UL2930 Healthcare Facility Outlet Assemblies UL1449 Heavy Duty Surge Protection Devices. Wiring Device-Kellems

Similar documents
File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

SmartPro 120V 1kVA 750W Medical-Grade Line- Interactive Tower UPS with 4 Outlets, Full Isolation, USB, Lithium Battery

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

Innovative Technology line filters and surge protectors

SNAPConnect Devices. Savings and Productivity Are Just a SNAP Away. Hospital Grade. Specification Grade Receptacles. Split Circuit

MIL STD 220a (50 Ohm) Model Ordering: 400LS - 277Y - DS - UFP - MX

Protect It! 8-Outlet Industrial Safety Surge Protector, 25-ft. Cord, 3900 Joules, Cord Wrap, Hang Holes

Surge Protective Devices. STV25K Series. Instruction Manual

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

White Paper October 2009

Isobar UL 1363 Hospital-Grade 6-Outlet Surge Protector, 15 ft. Cord, 3330 Joules, LEDs, Not For Patient-Care Vicinities

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

Emery County Senior Center Green River 06/07

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

SmartPro UPS System Intelligent line interactive medical-grade battery backup and network power management

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

SNAPConnect. Savings and Productivity Are Just a SNAP Away

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Grid to Chip Surge Protection Product Catalog

EMOSAFE EN-30 1 FEATURES AND ADVANTAGES 2 GENERAL DESCRIPTION. Product Datasheet. Gigabit Network Isolator in aluminium housing December 2015 ENGLISH

UL TEST REPORT AND PROCEDURE

glossary GE Digital Energy Power Quality Surge Protective Devices (SPDs)

TECH NOTE #: CPS-1 SUMMARY OF APPLICABLE UL AND IEEE STANDARDS

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

High Performance Network Isolator

Surge Protectors and Digital Timer

EMOSAFE EN-100 Network Isolators for PCB assembly

SECTION N. Table of Contents. Wiring Device-Kellems. SpikeShield Surge Protection Plug Strips

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Surg Sur e P ot r ection

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Safety Standards. Model Number:

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

Specifications, Installation, and Operating Instructions

Isobar Surge Suppressors by Tripp-Lite (Most Popular Models)

7-Outlet Home/Business Theater Surge Protector, 6-ft. Cord, 2100 Joules, Tel/Modem/Coax Protection

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

UL TEST REPORT AND PROCEDURE

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

OmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer

BSPD Surge Protective Devices

Eaton s SPD Series for integration into electrical distribution equipment

A Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Product Specifications

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

EMOSAFE EN-85e Network Isolator with Overtension Auto-Release

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input with Loop Power 7B35

Surge Protection for Surveillance Systems

Safety Standards. Model Number:

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

EMOSAFE EN-10 Network Isolators with Protected Connector

Output Voltage* (nom.)(adjustable)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

Safety Standards. Model Number: Unit Weight:

* * Agilent Power Distribution Unit (PDU) Installation Guide

Description GFCI HG ST DUPLEX 20A 125V BR Long Description GFCI HG ST Duplex 20A 125V BR

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Haworth Power Technical Sheets January 2018

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

SECTION SURGE PROTECTIVE DEVICES

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

With the exception of EN-70e, which provides a dielectric strength of only 4.6 kv AC, and does not provide any transient voltage suppression.

MICHIGAN DEPARTMENT OF TRANSPORTATION

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Tel/Coax/Modem, Metal

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

A Complete Floor Box System for Concrete

Fall Test 21 due 12/11/2012

Recp HG Ig SGL 20A 125V 2P3W STR B&S or

Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing

Automatic Receptacle Control Product Guide

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

Safety Standards. Model Number:

Surge Protection (TVSS)

Transcription:

UL2930 Healthcare Facility Outlet Assemblies UL1449 Heavy Duty Surge Protection Devices Wiring Device-Kellems Industrial Surge Protection Healthcare

