Micro Contactor MA Series

Similar documents
Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

3 Pole Contactors with AC operating coils

RUC industrial relays of small dimensions

Mini Contactors & Overloads

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions

TeSys contactors From 115 to 2750 A

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

WEG Contactors - CWM and CWME Series

IEC Power Control Contactors and Contactor Assemblies

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

TeSys IEC Contactors and Overload Relays

VZBs. Power PCB Relay RT2 2 pole 8 A, DC and AC-coil. Features. Contact data

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

K-Line Mini - Contactors, Overload Relays and Accessories

Contactors and Contactor Assemblies

RUC-M industrial relays for DC loads

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

CS8 Industrial Control Relays

194E FA 32 E P11 P11 6

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

R15 industrial relays of small dimensions

Bulletin 817 Thermistor Protection Relay

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets.

Disconnect Switches. Safe Switching and Disconnecting

CS7 Industrial Control Relays

Motor protection relays

Kuhnke Technical Data. Contact Details

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

Ultra Slim Relays 24

RM84 miniature relays

Jtec 10kA Miniature Circuit Breaker

CI-tronic Reversing contactor Type RCI

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Installation / Control Technique

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

Miniature PCB Relays A

RM4TR31 three-phase network control relay RM4-T - range V

Square D General Purpose Relays

Allen-Bradley 700-K40E-DJ

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

RM84 / RM85 / RM87 Miniature Electromagnetic Relays

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

Kuhnke Technical Data. Contact Details

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

Circuit Breakers Type CTI 25M, CTI 45MB

PRODUCT SPECIFICATION. PC Board Relays. Series.

UL 489 DIN Rail Miniature Circuit Breakers

194E FA 32 E P11 P11 6

RM4TA32 three-phase network control relay RM4-T - range V

CS7 Industrial Control Relays

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

UL 489 DIN Rail Miniature Circuit Breakers

SPST-NO SPDT DPST-NO DPDT

Solid State Remote Power Controller E /627

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Contact protection relay

RM699B miniature relays

Time Counters mini "h", DC Version

PI84 with socket GZM80 interface relays

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

Safety Systems Safety Integrated

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

MOTOR CONTROL. Mini-Contactors and Thermal Overload Relays. SK Series 62C1-E-0022

SIGUARD Safety Systems Safety Integrated

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

IEC Contactors. Auxiliary Contact Blocks GENERAL

E-STOP relays, safety gate monitors

K1B004TLH cam switch - 1 pole A - screw mounting

Power supply CP-C 24/5.0

78 Series Electromechanical Relay Selection Guide

Contactors and Contactor Assemblies

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Safety Relay H-464. Dimensions LxWxH(in mm) Size 3: 77,4 x20,5 x48,6 Size 4: 87,4 x20,5 x48,6

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

K1D012ULH cam changeover switch - 2-pole A - screw mounting

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

Control, Timing + Ice Cube Relays

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

Transcription:

Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC 5A AC3 @ 400VAC (2.2) - 12A AC1 @ 400VAC AC coil voltages - TS15 DIN rail mounting PCB mounting DC coil pending Micro Contactor Relays Page 2 Micro Contactors Page 3 Micro Contactors With Solder Pins Coil Voltages Page 4 Micro Reversing Contactor Page 5 Technical Data Dimensions Page 6 Page 10

Micro Contactor Relays 4-Pole Ratings Therm. Contacts * 2 Type Coil Voltage * 1 Distinc. Number Additional Contact 24 230 24V 50/60Hz 220-240V 50/60Hz AC15 Rated- Current 230V A 400V A I th A NO NC acc. to EN50011 Blocks Pack â Type pcs. Weight kg/pc. 4-Pole, With Screw Terminals 3 1.5 5 4-40E - MA04-S-40... 10 0.07 3 1.5 5 3 1 31E - MA04-S-31... 10 0.07 3 1.5 5 2 2 22E - MA04-S-22... 10 0.07 MA04-S-40 MA04-S-31 MA04-S-22 *1 Other coil voltages - see page 4 *2 Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Positively guided contacts. P2

