INSTALLATION INSTRUCTIONS

Similar documents
Spec Sheet. OmniReach FTTX Solutions DLX Fiber Optic Connector

OptiSheath MultiPort Terminal

White Paper. Re-enterable Plug and Play Fiber Access Terminals. ABSTRACT INTRODUCTION COMMON TYPES OF FIBER ACCESS TERMINALS

Miniature outside plant plug-and-play solutions. White paper

FTTX Solutions. Multiport Service Terminal (MST) and Hardened Drop Cables. Benefits:

OptiSheath Advantage Sealed 4-, 6-, 8- and 12-Port Multiport Terminals

FlexNAP Outside Plant System

FTTX SOLUTIONS. Multiport Service Terminal (MST) and Hardened Drop Cables BENEFITS:

MBE Mounts and Adapters

EVOLVE1-M MONITOR ARM

3 Angled Connector Housing (MC) Installation

Product Description. Features & Benefits. Multilink Inc All Rights Reserved. Removable Seal Window Opening:

Aerial. Pedestal. Outside Plant: Buried Fibre

Compact Series Wallmount Enclosures

NG3 High-Density Fiber Distribution Frame System Termination, Termination/Splice, VAM, and MPO Panels

FIBER OUTSIDE PLANT. Sealed & Aerial Splice Closures Fiber Demarcation Fiber Enclosures

OptiSheath Aerial Terminal, SCA-9T Series

ASSEMBLY AND ADJUSTMENT

FTTX Solutions Outdoor FDH PRODUCT CATALOG 2ND EDITION

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

Rack Mount Cabinet with Fiber Mgmt System, accepts up to 3 Adapter Plates. Rack Mount Cabinet with Fiber Mgmt System, accepts up to 6 Adapter Plates

Clearview Cassette. Clearview Blue

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR SIMPLEX OPTICAL FIBER (MULTIMODE) NO-EPOXY, NO-POLISH CONNECTORS

SlimBox Drop System A FOX Solution Component Set

Extra Large Full Motion TV Mount for Televisions

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C)

Section 15 Cable Demarcation Enclosure

ARIADROP: Fiber to the MDU (FTTM)

Vacuum Maintenance Manual (EXCERPT Tim Benedict)

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Part Name/Description Part Number Quantity

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

FDH Sealed Fiber Distribution Hub. Features and Benefits

Outdoor FDH Termination Pole-Mount Cabinet With Universal Splitter Chassis User Manual

Titan Media Cart. Installation and Operation Manual

Fiber-to-the-Home (FTTH) Pedestal

ReachFree ID Installation Instructions for Wash Select II. Unitec

Flat Panel Static Wall Mount MSP-SS (GSM-210)

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

Indoor Protected Entrance Terminal 4588 Series

Star Trac Fitness E-ST 5090 Stepper. Install Guide

Section 28 Fiber Optics: Fiber Distribution Cabinets and Accessories

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

Pretium Rack-mountable 1U Housing Hardware

Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction

Assembly Instructions Triton Enclosure for Poseidon With Data Acquisition November, 2007 V0.9 DSC Document #

AlphaGateway SMG-01PE Quick Start Guide

DirectCommand Installation DirectCommand Complete Wiring Harness

serial number A1159T or lower, which includes all manufactured in 2008 Not compatible and not required. Figure 1 Auger Update Sites Call-Outs R B

LARGE S URGE-PROTECTOR S HELTER

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

Cab Box Kit Dome Plug Cab Box Cab Box Lid

Raven Adapter Harness

Aerial Weathertight Fiber Optic Splice Closures FSCO-AS

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Next Generation Frame - Black (NGFB) Optical Distribution Frame Solution

If you are missing any of the following items, please contact Stanton Video immediately (602)

Parts and Service Manual IMCO

features and benefits: dimensions: Hardware Shipping additional information: Graphic Material: Dye-sublimated fabric Tabletop color options:

Peel/Rewind Upgrade Kit

HD Flex Zero RU Cassette Holder and Bracket

DOG ULTRA LOW LIGHT LONG RANGE FIXED CAMERA USER MANUAL

FL1000 Wall-Mount Box Installation and Operation Guide

PAR+ & MSC+ Controller. Installation Manual

3M Fiber Dome Terminal Closures FDTC 08M and FDTC 08S External Drop Termination

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

DirectCommand Installation Hardi Spray Box II 39-pin Kit. Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 16

DirectCommand Installation Case/Flexi-Coil/New Holland Air Cart Kit (Variable Rate Electro Hydraulic Systems) Ag Leader Technology

CLIMB2 DUAL MONITOR SIT/STAND WORKSTATION

- Optical FAQ Highway 108 Sierra Village, CA Telephone: (800) Fax: (209) Optical Connectors:

