Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators

Similar documents
Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators

Programming tools for digital electronics Atos PC software, USB adapters, cables and terminators

Proportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20

Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32

Seals material: omit for NBR (mineral oil & water glycol) PE = FPM. Series number

Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 4401 size 06

Proportional relief valves type AGMZO-A* two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32

Digital electronic TES/LES drivers integral-to-valve format, for proportional valves with one or two spool position transducers

Proportional throttle cartridges type LEQZO-A*, 2-way without position transducer, nominal sizes 16, 25 and 32

Digital electronic REB/RES drivers integral-to-valve format, for proportional valves with integral pressure transducer

Proportional relief valves type RZMO-A*

Proportional pressure valves with remote pressure transducer digital, closed loop high performances, rugged design

Servoproportional valves type DLHZO-TE and DLKZOR-TE sleeve execution, direct operated, with position transducer, ISO 4401 size 06 and 10

Proportional relief valves type RZMO-A* with Pmax 500 bar direct operated, without integral pressure transducer, ISO 4401 size 06

Proportional 2-way throttle cartridges high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100

Fieldbus BC (CANopen), BP (PROFIBUS DP), EH (EtherCAT), EW (POWERLINK), EI (EtherNet/IP), EP (PROFINET IRT)

Proportional directional valves type DHZO-TES and DKZOR-TES direct operated, with position transducer, ISO 4401 size 06 and 10

Proportional electrohydraulic controls for PVPC pumps pressure-flow combined P/Q controls, analog or digital

Proportional throttle cartridges type LIQZO-T*, 2-way with position transducer, ISO 7368 sizes from 16 to 50

Servoproportional valves type DLHZO and DLKZOR

TWO CHANNELS REDUNDANT SAFETY ARCHITECTURE SINGLE CHANNEL NON-REDUNDANT SAFETY ARCHITECTURE

Proportional throttle cartridges type LIQZO-L*, 2-way high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100

Analog or Digital 08E001 RI-* drivers

Proportional directional valves type DPZO-T* two stage, with position transducer, ISO 4401 sizes 10, 16 and 25

LVX Control Unit. Features:

Fieldbus slave modules w/o I/Os

Proportional throttle cartridges type LIQZO-L*, 2-way high dynamics, with two position transducers, ISO 7368 sizes from 16 to 100

Proportional directional valves type DPZO-T* two stage, with position transducer, ISO 4401 sizes 10, 16 and 25

Inclination sensors 1-dimensional, measuring range

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

Inclination sensors 2-dimensional, measuring range up to ±90

CANopen. CiA Draft Recommendation DR Cabling and Connector Pin Assignment. Version 1.1 Date: 20 April CAN in Automation (CiA)

Applications: Power generator sets and control systems for industrial engine applications.

TM251MESC controller M251 Ethernet CAN

Hydraulic Power Limitation. Real Time Fieldbus Reference. Enhanced Diagnostic. E-SW programming software. Set code (see note) Series number

Control blocks CPX-CEC- -V3

System Control Unit (SCU) for Burkert Process Instruments

Fieldbus Gateway Type ME43

Structure and Function

Mounting Card MC1XZDCR. Accessories. Drive Compatibility. ZDR300EE12A8LDC Drives Supported ZDCR300EE12A8LDC

TM241CEC24R controller M IO relay Ethernet CAN master

TM251MESC controller M251 Ethernet CAN

MGate 4101-MB-PBS Series

Proportional throttle cartridges type LIQZO-L*, 3-way high dynamics, with two position transducers, sizes from 25 to 80

DSC FIELDBUS MODULES...

Revision to the Operating Instructions

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

High Performance proportional 2-way cartridges with two position transducers, ISO 7368 sizes from 16 to 100

CAN-ISA/200. ISA to CAN Interface. Hardware Installation and Technical Data. Hardware Installation and Technical Data CAN-ISA/200 Rev. 1.