Micro Contactors Power Ratings Rated Current Aux. Contacts *2 Built-in Additional Type Coil Voltage * 1 AC2, AC3 AC1 24 230 24V 50/60Hz 220-240V 50/60Hz 380V 400V 415V 660V 690V 440V A NO NC Type â Pack pcs. Weight kg/pc. 3-Pole, With Screw Terminals 2.2-12 1 - - MA05-S-10... 10 0.07 2.2-12 - 1 - MA05-S-01... 10 0.07 4-Pole, With Screw Terminals 2.2-12 - - - MA05-S-0040... 10 0.07 MA05-S-10 MA05-S-01 MA05-S-0040 Snap-On Adaptor For Type Specification Type Pack pcs. Weight kg/pc. MA for snap mounting of MA-P1039 10 0.01 Snap on Adaptor for MA accessories on 35mm DIN-Rail acc. DIN EN 50022 *1 Other coil voltages - see page 4 *2 Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Positively guided contacts. P3

Micro Contactors Power Ratings Rated Current Aux. Contacts *2 Built-in Additional Type Coil Voltage * 1 AC2, AC3 AC1 24 230 24V 50/60Hz 220-240V 50/60Hz 380V 400V 415V 660V 690V 440V A NO NC Type â Pack pcs. Weight kg/pc. 3-Pole, With Solder Pins Ø1.15 For Printed Circuit Applications 2.2-9 1 - - MA05-P-10... 10 0.07 2.2-9 - 1 - MA05-P-01... 10 0.07 4-Pole, With Solder Pins Ø1.15 for Printed Circuit Applications 2.2-9 - - - MA05-P-0040... 10 0.07 MA05-P-10 MA05-P-01 MA05-P-0040 Coil Voltages for AC operated contactors Suffix to contactor type e.g. MA05-S- 1024AC Voltage Marking at the coil for for Rated Control Voltage U s range for 50Hz for 60Hz 50Hz 60Hz min. max. min. max. V V V V V V 12 12 12 11 12 12 12 24 24 24 22 24 24 24 42 42 42 38.5 42 42 42 48 48 48 48 50 48 52 90 100 100 90 100 100 105 95 95-100 105-110 95 100 105 110 100 100 110-115 100 105 110 115 105 105-110 115-120 105 110 115 120 110 110-115 120-125 110 115 120 125 180 200 200 185 200 200 210 Suffix to contactor type e.g. MA05-S- 10230AC Voltage Marking at the coil for for Rated Control Voltage U s range for 50Hz for 60Hz 50Hz 60Hz min. max. min. max. V V V V V V 200 200 200-220 195 205 200 220 210 205-215 220-230 205 215 220 230 220 210-220 220-240 210 220 220 240 230 220-230 230-250 220 230 230 250 240 230-240 230 240 250 260 Standard voltages in bold type letters Operating range of magnet-coils: 0.85 x U S (min value of rated control voltage) up to 1.1 x U S (max value of rated control voltage) Coil not exchangeable *1 Other coil voltages - see above *2 Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Positively guided contacts. P4

Micro Reversing Contactors, Mechanical Interlock Power Ratings Rated Current Aux. Contacts *2 Built-in Additional on the left hand side contactor on right hand side contactor Type 24 230 Coil Voltage * 1 24V 50/60Hz 220-240V 50/60Hz AC2, AC3 AC1 380V 400V 415V 660V 690V 440V A NO NC K1 Type K2 Type â Pack pcs. Weight kg/pc. 3-Pole, With Screw Terminals 2.2-12 - 1 - - MA05-R-S-01... 1 0.14 2.2-12 1 - - - MA05-R-S-10... 1 0.14 4-Pole, With Screw Terminals 2.2-12 - - - - MA05-R-S-0040... 1 0.14 3-Pole, With Solder Pins Ø1.15 For Printed Circuit Applications 2.2 - xxx *3-1 - - MA05-R-P-01... 1 0.14 2.2 - xxx *3 1 - - - MA05-R-P-10... 1 0.14 MA05-R-S-01 MA05-R-S-10 MA05-R-S-0040 *1 Other coil voltages - see page 4 *2 Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Positively guided contacts. *3 Data available upon request P5

