Mag-01H. Fluxgate Declinometer/Inclinometer. Mag-01H D/I. World leaders in high precision magnetic field measurements

Similar documents
INNOVATION IN MAGNETICS DS0070/12. Mag-01H D/I. Declinometer/Inclinometer System.

Innovation in Magnetic Measuring Instruments. Data Acquisition & Conditioning Units

INNOVATION IN MAGNETICS DS0013/27. Mag-03. Three-Axis Magnetic Field Sensors.

Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys. For innovation in magnetic measuring instruments

Mag-03. Three-axis Magnetic Field Sensors. For innovation in magnetic measuring instruments

Data Acquisition & Signal Conditioning Units

Innovation in Magnetic Field Measuring Instruments. Mag648 & Mag649. Low Power Three-Axis Magnetic Field Sensors.

HCS1 Three-Axis Helmholtz Coil System

Innovation in Magnetic Field Measuring Instruments. Grad601. Magnetic Gradiometer System

Mag-03. Three-Axis Magnetic Field Sensors.

Innovation in Magnetic Field Measuring Instruments. Mag-03. Three-Axis Magnetic Field Sensors.

Spacemag & Spacemag-Lite

Innovation in Magnetic Measuring Instruments. Mag-03. Three-Axis Magnetic Field Sensors

INNOVATION IN MAGNETICS DS-2201/8 DAS1. Data Acquisition System.

Operation Manual for. Mag-01 & Mag-01H Single Axis Fluxgate Magnetometers with Mag Probes B-G

Operation Manual for Mag612 Three-Axis Magnetic Field Probe

Mag High Temperature Three-Axis Magnetic Field Probes

Product Identification Product name Package Noise* Range in µt Mag-03 MC= Cylindrical B = Basic ±70 MCES = Cylindrical, environmentally sealed to IP64

Handheld Gaussmeter Gaussmeter

Operation Manual for. Mag628/629 and Mag669 Three-Axis Aerospace Magnetometers.

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

FDU108 Fluxgate Sensor Data Acquisition Unit

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

TEL: / FAX:

from P.R.Engineering Ltd Tel:

Thermometer T12. Precision Multichannel Thermometer System. Typical applications: REFLECTING YOUR STANDARDS

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

CAEL-DP Series Dew Point Transmitter for Industrial Control

SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE

E D I T I O N PRODUCT LIST SURVEY PRODUCTS LTD

Operation Manual for. Geolabsoft for Windows (PC version)

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Gas detection just got personal

Magnetic Field Measurement Products

Accsense Wireless System. Temperature Monitor

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Temperature Measurement

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated Process Current Input with Loop Power 7B35

DEFECTOMETER High detection sensitivity to surface flaws (even underneath paint) Simple, microprocessor-controlled operation

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Optimum sensing capability for LCD manufacturing

AC-43 Accelerometer. User Manual

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MODEL 9250 Preliminary data sheet

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Standard reference resistor Model CER6000

PTU300 Combined Pressure, Humidity and Temperature Transmitter

DMI600 - Dual-Axis Digital Display Inclinometer

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

DINALOG A 144 x 36 A1400 Light-Strip Indicator

9200, Seismoprobe* Velocity Transducers

Mini position indicator

Hand-held thermometer Model CTH7000

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

Supply Voltage V dc Supply is fully isolated internally, and protected against transients. Internal power modules are CE certified.

Electronic SD1, AS 8, ASR 14, ASR 20

IST ULTRASTAB Power Supply for high precision transducers

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

ED-1100 PORTABLE VARIABLE EDDY CURRENT INSTRUMENT

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Inclination sensors 2-dimensional, measuring range up to ±90

AGATE TECHNOLOGY AT-2030 OPERATORS MANUAL

Rugged and waterproof, plus high-power telescope with superior Nikon optics

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Level-Lance Model 5400A

Paramount Robotic Telescope Mount Specifications

Photoelectric Sensors E3F2

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

E101 - Strain Gauge Transducer Display Module. Contents

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations

Precision thermometer Model CTR2000

WARNING & SAFETY PRODUCTS

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532

TOXALERT MODEL AIR 2000

GE Industrial Sensing. Druck DPI 104. Digital pressure indicator User manual - K394

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

Laserlyte Alignment System

Handout. and. brief description. Marine Gravity Meter KSS 32- M

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

German Cathodic Protection

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Korry 1380 high-performance switch with oversized display for master caution and warning systems

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Measurement microphone. MI series