PA ROUTERS. The following criteria can be applied when choosing the network transition:

Servoproportional 3-way cartridges digital, with two position transducers, sizes from 25 to 80, rugged design

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

GW-7553-CPM PROFIBUS/CANopen GATEWAY. User's Manual

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

CANOpen System Installation manual rev. 3.0

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

VersaMax IP Input Module

CAN-USB Converter Pro Installation Guide

DeviceNet System Installation manual rev. 3.0

Control block CPX-CM-HPP

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

Digital DRIVE for Brushless motor MD Serial

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

Product Specification

I-7550E PROFIBUS/Ethernet Converter. User's Manual

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Anybus-CC CFW-11. User s Manual. Phone: Fax: Web: -

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

PROFIBUS DP/CAN Gateway PCA-100. User Manual

SAI Active Universal Pro

SK TU4-PBR Part number:

PB600/H1 BASIC SYSTEM

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

Multi-axis controller V 8 / VV 8

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Mobileye EyeCAN (with CAN sniffer cable) User Guide

Characteristics and functioning

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

MGate 5102-PBM-PN Series

MODEL DRIVER Ic Ip VDC

USB to RS-422/485 Serial Adapter

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

USB Connectivity. USB Connectivity

CPC 01/02. Description. x86 Computer Module. Datasheet

WLAN Products 2.1 Overview P WLAN Remote Maintenance Device P WLAN Converter P Applications P2-4-1

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

XC-CPU-201 XC-CPU-201-XV

Proportional 2-way cartridges high performance digital, with two position transducers, ISO 7368 sizes from 16 to 100, rugged design

Addendum for 125B Bushealth Measurements

MPCR Series Profibus-DP Technical Manual

Industrial Serial Device Server

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

CPCI-CAN/200. CompactPCI-CAN-Interface. Hardware-Installation and Technical Data. Installation and Technical Data CPCI-CAN/200 Rev. 2.

CO4013-EVA. Evaluation Board For CANopen Joystick Controller CO4013. General Description. Features. Ordering Information.

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Transcription:

www.atos.com Table GS00-0/E Programming tools for digital electronics Atos PC software, adapters, cables and terminators POWER SUPPLY 4VDC Programming software Personal Computer Isolator Cable Proportional valve with integral driver Adapter Cross Cable direct PC connection available for TEB/LEB drivers and integral closed loop drivers/controllers series 40 POWER SUPPLY 4VDC adapter PC connection The E-SW / Z-SW programming software are the entry door to the Atos digital technology. They are supplied in DVD format and can be easily installed on a desktop or a notebook computer. The intuitive graphic interface allows to: set up valve s functional parameters verify the actual working conditions identify and quickly solve fault conditions adapt the factory preset parameters to the application requirements store the customized setting into the valve archive the customized setting into the PC The graphic interface is organized in pages related to different specific groups of functions and parameters. The software automatically recognizes the connected valve model and adapts the displayed parameter groups, according to the selected access level. The programming software is available in different versions according to the driver and controller communication interfacing: PS = (NP), Serial (PS) and Infrared (IR) EH = EtherCAT Fieldbus communication software (BC, BP and EH) includes also dedicated manuals and configuration files for user self management of the Atos electronics, using a fieldbus master. Features: automatic valve recognition multilevel graphic interface numeric parameters settings (scale, bias, ramp, linearization, dither, etc.) real-time parameters modification diagnostic and monitor signals preset data storing into the digital driver and controller internal oscilloscope function internal database of customized preset DVD contents: software installer user manuals fieldbus communication manuals and configuration files (BC, BP, EH) 1 PROGRAMMING SOFTWARE - see section 7 E - SW - PS - * / * Programming software: E-SW = for valve drivers Z-SW = for axis controllers Options, see section 7 : S = for alternated P/Q controls (only for E-SW software) Communication interfaces: PS = (NP), Serial (PS) and Infrared (IR) EH = EtherCAT (1) Supplies, see section 7 : - = first supply N = next supply (1) E-SW-EH and Z-SW-EH allow driver/controller programming only through /Serial communication, according to relevant electronic model code GS00