Wiring Device-Kellems Healthcare Facility Outlet Assemblies (HCOA) UL2930 Listed UL2930 Listed Green LED indicates surge protection working 12/3 SJT and Models Hubbell HCOA: First UL2930 Product Ever Sold and Versions 6 ft. or 15 ft. Cord #12/3 AWG Cord Surge Protected Models in all Configurations Non-Surge Protected RPT Models in all configurations Tamper-Resistant Flip covers HBL6MGRPT620 RPT HCOA HBL6MG620 Surge Protected HCOA Ground Terminal 45 Angle Plug ( only) UL2930 Health Care Outlet Assembly (HCOA) Description # of Outlets Cord Color 15 Amp 20 Amp UL 2930 HCOA 6 6 Ft. White HBL6MG6 HBL6MG620 with L-N Surge Protection 6 15 Ft. White HBL6MG15 HBL6MG1520 UL 2930 HCOA Relocatable Power Tap (RPT) 6 6 Ft. White HBL6MGRPT6 HBL6MGRPT620 6 15 Ft. White HBL6MGRPT15 HBL6MGRPT1520 UL2930 HCOA Specifications Electrical Specifications Current Voltage Frequency Surge Component Performance UL VPR L-N L-G, N-G EMI Noise Filtration: In (Nominal Discharge Current) MCOV Peak Current Rating L-N Leakage Current: Total Joules (L-N) Environmental Specifications Operating Temperature HBL6MG6/15 HBL6MG20/1520 HBL6MGRPT6/15 HBL6MGRPT20/1520 600V -11 db to -68 db (10kHz to 100MHZ) 3kA 150V 30KA <.1mA 550j -40⁰F to 160⁰F (-40⁰C to 70⁰C) Certifications UL 2930; UL File # E488399; RoHs Compliant; NFPA 99 2012 ed; ANSI / IEEE Category A (HBL6MG Series Only) Physical Specifications Cord Color Receptacles Plug: LED (HBL6MG Series only) Dimensions HBL6MG Series: HBL6MGRPT Series: 12/3 SJT 18G Galvanized Steel White Powder Coat HG Tamper Resistant HG 45⁰ Angle HG 90⁰ Angle Green Power Indicator 16.02" (406.9mm) 1.92" (48.8mm) 12.72" (323.1mm) 1.92" (48.8mm)

Heavy Duty SpikeShield Surge Protection for Industrial and Healthcare Applications Healthcare Industry: Hospital Grade Tamper-Resistant Receptacles with a Hospital Grade Plug culus 1449 4th Edition Heavy Duty Metal Available with a 2-Port USB Charging Outlet Wiring Device-Kellems Listed to UL1449 Industrial Grade: Tamper-Resistant Receptacles with a Heavy Duty Plug culus Listed to UL1449 4th Edition Heavy Duty Metal SpikeShield Surge Protective Devices (SPD) with Hospital Grade Tamper-Resistant Receptacles and Hospital Grade Plug Description # of Outlets Cord Color 15 Amp 20 Amp Type 3 SPD, Heavy Duty Metal 6 6 Ft. White HBL6HG6 HBL6HG620 6 15 Ft. White HBL6HG15 HBL6HG1520 UL Type 3 SPD, Heavy Duty 4 Metal with 2-port USB 6 Ft. White HBL6HGUSB6 SpikeShield Surge Protective Devices (SPD) with Industrial Grade Tamper-Resistant Receptacles and Heavy Duty Plug Description # of Outlets Cord Color 15 Amp 20 Amp Type 3 SPD, Heavy Duty Metal 6 6 Ft. White HBL6SS6 HBL6SS620 6 15 Ft. White HBL6SS15 HBL6SS1520 SpikeShield SPD Specifications 15 Amp HBL6SS/HBL6HG Series mp HBL6SS/HBL6HG Series Electrical Specifications Current Voltage Frequency Surge Component Over Current Protection CB CB 2-Port USB (HBL6HGUSB6) 5V DC Type A UL VPR L-N L-G N-G 500V 600V 600V MCOV 150V Peak Current Rating L-N 30KA Leakage Current: <.5mA EMI / RFI Noise Rejection -11 db to -68 db (10kHz to 100MHZ) Total Joules (all modes) 1100j Environmental Specifications Operating Temperature -40⁰F to 160⁰F (-40⁰C to 70⁰C) Certifications culus Listed to UL1449 4th Edition UL File # E143272 RoHs Compliant NFPA 99 2012 ed ANSI / IEEE Category A culus Listed to UL1310 (2-Port USB) Physical Specifications HBLH6USB6: 15.67" (398.0mm) 1.78" (45.2mm) HBL6HG Series: HBL6SS Series: 14.42" (366.3mm) 1.70" (43.3mm)

