PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping

Similar documents
PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping

PCR R, PCR RE 2 Channel, 433MHz Penta Receiver with Frequency Hopping

PCR43301RE 1-Channel, 433MHz Penta Receiver with Frequency Hopping

PCR43301RE ELSEMA. . and anywhere else you need a wireless signal to transmit a contact closure. Description

PCR R 2 Channel, 433MHz Penta Receiver with Frequency Hopping

PCR43302RE, PCR43302R 2-Channel, 433MHz Penta Receiver with Relay outputs

PentaTimer Receiver Two Channels, 433MHz Penta Receiver with Time Clock Functions

GLR43303, GLR43304 Multi-Channel 433MHz Gigalink Receiver

ELSEMA GLR Applications Automatic gates. Security systems. Timer controlled outputs. Simple on/off functions.

User Manual. PCKeypad Wireless Keypad

Eclipse MCi. Variable Speed Drive Controller with Eclipse Operating System (EOS) 3rd Edition. VSD kits suitable for motors ranging from 0.4 to 2.

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

GL116 ENCODER/DECODER MANUAL GLOLAB CORPORATION

SHENZHEN Lejing INDUSTRY DEVELOPMENT CO.LTD Whatsapp:

Wireless Key fob, Key pad & Receiver Range

G G receiver with relay output for opening sliding, swing gates, doors or switching devices

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

RF4431 wireless transceiver module

ELSEMA 3 Phase Control Board, 3PH2, 3PHE

6222 Two Door Module Technical Operations Manual

GL-104 ENCODER/DECODER MANUAL GLOLAB CORPORATION

Installing Keypad and Backplate

Digital Keypad Introduction

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Installation & User Manual

DOLXFD1000B. Waterproof Access Control/Reader

Installation & User Manual V2.08

RF4432 wireless transceiver module

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

UP200-GSM Intercom and access control unit operating on mobile GSM network

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

PLEASE READ BEFORE INSTALL. ECGO-GKP Cellular Telephone Entry

Wireless Expansion Module V2.0 OMN-RCV3. Reference & Installation Manual. Stand-Alone System

WLS-TC Specifications

DG-800 Stand-Alone Proximity Reader Instruction Manual

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

Telephone Line Monitor USER GUIDE

902 MHz Wireless Relays Application Manual Bulletin B1867

2-Way Wireless I/O Expander Installation Guide

page A.0240 Full_Product_catalogue_ BM.indb 118

Single Door Standalone Access Control User Manual

SMS Transceiver V3 User manual

D2112 Keypad Diagnostics

SmartLock Controller INSTALLATION MANUAL

Light & Sound Control Module

180 Series Keypad. Handbook. Revision 2.1

Applications. Quark-Elec Application Note

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Intelligent Devices IDI 1100 Series Technical Manual

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

GSM HOME SECURITY SYSTEM

Model SFS01-V2 IMPORTANT! MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH

U-FLASH Setup Guide U-FLASH.

RadioRA 2 Visor Controls

Latching, Sequence and Impulse Relays Application Data

ETH044-4 SSR (230VAC) and 4 Digital IO

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

VIS-3200 / VIS-3201 User Manual

e-ask electronic Access Security Keyless-entry

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

LH Long Range Business Wireless Doorbell Kit User Manual

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Installation & Operation and Maintenance

Fingerprint Access Control F1. User Manual

Remote control access is where security and convenience meet. Centurion Systems has a range to comply with your site s unique security requirements,

Celadon, Inc. TRX Series Infrared Remote and Receiver Assembly and Operation Instruction Manual

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Home Security System with Remote Home Automation Control

RadioRA 2 Visor Controls

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.

DTMF-4HC. DTMF decoder board with four high current relays. Copyright 2004 Intuitive Circuits, LLC

C5S120 Installation and Connection Guide

Click Save to return to the main Setup screen.

Technology Security Low consumption

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Installation and User Manual

Helios PD Large Display Meter Quick Start Guide

Installation & User Manual V1.0

HEATIT Z-DIN 616. DIN-rail module. Installation- and user manual

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

NETRONICS HS3500 CONTROLLER

UP100-GSM. GSM based intercom and access control. Installation and user manual

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

TIME DELAY RELAYS Product Summary

Each receiver has 4 switched outputs, which, using our one touch easy-learn process can be controlled from any switch on any compatible transmitter.