CABLE and ISOLATOR - see sections 10, 11 The cable directly connects of integral closed loop drivers/controllers. Optional isolator adapter can be installed between cable and PC. WARNING: drivers/controllers is not isolated! Use of isolator adapter is highly recommended for PC protection: wrong earthing connections may cause high potential difference between GNDs, generating high currents that could damage the PC connected to integral closed loop drivers/controllers. E - C - SB - / M1 E - C = Cable E - A = adapter Connector, drivers/controllers side - only for cable E - C: M1 = to standard integral drivers/controllers Isolator connector, Cable side - only for adapter E - A: OPT = to cable communication Connector, PC side: = from PC COMMUNICATION ADAPTERS - see section 11 The adapters have to be connected to the communication port of the PC to activate a proper communication interface towards Atos digital electrohydraulics. For PS versions and AES drivers with serial port always present, the adapter is not required if the PC is already equipped with a RS serial communication port. E - A - PS - / Adapter Communication interfaces: PS = Serial (1) Connector, PC side: = from PC Connector, drivers/controllers side: = to serial or fieldbus cables IR = to infrared E-MI-AS drivers (1) for AES and Z-ME-KZ select E-A-PS-/ - see 11. 4 CROSS CABLES - see section 1 The cross cables connect the connector of the adapter with the communication port of the digital drivers/controllers. E - C - PS - / M1 Cross Cable Communication interfaces: PS = Serial (1) Connector, PC/adapter side: = from connector Connector, drivers/controllers side: M1 = to standard integral drivers/controllers M8 = to Ex-proof integral drivers (for PS) RA = to Ex-proof integral drivers (for BC, BP) RJ4= to E-BM-AS drivers = to Z-ME-KZ controllers (1) for AES select E-C-PS-/M1 - see 1.1 TERMINATORS - see section 14 For CANopen (BC) or PROFIBUS DP (BP) the fieldbus terminator has to be used according to the schemes showed at section 14. E - TRM - BC - M1 / PM Terminator Connector: PM = to BC executions, drivers/controllers side (1) 4PM = to BP executions, drivers/controllers side (1) = to connector, cable side Fieldbus interfaces: Connector: M1 = from M1 output fieldbus connector, drivers/controllers side (1) = from connector, adapter side (1) for integral closed loop drivers/controllers series 40 6 E-SW / Z-SW MINIMUM PC REQUIREMENTS Personal Computer Pentium processor 1GHz or equivalent Memory 1 MB RAM + Hard Disk with 0MB free space Operating System Windows XP SP Device Dvd reader Monitor Resolution 104 x 768 Interface RS serial port (only for PS) or