UL 2930 Healthcare Outlet Assemblies (HCOA) The follow excerpt was copied from the Underwriters Laboratories website and can be found at: https://standardscatalog.ul.com/standards/en/outline_2930_1 UL 2930, Outline of Investigation for Cord-and-Plug-Connected Health Care Facility Outlet Assemblies 1 Scope 1.1 These requirements cover indoor-use cord-and-plug-connected Health Care Facility receptacle outlet assemblies (HCOA) rated 250 V AC or less and 20 Amperes or less. HCOA are for use as a movable power supply connection for cord-and-plug-connected medical electrical utilization equipment in accordance with the National Electric Code, NFPA 70, Article 517 Health Care Facilities, and with NFPA 99, Health Care Facilities Code, for use in Category 2 (General Patient Care) Spaces or Category 1 (Critical Patient Care) Spaces, including Patient Care Vicinities equipped with Patient Equipment Grounding Points. 1.2 HCOAs are intended for use with equipment complying with applicable requirements of the: a) Standard for Medical Electrical Equipment, Part 1: General Requirements, UL 60601-1; b) Medical electrical equipment Part 1: General requirements for basic safety and essential performance, IEC 60601-1; and c) Medical Electrical Equipment Part 1-2: General Requirements for basic safety and essential performance Collateral standard: Electromagnetic disturbances Requirements and tests, ANSI/AAMI 60601-1-2. 1.3 These requirements cover HCOA consisting of an ANSI/NEMA WD 6-configuration Hospital Grade attachment plug and a length of non-detachable flexible cord terminated in an enclosure in which are mounted ANSI/NEMA WD 6-configuration Hospital Grade individual receptacle outlets (duplex or single) which are connected conductively to an integral patient equipment grounding terminal or jack provided for user connection of a discrete grounding path conductor to Patient Equipment Grounding Points, installed in the Patient Care Vicinities of a Health Care Facility. 1.4 An HCOA is not intended for Home Health Care Use. 1.5 These requirements do not cover cord-connected, Relocatable Power Taps (RPT) intended only for indoor use as a temporary extension of a grounding alternating-current branch circuit for general use, covered by the Standard for Relocatable Power Taps, UL 1363. RPT are not suitable for use in Category 2 (General Patient Care) Spaces or Category 1 (Critical Patient Care) Spaces or Patient Care Vicinities. 1.6 These requirements do not cover cord-connected, Special Purpose Relocatable Power Taps (SPRPT); covered by the Outline of Investigation for Special Purpose Relocatable Power Taps, UL 1363A. SPRPT are power distribution components intended to supply power to plug-connected components of a movable equipment assemblies that are rack, table, or pedestal-mounted. SPRPT are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The SPRPT shall be an integral part of the equipment assembly and permanently attached to the equipment assembly only by those qualified to assemble medical electrical equipment systems compliant with Medical electrical equipment Part 1: General requirements for basic safety and essential performance, IEC 60601-1. SPRPT are not suitable for use in Patient Care Vicinities. 1.7 These requirements do not cover cord-connected, Furniture Power Distribution Units (FPDU), intended for indoor use that provide power for and are intended to be installed in furnishings. FPDU are covered by the Standard for Furniture Power Distribution Units, UL 962A. www.hubbell-wiring.com Hubbell Wiring Systems Hubbell Incorporated (Delaware) 40 Waterview Drive Shelton, CT 06484 Phone (800) 288-6000 FAX (800) 255-1031 Printed in U.S.A. Specifications subject to change without notice. WLBPQ004 2/17

Sager Electronics is an authorized distributor of Hubbell and UL2930 Healthcare Facility Outlet Assemblies. Contact a Sager sales representative at 1.800.SAGER.800 or customerservice@sager.com for price and availability. Sager Electronics, the authorized distributor for Hubbell 1.800.SAGER.800 www.sager.com