Machine Vision Lyte-MV

Power Amplifiers for PVH-EDC Pumps

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

Mag-01H D/I World leaders in high precision magnetic field measurements Mag-01H Fluxgate Declinometer/Inclinometer Distributed By: GMW Associates 955 Industrial Road, San Carlos, CA, 94070 USA PHONE: +1 650-802-8292 FAX: +1 650-802-8298 EMAIL: sales@gmw.com WEB: www.gmw.com

Mag-01H Fluxgate Declinometer/Inclinometer The Mag-01H Declinometer/Inclinometer system comprises a single axis fluxgate magnetometer (type Mag-01H), a fluxgate probe (type Mag A) and a WILD T1 steel-free theodolite. A steel-free tripod is available if required. The WILD T1 micrometer theodolite has a resolution of 6 seconds (can be estimated to 3 seconds). A brochure for the WILD T1 theodolite is available on request. Each pre-used WILD T1 theodolite is meticulously converted to be steel-free and restored as far as possible to its original condition. After conversion, each theodolite is rigorously checked for magnetic hygiene and is guaranteed to be non-magnetic. The initial set-up procedure includes checking the magnetic cleanliness of the theodolite at each stage of assembly. The optical/magnetic collimation error is set to less than 20 seconds. On request, the Mag-01H Declinometer/Inclinometer can be checked against a reference system at a magnetic observatory for an additional charge. The Mag-01H and Mag Probe A can be mounted on the customer s theodolite. We can provide a mounting adaptor for the WILD T1, Zeiss (010, 015 and 020 A or B) and Yom theodolites. Under these conditions, we cannot guarantee the magnetic cleanliness of the theodolite or the results produced by the instrument. Measurements of declination and inclination This system provides fast, accurate and convenient measurements of the declination and inclination of the geomagnetic field. The excellent linearity allows the total field strength and the vertical (inclination) and horizontal (declination) components to be measured. The declination (D) and inclination (I) of the geomagnetic field are two important parameters that vary with time. Magnetic observatories worldwide perform measurements of the geomagnetic field. However, to calibrate the instrument used, a precise instrument must be deployed to determine, on a regular basis, the declination and inclination of the field. This can be achieved using the precise Mag-01H D/I system. The system can also be employed as a calibration tool for compass and magnetic ranges. The Mag-01H D/I system is useful in oil and gas exploration, when directional drilling is involved. This technique uses magnetometers to monitor the direction of the drilling head. To avoid errors caused by local variations of the declination and inclination, mostly owing to the local geology, precise measurements of declination and inclination are required, and can be obtained by performing a survey using the Mag-01H D/I system. When performing measurements of declination and inclination, the measurement resolution is limited by the prevailing geomagnetic conditions, the skill of the operator and the mechanical stability of the tripod, if used. www.bartington.com

Mag-01H Single Axis Fluxgate Magnetometer This battery powered instrument provides the drive for the probe and processes its output to show the field strength on a 4 1/2 digit display, updated at 2 readings per second. An analog output is also provided. The Mag-01H may be fitted with an audio output indicator, on request. This facility enables the operator to seek the null position without continuously monitoring the digital display. The unit incorporates a facility to offset the field experienced by the probe to ±90µT in steps of 10µT. This allows large fields to be backed-off so that small variations can be observed. A sensitivity switch can be used to select 1nT or 0.1nT resolution. The non-magnetic internal battery provides 20 hours of continuous use and can be recharged via the mains adaptor or vehicle connector. Battery voltage is displayed for several seconds after switch-on and an audible alarm indicates when recharging is required. The magnetometer and cable incorporate shielding against radio frequency interference.

Specification - Mag-01H instrument Measuring range Bandwidth: x1 sensitivity Calibration accuracy 0.1% Maximum resolution Zero field offset Offset drift Scaling temperature coefficient Operating temperature range Relative humidity Dimensions (H x W x D) Weight Enclosure material Liquid crystal display: x1 sensitivity x10 sensitivity Front panel: On/off switch Probe input Charge indicator Sensitivity control Rear panel: Battery charger inlet Analog output x1 sensitivity x10 sensitivity Output impedance ±0.1nT to ±0.2mT DC to 10Hz (-3dB) at 20μT p-p. Roll off -12dB per octave 0.1nT ±1nT 0.01nT/ C <10ppm/ C -10 C to +50 C 80% non-condensing 65 x 155 x 175mm 950g High impact ABS 4 1/2 digit autoranging Displays 0 to 20μT with 1nT resolution and 20 to 200μT with 10nT resolution Displays 0 to 2μT with 0.1nT resolution and 2 to 20μT with 1nT resolution Switches on internal battery 6 pole waterproof Fischer connector Illuminated when external supply connected Increases the sensitivity by a factor of 10 2.1mm socket 6-18V DC 0.5A max., polarity protected, continuous or intermittent use 4mm insulated sockets 100μT/V, ±500μT max, 1nT resolution 10μT/V, ±50μT max, 0.1nT resolution 1kΩ The unit is provided with a carrying bag. www.bartington.com