7 E-SW / Z-SW SOFTWARE Valve's functional parameters can be easily set up with Atos E-SW / Z-SW programming software using proper connection to the digital driver/controller. E-SW / Z-SW software are available in different versions according to fieldbus interface and/or alternated P/Q control: Fieldbus : Drivers : SN Drivers with P/Q control (1): SP, SF, SL Controllers : SN, SP, SF, SL NP, PS, IR Not Present E-SW-PS E-SW-PS/S Z-SW-PS BC CANopen E-SW-BC E-SW-BC/S Z-SW-BC BP PROFIBUS DP E-SW-BP E-SW-BP/S Z-SW-BP EH EtherCAT E-SW-EH E-SW-EH/S Z-SW-EH Notes: (1) E-SW-*/S software support also SN drivers programming The software communication options (PS, BC, BP, EH) are not interchangeable and must be ordered separately. Fieldbus programming software can program digital electronics through: - RS Serial communication port for all versions of AES drivers and Z-ME-KZ controllers - communication port for all versions of integral closed loop drivers/controllers series 40 Basic programming software, free download : E-SW-PS web download = software can be downloaded upon web registration at www.download.atos.com; service and DVD not included Upon web registration user receive via email the Activation Code (software free license) and login data to access Atos Download Area. The software remains active for 10 days from the installation date and then it stops until the user inputs the Activation Code. Full programming software, to be ordered separately : E-SW-* / Z-SW-* DVD first supply = software has to be activated via web registration at www.download.atos.com; 1 year service included Upon web registration user receive via email the Activation Code (software license) and login data to access personal Atos Download Area. The software remains active for 10 days from the installation date and then it stops until the user inputs the Activation Code. E-SW-*-N / Z-SW-*-N DVD next supplies = only for supplies after the first; service not included, web registration not allowed Software has to be activated with Activation Code received upon first supply web registration DVD contents Include software installer, user manuals and fieldbus configuration files (EDS for BC, GSD for BP and XML for EH). Atos Download Area Direct access to latest releases of programming software, manuals, drivers and fieldbus configuration files at www.download.atos.com Software and drivers can be easily installed following the instruction contained in the info.txt files. An automatic mailing message will inform all the registered users whenever a new software upgrade is available. 8 FIRMWARE UPDATE It is possible to update the firmware of the following digital drivers and controllers using proper /Serial communication: Communication Type RS Serial Model Code E-RI-AES s0 E-RI-AEG s0 E-RI-AEZ s10 Z-ME-KZ-PS Note: for firmware update procedure, please contact Atos technical department E-RI-TEB s10 E-RI-LEB s10 E-RI-TES s40 E-RI-TES-S s40 Z-RI-TEZ s40 E-RI-PES-S s40 E-RI-LES s40 E-RI-LES-S s40 Z-RI-LEZ s40 9 SOFTWARE GRAPHIC INTERFACE - Examples BIAS & SCALE : numeric setting of bias and scale parameters allows to optimize the valve s hydraulic regulation; the graph shows the effect of your changes LINEARIZATION : linearization curve can be modified using the coordinates of the 10 available points; drag each point directly on the graph to modify the linearization setting DIAGNOSTIC : complete and comprehensive representation of actual valve s working conditions and alarms 10 CABLE CHARACTERISTCS E-C-SB-/M1-4m cables For connection of PC to proportional valves -ZO(R) with TEB/LEB drivers and integral drivers/controllers series 40. Connector to driver/controller side M1 - poles - male 1 +V_ - - - (1) - ID - - - (1) - GND_ GND_ 4 4 D - D - D+ D+ Connector side type A - male 4 1 Note: (1) do not connect GS00

11 ADAPTERS CHARACTERISTCS 11.1 E-A-SB-/OPT isolator adapter from PC to cables.0 Full speed (1 MBps) electrical isolation 1 kv temperature range, -40 +0 (relative humidity % 7%) external power supply not required (power 400 ma output, V ±10%) MTBF >1, million hours (MIL standard) type A, female to E-C-SB-/M1 0 mm type A, male port Model: ISO Full Speed - Brand: Electronics Shop 11. E-A-PS-/ adapter from PC to PS Serial cables male connector according to RS specification male connector, type A transmission rate from 1,6 kbit/s up to kbit/s 0,4 m 11. E-A-BC-/ adapter from PC to BC CANopen cables male connector according to the CiA specification DR0-1 male connector, type A transmission rate from 10 kbit/s to 1 Mbit/s LEDs indicate the actual working condition Model: iscan - Brand: ifak system m 11.4 E-A-BP-/ adapter from PC to BP PROFIBUS DP cables female connector according to the PROFIBUS RS48 specification male connector, type A transmission rate from 1,6 kbit/s to 1 Mbit/s LEDs indicate the actual working condition Model: ispro x1 - Brand: ifak system m 11. E-A-PS-/IR adapter from PC to E-MI-AS-IR drivers direct infrared communication with the driver male connector, type A plug-in format for direct connection on the driver transmission rate 9,6 kbit/s E-MI-AS-IR driver E-A-PS-/IR m 1 CROSS CABLES CHARACTERISTCS 1.1 E-C-PS-/M1-4 m cables For connection of E-A-PS- adapter to digital proportional valves -ZO(R) with integral PS drivers/controllers (AES, AEG, AEZ, TES s1, LES s1, PES, AERS, TERS, TEZ s10, LEZ s10) and AES drivers with fieldbus interface (BC, BP, EH). M1 - poles - female RS_TX PC_RX 4 RS_RX PC_TX RS_GND PC_GND - 9poles - female Connect the cable shield to the metallic housing of connector 1. E-C-PS-/M8-4m cables For connection of E-A-PS- adapter to Ex-proof digital proportional -ZA valves with integral PS drivers/controllers (AES, TES, LES AERS, TERS) and AES drivers with fieldbus interface (BC, BP). M8 - poles - female RS_TX PC_RX 1 RS_RX PC_TX 4 RS_GND PC_GND - 9poles - female 1. E-C-BC-/M1 - m cables For connection of E-A-BC- adapter to digital proportional valves -ZO(R) with integral BC drivers/controllers (AES, TES, LES, PES, AERS, TERS, TEZ, LEZ). M1 - poles - female CAN_L CAN_GND 1 CAN_SHLD (CABLE SHIELD) 4 CAN_H 7 CAN_V+ 9-9poles - female