AS Keypad User Manual

Hi-tech. Advanced. Multifaceted. These are some of the terms that best describe our diverse range of access control offerings.

CM-110SK Standalone Keypad Installation Instructions

902 MHz Wireless Relays Application Manual Bulletin B1867

Quick Start Guide. ELPRO 105U-L Wireless I/O Receiver Unit. man_105u-l-r_quickstart_v1-8.doc

The Packs Infotel. GSM Converter V2. Installation Manual V7

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Preliminary Product Overview

Emergency Dialer DIAL-ALERT MODEL: AD-433S.

TOUCHLOCK compact. Ins-182 Date code:

Transcription:

PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping Features Frequency hopping between 433.10 to 434.70MHz 12-way dipswitch or encrypted coding Momentary and latching modes are user selectable. Unlimited remotes can be programmed to the receiver Antenna diversity for robust link with extended range Compatible with PentaFOB and PentaCODE remotes Wide operating supply voltage and low current consumption On-board diagnostic LED s to indicate correct power, reception and relay activation Applications Keyless access control for automatic gates and doors Equipment and machinery control for factories and warehouses Home automation i.e. garden lights, swimming pool control etc. Security, lighting and automotive controls. and anywhere else you need a wireless signal to transmit a contact closure Description This receiver is compatible with PentaFOB and PentaCODE remotes. The PentaCODE dual coding system gives the installer the option to use the classic 12-way dip switch coding or one of over 17 billion encrypted codes. With the 12-way dip switch, just match the keyring remotes and the receiver's dip switch and it's coded. With the encrypted code you switch all the 12-way dip switches OFF and the remote and receiver automatically goes into the encrypted coding. Please see coding instructions for encrypted coding procedure. The receiver is available as a standalone card with relay outputs or enclosed in an IP66 rated weatherproof case. Output Modes Relay output on the receiver can function in either momentary or latching mode. By default the mode is set to momentary. Modes selectable from the 4-way dipswitch. Dipswitch 1 corresponds to relay channel 1 and dipswitch 2 corresponds to relay channel 2 and so on. Factory Default = Momentary Momentary - Output is active for as long as the transmitter button is pressed. This is a standard mode on most automatic gates or garage door openers. Latching Security Latching - Output remains active until next press of the transmitter button. Similar to switching "on" and "off" a light. - Output remains active until power to the receiver is removed. Similar to security alarms and fire alarms. To activate the security latching mode, a link needs to be soldered into the hole marked as latching. Customised Software Custom output modes can be programmed to do special functions. Call Elsema for more details.

Products in the Range PCR43301RE 1-Channel Receiver with Relay Output. Enclosed in a case PCR43302P 2-Channel Plug in type Receiver with Open Collector Output PCR43302R 2-Channel Receiver with Relay Outputs PCR43302RE 2-Channel Receiver with Relay Outputs. Enclosed in a case PCR43301240R 1-Channel Receiver with 240VAC mains supply PCR43301240RE 1-Channel Receiver enclosed in an IP66 case PCR43302240R 2-Channel Receiver with 240VAC mains supply PCR43302240RE 2-Channel Receiver enclosed in an IP66 case PCR43304R 4-Channel Receiver with Relay Outputs PCR43304RE 4-Channel Receiver enclosed in an IP66 case PCR43305R 5-Channel Receiver with Relay Outputs PCR43305RE 5-Channel Receiver enclosed in an IP66 case