Model No. ET-JPF200BE

Part Name/Description Part Number Quantity

Setup Information Panosaurus May 3, 2011

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

Mounting Accessory Guide

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

Full HD Speed Dome IP Camera

Datasheet. Fiber Optic Modular Patch Panel Features

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

3M Fiber Distribution Units 8400 Series

Ag Leader Technology. DirectCommand Installation RoGator Model Years

SCHNEIDER OPTICS INC. DISTAR PROJECTOR LENS W/ FOCUS MOUNT INSTRUCTION MANUAL

FTTX Fiber Optic Cabinet Packages Priority Electronics USA

FOSC 400 Closures and Accessories 2015 ORDERING GUIDE 1ST EDITION

2 Wire Digital Phone Fiber Link Card System

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

ASSEMBLY INSTRUCTIONS. 8 Element 10/11 Meter Maximum Beam M108C

Formulate Kiosk features and benefits: dimensions: additional information:

Fiber Management Tray (FMT) User Manual

3M Fiber Distribution Units 8400 Series. The Network of Networks. Flexibility for. Networks. Growing

FieldShield YOURx Platform:

DirectCommand Installation CASE IH SPX Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 19

Formulate Designer Series 20 Backwall - Kit 11

Reduces installation time Locks tray into position - no hardware required

Utility FTTx Solutions

Formulate 20 x 20 Island Exhibit - Kit 10

ASSEMBLY ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS

Transcription:

AFL TITAN RTD Multiport Terminal AFL TRIDENT Hardened Drop TABLE OF CONTENTS GENERAL... 2 SPECIFICATIONS... 2 PACKAGE CONTENTS... 3 REQUIRED TOOLS... 3 ADD-ON COMPONENTS... 3 TERMINAL MOUNTING STRAND... 4 TERMINAL MOUNTING WALL OR POLE... 5 TERMINAL MOUNTING HANDHOLE OR PEDESTAL... 5 CONNECT AFL TRIDENT HARDENED CONNECTOR... 6 1

GENERAL The AFL TITAN RTD Multiport Terminal is a factory terminated OSP fiber terminal designed for quick and easy subscriber connections anywhere in the OSP network when used in conjunction with AFL TRIDENT Hardened Connectors. The sealed and rugged design of both the AFL TITAN RTD Multiport Terminal and AFL TRIDENT Hardened Connectors allow for longterm reliability when installed anywhere in the network underground, in pedestals, on poles or on aerial strand or ADSS cables. The preterminated AFL TITAN RTD Multiport Terminal is available with dielectric or toneable flat drop cable stubs, allowing for flexibility when engineering the network and consolidation of multiple terminal stubs into one centralized splice point. The terminal is outfitted with four, six, eight or twelve AFL TRIDENT Hardened Connector ports. The AFL TITAN RTD Multiport Terminal and AFL TRIDENT Hardened Connector are designed and tested to Telcordia GR-771 and Telcordia GR-3120, respectively. Lengths 350 feet ship coiled in low-profile boxes. Lengths >350 feet ship on a 33" corrugated plastic reel inside a cardboard box. MULTIPORT TERMINAL SPECIFICATIONS Parameter Dimensions - (L x W x H) in. (mm) Packaging Dimensions (L x W x H) in. (mm) Weight lbs (kg) Maximum Span Length at 1% Sag - ft (m) at 60 F Installation per NECS loading conditions Maximum Tensile Loading - lbs (N) Value 4- and 6-port 12.4 x 4.9 x 3.0 (315 x 125 x 76) 8- and 12-port 15.5 x 6.1 x 3.8 (394 x 195 x 96) 350 feet (box) 25.0 x 25.0 x 7.0 (635 x 635 x 179) 350 feet (reel) 33.0 x 25.0 x 9.0 (838 x 635 x 838) 4- and 6-port 1.5 (0.7) 8- and 12-port 2.5 (1.1) Light Loading - 550 (167) Medium Loading - 275 (84) Heavy Loading - 150 (45) Install - 300 (1,335) Long Term - 90 (405) Minimum Dimension Bend Radius - in (mm) 3.19 (81) 2

AFL TRIDENT HARDENED CONNECTOR SPECIFICATIONS Parameter Insertion Loss, Maximum Insertion Loss, Typical Reflection Operating Temperature Value 0.50 db 0.15 db -65 db -40 C to +75 C Retention Force 25 lbs (111 N) Dust Cap Pulling Eye Tension 100 lbs (444 N) PACKAGE CONTENTS AFL TITAN RTD Multiport Terminal REQUIRED TOOLS One-Click SC Cleaner ADD-ON COMPONENTS Strand Mount Bracket Kit Adjustable Strand Mount Bracket Kit AFL TRIDENT Hardened Connector to SC/APC Adapter AFL TRIDENT Hardened Connector to SC/APC Jumper AFL TRIDENT Hardened Connector to SC/UPC Jumper AFL TRIDENT Hardened Connector OTDR Fiber Ring 3