1.4 E-C-BC-/RA - m cables For connection of E-A-BC- adapter to Ex-proof digital proportional valves -ZA with integral BC drivers (TES, LES, AERS, TERS). Driver side wires to driver terminal block brown CAN_L yellow CAN_GND shield CAN_SHLD (SHIELD) white CAN_H 7 green CAN_V+ 9-9poles - female 1. E-C-BP-/M1 - m cables For connection of E-A-BP-/ adapter to digital proportional valves -ZO(R) with integral BP drivers/controllers (AES, TES, LES, PES, AERS, TERS, TEZ, LEZ). M1 - poles - male reverse key CABLE SHIELD 1 - - - - 4 B_LINE - - - - A_LINE 8-9poles - male 1.6 E-C-BP-/RA - m cables For connection of E-A-BP-/ adapter to Ex-proof digital proportional valves -ZA with integral BP drivers (TES, LES, AERS, TERS). Driver side wires to driver terminal block shield CABLE SHIELD 1 - - - - red B_LINE - - - - green A_LINE 8-9poles - male 1.7 E-C-PS-/RJ4 -, m cables For connection of E-A-PS- adapter to digital E-BM-AS drivers. RJ4-8poles - male 6 RS_TX PC_RX RS_RX PC_TX 4 RS_GND PC_GND - 9poles - female Connect the cable shield to the metallic housing of connector 1.8 E-C-PS-/ - 4 m cables For connection of E-A-PS- adapter to digital Z-ME-KZ-PS controllers. Connector to controller side - 9poles - male RS_TX PC_RX RS_RX PC_TX RS_GND PC_GND - 9poles - female Connect the cable shield to the metallic housing of connector 1.9 E-C-BP-/ - m cables For connection of E-A-BP- adapter to digital Z-ME-KZ-PS/BP controllers. Connector to controller side - 9poles - male 1 CABLE-SHIELD 1 - - - - B_LINE - - - - 8 A_LINE 8-9poles - male 1 EtherCAT CABLE WIRING DIAGRAM Typical EtherCAT cable wiring diagram from industrial M1 connectors to standard RJ4 ethernet connectors. M1-4poles - male The cable shield can be connected to the metallic housing of M1 connector 1 TX+ white/orange 1 TX- orange RX+ white/green - - - - 4 RX- green 6 - - - - - Connector to EtherCAT network RJ4-8poles - male GS00

