channel Isolated Digital I/O USB Module. User Manual

AMAX-2750SY Series. 32-ch AMONet RS-485 Isolated Digital I/O Slave Modules. User Manual

IPC-611 Series 4U Rackmount Industrial Chassis User Manual

User Manual PPC-L62T. Intel Atom Processor-Based Panel PC with 6.5 Color TFT LCD Display

PCLD-8751/8761/ Channel Isolated D/I and Relay Board. User Manual

PCL ch Digital I/O ISA Card. User Manual

User Manual PCI ch Relay & 8-ch Isolated Digital Input PCI Card

User Manual EBPC Embedded Industrial Computer Chassis for 3.5 Biscuit SBCs

User Manual PCI ch Relay & 16-ch Isolated Digital Input PCI Card

User Manual. FPM-7000T Series. True-flat Industrial Monitor with 5-wire Resistive Touchscreen, Direct-VGA/DP ports

User Manual EKI-1221IEIMB EKI-1221IPNMB. Modbus TCP to PROFINET EtherNet/IP Protocol Gateway

Manual Version: V1.00. Video Decoder Quick Guide

User Manual PCIE ch Isolated Digital Input & 8-ch Relay Output PCI Express Card

DS-080. Ultra Slim Digital Signage Player

User Manual MIC-3955/3527 Series. 3U CPCI 4/8 Port RS-232/422/485 Communication Card

FPM-5151G Series. 15" XGA Industrial Monitor with Resistive Touchscreen, Direct-VGA, DVI Ports and DC10-30V Inputs. User Manual

User Manual IPC-510-B/C. 4U Rackmount Chassis for General Applications

User Manual APAX-5522PE. IEC Certified PAC with Marvel XScale CPU

User Manual TL-FO-HD. 4K Optical Fiber Extender. All Rights Reserved. Version: TL-FO-HD_160628

DS-081. Ultra Slim Digital Signage Player

FWA-6280A User Manual 1. FWA-6280A User Manual

User Manual RIO-3310B. 6U CompactPCI Rear Transition Card for MIC-3390 / MIC-3392

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

MIC Advantech CompactPCI. Modular Industrial Computer. 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane

UNO-2053GL. LX MHz Automation Computer with 2 x LAN, 2 x USB, 2 x RS-232, Audio. User Manual

SATA II HDD Canister KISS DA 435 Quick Reference Guide

User Manual SOM-AB5810

User Manual PCI-1750/PCI-1750SO. 32-ch Isolated Digital I/O PCI Card

User Manual PPC-4150W. Intel Atom D2550 processor based microcomputer, with 15.6" color TFT LCD display

PD 330 / 2606 Series User s Manual

UNO-2052E. GX2-400 UNO with 2xCAN, LAN, USB, RS-232. User Manual

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

User Manual PCI ch Isolated Digital I/O Card

PCL ch Analog Output ISA Card with 32-ch DI/O. User Manual

User Manual TREK-306DH In-Vehicle Smart Display

USB ks/s, 12-bit, USB Multifunction Module. User Manual

User Manual BAS-3000 Series. Direct Digital Controller

PCI-1727U. 12-ch Analog Output Card with Universal PCI. User Manual


DS-1H05 Ethernet-over-Coax Extender. User Manual

User Manual PUH4-H2. 4K HDMI Splitter 1x4. All Rights Reserved. Version: PUH4-H2_2016V1.2

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

4170 POS System Installation Guide

User Manual PCI ch Isolated Digital Input PCI Card

User Manual TL-TP70-HDC 70m HDBaseT Extender Set for HDMI, RS232 & IR All Rights Reserved Version: TL-TP70-HDC _160926

Operating Instructions

PD 309 / 2605 Series User s Manual

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

User Manual UNO-2272G 電腦. Intel Atom /Celeron Palm- Size Automation Computer with 1 x GbE, 2 x mpcie, VGA/HDMI


PCI-1753 PCI-1753E. User Manual

ADAM-5511 Quick Start

Network Camera. Quick Guide DC-B1203X. Powered by

Toll Free: Tel: Fax:

Transcription:

User Manual UNO-IPS2730 Intelligent Power System for PCs

Copyright The documentation and the software included with this product are copyrighted 2016 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. However, Advantech Co., Ltd. assumes no responsibility for its use, nor for any infringements of the rights of third parties, which may result from its use. Product Warranty (2 years) Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for two years from the date of purchase. This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation. Advantech assumes no liability under the terms of this warranty as a consequence of such events. Because of Advantech s high quality-control standards and rigorous testing, most of our customers never need to use our repair service. If an Advantech product is defective, it will be repaired or replaced at no charge during the warranty period. For outof-warranty repairs, you will be billed according to the cost of replacement materials, service time and freight. Please consult your dealer for more details. If you think you have a defective product, follow these steps: 1. Collect all the information about the problem encountered. (For example, CPU speed, Advantech products used, other hardware and software used, etc.) Note anything abnormal and list any onscreen messages you get when the problem occurs. 2. Call your dealer and describe the problem. Please have your manual, product, and any helpful information readily available. 3. If your product is diagnosed as defective, obtain an RMA (return merchandize authorization) number from your dealer. This allows us to process your return more quickly. 4. Carefully pack the defective product, a fully-completed Repair and Replacement Order Card and a photocopy proof of purchase date (such as your sales receipt) in a shippable container. A product returned without proof of the purchase date is not eligible for warranty service. 5. Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer. Part No. 2003S27300 Edition 1 Printed in Taiwan November 2016 UNO-IPS2730 User Manual ii

Declaration of Conformity CE This product has passed the CE test for environmental specifications. Test conditions for passing included the equipment being operated within an industrial enclosure. In order to protect the product from being damaged by ESD (Electrostatic Discharge) and EMI leakage, we strongly recommend the use of CE-compliant industrial enclosure products. FCC Class A Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 警告使用者 : 這是甲類資訊產品, 在居住的環境中使用時, 可能會造成射頻干擾, 在這種情況下, 使用者會被要求採取某些適當對策 FM This equipment has passed the FM certification. According to the National Fire Protection Association, work sites are classified into different classes, divisions and groups, based on hazard considerations. This equipment is compliant with the specifications of Class I, Division 2, Groups A, B, C and D indoor hazards. Technical Support and Assistance 1. Visit the Advantech web site at www.advantech.com/support where you can find the latest information about the product. 2. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance. Please have the following information ready before you call: Product name and serial number Description of your peripheral attachments Description of your software (operating system, version, application software, etc.) A complete description of the problem The exact wording of any error messages iii UNO-IPS2730 User Manual

Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage. 7. The openings on the enclosure are for air convection. Protect the equipment from overheating. DO NOT COVER THE OPENINGS. 8. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet. 9. Position the power cord so that people cannot step on it. Do not place anything over the power cord. 10. All cautions and warnings on the equipment should be noted. 11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage. 12. Never pour any liquid into an opening. This may cause fire or electrical shock. 13. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel. 14. If one of the following situations arises, get the equipment checked by service personnel: The power cord or plug is damaged. Liquid has penetrated into the equipment. The equipment has been exposed to moisture. The equipment does not work well, or you cannot get it to work according to the user's manual. The equipment has been dropped and damaged. The equipment has obvious signs of breakage. 15. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW -20 C (-4 F) OR ABOVE 50 C (122 F). THIS COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT. 16. CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER, DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. 17. ATTENTION: DANGER D'EXPLOSION SI LA BATTERIE EST INEXACTE- MENT REMPLACÉE. REMPLACEZ SEULEMENT AVEC LA MÊME CHOSE OU LE TYPE ÉQUIVALENT RECOMMANDÉ PAR LE FABRICANT, JETTENT LES BATTERIES UTILISÉES INSTRUCTIONS DE S SELON FABRICANT DES'. The sound pressure level at the operator's position according to IEC 704-1:1982 is no more than 70 db (A). DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein. UNO-IPS2730 User Manual iv

Safety Precaution - Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage. To avoid electrical shock, always disconnect the power from your PC chassis before you work on it. Don't touch any components on the CPU card or other cards while the PC is on. Disconnect power before making any configuration changes. The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components. Battery Information Batteries, battery packs, and accumulators should not be disposed of as unsorted household waste. Please use the public collection system to return, recycle, or treat them in compliance with the local regulations. v UNO-IPS2730 User Manual