Data according to IEC 60947-4-1, VDE 0660, EN 60947-4-1 Main Contacts Type MA05-S.. MA05-P.. Rated insulation voltage U i V AC 440 *1 440 *1 Making capacity I eff at U e =440V AC A 65 65 Breaking capacity I eff cosφ = 0.65 400V AC A 50 50 Utilization category AC1 Switching of resistive load (=I th ) at 40 C, open A 12 9 Rated operational power of three-phase resistive loads 230V 4.7 3.5 50-60Hz, cosφ=1 240V 4.8 3.7 400V 8.3 3.3 415V 8.6 6.4 440V 9 6.8 (=I th ) at 60 C, enclosed A 8 6 Rated operational power of three-phase resistive loads 230V 3.1 2.3 50-60Hz, cosφ=1 240V 3.3 2.4 400V 5.5 4.1 415V 5.7 4.3 440V 6 4.5 Minimum cross-section of conductor at load with I e (=I th ) mm 2 1.5 - Utilization category AC2 and AC3 Switching is three phase motors 220V A 6.2 6.2 open and enclosed 230V A 6.2 6.2 240V A 5.6 5.6 380-400V A 5 5 415-440V A 5 5 480V A 5 5 Rated operational power of three-phase motors 220-240V 1.5 1.5 50-60Hz 380-440V 2.2 2.2 Utilization category AC4 Switching of squirrel cage motors, inching 220V A 4.9 4.9 open and enclosed 230V A 4.9 4.9 240V A 4.1 4.1 380-400V A 3.5 3.5 415-440V A 3.5 3.5 480V A 3.5 3.5 Rated operational power of three-phase motors 220-240V 1.1 1.1 50-60Hz 380-440V 1.5 1.5 Utilization category AC5a Switching of gas discharge lamps per pole at 220/230V Flourescent lamps uncompensated and serial compensated A 6 6 parallel compensated A 0.5 0.5 dual-connection A 9 9 Metal halide lamps* 2 uncompensated A 6 6 parallel compensated A 0.5 0.5 Mercury vapour lamps* 3 uncompensated A 9 9 parallel compensated A 0.5 0.5 Mixed light lamps* 4 A 9 9 LED-lamps consider the inrush current of the lamp ballast max. lamps per pole (I nled I th ) = inrush current of connector and cosφ of the lamp inrush current of lamp/evg max. inrush current of contactor A 91 91 Utilization category AC5b Switching of incandescent lamps* 5 per pole at 220/230V A 3 3 * 1 ) Suitable at 690V for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 4kV. Data for other conditions on request. * 2 ) Metal halide lamps and sodium-vapour lamps (high- and low-pressure lamps) * 3 ) High-pressure lamps * 4 ) Blended lamps, containing a mercury high-pressure unit and a tungsten helix in a flourescent glass bulb (daylight lamps) * 5 ) Current inrush approx. 16 x Ie P6

Data according to IEC 60947-4-1, VDE 0660, EN 60947-4-1 Main Contacts Type MA05-S.. Utilization category DC1 Switching of resistive load 1 pole 24V A 12 Time constant L/R 1ms 60V A 12 110V A - 220V A - 3 poles in series 24V A 12 60V A 12 110V A 12 220V A - Utilization category DC3 and DC5 Switching of shunt motors and series motors 1 pole 24V A 12 60V A - Time constant L/R 15ms 110V A - 220V A - 3 poles in series 24V A 12 60V A 12 110V A 12 220V A - Maximum ambient temperature Operation open C -40 to +60 (+90) *1 enclosed C -40 to +40 with thermal overload relay open C -25 to +60 enclosed C -25 to +40 Storage C -50 to +90 Short circuit protection for contactors without thermal overload relay Coordination-type 1 according to IEC 947-4-1 Contact welding without hazard of persons max. fuse size Coordination-type 2 according to IEC 947-4-1 Light contact welding accepted max. fuse size gl (gg) A 20 gl (gg) A - Contact welding not accepted max. fuse size gl (gg) A - For contactors with thermal overload relay the device with the smaller admissible backup fuse (contactor or thermal overload relay) determines the fuse size Cable cross-sections for contactors main connector solid or stranded mm 2 0.5-1.5 flexible mm 2 0.5-1.5 flexible with multicore cable end mm 2 0.5-1.5 Cables per clamp 2 solid or stranded AWG 20-14 Frequency of operation z without load 1/h 10000 contactors without thermal overload relay AC3 I e 1/h 600 AC4 I e 1/h 120 DC3 I e 1/h 600 Mechanical life AC operated S x 10 6 3 DC operated S x 10 6 xxx *2 Short time current 10s-current A 50 Power loss per pole at I e /AC3 400V W 0.2 Resistance to shock according to IEC 68-2-27 Shick time 20ms sine-wave AC operated NO g 2.5 NC g 2.5 *1 With reduced control voltage range 0.9 up to 1.0 x U s and with reduced rated current I e /AC1 according to I e /AC3 *2 Data on request P7