MULTIPORT TERMINAL MOUNTING OPTIONS Caution: Fiber optic cable is susceptible to damage from excessive bending, pulling or crushing forces. At every stage of the installation process ensure that cables are free from unintentional cuts, knicks or bends to avoid potential fiber damage. Pem-nut Flat Washer Lock Washer Bolt MULTIPORT TERMINAL MOUNTING - STRAND 1. Using local engineering practices, determine the installation location for the multiport terminal. 2. Align the pem-nut hole on the strand mount bracket with the terminal mounting hole. 3. Secure the strand mount bracket to the terminal using the bolt and washers provided in the Strand Mount Bracket Kit. (Figure 1a and 1b) Note: For best practice, it is recommended that both strand mount brackets be installed onto the terminal before beginning the strand mount procedure. 4. Determine the size of the strand and loosen the strand clamp. Do not remove this bolt from the strand mount bracket. 5. Place both strand mount bracket clamps over the strand and tighten completely. (Figure 2) Note: For best practice, it is recommended that the multiport terminal be mounted on the strand with the adapter ports oriented towards the pole. Figure 1a Figure 1b Figure 2 For applications that require the multiport terminal be mounted on large overlash bundles the Adjustable Strand Mount Bracket Kit will be utilized. 1. Determine the necessary height for the bracket. 2. Using a standard 216 style tool, or similar, to loosen the bolt allowing the bracket to expand to the desired height. (Figure 3a and 3b) 3. Re-tighten the bolt locking the bracket into place. 4. Follow steps 1 5 of the MULTIPORT TERMINAL MOUNTING STRAND section to complete the Adjustable Strand Mount Bracket installation. Figure 3a Figure 3b 4

MULTIPORT TERMINAL MOUNTING WALL OR POLE 1. Using local engineering practices, determine the installation location for the multiport terminal. 2. Using local accepted practices and approved hardware, secure the bottom of the terminal to the wall or pole. 3. Using the same hardware, secure the top of the terminal to the wall or pole. (Figure 4a and 4b) Figure 4a Note: When mounting to a metal or concrete pole, the top and bottom mounting tabs of the multiport terminal are designed to accept a ¾" band. (Figure 4c) MULTIPORT TERMINAL MOUNTING HANDHOLE OR PEDESTAL 1. Using local engineering practices, determine the installation location for the multiport terminal. 2. Align the terminal mounting holes with the mounting holes on the pedestal back plate or vertical mounting channel. 3. Using local accepted practices and approved hardware, secure the bottom of the terminal to the back plate or channel. 4. Using the same hardware, secure the top of the terminal back plate or channel. (Figure 5a and 5b) Note: For best practice, it is recommended that the hardware sizes below be used in the following order: * 1/4-20 Bolt * 1/4ʺ Lock Washer * 1/4ʺ Flat Washer * 1/4ʺ Locking Nut Figure 4b Figure 4c Figure 5a Figure 5b 5

CONNECT AFL TRIDENT HARDENED CONNECTOR Caution: When working with fiber optics, do not look directly into the end of the fiber cable or adapter port. A power meter may be used to determine if the cable or port is dark. Or use locally accepted fiber optic saftey practices. Note: When adding a AFL TRIDENT Hardened Connector cable assembly to a terminal that was previously placed ensure that the multiport terminal is clear from any environmental debris before removing the adapter cap. When cleaning the terminal only clean water is to be used. Caution: Fiber optic cable is susceptible to damage from excessive bending, pulling or crushing forces. At every stage of the installation process ensure that cables are free from unintentional cuts, knicks or bends to avoid potential fiber damage. 1. Using local engineering practices, determine the terminal port to be used for connecting with the AFL TRIDENT Hardened Connector cable assembly. Note: Each port on the terminal is identifiable by an embossed port ID located above each adapter. 2. From the multiport terminal, remove the adapter cap and insert One-Click SC Cleaner into the ceramic cylinder to clean the port. (Figure 6a and 6b) Note: The adapter cap should only be removed immediately prior to connection in order to avoid any contamination. Figure 6a Figure 6b Figure 6b 6

INSTALLATION INSTRUCTIONS AFL TITAN RTD FTTx System 3. From the AFL TRIDENT Hardened Connector, remove the connector cap and use One-Click SC Cleaner to clean the connector endface. (Figure 7a and 7b) 4. Align the key on the connector with the key on the adapter. The connector and adapter keys are indicated with white markings. (Figure 8a and 8b) 5. Insert the connector, press down and give a quarter turn to the right to engage. The connector will be fully engaged when the longer white marking is aligned with the white mark on the TITAN adapter. (Figure 9) Figure 8a Note: Connector should be installed hand tight. DO NOT use pliers of other tools to engage the connector which may damage the connector and/ or adapter if overtightened. 6. Screw the multiport terminal adapter cap into the AFL TRIDENT Hardened Connector dust cap to prevent contamination on either the connector or adapter dust cap should the drop ever be removed and the dust caps reused. (Figure 10a and 10b) Figure 8b 7. Repeat steps 1-6 for each AFL TRIDENT Hardened Connector cable assembly to be installed into the terminal. Figure 7a Figure 9 Figure 10a Figure 7b Figure 10b 7