UNO-IPS2730 User Manual vi

Contents Chapter 1 General Information...1 1.1 Introduction... 2 1.2 Specifications... 2 1.3 Dimensions... 3 Chapter 2 Installation...5 2.1 Introduction... 6 Figure 2.1 IPS Wiring... 6 Figure 2.2 IPS Connection Chart... 6 2.2 LED Indication... 7 2.3 Battery safety protection control... 7 2.4 A Quick Tour... 8 Figure 2.3 Overview... 8 Figure 2.4 IO Connectors... 8 2.5 DIN-rail Installation... 9 2.6 Power cable & Control Cable Installation... 10 Chapter 3 UNO-IPS2730 Adjustment Tool...11 3.1 Notice of Use... 12 3.1.1 Operating System Setting Environment... 12 3.2 UI Introduction - Base... 12 3.2.1 Select COM Port... 13 3.2.2 Power State Selection (S4 or S5)... 13 3.2.3 IPS Status... 13 3.2.4 Final Countdown for Shutdown... 13 3.2.5 Operating Temp. for Battery Pack... 13 3.2.6 Max. Time to Turn Off IPS... 13 3.2.7 Auto Run... 14 3.3 UI Introduction - Advanced... 14 3.3.1 Time to Shut-down PC after Power outage... 14 3.3.2 "Max" time to Shut-down PC after Power Outage... 14 3.3.3 Time to Turn-Off IPS after Shut-down command... 14 vii UNO-IPS2730 User Manual

UNO-IPS2730 User Manual viii

Chapter 1 1General Information This chapter gives background information on the IPS. Sections include: Introduction Specifications Dimensions

1.1 Introduction UNO-IPS2730 lightweight and intelligent power management module protects the system from electrical damage and greatly reduces the risk of losing data. UNO- IPS2730 module serves as temporary power during power spikes and allows for safe system shutdown. 1.2 Specifications Input Input Voltage 18-36 Vdc Output Output Voltage 24Vdc +/-10% Typical output current 3A Battery Capacity 14.4 VDC, 2730 mah Battery Cycle life 300 times of charge circle Protection Short-circuit protection Yes Certification EMC CE, FCC, CCC Safety UL, CB, CCC Dimensions (W x D x H) 217 x 89 x 69 mm (8.24" x 3.5" x 2.72") Operating Temperature 0-45 C Environment -20 ~ +50 C (less than 1 month) Storage Temperature -20 ~ + 40 C (less than 3 months) -20 ~ + 20 C (less than 1 year) I/O Connectors Monitor & Set IPS RS-232 This product is intended to be supplied by a Listed Power Adapter or DC power source, rated 18-36 VDC, 5.5-3.0A minimum and Tma 45 degree Celsius, if need further assistance with purchasing the power source please contact Advantech for further information. UNO-IPS2730 User Manual 2

1.3 Dimensions 44.05 26.55 10.5 9.05 5.4 4 164.80 154.80 125.40 107.90 216.8 215.8 203.8 191.8 55.6 62.1 68.6 79 89 53.1 55.6 Chapter 1 General Information 90.40 61 51 62 27 44.50 61 51 3 UNO-IPS2730 User Manual

UNO-IPS2730 User Manual 4

Chapter 2 2Installation Sections include: Introduction LED indication Battery safety protection control A quick tour DIN-Rail installation Power cable & control cable Installation

2.1 Introduction The UNO-IPS2730 module serves as temporary power during power spikes. When the power is off, the UNO-IPS2730 delays the shut down time to allow work to be finished. Once the delay shut down time has expired the UNO-IPS2730 sends a shutdown order to the PC. Refer to the figure below for a description of the connection. Figure 2.1 UNO-IPS2730 Wiring Figure 2.2 UNO-IPS2730 Connection Chart UNO-IPS2730 User Manual 6

2.2 LED Indication LED Bright (ON) Dark (OFF) Blinking DC_IN LED DC_IN DC_IN loss No DC input & PC is going to switch off System LED System ready System not work NA Battery LED BAT ready Not detect BAT Charge LED NA BAT no charging 1. Low battery (Note 1) 2. BAT abnormal (0.5Hz blinking) (Note 2) 1. BAT charging (1Hz blink) 2. BAT abnormal (0.5Hz blinking) (Note 2) Note! 1. Low battery BAT 15%, BAT LED blinking, 16% return normal state. 2. BAT abnormal BAT temperature 60 C, BAT & CHG LED blinking (0.5Hz), 55 C return normal state. Chapter 2 Installation 2.3 Battery safety protection control a. Battery temperature 65 C, cut-off battery function. b. Battery capacity 5%, cut-off battery function. 7 UNO-IPS2730 User Manual

2.4 A Quick Tour Before setting up the UNO-IPS2730, take a moment to become familiar with the locations and purposes of controls, connectors and ports, illustrated in the figures below. When placed upright on the desktop, UNO-IPS2730 look like this below. Figure 2.3 Overview A B C D E F A. System reset B. Status indicators C. COM port D. DC out (2 pins) E. DC input (2 pins) F. Grounding Figure 2.4 IO Connectors UNO-IPS2730 User Manual 8