Data according to IEC 60947-5-1, VDE 0660, EN 60947-5-1 Auxilliary Contacts Type MA04-S.. MA05-S.. Rated insulation voltage U i VAC 440 *1 Thermal rated current I th bis 440V Ambient temperature 40 C A 5 60 C A 3 Power loss per pole I th W 0.25 Utilization category AC15 220-240V A 3 380-415V A 1.5 440V A 1 Utilization category DC13 60V A 0.5 - - Maximum ambient temperature Operation open C -40 bis to +60 (+90) *2 enclosed C -40 bis to +40 Storage C -40 bis to +90 Short circuit protection short circuit current 1kA, contact welding not accepted max fuse size gl (gg) A 10 For contactors with thermal overload relay the device with the smaller admissible control fuse (contactor or thermal overload relay) determines the fuse size Power consumption of coils AC operated inrush VA 9 sealed VA 4 W 1.8 Operation range of coils in multiples of control voltage U s 0.85-1.1 Switching time at control voltage U s ±10% *3*4 AC operated make time ms 13-18 release time ms 5-10 arc duration ms 10-15 DC operated make time ms - release time ms - arc duration ms - Cable cross-section all connectors solid mm 2 05-1.5 flexible mm 2 0.5-1.5 flexible with multicore cable end mm 2 0.5-1.5 Clamps per pole 2 solid or stranded AWG 20-14 *1 Suitable at 690V for: earthed-neutral systems, overvoltage category I to III, polution degree 3 (standard-industry): Uimp = 4kV Data for other conditions on request *2 With reduced control voltage range 0.9 up to 1.0 x U s and with reduced thermal rated current I th to I e /AC15 *3 Summary switching time = release time + arc duration *4 Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units) *5 Data on request P8

For North America - Data according UL508 Main Contacts (culus) Type MA05-S.. MA05-R-S.. Rated operational current General Use A 12 5 Rated operational power of three motors 110-120V hp ½ - at 60Hz (3ph) 200-208V hp 1-220-240V hp 1-277V hp 1½ Rated operational power of AC motors 110-120V hp ½6 - at 60Hz (1ph) 200-208V hp ½ - 220-240V hp ¾ Fuse / Short circuit current A/kA 30/5 - MA04-S.. Rated voltage VAC 300 300 Auxilliary contacts (culus) heavy pilot duty AC B300 B300 Standard pilot duty DC R300 R300 Motor Rating P n =AC4 380/ 220/ 400V 230V Motor Rating P n =AC3 380/ 220/ 400V 230V Breaking Current I a (=I e =AC1) A MA-05 Millions of Operations P9

Dimensions with screw terminals Snap-On Adaptor MA-P1039 MA04-S.. MA05-S.. Reversing Contactors with screw terminals MA..-S.. with Snap-On Adaptor MA-P1039 MA05-R-S.. with solder connections MA04-P.. MA05-P.. Reversing Contactors with solder connections MA05-R-S.. Mounting positions of contactors MA Ref: MAContactors15v2 Errors and omissions excepted. Subject to change without notice.