14 TERMINATORS CHARACTERISTICS The fieldbus terminators for CANopen and PROFIBUS DP are required when adapter has to be connected directly to the digital driver or output fieldbus connector has to be used as network end point. E-TRM-BC-/ CANopen terminator for E-A-BC-/ adapter 9poles - female CAN_SHLD CAN_GND CAN_L CAN_H CAN_V+ 7 9 11 ohm 7 9 CAN_SHLD CAN_GND CAN_L CAN_H CAN_V+ E-TRM-BP-/ PROFIBUS DP terminator for E-A-BP-/ adapter Cable side 9poles - male Terminator Terminator bus line terminator must be used adapter adapter 9poles - male SHIELD 1 + V 6 B_LINE A_LINE 8 GND 90 ohm 1 ohm 90 ohm 1 6 8 SHIELD + V B_LINE A_LINE GND Cable side 9poles - female bus line terminator must be used adapter E-TRM-BC-M1/PM network CANopen terminator M1 poles - male 1 4 10 ohm to fieldbus network (1) bus line terminator must not be used isolator adapter E-TRM-BP-M1/4PM network PROFIBUS DP terminator M1 4poles - male 1 4 90 ohm 1 ohm 90 ohm terminator connection example for drivers/controllers series 40 Note: (1) terminator must be connected to output fieldbus connector, refer to specific valve tech table fieldbus network 1 IR PS NP BC BP EH TOOLS SELECTION EXAMPLES Model Code Software Cable Adapter Terminator E-MI-AS-IR E-A-PS-/IR E-BM-AS-PS E-C-PS-/RJ4 E-SW-PS Ex-proof: AES, AERS, TERS, TES s1, LES s1 E-C-PS-/M8 AES, AEG, AEZ, AERS, TERS, TES s1, LES s1 TES/S s1, LES/S s1, PES s1 E-SW-PS/S E-C-PS-/M1 E-A-PS-/ TEZ s10, LEZ s10 Z-SW-PS Z-ME-KZ-PS E-C-PS-/ TEB, LEB E-SW-PS TES s40, LES s40 E-C-SB-/M1 E-A-SB-/OPT TES-S s40, LES-S s40, PES-S s40 E-SW-PS/S TEZ s40, LEZ s40 Z-SW-PS AES E-C-PS-/M1 Ex-proof: AES E-C-PS-/M8 E-A-PS-/ AERS, TERS, TES s1, LES s1 E-SW-BC E-C-BC-/M1 Ex-proof: AERS, TERS, TES s1, LES s1 E-C-BC-/RA E-A-BC-/ E-TRM-BC-/ TES s40, LES s40 E-C-SB-/M1 E-A-SB-/OPT TES/S s1, LES/S s1, PES s1 E-C-BC-/M1 E-A-BC-/ E-TRM-BC-/ E-SW-BC/S TES-S s40, LES-S s40, PES-S s40 E-C-SB-/M1 E-A-SB-/OPT TEZ s10, LEZ s10 E-C-BC-/M1 E-A-BC-/ E-TRM-BC-/ Z-SW-BC TEZ s40, LEZ s40 E-C-SB-/M1 E-A-SB-/OPT AES E-C-PS-/M1 Ex-proof: AES E-C-PS-/M8 E-A-PS-/ AERS, TERS, TES s1, LES s1 E-SW-BP E-C-BP-/M1 Ex-proof: AERS, TERS, TES s1, LES s1 E-C-BP-/RA E-A-BP-/ E-TRM-BP-/ TES s40, LES s40 E-C-SB-/M1 E-A-SB-/OPT TES/S s1, LES/S s1, PES s1 E-C-BP-/M1 E-A-BP-/ E-TRM-BP-/ E-SW-BP/S TES-S s40, LES-S s40, PES-S s40 E-C-SB-/M1 E-A-SB-/OPT TEZ s10, LEZ s10 E-C-BP-/M1 E-A-BP-/ E-TRM-BP-/ Z-ME-KZ-PS/BP Z-SW-BP E-C-PS-/ E-A-PS-/ TEZ s40, LEZ s40 E-C-SB-/M1 AES E-C-PS-/M1 E-A-PS-/ E-SW-EH TES s40, LES s40 TES-S s40, LES-S s40, PES-S s40 E-SW-EH/S E-C-SB-/M1 E-A-SB-/OPT TEZ s40, LEZ s40 Z-SW-EH 0/1