2.5 DIN-rail Installation UNO-IPS2730 can be installed on a DIN-rail. Take the DIN-rail bracket and screws from the accessory bag and attach to UNO-IPS2730. Chapter 2 Installation 9 UNO-IPS2730 User Manual

2.6 Power Cable & Control Cable Installation Connect the cables after installation of UNO-IPS2730. Below we use the example of an UNO-3382G as a loading machine. If customers use another PC as a loading machine, install cables according to the other machines connector pin definitions. UNO-IPS2730 User Manual 10

Chapter 3 3UNO-IPS2730 Adjustment Tool

3.1 Notice of Use 3.1.1 Operating System Setting Environment UNO-IPS2730 Adjustment Tool supports Windows XP/7/8/8.1. For each operating system, a required.net Framework installation will be necessary. Please refer to the following table for installation..net Framework requirement list: Operating System Required SW: Version Windows XP Net framework 2.0 2.0.50727.42 Windows 7 N/A N/A Windows 8 Net framework 3.5 3.5.30729.6387 Windows 8.1 Net framework 3.5 3.5.30729.6387 Windows 10 Net framework 3.5 3.5.30729.6387 Note! You can download UNO-IPS2730 Adjustment Tool from the Advantech support website of UNO-IPS2730. 3.2 UI Introduction - Base UNO-IPS2730 User Manual 12

3.2.1 Select COM Port Select the UNO-IPS2730 COM port. 3.2.2 Power State Selection (S4 or S5) This option allows you to select the power status of your PC between hibernation* (S4) or shutdown* (S5) when UNO-IPS2730 is activate. Note! 3.2.3 UNO-IPS2730 Status UNO-IPS2730 working status: green means normal and red means abnormal. DC-in: Shows if DC power source for UNO-IPS2730 is normal or not. Battery: Shows if UNO-IPS2730 battery is working normally or not. 3.2.4 Final Countdown for Shutdown The UNO-IPS2730 will shutdown / hibernate your PC after the timer counts down to zero. Note! Note! Hibernation (S4): All data/programs status will be saved in storage. You can resume you previous working state after S4 awakens. Shut down (S5): Shutdown process can be paused due to unfinished program execution or unsaved data. The time can be adjusted between 5 to 360 seconds or maximum battery supply time. Please refer to 4.3.1 and 4.3.2 for further settings. If stable DC power is supplied to UNO-IPS2730 before the timer counts down to zero, the value will automatically be reset and stop counting. Chapter 3 UNO-IPS2730 Adjustment Tool 3.2.5 Operating Temp. for Battery Pack This section represents the current battery pack temperature. Note! The maximum operating temperature is 45 C. 3.2.6 Max. Time to Turn Off UNO-IPS2730 If a power shortage occurs, UNO-IPS2730 will display the dynamic estimated time of power left from UNO-IPS2730 s battery. Note! This time will be adjust based on current power usage of your PC. 13 UNO-IPS2730 User Manual

3.2.7 Auto Run If you check this option, the UNO-IPS2730 Adjustment Tool will automatically run every time you turn on your PC. 3.3 UI Introduction - Advanced 3.3.1 PC Shut-down Time after Power Outage This advanced setting allows customers to adjust the Final Countdown Time for Shutdown between (4.2.4) 5 to 360 seconds. 3.3.2 "Max" Time to PC Shut-down after Power Outage If users check on this option, the Final Countdown Time for Shutdown will be dynamic with the battery discharge state. UNO-IPS2730 will turn off your PC as soon as the battery reaches 15% or less of power capacity. 3.3.3 Time to Turn-Off UNO-IPS2730 after Shut-down Command This parameter can set the time to shut down after sending a shut down/hibernate signal to the PC to protect battery life. You can set between 1 and 5 minutes. UNO-IPS2730 User Manual 14

15 UNO-IPS2730 User Manual Chapter 3 UNO-IPS2730 Adjustment Tool

www.advantech.com Please verify specifications before quoting. This guide is intended for reference purposes only. All product specifications are subject to change without notice. No part of this publication may be reproduced in any form or by any means, electronic, photocopying, recording or otherwise, without prior written permission of the publisher. All brand and product names are trademarks or registered trademarks of their respective companies. Advantech Co., Ltd. 2016