Technical Data Supply Voltage 10.0 to 28.0 Volts AC or 11.0 to 36.0 Volts DC Can use Elsema s AC power pack PP12 or PP24 Standby Current 15 ma stand by at 24VDC Current Consumption 91 ma with all relays On Frequencies 433.100 to 434.700MHz Receiver Sensitivity 0.316uV (-117dBm) Operating Temperature Range -5 to 50 C Receiver Memory Storage Unlimited Remotes Decoding System Encrypted 17 billion codes combinations or On board 12-way code switch Outputs 4 change over relay outputs, rated at 10 Amps 240VAC each. Relay Contacts Connections Antenna 1 Common (C), Normally Closed (NC) & Normally Open (NO) Supply and Antenna is a screw type terminal block Relay outputs are plug-in type terminal block ANT433 series for long range applications. Antenna wire for short range applications Antenna 2 Use second antenna for extended range Operating Range Refer to the remote control or transmitter datasheet Dimensions 130 x 70 x 27 (PCR43304R), 200 x 100 x 73 (PCR43304RE) Weight 136grams (PCR43304R), 580grams (PCR43304RE) Useable Transmitters FOB433 series and PCK series

Block Diagram ELSEMA

PCR43304R 12/24 Volts AC/DC Application

PCR43304R, 110/240 Volts AC Application

PentaFOB Programming Instructions Coding the PentaFOB remotes and receivers can be done in 2 different ways. 1. Using the Receiver 2. Using another Remote Control Coding using the Receiver 1. Check that all switches are OFF on the receivers 12-way dip switch 2. Press and hold the program button on the receiver 3. Press the remote button for 2 seconds, receiver LED will flash and then turn Green 4. Release the button on the receiver and the remote 5. Press remote control button to test the receiver output Coding using another Remote Control 1. Open the case of a remote control that is already programmed and press and release the program button on the back of the board 2. Press the new remote control button for 2 seconds 3. Press the new remote control button again to test the receiver output Deleting Receivers Memory Short the Code Reset pins on the receiver for 10 seconds. This will delete all the remotes from the receiver s memory. PentaFOB Programmer This programmer allows you to add and delete certain remotes from the receiver memory. This is used when a remote control is lost or a tenant moves from the premises and the owner wants to prevent un-authorised access. PentaFOB Backup Chips This chip is used to backup or restore the contents of a receiver. When there are 100 s of remotes programmed to a receiver the installer normally backups the receiver memory in case the receiver is damaged.

PentaCODE Programming Instructions 12- Way Dip Switch Coding 1. Set a random code on the receiver dip switch by flicking the dip switches "On" or "Off". (DO NOT USE THE DEFAULT FACTORY SETTING FOR THE 12-WAY DIP SWITCH AS THIS IS A COMMON CODE) 2. Open the battery cover in the PentaCODE remote. 3. Match the 12-way dip switch to the receivers 12-way dip switch. 4. Press button 1 on the remote and the receiver output should activate. This is indicated by the receiver LED. To program the same PentaCODE remote buttons 2, 3 or 4 to another receiver change dip switch 11 and 12 in the 2nd, 3rd and 4th receivers. For example: Receivers Dip Switch 11 Receiver Dip Switch 12 Receiver 1 Off Off Receiver 2 On Off Receiver 3 Off On Receiver 4 On On Dip switches 1 to 10 should all be the same in the remotes and the receivers. Encrypted Coding - (All 12-Way Dip Switches must be "Off") Coding the PentaCODE remotes and receivers can be done in 3 different ways. 3. Receiver to a Remote 4. Remote to a Receiver 5. Remote to a Remote Receiver to a Remote 1. Press and hold the program button 1 on the receiver. 2. Press the remote button you want to program for 2 seconds, receiver LED will flash Green 3. Release the button on the receiver and the remote. 4. The LED on the PentaCODE remote will flash to confirm the coding has been successful. Remote to a Receiver / Remote to a Remote Set one of the remotes or receivers to broadcast its code. The broadcaster s code will be programmed to the other units. - To broadcast the remotes code make sure all 12 dip switches are "off". Then press and hold button 1 and flick dip switch 12 "on" and then "off". This is confirmed by the LED's being on for 10 seconds. You can release the remotes button 1. - To broadcast the receivers code make sure all 12 dip switches are "off" and then flick dip switch 12 "on" and then "off". This is confirmed by the green LED being on for 10 seconds. While broadcasting the code press button 1 on a different remote or receiver for 1 second and then release the button. The LED will flash twice to confirm successful programming. Broadcasting will be latched on for 10 seconds or stop if any dipswitch is turned on. Deleting Receivers Memory Short the CC pin on the receiver for 10 seconds. This will delete all the remotes from the receivers memory.