Mag A Probe The fluxgate element selected for this probe ensures high rejection of orthogonal fields. The probe alignment will normally be stable to 1 minute of arc over the suggested two-year calibration period and re-adjustment is seldom required. The element converts the static terrestrial field into an alternating signal. The Mag-01H instrument converts this signal into a feedback current, which is applied to a precision solenoid within the probe to maintain the element in null field. The magnetometer converts this current into a precise and stable measurement of the field. A mechanically isolated enclosure protects the sensor from accidental misalignment. The probe has a strong but highly flexible 5-metre cable for connection to the Mag-01H instrument. Each probe is individually calibrated to a standard traceable to the UK National Physical Laboratory. Probes and electronics units are fully interchangeable with a cumulative calibration uncertainty of 0.25%.

Specification - Mag A Probe Calibration accuracy 0.1% Collimation error Fluxgate element Operating temperature range Dimensions (H x W x D): with WILD T1 theodolite with Zeiss theodolite Weight Protective enclosure Connecting cable: length core-screen capacitance resistance <20 seconds (collimation adjustment by joystick and clamp) Temperature coefficient <10ppm/ C, length 55mm, with precision feedback solenoid -20 C to +80 C 32.5 x 106* x 50mm 25 x 100* x 50mm * Add on 10mm for cable gland 250g Aluminium housing, mechanically isolated from element mounting 4-core overall screened high flexibility audio grade with 6 pole Fischer connector 5m standard (alternative lengths available) 160pF/m 92Ω/km WILD T1 Steel-free theodolite These optical theodolites are no longer manufactured, so the units supplied are pre-used instruments which have been reconditioned and converted to be non-magnetic. All magnetic components have been replaced by a non-magnetic equivalent. The horizontal and vertical axis bearings have been replaced with specially plated phosphor bronze parts and the steel ball-race removed from the horizontal axis. The WILD axis lubrication system ensures that these parts require zero maintenance. The resetting mechanism for the horizontal circle is redundant in this application and has been eliminated to give enhanced accuracy. All theodolites undergo a rigorous check for magnetic hygiene and are guaranteed to be non-magnetic. The steep sighting prisms (SSP) improve the reading of the scale in the case of a near horizontal field. Without them, field inclined less than 45 from the horizontal cannot be measured. The limit, using the SSP, becomes 18 (25 using the telescope SSP). Theodolite (steel-free) Scaling division Estimation Directional accuracy* WILD T1 (360 ) 6 seconds 3 seconds 3 seconds * The directional accuracy is given as the standard deviation to DIN 18723 of a direction measured in two telescope positions. Weight with fluxgate sensor fitted Weight in carrying case 5.85kg 8.75kg A separate brochure for the WILD T1 theodolite is available on request. www.bartington.com

Accessories AC mains adaptor for 110/220/240V with outlet adaptors Vehicle charging connector 12V DC output (12-24V input) Operation Manual for Mag-01H Declinometer/Inclinometer and WILD T1 theodolite Screwdriver Orange filter and sun filter Lens cap Polycarbonate carrying case for Mag-01H and accessories Case weight: 5.1kg including equipment Optional extras Steel-free tripod (5/8[INCH] - 11 UNC) Tripod weight: 6.1kg (8kg packaged) Steep sighting prisms Audio output Calibration check at Hartland Point Observatory Chemiluminescent light sources (for night use) Pillar mounting adaptor (5/8[INCH] - 11 UNC) with pins on a 120mm PCD

DS0070/07 Bartington Instruments Limited 5 & 10 Thorney Leys Business Park Witney, Oxford, OX28 4GE, England. T: +44 (0)1993 706565 F: +44 (0)1993 774813 E: sales@bartington.com Specifications of the products described in this brochure are subject to change without prior notice. Bartington is a registered trademark of Bartington Instruments Ltd. www.bartington.com